• 제목/요약/키워드: Refrigerator evaporator

검색결과 53건 처리시간 0.032초

냉장고 특성 시뮬레이션 (Simulation of Refrigerator Characteristics)

  • 문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.181-189
    • /
    • 1998
  • A general steady-state model for simulation on domastic refrigerator has been developed. The system model consists of various standard components such as evaporator compressor condenser capillary tube and cabinet. Cabinet is not system component but influence characteristic on domastic refrigerator. The purpose of this paper is to compare between characteristics of HFC 134a with CFC 12 in the domastic refrigerator and to predict the steady state cycle performance which is various specifications of cycle components under the continuous running conditions. As the results of simulation the coefficient of performance of both condenser and evaporator increases with increasing UA the increasing rate for condenser is greater than for evaporator.

  • PDF

나선형 핀-튜브 증발기를 적용한 냉장고의 성능 특성에 관한 연구 (Study on Performance Characteristics of Spiral Fin-Tube Evaporator Applied to Domestic Refrigerator-Freezers)

  • 이상헌;윤원재;김용찬;이무연;윤성중
    • 대한기계학회논문집B
    • /
    • 제37권3호
    • /
    • pp.205-212
    • /
    • 2013
  • 본 연구는 평판 핀-튜브 증발기와 나선형 핀-튜브 증발기를 적용한 가정용 냉장고의 성능특성 비교를 통하여 기존에 사용하고 있는 핀-튜브 증발기를 나선형 핀-튜브 증발기로 대체할 수 있는 가능성을 고찰하는데 그 목적이 있다. 실험은 2단 15열의 평판 핀-튜브 증발기와 2단 15열에서 2단 11열까지 열 수를 단계적으로 감소시킨 3종류의 나선형 핀-튜브 증발기를 실제 냉장고에 적용하여 수행하였다. 핀-튜브 증발기의 열 수가 감소할수록 냉동시스템의 최적 냉매 충전량은 감소하였으며, 2단 13열과 2단 11열의 나선형 핀-튜브 증발기를 장착한 냉장고의 소비전력은 기존 2단 15열의 평판 핀-튜브 증발기를 적용한 냉장고 대비 각각 1.5%와 2.8% 감소하였다. 또한 내착상 실험결과 나선형 핀-튜브 증발기가 기존 평판 핀-튜브 증발기와 비교하여 같은 착상조건에서 3~7% 향상된 냉각능력을 보였다. 냉각속도 실험에서는 모든 증발기는 동등수준의 성능을 나타내었다.

냉장고용 핀-튜브 증발기의 착상 성능해석에 관한 연구 (Numerical Analysis on the Frosting Performance of a Fin-tube Evaporator for a Refrigerator)

  • 이무연;이호성;장용희;김용찬
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.307-316
    • /
    • 2008
  • The objective of this study is to provide numerical and experimental data that can be used to investigate the performance characteristics of a flat plate fin-tube evaporator in household and commercial refrigerators under frosting conditions. Computer simulations with variations of operating conditions such as air inlet temperature, relative humidity, and geometries were performed to find out optimal design parameters of a fin-tube evaporator for household and commercial refrigerators. The tube-by-tube method was used in the simulation and the frost growth model was considered under frosting conditions. The developed analytical model predicted the decreasing rates of heat transfer capacity and air flow rate ratio within ${\pm}$10% compared to the experimental results for a refrigerator under real operating conditions. As a result, the frost thickness at $3^{\circ}C$ & 80% is increased 40% than that of $-3^{\circ}C$ & 80%, and the frost thickness at $3^{\circ}C$ & 90% is increased 30% than that of $3^{\circ}C$ & 60%. Accordingly, the operating time of the evaporator in the refrigerator was reduced with the increase of the decreasing rate of air flow rate ratio at each condition.

