• 제목/요약/키워드: Refrigeration Effect

검색결과 849건 처리시간 0.025초

Numerical Analysis of Vertical Plate Absorber for Optimal Design

  • Yoon, Jung-In;Moon, Choon-Geun;Phan, Thanh-Tong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.252-262
    • /
    • 2004
  • A model of simultaneous heat and mass transfer process in absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber. which was considered to the change of refrigerant vapor pressure along the plate width direction. was developed to evaluate the compactness of plate absorber and supply basis data for optimal design of plate absorber. The effects of plate interval as well as the effect of capacity for one piece of plate absorber on plate absorber size such as plate height. plate heating area and plate absorber volume have been investigated. It is confirmed that there is exist an optimal plate interval minimizing plate absorber volume. And the smaller capacity for one piece of plate absorber. the smaller plate absorber volume is obtained.

냉장고 사이클 특성에 미치는 열손실량의 영향 (Effect of heat Leak on Cycle Characteristics of Refrigerator)

  • 신진규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.871-879
    • /
    • 1998
  • The refrigerator consists of many components such as compressor condenser expansion valve evaporator and the cabinet which filled by urethane foam. In this paper the heat leakage of refriger-ator is measured by the new experiment method which is different from a present method, The devi-ation of the UA(overall heat transfer coefficient times area) between the simulation and experiments is about 7-8%. Using the modeling of various components of refrigeration system a performance analysos of CFC 12 and HFC 134a is performed numerically on the UA. As the results of this study according to increase the heat leakage the refrigeration load and mass flow rate of refrigerant are increased. And the increase of the mass flow rate results in the increase of the condensing and evapo-rating temperature. Therefore according to increase of the heat leakage the COP leads to increase because the increase of refrigeration capacity is larger than the increase if compressor power.

  • PDF

인버터 열펌프내 오일순환량에 관한 실험적 연구 (An Experimental Study on the Oil Circulation in an Inverter-Driven Heat Pump)

  • 민만기;홍기수;황윤제;황일남;김철민;조관식
    • 설비공학논문집
    • /
    • 제12권8호
    • /
    • pp.717-724
    • /
    • 2000
  • It is important to investigate characteristics of flow of refrigerant/oil mixture circulating in a refrigeration system. Therefore the oil concentration in refrigerant/oil mixture should be measured exactly by the adequate measuring instrument. In this paper, the oil concentration was measured by density monitoring system(DMS) in the liquid-line of a inverter-driven heat pump. Experimental result follows ; the main factor that have an effect on oil concentration refrigerant/oil mixture circulating in a refrigeration system is the momentum and kinematic viscosity of refrigerant/oil mixture compressed by scroll compressor.

  • PDF

LiBr작동유체 중에서 가스흡수식 냉온수기의 국부부식 특성에 관한 연구 (A Study on the Characteristics of Local Corrosion for Gas Absorption Refrigeration and Hot Water Systems in LiBr-$H_2O$ Working Fluids)

  • Uh- Joh Lim;Ki-Cheol Jeong;Byoung-Du Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.714-720
    • /
    • 2003
  • Due to the electric power shortage in summer season and regulation of freon refrigerant, the application of gas absorption refrigeration and hot water systems are considerably increasing trend. But, this system consists of condenser, heat exchanger, supply pipe and radiator etc. which are easily corroded by acidity and dissolved oxygen and gases. In result, this system occurs scale attachment and corrosion damage like pitting and crevice corrosion. In this study, electrochemical polarization test of heat exchanger tubing material (copper, aluminium brass, 30% cupronickel(30% Cu-Ni)) was carried out in 60% lithium bromide solution at $95^{\circ}C$. As a result of polarization test, corrosion behavior by impressed potential and local corrosion. such as galvanic corrosion, pitting corrosion behavior, of tubing materials was investigated. The main results obtained are as follows: (1) The effect of pitting and crevice corrosion control of 30% cupronickel in 60% LiBr solution at $95^{\circ}C$ is very excellent. (2) Dissimilar metal corrosion of 30% cupronickel coupling to aluminium bronze is the most sensitive. (3) Current density behavior of tube materials by impressed potential is high in order of copper > aluminium brass > 30% cupronickel.

가변속 증기압축 냉동시스템에서 고장시의 성능변화와 고장 감지 및 진단에 관한 연구 (Studies on the Performance Variation of a Variable Speed Vapor Compression System under Fault and Its Detection and Diagnosis)

  • 김민성;김민수
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.47-55
    • /
    • 2005
  • An experimental study has been peformed to develop a scheme for fault detection and diagnosis(FDD) in a vapor compression refrigeration system. This study is to analyze fault effect on the system performance and to find efficient diagnosis rules for easy determination of abnormal system operation. The refrigeration system was operated with a variable speed compressor to modulate cooling capacity. The FDD system was designed to consider transient load conditions. Four major faults were considered, and each fault was detected over wide operating load range by separating the system response to the load change. Rule-based method was used to diagnose and classify the system faults. From the experimental results, COP degradation due to the faults in a variable speed system is severer than that in a constant speed system. The method developed in this study can be used in the fault detection of refrigeration systems with a variable speed compressor.

