• Title/Summary/Keyword: Regional office

Search Result 768, Processing Time 0.032 seconds

The Electro-Mechanical Properties of Disk-Type Stator for Ultrasonic Motor (초음파 모터용 디스크형 고정자의 전기기계적 특성)

  • Lee, J.S.;Kim, B.W.;Lee, S.H.;Shin, S.I.;Nam, K.D.;Oh, H.K.;Jang, Y.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.339-340
    • /
    • 2006
  • In this paper, disk-type ultrasonic motor using radial and bending vibration modes is newly designed and fabricated to measure its characteristics. As the diameter of elastic body increases, the resonant frequency decreases and its resonant frequency is about 92kHz when the physical dimensions of piezoelectric ceramic and elastic body are 28mm of diameter and 2mm of thickness, and 32mm of diameter and 2mm of thickness, respectively. When the applied voltage is 20Vpp. its speed and torque are 200rpm and 1N, respectively.

  • PDF

A Study on Architectural Design Factors for Tall Office Buildings with Regional Climates based on Sustainability

  • Cho, Jong Soo
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.13-21
    • /
    • 2005
  • Throughout history, buildings have been interrelated with certain indigenous characteristics such as regional climate, culture and religions. In particular, the control of regional climate has been primarily a concern for compatibility with nature. In our modern age, technologies to control climate have been successfully developed in architecture but the consumption of large quantities of natural resources can also produce environmental problems. This study is based on the proposition that this negative trend can be minimized with architectural design that is motivated to coexist with a regional climate. This study develops these design strategies for tall office buildings by analyzing various combinations of building design configurations based on regional climates. The objective is to determine the optimum architecture of tall office buildings during the initial design process that will reduce energy consumption for regional climatic conditions. The eQUEST energy simulating program based on DOE-2.2 was used for this comparative analysis study of the energy use in tall office buildings based on architectural design variables and different regional climates. The results are statistically analyzed and presented in functional architectural design decision-making tables and charts. As a result of the comparison of architectural design consideration for tall office buildings in relation to regional climates, buildings physically need less energy consumption when the architecture is concerned with the regional climate and it produces a more reasonable design methodology. In reality, imbalanced planning which is architectural design's lack of regional characteristics requires additional natural resources to maintain desired comfortable indoor conditions. Therefore, the application of integrated architectural design with regional nature should be the first architectural design stage and this research produces the rational. This architectural design language approach must be a starting point to sustaining long-term planning.

A Study on Reported Status and Management Plan of Marine Facilities in Korea 2. On the Basis of Region and Type of Facilities (국내 해양시설의 신고 현황과 관리 방안에 관한 연구 2. 지역별 및 시설종류별 현황을 중심으로)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.3
    • /
    • pp.275-285
    • /
    • 2010
  • Present state of nationwide marine facilities reported to 12 regional maritime affairs and port offices of MLTM in Korea for two years 2008 and 2009 was analyzed based on region and type of facilities, and national management plan was proposed in this study. As of the end of 2009, 8 types of marine facilities were reported to Yeosu regional maritime affairs and port office, while only 3 types of facilities were reported to Pohang, Daesan and Jeju regional offices, respectively. Oil and noxious liquid substances storage facilities belonged in the type of facility which was reported to all of 12 regional offices, and ranged from 11 facilities reported to Pyeongtaek regional office to the respective 38 facilities to Yeosu and Masan regional offices. In pollutants storage facilities, 4 facilities were reported to Masan regional office, 2 facilities to Donghae and Mokpo regional offices, respectively, 1 facility to Yeosu, Gunsan and Pyeongtaek regional offices, respectively, and none of facilities to the other regional offices. Ship construction, repair and scrap facilities belonged in the type of facility which was reported to all of 12 regional offices, and 45% of the facilities were concentrated in Southeastern Sea of Korea centering around Busan and Masan. In cargo handling facilities, 3 facilities were reported to Busan and Masan regional offices, respectively, 1 facility to Daesan regional office, and none of facilities to the other regional offices. In wastes storage facilities, 5 facilities were reported to Ulsan regional office, 4 facilities to Gunsan regional office, 2 facilities to Incheon regional office, 1 facility to Yeosu regional office, and none of facilities to the other regional offices. 65% of nationwide water intake and drainage facilities were concentrated in the areas of Pohang and Mokpo, and 78% of nationwide fishing spots at play were concentrated in the area of Masan. In other marine facilities, 4 facilities were reported to Donghae regional office, 3 facilities to Masan regional office, 2 facilities to Yeosu and Pyeongtaek regional offices, respectively, 1 facility to Incheon and Ulsan regional offices, respectively, and none of facilities to the other regional offices. In integrated marine science base facilities, 3 facilities were reported to Jeju regional office, 1 facility to Yeosu, Ulsan and Gunsan regional offices, respectively, and none of facilities to the other regional offices. The management based on the circumstances of regional offices, the management based on the characteristics of the type of facilities, the amendment of the relevant rules and regulations, facility owner's full knowledge and observance of the relevant rules and regulations with regard to the relevant type of facilities, and positive management actions from national point of view were proposed for national management plans of marine facilities.

