• Title/Summary/Keyword: Refuse fuel

Search Result 111, Processing Time 0.022 seconds

A Study on Combustion Characteristics of Refuse Derived Fuel(RDF) in Various Incinerators (연소방식별 폐기물 고형연료(RDF)의 연소특성 연구)

  • Kim Woo-Hyun
    • Resources Recycling
    • /
    • v.15 no.1 s.69
    • /
    • pp.46-57
    • /
    • 2006
  • For the development of combustion technology of RDF(refuse derived fuel), combustion characteristics are examined in bubbling fluidized bed, circulating fluidized bed, continuos combustor and batch type combustor. The characteristics of combustion and exhaust gas has been compared and analyzed in many type of combustion facilities, which has been utilized as basic data for the advanced research of specified RDF combustion facility. Stable combustion has been observed in bubbling and circulating fluidized bed from controled operating condition like the proper feeding rate and superficial gas velocity. In circulating fluidized bed, concentration of NOx has been increased with the operating condition by the fuel-NO and oxygen reaction and $SO_2$ can be considered not to be produced in RDF fluidized bed from very low concentration in flue gas. HCl concentration is 36.4 ppm as average value and lower than standard emission value, but the counter plan is needed. Shaped RDF and fluff RDF have been compared in continuos combustor and batch type combustor and shaped RDF shows benefit for the stable heat recovery and gas emission shows similar value and characteristics.

Characteristics of Gasification for a Refused Plastic Fuel (플라스틱 고형 연료의 가스화 특성)

  • Chun, Young Nam;Lim, Mun Sup;Jo, Dae Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.11
    • /
    • pp.636-641
    • /
    • 2015
  • Waste energy conversion to SRF (Solid Refuse Fuel) has the effects not alternative fossil fuel usage but also the reduction of greenhouse gas. But the direct burning of the SRF including a plastic waste generates air pollution problem like soot, dioxin, etc. so that an application of pyrolysis and gasification treatment should be needed. The purpose of this study is to supply a basic thermal data of the pyrolysis gasification characteristics in the plastic-rich SRF which are needed for developing the novel pyrolyser or gasifier. To do so, a bench-scale test rig was newly engineered, and then experiments were achieved for the production characteristics of gas, tar, and char. While SRF sample, gasification air ratio, holding time changed as 2 g, 0.691, 32 min respectively, the $H_2$ 1.36%, $CH_4$ 2.18%, CO 1.88%, $Cl_2$ 15.9 ppm, HCl 6.4 ppm were composed. Also light tar benzene $4.03g/m^3$, naphthalene $0.39g/m^3$, anthracene $0.11g/m^3$, pyrene $0.06g/m^3$, gravimetric tar $18g/m^3$, and char 0.29 g was formed.

Study on the HCl Exhaust and Reduction Characteristics of Refuse-Derived Fuel (폐기물(廢棄物) 고형연료(固形燃料)(RDF) 연소시의 염화수소(鹽化水素) 발생 및 저감 특성 연구)

  • Nho, Nam-Sun;Kim, Kwang-Ho;Jeon, Sang-Goo;Lee, Kyong-Hwan;Shin, Dae-Hyun;Suh, Jee-Mi;Park, Hyo-Nam
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.10a
    • /
    • pp.70-74
    • /
    • 2005
  • 최근에 국내에서 활발히 보급되기 시작한 폐기물 고형연료(Refuse-Derived Fuel : RDF)에 적합한 HCl 배출 저감설비의 개발에 필요한 기본적인 자료를 확보하기 위한 첫 번째 단계로서 RDF 연소시의 HCl 생성 및 저감 특성에 대한 실험실적인 기초 실험을 수행하였다. 개당 무게가 $2{\sim}3\;g$ 정도인 RDF 시료는 실험실적 방법으로 제조하였고, Ca 계통의 흡수제를 선택하여 RDF 중의 Cl 함량 및 원료 조성에 따른 HCl 배출농도 및 흡수제 사용량, Ca/Cl 몰비에 따른 HCl 제거효율, 연소 조건별 생성물질, 반응온도별 HCl 배출농도 및 회재의 Cl 함량, 흡수제별 HCl 저감효율 변화 등을 살펴보았다. 또한 40 kg/hr과 200 kg/hr의 용량을 가진 RDF 연소용 실험설비에서 측정된 HCl 배출농도, RDF의 Cl 함량, 회재 종류별 Cl 함량 분포 등을 기초실험 결과와 비교분석하였다.

