초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구 (A Study on the Improvement of the Refuge safety area in High-rise Buildings Type)

  • 이병현;이경희
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.

초고층 건축물 화재시 피난공간 기준 제안에 관한 연구 (A Study on Proposal of the Refuge Area Standard in Super-High-Rise Building Fire)

  • 박상규;노삼규
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.76-79
    • /
    • 2008
  • 본 연구에서는 초고층 건축물에서의 화재 발생시 피난상의 문제점을 분석하여 재실자의 안전을 도모할 수 있는 수단으로서 피난공간을 제시하고 필요성을 고찰하였다. 또한 피난공간의 기준 마련을 위해서 고려해야 할 인자들을 도출하고 도출된 인자들을 각각의 해결방안에 의한 논증을 통해 피난공간의 기준을 제안하였다.

  • PDF

오피스 빌딩의 한국과 중국 피난관련 법 검토에 따른 개선 연구 (A Study on Improvement According to Korea and China Evacuation Laws in Office Building)

  • 이병현;이경희
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.51-56
    • /
    • 2017
  • In the case of office buildings, domestic and Chinese evacuation laws were compared regarding the evacuation of horizontal and vertical buildings and evacuation to refuge safety areas. A simulation was conducted based on a refuge safety area in China. In the case of evacuating 1 floor, there was no significant difference in the flow of occupants to an ancillary room area in a domestic or Chinese building, but in China, the corridor width was narrower and the occupants have saw a long. In the case of evacuating 15 floors, the flow of occupants to an ancillary room area was different. In the case of China, it was possible for occupants to enter the ancillary room more quickly because the ancillary room area was wider than those found in domestic buildings, allowing quickly passage the ancillary room door. The results of this study found that if corridor width and ancillary room area were wider, evacuation times could be reduced.

제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구 (Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control)

  • 이재빈;문주현;이성혁;유홍선
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.103-109
    • /
    • 2011
  • 본 연구에서는 초고층 건축물 화재 시 피난 안전 구역이 있는 피난 층에서 화재실로부터 발생하는 연기의 거동을 파악하기 위하여 상용코드를 사용하여 수치해석을 하였다. 화재를 모사하기 위하여 10 MW의 발열량에 해당하는 온도와 속도를 이용하여 부력 plume을 적용하였으며 종 보존 방정식을 이용하여 화재 연기 거동을 예측하였다. 피난 안전 구역에 제연 댐퍼를 설치하여 급기 가압 제연 시스템을 적용하였으며 화재실 문이 열린 경우 25 $m^3/s$, 화재실과 부속실 문이 동시에 열린 경우 50 $m^3/s$의 제연 댐퍼송풍량은 화재 안전 기준 NFSC 501-A를 만족하며 충분히 제연이 가능하다는 것을 확인하였다. 부속실문이 열린 경우, 화재실의 문이 닫혀 있더라도 문과 벽 사이의 틈새 면적으로 연기가 피난 안전 구역으로 유입될 가능성이 있다. 또한, 50 $m^3/s$ 높은 송풍량으로 제연 중 화재실 문이 닫힐 경우 피난자가 화재실에 고립될 가능성을 확인하였다. 그러므로 피난자의 안전을 위해 제연 송풍량의 조절이 필요하며 본 연구에서는 피난 시나리오에 따른 적절한 송풍량을 제안한다.

노인요양병원에서 고령자의 수평 피난을 고려한 대피공간의 건축계획에 관한 연구 (A Study on the Architectural Planning of the Refuge Areas in Geriatric Hospitals Considering Horizontal Evacuation of the Elderly)

  • 김미정;권지훈
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권3호
    • /
    • pp.7-15
    • /
    • 2023
  • Purpose: This study was conducted with the aim of presenting spatial planning directions for evacuation spaces based on an analysis of the performance of horizontal evacuation during the early stages of fire incidents in a geriatric hospital. Methods: Based on a review of previous studies, the research model was designed by establishing occupancy conditions, evacuation, and fire scenarios. The analysis model was developed by considering vulnerable areas in terms of evacuation movement and analyzing the results of evacuation performance. Furthermore, the study analyzed the improvement in evacuation performance by arranging refuge areas. Results: The results of the study are as follows. Firstly, vulnerability spots were identified in terms of evacuation performance by schematizing Required Safe Egress Time, Available Safe Egress Time, and their differences. Secondly, the Required Safe Egress Time in the adjacent public spaces along the escape routes of occupants was found to be higher compared to the Available Safe Egress Time. Thirdly, the results of the correlation analysis between the difference in Available Safe Egress Time and Required Safe Egress Time during the early stages of a fire, as well as their constituent factors, demonstrated that user congestion is a more significant factor in compromising evacuation safety than the physical changes in the fire condition. Fourthly, the analysis of evacuation time was conducted by designating refuge areas where occupants can evacuate within a sufficient timeframe. This led to a decrease in the Required Safe Egress Time. Implications: This study is expected to be used as data on the direction of evacuation space planning to improve the evacuation performance of Geriatric Hospital.

급기가압 제연시스템의 방연풍속 형성특성에 대한 수치해석적 분석 (Numerical Analysis on Features of Airflow through Open Door in Pressure Differential System)

  • 김정엽;이동호;김하영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.463-468
    • /
    • 2008
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. In pressure differential systems for smoke management, the speed of airflow through open door between accommodation and lobby should be maintained over 0.5m/s on the whole area of door to prevent smoke from infiltrate into evacuation root when the door is open for refuge. The numerical analysis on features of airflow through open door are carried out and the results are presented.