The consideration of the Isolation Mode for Digital Governor System (Digital Governor의 Isolation Mode에 대한 고찰)

  • Ok, Yeon-Ho;Lee, Yong-Gil;Han, Cheol-Hui;Kwak, Won-Ku;Cho, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.776-777
    • /
    • 2011
  • 조속기는 수차발전기의 핵심을 담당하는 두뇌라고 말할 수 있으며, 전력계통의 부하(주파수)가 변할 경우 수차발전기의 회전속도를 정격으로 유지시켜 양질의 전기를 생산하도록 항시 조정되는 역할을 한다. 최근 조속기는 디지털화되어 최적제어 감시 및 보호기능을 수행하고 있으나 문제점도 하나둘씩 나타나고 있는 실정이다. 본 논문에서는 디지털 가버너의 Isolation Mode에 대한 설명과 사고사례를 통해 디지털가버너 운영 시 문제점을 분석, 검토하여 보완하고자 하였으며, 이를 통해 안정적으로 전력공급을 주요 목적으로 하였다.

  • PDF

Studies on the stability examination of biological products - BCG vaccine

  • Lee, Joo-Hyeun;Shin, Won-Pil;Ahn, Hye-Jeong;Kim, So-Hee;Lee, Gil-Woong
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.180.3-180.3
    • /
    • 2003
  • This study was carried out to examine stability of biological products(BCG vaccine), freeze-dried BCG vaccine for percutaneous use and for interdermal use.1. pH tests of freeze-dried BCG vaccine for percutaneous use and for interdermal use vaccine was suited to basic range with variable temperature. freeze-dried BCG vaccine for percutaneous use was resulted with 6.2-6.7 and for interdermal use was resulted with 6.2-6.7.2. Bacterial concentration test of freeze-dried BCG vaccine for percutaneous use and for interdermal use vaccine was suited to basic range with variable temperature. (omitted)

  • PDF

The consideration of the electronic cooling device for outside panel (옥외 자립형 PANEL에 적용한 전자냉각장치 고찰)

  • Ok, Yeon-Ho;Lim, Jae-Il;Park, Ji-Kun;Kwak, Won-Ku;Lee, Jae-Heung;Kim, Byung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.353-354
    • /
    • 2008
  • 옥외 현장에 설치되어 있는 PANEL은 하절기에 내부 온도가 높아져 PANEL 내부에 설치되어 있는 제어장치의 정상 동작을 방해 할 수 있다. 실제로 하절기 오후 $2{\sim}3$시경 PANEL 내부의 온도는 약 $60{\sim}75^{\circ}C$ 정도의 고온을 유지한다. 근래에는 현장 PANEL 내부에 PLC 및 컨트롤러등 전자화된 제어 장치의 설치 비중이 증가하고 있고 대부분의 컨트롤러 사용 온도는 약 $0{\sim}55^{\circ}C$ 이므로 하절기 고온 상태에서 정상적인 동작을 기대하기는 어렵다. 본 논문에서는 옥외 자립형 PANEL의 냉각 장치를 개발하여 운영하고 그 효과를 분석, 검토함으로써 하절기 고온 상태에서도 안정적으로 설비가 정상 동작하기 위한 방안 제시를 주요 목적으로 한다.

  • PDF

Analysis of Heat Loss Due to Time Dependent Aging of Insulation Applied to Office Building (업무용 건축물에 적용된 단열재의 경년열화에 따른 열손실량 분석)

  • Lee, Do-Hyung;Nah, Hwan-Seon
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.5
    • /
    • pp.65-75
    • /
    • 2017
  • In this study, the change of heat loss due to the degree of deterioration of the XPS insulation in KEPCO's office buildings is analyzed. The acceleration aging test of the XPS insulation was carried out according to the test method A of KS M ISO 11561: 2009. The performance of the insulation was analyzed by applying it to the three - dimensional steady state heat transfer analysis program. The acceleration aging test of the XPS insulation, show that the thermal resistance performance decreased by 1.44% at the A regional headquarters, 0.85% at the B regional headquarters, 6.41% at the C branch office, 7.76% at the D regional headquarters, 8.51% at the E branch office, and by 8.54% at the F branch office respectively. Using simulation, we determined that the thermal resistance value of E branch office decreased by 8.04%, while its heat loss increased by 8.52%. At A regional headquarters, the thermal resistance decreased by 1.38%, and the heat loss increased by 1.51%. At D regional headquarters, these value are 6.82% and 7.17%, respectively.

The Effect of Inversion Layer on the Land and Sea Breeze Circulations near the Gangneung (역전층이 강릉시 주변 해륙풍 순환에 미치는 영향 연구)

  • NamGung, Ji-Yeon;Yu, Jae-Hoon;Kim, Nam-Won;Choi, Man-Kyu;Ham, Dong-Ju;Kim, Hoon-Sang;Jang, You-Jung;Choi, Eun-Kyung
    • Atmosphere
    • /
    • v.15 no.4
    • /
    • pp.229-239
    • /
    • 2005
  • The effect of inversion layer on the land and sea breeze near the Gangneung city was investigated. The land and sea breeze occurrence days were selected, and the height and the intensity of inversion layer were calculated with the upper air observational data of the Sokcho Station. The relationships between the temperature variation near the Gangneung and the inflow time, inland penetration and the inflow depth of the land and sea breeze were also analyzed. And the Gangwon Short-range prediction system was verified with the comparison of surface stream line by the Gangwon short-range prediction system with the AWS wind vector data. It was revealed that the inversion layer tended to block the sea breeze, shorten the inland penetration distance and lower the inflow depth, causing the temperature rise. The comparison and analysis of surface steam line by the Gangwon short-range prediction system and the AWS wind vector showed that the system quite well simulated the sea breeze, thus the system could be well utilized in the prediction of land and sea breeze.