• Title/Summary/Keyword: Rehabilitation Device

Search Result 432, Processing Time 0.028 seconds

Characteristic of LED light curing unit and classification by generation for clinicians (임상가가 알아두면 유용한 LED 광중합기의 특성과 세대별 분류)

  • Shim, Young-Bo;Choi, An-Na;Park, Jeong-Kil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.245-251
    • /
    • 2017
  • Since light curing composite resin was introduced in the 1960s, light curing process has been considered as an essential process. Herein, various light sources became available for the process. Quartz-tungsten-halogen (QTH) light curing units (LCUs) dominated the market until the 1990s, before the LED LCUs started replacing them in the 2000s. The LED, developed approximately 50 years ago, came into use in the dentistry field from the late 1990s, and the LED LCUs, with the 2000s. Since then, the LED LCUs have gone through many advancements to its current fourth generation. In accordance to such advancements of the LED light curing unit, the majority of light curing unit used today are LED LCUs. As much as its usage has increased, it is necessary that dental clinicians understand the characteristics of the device. The objective of this review report is to provide the history of the scientific development and describe the characteristics of the LED LCUs.

Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design (테이퍼드 직선형 SLA 임플란트의 안정성 평가)

  • Kim, Yong-Gun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.80-88
    • /
    • 2018
  • Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was $69.4{\pm}10.2$ at the time of implant placement (baseline) and $81.4{\pm}6.9$ at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

Characteristics of ROM and EMG to Balance Training in Unstable Plate System: Primary Study (균형 훈련 플레이트 시스템을 이용한 생체역학적 특성 연구)

  • Jun, SungChul;Lim, HeeChul;Lee, ChangHyung;Kim, TaeHo;Jung, DukYoung;Chun, KeyoungJin
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.235-239
    • /
    • 2015
  • The purpose of this study was to investigate the unstable plate system for the advanced balance ability. 7 male volunteers (age $33.7{\pm}1.2$ years, height $174.7{\pm}3.8cm$, weight $86.0{\pm}3.6kg$, BMI $28.2{\pm}2.0kg/m^2$) performed the partial squat motion on the shape of CAP type(${\cap}$) and BOWL type(${\cup}$) plate system. The range of motion (ROM) and muscle activation were acquired by the motion analysis system and the EMG system. Results of ROMs of the CAP type plate system were shown the widely range of the deviation in the ankle joint on the sagittal plane (sagittal plane - hip joint $10.7^{\circ}$ > $5.4^{\circ}$, knee joint $16.3^{\circ}$ > $6.4^{\circ}$, ankle joint $18.8^{\circ}$ > $6.3^{\circ}$ ; transverse plane - hip joint $3.5^{\circ}$ > $1.8^{\circ}$, knee joint $5.3^{\circ}$ > $3.4^{\circ}$, ankle joint $11.3^{\circ}$ > $5.3^{\circ}$ ; frontal plane - hip joint $0.9^{\circ}$ > $0.5^{\circ}$, knee joint $0.8^{\circ}$ > $0.6^{\circ}$, ankle joint $4.8^{\circ}$ > $3.7^{\circ}$). Muscle activation results of the CAP type plate system were indicated higher in major muscles for balance performance than the BOWL type plate system (vastus lateralis 0.90 > 0.62, peroneus longus 0.49 > 0.21, biceps femoris 0.38 > 0.14, gastrocnemius 0.11 > 0.05). These findings may indicate that the CAP type plate system would expect better effectiveness in perform the balance training. This paper is primary study for developing balance skills enhancement training device.

The Effect of Improvement of Temporomandibular Joint Movement Restriction using the Kaltenborn-Evjenth Orthopedic Manipulative Therapy (Kaltenborn-Evjenth 정형도수치료가 측두하악관절 운동제한 개선에 미치는 효과)