  • PDF

Study on applicability of RDF in Municipal Waste Landfill Site (생활폐기물매립장에서의 RDF 적응가능성에 대한 연구)

  • Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.18 no.10
    • /
    • pp.1181-1187
    • /
    • 2009
  • Results for application of RDF(Refuse Derived Fuel) to selected wastes in metropolitan and small and medium cities are as follows. The physical characteristics of waste are paper, plastic, food waste, and so on. The proximate analysis in P city showed 20.2% of moisture, 71% of combustible material, and 8.8% of ash on annual average. That in G city showed 31.6% of moisture, 59.5% of combustible material, and 8.9% of ash. Ultimate analysis in P city showed 52.04% of carbon, 7.02% of hydrogen, 28.80% of oxygen, 0.66% of nitrogen, and 0.09% of sulfur. Heating value was 3,363 kcal/kg. Ultimate analysis in G city showed 50.85% of carbon, 6.56% of hydrogen, 29.86% of oxygen, 0.79% of nitrogen, and 0.12% of sulfur. Heating value in the G city was somewhat lower than that in the P city with 2,632 kcal/kg. Thus, application of RDF in metropolitan city was more effective than that in small and medium cities. Heating value in mixture for the P city was lower than that in waste of the volume rate waste charge system alone by 143 kcal/kg. In proximate analysis, moisture, and combustible material were likely to be more adequate to RDF.

Kinetic Analysis of Isothermal Pyrolysis of Korean Refuse Plastic Fuel for Application to Circulating Fluidized Bed Boiler (순환유동층 적용을 위한 국내 폐플라스틱 고형연료의 등온 열분해 분석)

  • Park, Kyoung-Il;Kim, Dong-Won;Lee, Tae-Hee;Lee, Jong-Min
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.692-699
    • /
    • 2013
  • In this study, isothermal (350, 375, 400, 425, 450, 500, $850^{\circ}C$) experiments were carried out using a custom-made thermobalance to analyze the thermal decomposition properties of refuse plastic fuel (RPF), which is to be used as a cofiring fuel with a sub-bituminous coal at commercial circulating fluidized bed (CFB) boiler in Korea. In isothermal pyrolysis results, no change in the reaction model was observed in the temperature range of $375{\sim}450^{\circ}C$ and it was revealed that the first order chemical reaction (F1) is the most suitable among 12 reaction models. The activation energy shows similar results irrespective of application of reaction model in that the activation energy was 39.44 kcal/mol and 36.96 kcal/mol when using Arrhenius equation and iso-conversional method ($0.5{\leq}X{\leq}0.9$) respectively. Mean-while, the devolatilization time ($t_{dev}$) according to particle size (d) of RPF could be expressed as $t_{dev}=10.38d^{2.88}$ at $850^{\circ}C$, operation temperature of CFB and for even distribution and oxidation of RPF in CFB boiler, we found that the relationship of average dispersion distance (x) and particle size was $x{\leq}1.58d^{1.44}$.

Feasibility Study on Use of Livestock Manure as Solid Refuse Fuel by Torrefaction Method (반탄화 기술을 이용한 가축분뇨의 고형연료화 가능성 연구)

  • Lee, Yongho;Sanjusren, Oyun-Erdene;Pak, Daewon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.560-571
    • /
    • 2019
  • In the study, used torrefaction method to make sample from organic waste of livestock manure for Biomass-solid refuse fuel feasibility study of torrefied materials. Fallen leaves and sawdust added in torrefaction methods with livestock manure, that additives were used to improve the lower calorific value of livestock manure. During the torrefaction experiment, the reaction temperature was varied from $200^{\circ}C$ to $260^{\circ}C$ and $20^{\circ}C$ to prepare a sample. The reaction time was divided into 15, 30 and 45min to determine the effect of the experimental conditions on the torrified products. The additives were mixed at a ratio of 9:1 and 8:2 (Cow manure: additive) relative to the livestock manure. Through this experiment, it was obtained 3,500 kcal/kg standard product of solid fuel produced in Korea and improved product was obtained by adding additives.

Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel (고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석)

  • You, Han-Jo;Jung, Yeon-Hoon;Kim, Jin-guil;Shin, Hyung-Soon;Lim, Yoon-Jung;Lee, Sang-Soo;Son, Hae-Jun;Lim, Sam-Hwa;Kim, Jong-Su
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.719-725
    • /
    • 2020
  • Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 ㎛ diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 ㎛ and larger than 2.5 ㎛, and particulate matter of 2.5 ㎛ or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 ㎛. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.

