• Title/Summary/Keyword: Regenerator mesh

Search Result 12, Processing Time 0.024 seconds

Basic Study on the Regenerator of Stilting Engine (III) - Heat Transfer and Flow Friction Characteristic of the Regenerator with Combined Wire-mesh Matrix - (스털링 기관용 재생기에 관한 기초 연구 (III) - 복합메쉬 철망을 축열재로 한 재생기의 전열 및 유동손실 특성 -)

  • Lee S. M.;Kim T. H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.4 s.111
    • /
    • pp.195-201
    • /
    • 2005
  • The output of Stirling engine is influenced by the regenerator effectiveness. The regenerator effectiveness is influenced by heat transfer and flow friction loss of the regenerator matrix. In this paper, in order to provide a basic data for the design of regenerator matrix, characteristics of heat transfer and flow friction loss were investigated by a packed method of matrix in the oscillating flow as the same condition of operation in a Stirling engine. As matrices, several kinds of combined wire screen meshes were used. The results are summarized as follows; The packed meshes with high mesh no. in the side of heater part of regenerator showed effective than the packed meshes with low mesh no. in the side of cooler part of regenerator. The temperature difference and pressure drop of the regenerator were not made by the specific surface area of wire screen meshes but by the minimum free-flow area to the total frontal area. Among the No. 150 single screen meshes, 200-60 combined meshes, the 200-150-100 combined meshes showed the highest in effectiveness.

Heat Transfer of Oscillating Flow in a Cylinder with Regenerator (재생기를 가진 실린더내의 왕복유동에 관한 열전달)

  • 김진호;이재헌;강병하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1758-1769
    • /
    • 1995
  • The heat transfer of oscillating flow in a cylinder with regenerator was investigated by the moving boundary technique. The flow in regenerator was modeled by means of Brinkman Forchheimer-Extended-Darcy equation . Results showed that when piston moved toward right, velocity vectors near cylinder wall at left piston and right side of regenerator inclined to symmetric axis and velocity vectors near cylinder wall at right piston and left side of regenerator inclined to cylinder wall. And the time averaged Nusselt number was increased by 46.73% when the oscillatory frequency became twice and decreased by 31.46% when the oscillatory frequency became half. The time averaged Nusselt number was increased by 18.09% when thickness of the regenerator became twice and decreased by 7.53% when thickness of the regenerator became half. But mesh size of regenerator hardly affected the Nusselt number. And efficiency of regenerator was larger as the oscillatory frequency was smaller, thickness and mesh size of regenerator was larger.

Basic Study on the Regenerator of Stilting Engine (II) - Heat transfer and flow friction loss characteristics of the regenerator with wire screen matrix - (스털링기관용 재생기에 관한 기초연구 (II) - 철망을 축열재로 한 재생기의 전열 및 유동손실특성 -)

  • 김태한;이시민;이정택
    • Journal of Biosystems Engineering
    • /
    • v.27 no.6
    • /
    • pp.529-536
    • /
    • 2002
  • The performance of stilting engine, in particular, its energy conversion efficiencies are critically influenced by the regenerator characteristics. The regenerator characteristics are influenced by effectiveness, void fraction. heat transfer loss and fluid friction loss in the regenerator matrix. These factors were influenced by the surface geometry and material properties of the regenerator matrix. The regenerator design goals arc good heat transfer and low pressure drop of working Bas across the regenerator. Various data for designing a wire screen matrix have been given by Kays and London(1984). The mesh number of their experiment. however, was confined below the No. 60. which seems rather small for the Stirling engine applications. In this paper. in order to provide a basic data for the design of regenerator matrix, characteristics of heat transfer and flow friction loss were investigated by a packed mettled of matrix in oscillating flow as the same condition of operation in a Stirling engine. Seven kinds of sing1e wire screen meshes were used as the regenerator matrices. The results are summarized as follows; 1. While the working fluid flew slowly in the regenerator. the temperature difference was great at the both hot-blow(the working fluid flows from healer to cooler) and cold-blow(the working fluid flows from cooler to healer). On the other hand. while the working fluid flew fast. the temperature difference was not distinguished. 2. The No.150 wire screen used as the regenerator matrix showed excellent performance than tile others. 3. Phase angle variation and filling rate affected heat transfer or regenerator matrices. 4. Temperature difference between the inlet and outlet of the regenerator is very hish in degree of 120 phase angle.