  • Kim, Sung-Won;Hong, Wan-Sung
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.62-72
    • /
    • 2003
  • The purpose of this study is to prove the efficacy of the Kaltenborn-Evjenth Orthopedic Manipulative Therapy and the Conventional Physical Therapy that influence changes in pain and range of motion when those therapies are applied to patients with temporomandibular pint movement restriction. The subjects of the study were 30 randomly selected patients who had been diagnosed with temporomandibular pint movement restriction and had endured pain for more than two weeks. These patients had visited one of three hospitals in Pyongchon 00 Hospital. The subjects were divided into two groups with 15 patients each. The Kaltenborn-Evjenth Orthopedic Manipulative Therapy was applied to one group and the Conventional Physical Therapy was applied to the other group, once a day for three days. Then, the pain perception degree was measured by using the Visual Analogue Scale(VAS) and a digital device(Absolute Digimatic) measured the range of motion for each group. The average and standard errors were calculated for each measured items and a paired t-test was used for identifying significance in the differences in the pain perception degree and the range of motion between the two groups according to therapy. The significant level was set as ${\alpha}=0.05$. The changes in the pain perception degree were statistically significant in both groups; however, the group that received Kaltenborn-Evjenth Orthopedic Manipulative Therapy(KE-Group) showed more significant changes in a decrease in the pain perception degree than did the group that received the Conventional Physical Therapy(CPT-Group). Both groups showed significant results regarding changes in the range of motion: however, the KE-Group showed more of a significant difference in the average of the range of motion than did the CPT-Group(p<0.001). Comparing the changes in the range of motion between the two groups, the KE-Group showed a significant result which means that the KE-Group had a higher therapy effect than did the CPT-Group(p<0.05). Based on the results of this study, we found that the Kaltenborn-Evjenth Orthopedic Manipulative Therapy decreased pain and increased the range of motion. With such findings, we expect that the Kartenborn-Evjenth Orthopedic Manipulative Therapy can be used as an effective treatment method for patients with tempomrnandibular pint movement restriction and that the treatment period can be reduced with this therapy as well.

  • PDF

Angled implant brush for hygienic maintenance of full-arch fixed-implant rehabilitations: a pilot study

  • Setti, Paolo;Pesce, Paolo;Dellepiane, Elena;Bagnasco, Francesco;Zunino, Paola;Menini, Maria
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.5
    • /
    • pp.340-354
    • /
    • 2020
  • Purpose: This pilot study was conducted to evaluate the cleaning efficacy of an angled implant brush for home oral hygiene of full-arch fixed-implant prostheses. Methods: Forty-one patients treated with a full-arch implant rehabilitation in the maxilla or mandible (164 implants) for at least 4 months were enrolled. The screw-retained fixed prostheses were removed and baseline (T0) parameters were recorded, including plaque index (PI), probing depth (PD), and bleeding on probing (BOP). All patients completed a 5-item questionnaire on hygiene maintenance and received an implant brush for home hygiene. After 1 month (T1) PI, PD, and BOP were recorded again and patients completed a 7-item questionnaire to evaluate their satisfaction with the implant brush. One-way repeated-measures analysis of variance was conducted to evaluate the significance of changes in PI, PD, and BOP. A P value <0.05 was considered to indicate statistical significance. Results: A statistically significant reduction of BOP (0.62±0.6 at T0 vs. 0.5±0.5 at T1; P=0.032) was found, while no statistically significant changes in PD (1.74±0.5 mm at T0 vs. 1.77±0.5 mm at T1; P=0.050) or PI (1.9±0.7 at T0 vs. 1.7±0.7 at T1; P=0.280) occurred. According to the 7-item questionnaire, patients reported no difficulty in using the angled brush (63.4%) and deemed it highly (46.3%) or very highly (4.8%) effective in improving their home oral hygiene. Conclusions: Within the limits of the present pilot study, the patients experienced a reduction of BOP 1 month after being instructed to use the angled implant brush. The angled implant brush appeared to be a well-accepted device for home-care hygiene of full-arch fixed-implant rehabilitations.