대체냉매를 이용한 가정용 냉장고의 시스템 특성에 관한 연구 (An investigation on the system characteristics of a refrigerator with alternative refrigerants)

  • 신진규;문춘근;윤정인
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.753-762
    • /
    • 1998
  • A domestic refrigerator is composed of many components such as a compressor, evaporator, capillary tube, and the cabinet which plays a great role on the cycle performance, even if it is not the basic component part in the cycle. Recently, the restriction policy on the energy-saving and environmentally friendly refrigerator is reinforced in our nation as well as developed countries. Therefore, in this paper, cycle simulations and experiments were carried out ito understand the characteristics of the cycle performance using CFC 12, HFC 134a, and HC 600a and to know how changes in UA(overall heat transfer coefficients$\times$ heat transfer area) of evaporator, the position displacement of compressor, and the rpm of fan in the freezing room which has influence on the cycle performance. The result shows that the quantitative values of simulation and experiment are not coincident, but their trend is similar. When HFC 134a and HC 600a were used without the change of design in refrigerator used CFC 12, the performance of system in HC 600a is 30% lower, and the case of HFC 134a is 10% lower than that of CFC 12 on freezing temperature.

  • PDF

공기분사식 제상장치 개발에 관한 실험적 연구 (Experimental Study for Development of Air Eject Defrost Equipment)

  • 한인근;김창영;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

이산화탄소 냉매를 이용한 냉동탑차용 핀-관 증발기의 서리성장에 따른 열교환기 성능에 관한 해석적 연구 (Theoretical Study on Heat Exchanger Performance of a Fin-tube Evaporator with Frost Growth in a $CO_2$ Refrigerator Truck)

  • 명치욱;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.48-54
    • /
    • 2012
  • To analyze the cooling performance of fin-tube evaporator in the refrigerator truck using R744 according to frost growth, the analytical model of evaporator was developed under frost and non-frost conditions. The performance of fin-tube evaporator was investigated with frost thickness and indoor temperature. Besides, the performance of evaporator under frost condition was compared to that under non-frost condition. As a result, area of air passage and system performance were decreased as the frost thickness increased. The cooling capacity was reduced by 10%, 20%, 30% when the frost thickness was 0.7 mm, 1.1 mm, and 1.6 mm respectively. At these conditions, the block ratio was 31%, 48%, and 71%. In addition, the outlet quality of refrigerant was not over 1 when the frost thickness was 1.6 mm in spite of high indoor air temperature.

냉동기용 지능형 진단시스템의 개발 (Development of Intelligent Diagnostic System for Refrigerator)

  • 임대영;유재영
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2004년도 춘계학술대회 학술발표 논문집 제14권 제1호
    • /
    • pp.25-28
    • /
    • 2004
  • This paper describes an intelligent diagnostic system for the refrigerator which is used for the cold-storage of farm produce. The propose method measures the temperature of the compressor, condenser and evaporator in the refrigerator and uses the measured values to diagnose the system. It is shown through the implementation that the developed system is efficient for the fault observation and diagnose of the refrigerator.

  • PDF

냉장고 내부의 냉기 유동특성에 관한 3차원 해석(I) (3-Dimensional Calculation on Cold Air Flow Characteristics in a Refrigerator)

  • 오민정;이재헌;오명도
    • 설비공학논문집
    • /
    • 제7권3호
    • /
    • pp.382-395
    • /
    • 1995
  • A numerical study has been performed on flow characteristics in a domestic refrigerator whose size is $540mm{\times}1,530mm{\times}680mm$, considering existence of a fan and evaporator. The flow field has been simulated with the low Reynolds number $k-\bar{\varepsilon}$ turbulent model and SIMPLE algorithm based on the finite volume method. The region of fan which makes driving force for cold air distribution was modeled as a region in which momentum sources are generated uniformly. The concept of the distributed pressure resistance was applied to describe the momentum loss from evaporator. The result showed that the rate of cold air distribution into freezing room and cold storage room was almost 7 : 3.

  • PDF

R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구 (Performance characteristics of a multi type refrigerator)

  • 안지훈;장용희;김용찬;장의영;박용종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.292-297
    • /
    • 2008
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi function refrigerator which has different purposes in each evaporator. In this study, the performance of a multi type refrigerator system, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator system was tested by varying the number of refrigerator cabinet, refrigerant charge amount, temperature condition. Based on experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type) At the same external load condition, the COP of the multi type refrigerator was $1.22{\sim}1.29$, but the COP of the single type refrigerator was 1.0.

  • PDF

플레이트 휜 코일형 증발기의 착상에 관한 기초 실험 (Basic Experiment on Frost of Plate Fin Coil Evaporator)

  • 백승문;김창영;한인근;김재돌;윤정인
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.211-216
    • /
    • 1999
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. In this report, a prediction taking into account the change of the fin efficiency due to the growth of the frost layer.

  • PDF