Experimental Study on Regenerator Under Cryogenic Temperature and Pulsating Pressure Conditions (극저온 맥동 압력 조건에서의 재생기에 관한 실험적 연구)

  • Nam, Gwan-U;Jeong, Sang-Gwon;Jeong, Eun-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1095-1101
    • /
    • 2002
  • An experimental apparatus was prepared to investigate thermal and hydrodynamic characteristics of regenerator at cryogenic temperature under pulsating pressure condition. The regenerator was pressurized and depressurized by a compressor with various operating frequencies. Cold end of the regenerator was maintained around 100 K by means of a liquid nitrogen heat exchanger. Instantaneous gas temperature and mass flow rate were measured at both ends of the regenerator during the whole pressure cycle. Pulsating pressure drop across the regenerator was also measured to see if it could be predicted by a friction factor at steady flow condition. The operating frequency of pressure cycle was varied between 3 and 60 Hz, which are typical operating frequencies of Gifford-McMahon, pulse tube, and Stilting cryocoolers. First, the measured friction factor for typical wire screen mesh regenerator was nearly same as steady flow friction factor for maximum oscillating Reynolds number up to 100 at less than 9 Hz. For 60 Hz operations, however, the discrepancy between oscillating flow friction factor and steady flow one was noticeable if Reynolds number was higher than 50. Second, the ineffectiveness of regenerator was directly calculated from experimental data when the cold-end was maintained around 100 K and the warm-end around 293 K, which simulates an actual operating condition of cryogenic regenerator. Influence of the operating frequency on ineffectiveness was discussed at low frequency range.

Performance Characteristics of a Regenerative Heat Exchanger Depending on Its Porous Structure (스털링 엔진용 재생 열교환기의 다공체 구조에 따른 성능 특성)

  • Shin, Myung-Chul;Ahn, Joon;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.415-421
    • /
    • 2012
  • Stirling engine is an external combustion engine, whose efficiency approaches that of Carnot engine with the help of a regenerator. The regenerator is a heat exchanger composed of porous medium, whose performance is dependent on the pore structure. Three types of pore structures are considered in the present study. They are wire screen, random wire and composite structure, i.e. a combination of wire screens with different hydraulic diameters. The porosity more highly affects the performance of a regenerator compared to the hydraulic diameter. The random wire can yield high effectiveness even at a high porosity. The composite mesh gives better performance when the hydraulic diameter decreases in the direction from hot side to cold side.

Effects of regenerator and cooler on the cooling performance of a vuilleumier cycle heat pump (재생기 및 냉각기가 VM열펌프의 냉방성능에 미치는 영향)

  • Lee, G.T.;Kang, B.H.;Yoo, H.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.333-342
    • /
    • 1997
  • An experimental study has been carried out to investigate the effects of the combination of the different wire mesh number in a regenerator and the tube number in a cooler on the cooling performance of a Vuilleumier cycle heat pump. Effects of operating conditions, such as charging pressure, operating speed, and heat input, on the cooling performance are also studied. The experimental results obtained indicate that the cooling performance could be improved with the proper combination of different wire meshes in a regenerator. More tubes in a cooler are desirable for better cooling performance. It is also found that the cooling capacity is enhanced, whereas COP is reduced with an increase in the heater tube temperature and the revolution speed. Both the cooling capacity and COP are incereased with a higher charging pressure.

  • PDF

An experimental study on the characteristics of Gifford-McMahon cryocooler (Gifford-McMahon 극저온 냉동기의 특성에 관한 실험적 연구)

  • 정철진;고득용
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.71-76
    • /
    • 2002
  • To achieve good cryogenic circumstances by Gifford-McMahon cryocooler, we have to constitute optimal conditions with various factors for G-M cryocooler. In this study, cool-down characteristics were presented with some factors using brass matrix mesh (1st stage) and Pb ball (2nd stage) as regenerator materials for the heat exchangers. The effects of the variations of Helium gas pressure and cycle frequency on the cooling capacity of G-M cryocooler are investigated experimentally. The presented results could be summarized as follows : 1) As the steady state pressure increases, 'no load temperature' decreases but cooling capacity increases. 2) It is confirmed that the characteristics of the specific heat of the regenerator materials agree well with the cool-down characteristics of 10 K cryocooler.

  • PDF

An Experimental Study on Performance of the Inertance Pulse Tube Refrigerator using a Small Compressor (소형 압축기를 이용한 관성관형 맥동관 냉동기의 성능 특성에 대한 실험적 연구)

  • Kim Hongseong;Jeong Sangkwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.552-559
    • /
    • 2005
  • This paper describes an experimental study on the inertance pulse tube refrigerator using a small compressor. The purpose of this experimental study is to identify the performance of the inertance pulse tube refrigerator for various operating conditions and to obtain the optimum configuration. The dead volume effect is verified by two experimental apparatuses with different dead volumes between the compressor and the aftercooler. The refrigerator of the smaller dead volume shows better performance. The influence of operating frequency and charging pressure on the performance of the refrigerator is experimentally investigated. Reducing the regenerator mesh size improves the performance of the refrigerator. Finally, the inertance pulse tube refrigerator has maximum cooling capacity at the specific combination of the pulse tube length and the inertance tube length. The loss analysis is used to analyze and predict the optimum condition of the pulse tube refrigerator.