Development of CO2 Emission Factor for Wood Chip Fuel and Reduction Effects (목질계 바이오매스 중 대체연료 우드칩의 온실가스(CO2) 배출계수 개발 및 저감 효과)

  • Lee, Seul-Ki;Kim, Seung-Jin;Cho, Chang-Sang;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.3 no.3
    • /
    • pp.211-224
    • /
    • 2012
  • Technology for energy recovery from waste can reduce the greenhouse gas emissions. So recently, there are several companies using RDF, RPF, WCF instead of using only coal fuel and it's part of the fuel on the increase. In this study, we developed Wood chip fuel $CO_2$ emission factor through fuel analysis. It's moisture content is 23%, received net calorific value is 2,845 kcal/kg, and received basis carbon is 34%. The result of emission factor is $105ton\;CO_2/TJ$, it's 5.9% lower than 2006 IPCC guideline default factor $112ton\;CO_2/TJ$. The gross GHG(Greenhouse gases) emissions of plant A is $178,767ton\;CO_2 eq./yr$, and Net GHG emissions is $40,359ton\;CO_2 eq./yr$. Therefore, the reduction of GHG emissions is $138,408ton\;CO_2/yr$ through using WCF, and I accounts for 77% of all GHG emissions.

Characteristics Evaluation of Combustion by Analysis of Fuel Gas Using Refuse-derived Fuel by Mixing Different Ratios with Organic and Combustible Wastes (배연가스 분석에 의한 가연성과 유기성폐기물을 혼합한 고형화연료 연소 특성평가)

  • Ha, Sang-An
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.3
    • /
    • pp.27-39
    • /
    • 2009
  • The main objective of this study is to investigate the characteristics of combustion by analyzing fuel gases from a combustion equipment with various combustion conditions for refuse-derived fuels (RDFs). CO gas is a parameter for indicating of incomplete combustion during a combustion process. The lowest CO gas was produced when the experiment conditions were m=2 under air-fuel condition and $800^{\circ}C$. $CO_2$ gas is a final product after complete combustions. The highest amount of $CO_2$ gas was produced when the experiment conditions were m=2 under air-fuel condition and $800^{\circ}C$. The highest level of $SO_2$ gas was produced in S.1 sample containing the highest sulfur. The highest level of NOx gas was produced in S.1 sample with the highest nitrogen content and air-fuel condition of m=2 under temperature of $800^{\circ}C$. HCl gas that is generated by reacting with metals catalyst through oxygen catalyst reaction during combustion process is a precursor of dioxin formation. The higher level of HCl gas was produced in the sample with higher chlorine content. The lowest level of HCl gas was produced when the experiment conditions were air-fuel condition of m=2 and $800^{\circ}C$. The lowest level of $NH_3$ gas was generated when the experiment condition was m=2 under air-fuel condition and after 3 minutes. Air-fuel condition is more important to create $NH_3$ gas than operating temperatures. Higher level of $H_2S$ gas was generated in S.1 sample with the higher sulfur content and was created in RDFs that contain higher mixture ratios of sewage sludge and food wastes. A result of combustion, gases and gases levels from the combustion of S.1 and S.2 were very similar to the combustion of a stone coal. As results of this research, when evaluating the feasibility of the RDFs, the RDFs could be used as auxiliary and main fuels.

Study on the Pyrolysis Kinetics of RDF(Refuse Derived Fuel) with Thermogravimetric Analysis (열중량 분석 기법을 통한 RDF의 열분해 특성 조사)

  • Kim, Dong-Won;Lee, Jong-Min;Kim, Jae-Sung
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.676-682
    • /
    • 2009
  • Devolatilization of the Refuse Derived Fuel(RDF) which is produced at WonJu in Korea was characterized in air atmosphere with variation of heating rate(10, 20 and $30^{\circ}C/min$) in TGA. The results of TG Analysis have shown that the pyrolysis and char combustion of the RDF occurred in the range of $350{\sim}700^{\circ}C$ depending on the heating rate. Activation energy of the RDF which was determined by using Friedman and Ozawa-Flynn-Wall method was in the range of 14.44~18.40 kcal/mol. Also, reaction order(n) and pre-exponential factors(A) were 1.219 and $3.02{\times}10^5$ by using Friedman method, respectively. In order to find out the devolatilization mechanism of the RDF, twelve solid-state mechanisms defined by Coats Redfern Method were tested. The results of the Coats Redfern Method have shown that chemical reaction is the effective mechanism by comparison with the value of the activation energy which was derived from the Friedman and Flynn-Wall-Ozawa method and correlation coefficient from twelve solid-state mechanisms of Coats Redfern Method. The solid state decomposition mechanism of the RDF was found to be a decelerated $F_1$ type, random nucleation with one nucleus on the individual particle.