  • PDF

부속실 급기가압제연시 차압변화에 관한 실험적 연구 (An Experimental Study on the Pressure Differentials during the Pressurized Air Supply to the Elevator Lobby)

  • 김범규;박용환;김홍식
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.110-119
    • /
    • 2009
  • A fire should be accompanied by the heat and smoke. However, smoke is considered main cause of heavy casualties. Smoke easily spreads away from the fire area to remote space and cause mortal wound for the resident. A technical way effectively protecting the life and property from the smoke is the smoke control system of the building. Pressurized air supply system can be considered to prevent the refuge area from the smoke infiltration that evacuate residents via evacuation route for life safety. This paper is related with performance estimation and the effectiveness of the pressurized air supply system through experiments.

  • PDF

진해만 태풍 피항지 정박 선박간 이격거리 설정에 관한 연구 (Study on the Establishment of the Separation Distance between Anchored Ships in Jinhae Bay Typhoon Refuge)

  • 강원식;김지윤;김대원
    • 해양환경안전학회지
    • /
    • 제29권4호
    • /
    • pp.338-347
    • /
    • 2023
  • 진해만은 태풍 내습 시 피항 선박이 폭주하고 강한 바람 등의 영향으로 주묘가 자주 발생하며 이에 따른 선박 간 충돌 및 좌초 등 해양사고 발생 개연성이 매우 높다. 본 연구에서는 우리나라 해역 특성에 맞는 진해만 정박지의 선박 간 안전이격거리 설정을 위한 연구를 수행하였다. 진해만 태풍 피항지에는 태풍 내습 시 평균 100 ~ 200여척의 선박이 정박을 하고 있으며 풍속이 25m/s 이상되는 강한 외력에서 전체 선박의 약 70%에 주묘가 발생하는 상황인 것으로 분석되었다. 본 연구에서는 국내외 설계기준 상 제시된 황천 시 정박 선박간 이격거리, 실제 피항지로서 사용된 진해만 피항선박 간 이격거리, 강한 외력에 따른 선박 표류 시 적정 안전거리 등을 분석하여 제시하였다. 그 결과 설계기준 상의 최소 기준과 비상조치 시간을 고려하여 약 400 ~ 900m의 안전이격거리가 필요하며, 공간상의 여유가 있는 경우에는 700 ~ 900m 이격거리 설정이 필요한 것으로 도출하였다. 본 연구의 결과는 향후 진해만 피항지를 이용하는 선박에 대해 선박간 안전 이격거리를 위한 지침 수립 시 활용이 가능할 것으로 기대된다.

초고층 건축물 피난안전구역 관련 기준의 개선을 위한 개념적 연구 (A study on the code improvement about the refuge safety area in high-rise buildings)

  • 한명신;박재성;최영관
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.149-154
    • /
    • 2010
  • 건축기술의 눈부신 발전과 경제적 가치추구 등에 따른 국가 사회적 수요로 인하여 초고층 건축물의 건설물량은 이들 건축물에 대한 효과적인 피난안전대책을 정립하기도 전에 급속히 증가하는 추세이다. 우리나라는 2009년 7월 16일 재정된 건축법 시행령을 통하여 층수가 50층 이상이거나 높이가 200미터 이상인 건축물을 '초고층 건축물'로 규정하고, 이러한 건축물의 피난안전을 위하여 지상층으로부터 최대 30개 층마다 설치하는 대피공간을 '피난안전구역'으로 정의하였다. 이후 2010년 2월 18일 개정령에서는 초고층 건축물의 피난안전구역을 건축물의 '피난층'으로 인정하기에 이르렀다. 그러나 피난대상인원 등에 따른 대피공간의 면적이나 구조 등 내부시설에 대한 설치기준이 없어 피난안전구역으로서의 충분한 신뢰성을 확보하지 못하고 있어 이에 대한 심층적 연구와 기준의 개선이 필요한 실정이다.

  • PDF

당재길 걷고싶은 녹화거리 설계 (The Walkable Green Street Design for "Dangjae-Gil")

  • 김성균
    • 한국조경학회지
    • /
    • 제30권1호
    • /
    • pp.52-60
    • /
    • 2002
  • This paper presents a streetscape design for "Dangiae-Gil"which is located at 126-1 Yangpyung-2dong, Yeongdeungpo-gu, Seoul and is about 500m in length and about 24m in width. The design goals are to make a green street on which people want to walk and people can walk and rest safely and pleasantly. To achieve these goals, concepts of environmentally-friendliness, placeness, safety, amenity, vitality, connectivity, and democracy are developed. For pedestrian safety, shared street concepts, such as crank, slalom etc. are adopted. The site is divided into 5 thematic spaces, such as "Village Entrance Space", "Culture Street", "Dangsan Park", "Nature Street", and "Ferry Space". The Village Entrance Space, which is an entrance of the Dangjae-Gil and a welcoming space, is for communicating information about the area. "Dangnamu"(zelkova tree) and signs are introduced here. The Culture Street is for experiencing past and present culture of the area. Colored tiles and plant boxes attached to benches are introduced. The Dangsan park is a sacred space where modem people can feel the sacredness of nature arid of being in a refuge. Dangjib, Dangnamu, multi-purpose plaza, athletic facilities, and playground for infants are introduced. The Nature Street is a space for feeling and teaming nature which has disappeared from the area leading to the river and a space for community participation. The elementary school walls were demolished and nature education spaces, such as butterfly and dragonfly garden, ecological pond, wildflower garden, etc., which are related to school education, are introduced. The Ferry Space is a space symbolizing a old ferry crossing and an entrance plaza to a bridge for "Sunyu-do\" . A boat-shaped deck, an elevator for handicap people, and parking space are introduced. In conclusion, sustainable management schemes for the site are suggested.sted.