• Title/Summary/Keyword: Region-based Image

Search Result 1,855, Processing Time 0.023 seconds

An Initial Study on the Reliability Assurance in PET/CT Standardized Uptake Values (PET/CT 에서 표준섭취계수(SUV)의 신뢰성 확보를 위한 초기연구)

  • Park, Hoon-Hee;Kim, Jung-Yul;Lee, Seung-Jae;Park, Min-Soo;NamKoong, Hyuk;Lim, Han-Sang;Oh, Ki-Baek;Kim, Jae-Sam;Lee, Chang-Ho;Jin, Gye-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.31-42
    • /
    • 2009
  • Purpose: As the number of domestic medical institutions installing PET/CT is increasing rapidly, the transfer of PET/CT images among medical institutions is also increasing. Thus, it is necessary to collect the comparative SUV data from several medical institutions' PET/CT systems through a phantom study which semi-quantitatively compares the SUV on one bed, the change scale of the SUV on the slices, and the time of measuring. The phantom study to find differences among the SUVs from various PET/CT offers the opportunity to obtain the reliability of the SUV in PET/CT images. Materials and Methods: Ten PET/CT systems from medical institutions in Korea were used. To obtain the accurate data, the study has been using the radiation detector of Korea Research Institute of Standards and Science to verify. The internal structures of NEMA $phantom^{TM}$ were removed and Six thousand milliliters of distilled water which has 1mCi of $^{18}F$-FDG put into the phantom. The water was properly integrated with $^{18}F$-FDG using magnetic stirrer. The images were acquired at 60, 70, 80, 90, 100, 110 and 120-minutes for 3 minute each. Two hundred square centimeters of region of interests were placed and analyzed. To confirm the usefulness, the correction-table came out from patients' data. Results: The coefficient of variability of the SUV from -11.0 to 9.90 % fell into the range of international standards(${\pm}10%$) along with the SUV on a bed, the change scale of the SUV on the slices, and the time of measuring, except one PET/CT system. Using the data of the differences among the SUVs, we came to withdraw the correction-table ranging from 0.803 to 1.246. The correction-table was confirmed its usefulness through Linear Regression Analysis which was applied to normal cases. Conclusions: Although studies have been made on the variation of the SUV, there is little attention on the standardization of the SUV. Based on this study of the quantitatively comparable data about the SUV accommodating the correction-table, it would help to have more corrective diagnosis.

  • PDF

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

A Basic Study for the Retrieval of Surface Temperature from Single Channel Middle-infrared Images (단일 밴드 중적외선 영상으로부터 표면온도 추정을 위한 기초연구)

  • Park, Wook;Lee, Yoon-Kyung;Won, Joong-Sun;Lee, Seung-Geun;Kim, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.2
    • /
    • pp.189-194
    • /
    • 2008
  • Middle-infrared (MIR) spectral region between 3.0 and $5.0\;{\mu}m$ in wavelength is useful for observing high temperature events such as volcanic activities and forest fire. However, atmospheric effects and sun irradiance in day time has not been well studied for this MIR spectral band. The objectives of this basic study is to evaluate atmospheric effects and eventually to estimate surface temperature from a single channel MIR image, although a typical approach utilize split-window method using more than two channels. Several parameters are involved for the correction including various atmospheric data and sun-irradiance at the area of interest. To evaluate the effect of sun irradiance, MODIS MIR images acquired in day and night times were used for comparison. Atmospheric parameters were modeled by MODTRAN, and applied to a radiative transfer model for estimating the sea surface temperature. MODIS Sea Surface Temperature algorithm based upon multi-channel observation was performed in comparison with results from the radiative transfer model from a single channel. Temperature difference of the two methods was $0.89{\pm}0.54^{\circ}C$ and $1.25{\pm}0.41^{\circ}C$ from the day-time and night-time images, respectively. It is also shown that the emissivity effect has by more largely influenced on the estimated temperature than atmospheric effects. Although the test results encourage using a single channel MR observation, it must be noted that the results were obtained from water body not from land surface. Because emissivity greatly varies on land, it is very difficult to retrieval land surface temperature from a single channel MIR data.