ERS Feature Extraction using STFT and PSO for Customized BCI System (맞춤형 BCI시스템을 위한 STFT와 PSO를 이용한 ERS특징 추출)

  • Kim, Yong-Hoon;Kim, Jun-Yeup;Park, Seung-Min;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.429-434
    • /
    • 2012
  • This paper presents a technology for manipulating external devices by Brain Computer Interface (BCI) system. Recently, BCI based rehabilitation and assistance system for disabled people, such as patient of Spinal Cord Injury (SCI), general paralysis, and so on, is attracting tremendous interest. Especially, electroencephalogram (EEG) signal is used to organize the BCI system by analyzing the signals, such as evoked potential. The general findings of neurophysiology support an availability of the EEG-based BCI system. We concentrate on the event-related synchronization of motor imagery EEG signal, which have an affinity with an intention for moving control of external device. To analyze the brain activity, short-time Fourier transform and particle swarm optimization are used to optimal feature selection from the preprocessed EEG signals. In our experiment, we can verify that the power spectral density correspond to range mu-rhythm(${\mu}8$~12Hz) have maximum amplitude among the raw signals and most of particles are concentrated in the corresponding region. Result shows accuracy of subject left hand 40% and right hand 38%.

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Postural Control in Brain Damage Patients According to Moving Surround (뇌기능 장애 환자의 가상영상(Moving Sorround) 자극에 따른 자세 균형 제어)

  • 김연희;최종덕;이성범;김종윤;이석준;박찬희;김남균
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.233-244
    • /
    • 2002
  • The purpose of this study is to assess the ability of balance control in moving surround using head mount device and force platform and to examine the clinical usefulness of COP parameters. Fifteen patients with stroke and healthy persons were participated. COP parameters were obtained as total path distance, frequency of anterior-posterior and medial-lateral component by FFT analysis, weight-spectrum analysis in the two different conditions; (1) in comfortable standing with opened or closed eyes, (2) in virtual moving surround delivered using HMD to four different moving pattern. In virtual moving surround setting, moving pattern was composed of close-far, superior-inferior tilting(pitch), right-left tilting(roll) and horizontal rotation(yaw) movement. In all parameters, the reliebility of COP analysis system was significantly high. Also, the construct validity compared between fifteen patients with stroke and normal persons was excellent in virtual moving surround condition(p

  • PDF

Effect of Occlusal Stabilization Appliance on Driving Distance in Golf (교합안정장치가 전문골프선수들의 드라이버 비거리에 미치는 영향)

  • Kwon, Tae-Hoon;Shin, Sang-Wan;Ryu, Jae-Jun;Lee, Richard Sung-Bok;Ahn, Su-Jin;Choi, Yeo-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.157-168
    • /
    • 2010
  • Many athletes have been using occlusal stabilization appliances to improve their performance. Few studies have examined the benefits of such an appliance in golf. We determined the effect of such appliances on the masticatory muscle activities and driving distances of professional golf players. The appliances were customized for each player and adjusted using a computerized device. The electromyographic muscle activities and driving distances with and without the appliance were measured and compared using the K7 Analyzer and the GolfAchiever II assembly. A paired t-test was used for statistical analysis. The muscle activities of the temporo-frontal and masseter muscles with the appliance were significantly more stable than those without the appliance, and the driving distances with the appliance were significantly different from those without it. Although there were intra-individual differences, professional golf players with temporomandibular disorders showed a greater improvement in performance.

Evaluation of Tightness of Proximal tooth Contact on Implant Prostheses (임프란트 보철수복물에서의 인접치간 접촉강도의 평가)

  • Kim, Sang-Pil;Jung, J-Hyun;Kang, Dong-Wan;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.371-379
    • /
    • 2008
  • The aim of this study was to evaluate the tightness of proximal tooth contact(TPTC) using a novel device at rest state on implant prostheses. Ten healthy young adults with class I normal occlusion consented to participate in the study and twenty patients were restored with a total 20 single-implant crowns in the left maxillary and mandibular second molars for 10 single-implant crowns, respectively. Test area were divided by 4 groups. UM describes the contact between the upper natural left first molar and natural second molar; LM the contact between the lower natural left first molar and natural second molar; IUM the contact between the upper natural left first molar and implant second molar and ILM the contact between the lower natural left first molar and implant second molar. The TPTC was measured at rest state in each area. The mean TPTC of the UM, LM, IUM and ILM was 1.48(${\pm}0.44$) N, 1.78(${\pm}0.40$) N, 1.14(${\pm}0.37$) N and 1.30(${\pm}0.32$) N respectively. These results indicate that the TPTC was less between natural tooth and implant prosthesis than between natural teeth.