Estimation of Fractional Urban Tree Canopy Cover through Machine Learning Using Optical Satellite Images (기계학습을 이용한 광학 위성 영상 기반의 도시 내 수목 피복률 추정)

  • Sejeong Bae ;Bokyung Son ;Taejun Sung ;Yeonsu Lee ;Jungho Im ;Yoojin Kang
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_3
    • /
    • pp.1009-1029
    • /
    • 2023
  • Urban trees play a vital role in urban ecosystems,significantly reducing impervious surfaces and impacting carbon cycling within the city. Although previous research has demonstrated the efficacy of employing artificial intelligence in conjunction with airborne light detection and ranging (LiDAR) data to generate urban tree information, the availability and cost constraints associated with LiDAR data pose limitations. Consequently, this study employed freely accessible, high-resolution multispectral satellite imagery (i.e., Sentinel-2 data) to estimate fractional tree canopy cover (FTC) within the urban confines of Suwon, South Korea, employing machine learning techniques. This study leveraged a median composite image derived from a time series of Sentinel-2 images. In order to account for the diverse land cover found in urban areas, the model incorporated three types of input variables: average (mean) and standard deviation (std) values within a 30-meter grid from 10 m resolution of optical indices from Sentinel-2, and fractional coverage for distinct land cover classes within 30 m grids from the existing level 3 land cover map. Four schemes with different combinations of input variables were compared. Notably, when all three factors (i.e., mean, std, and fractional cover) were used to consider the variation of landcover in urban areas(Scheme 4, S4), the machine learning model exhibited improved performance compared to using only the mean of optical indices (Scheme 1). Of the various models proposed, the random forest (RF) model with S4 demonstrated the most remarkable performance, achieving R2 of 0.8196, and mean absolute error (MAE) of 0.0749, and a root mean squared error (RMSE) of 0.1022. The std variable exhibited the highest impact on model outputs within the heterogeneous land covers based on the variable importance analysis. This trained RF model with S4 was then applied to the entire Suwon region, consistently delivering robust results with an R2 of 0.8702, MAE of 0.0873, and RMSE of 0.1335. The FTC estimation method developed in this study is expected to offer advantages for application in various regions, providing fundamental data for a better understanding of carbon dynamics in urban ecosystems in the future.

Evaluation of Multiple System Atrophy and Early Parkinson's Disease Using $^{123)I$-FP-CIT SPECT ($^{123)I$-FP-CIT SPECT를 이용한 다중계위축증 및 조기 파킨슨병에서의 평가)

  • Oh, So-Won;Kim, Yu-Kyeong;Lee, Byung-Chul;Kim, Bom-Sahn;Kim, Ji-Sun;Kim, Jong-Min;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • Purpose: We investigated quantification of dopaminergic transporter (DAT) and serotonergic transporter (SERT) on $^{123}I$-FP-CIT SPECT for differentiating between multiple systemic atrophy (MSA) and idiopathic Parkinson's disease (IPD). Materials and Methods: N-fluoropropyl-$2{\beta}$-carbomethoxy-$3{\beta}$-4-[$^{123}I$]-iodophenylnortropane SPECT ($^{123}I$-FP-CIT SPECT) was performed in 8 patients with MSA (mean age: $64.0{\pm}4.5yrs$, m:f=6:2), 13 with early IPD (mean age: $65.5{\pm}5.3yrs$, m:f=9:4), and 12 healthy controls (mean age: $63.3{\pm}5.7yrs$, m:f=8:4). Standard regions of interests (ROls) of striatum to evaluate DAT, and hypothalamus and midbrain for SERT were drawn on standard template images and applied to each image taken 4 hours after radiotracer injection. Striatal specific binding for DAT and hypothalamic and midbrain specific binding for SERT were calculated using region/reference ratio based on the transient equilibrium method. Group differences were tested using ANOVA with the postHoc analysis. Results: DAT in the whole striatum and striatal subregions were significantly decreased in both patient groups with MSA and early IPD, compared with healthy control (p<0.05 in all). In early IPD, a significant increase in the uptake ratio in anterior and posterior putamen and a trend of increase in caudate to putamen ratio was observed. In MSA, the decrease of DAT was accompanied with no difference in the striatal uptake pattern compared with healthy controls. Regarding the brain regions where $^{123}I$-FP-CIT binding was predominant by SERT, MSA patients showed a decrease in the binding of $^{123}I$-FP-CIT in the pons compared with controls as well as early IPD patients (MSA: $0.22{\pm}0.1$ healthy controls: $0.33{\pm}0.19$, IPD: $0.29{\pm}0.19$), however, it did not reach the statistical significance. Conclusion: In this study, the differential patterns in the reduction of DAT in the striatum and the reduction of pontine $^{123}I$-FP-CIT binding predominant by SERT could be observed in MSA patients on $^{123}I$-FP-CIT SPECT. We suggest that the quantification of SERT as well as DAT using $^{123}I$-FP-CIT SPECT is helpful to differentiate parkinsonian disorders in early stage.