통기벽체적용 건물에서의 일사열 제거효과 검토 (A Study of Solar heat removal Impact with Air-Vent Wall)

  • 김상진;금종수;최광환;신병환;정용현
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.25-31
    • /
    • 2004
  • Ventilation through air vent system in a building envelope is expected to be an effective measure to release solar radiation. An external surface of a wall absorbs solar radiation and transfers it to the air in the cavity. The warmed air gets buoyant force. So when openings are provided at the top and bottom of the cavity, the warmed air is released through the top opening and cooler outside air replaces the space in the cavity. This reduces the further heat transmission into the built environment. This natural ventilation effect seems to be steady and strong. So because of the cavity and the openings, the cooling load reduction by natural ventilation is believed to be considerable.

소고기 분쇄육의 냉장 중 품질에 미치는 항산화제의 효과 (Effect of Antioxidant on Quality of Ground Beef during the Refrigeration Storage)

  • 김병숙;이영은
    • 한국식품영양학회지
    • /
    • 제24권3호
    • /
    • pp.422-433
    • /
    • 2011
  • The objective of this study was to evaluate their effects as the meat antioxidant and on the antioxidant enzymes like superoxide dismutase(SOD) and catalase during the refrigeration storage of ground beef, respectively. Ground beef loin was treated by three natural antioxidants(pycnogenol, catechin, ${\alpha}$-tocopherol) and the synthetic antioxidant(BHT) at the level of 0.01%(w/w) of total fat. Samples were refrigerated at $4{\sim}6^{\circ}C$ for 3, 5, 7 and 10 days to evaluate the color and the pH as the quality parameters, TBA value and fatty acid composition as the parameters of lipid peroxidation, and the activities of SOD and catalase. This study showed that catechin and pycnogenol were excellent in terms of meat color, pH and delaying lipid peroxidation and also maintained the activity of in vivo SOD and catalase better than ${\alpha}$-tocopherol and BHT. These results suggested that the duration of the refrigeration of ground beef may be prolonged up to 10 days in catechin and pycnogenol treated ones in terms of the lipid peroxidation, but 5 days of refrigeration will be more adequate if considering the microbial safety as food, too.

증기-액 이젝터를 적용한 해양온도차발전 시스템의 성능 특성 (Performance Characteristics of OTEC(Ocean Thermal Energy Conversion) Power Cycle with Vapor-Liquid Ejector)

  • 윤정인;손창효;김현욱;하수정;이호생;김현주
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.88-93
    • /
    • 2014
  • In this paper, the performance analysis of condensation and evaporation capacity, turbine work and efficiency of the OTEC power system using vapor-liquid Ejector is presented to offer the basic design data for the operating parameters of the system. The working fluid used in this system is $CO_2$. The operating parameters considered in this study include the vapor quality at heat exchanger outlet, pressure ratio of ejector and inlet pressure of low turbine, mass flow ratio of separator at condenser outlet. The main results were summarized as follows. The efficiency of the OTEC power cycle has an enormous effect on the mass flow ratio of separator at condenser outlet. With a thorough grasp of these effects, it is possible to design the OTEC power cycle proposed in this study.

$CO_2$ 사이클용 로타리 베인 팽창기 성능해석 (Performance Analysis of Vane Rotary Expander for $CO_2$ Cycles)

  • 김호영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.55-62
    • /
    • 2009
  • Relatively low cycle performance of a conventional $CO_2$ system is partly due to significant increase in friction loss in the expansion process, since the pressure drop across the expansion device is considerably large compared to a conventional refrigeration cycle. To recover friction loss and increase refrigeration effect by providing isentropic expansion, a rotary vane type expander has been designed. Performance of the designed expander has been investigated by numerical simulation. With the pressure condition of 9 MPa/4.5 MPa and inlet temperature of $35^{\circ}C$, volumetric, isentropic, and mechanical efficiencies of the expander are calculated to be 58.1%, 101.1%, and 78.8%, respectively, resulting in total expander efficiency of 46.3%. With this expander, COP of a $CO_2$ refrigeration cycle is estimated to be improved by about 14%.

Application of an Electric Field Refrigeration System on Pork Loin during Dry Aging

  • Park, Sin-Young;Kim, Hack-Youn;Choe, Juhui
    • 한국축산식품학회지
    • /
    • 제39권4호
    • /
    • pp.668-676
    • /
    • 2019
  • This study aimed to investigate the effect of an electric field refrigeration (EFR) on the quality characteristics of pork loin including dry aging loss, pH, water holding capacity (WHC), cooking loss, color, shear force, thiobarbituric acid reactive substances (TBARS), and microbial growth during dry aging (0, 1, 2, 3, 4, 7, and 9 wk) in comparison with a commercial refrigerator (CR). Total plate counts (TPC) of the CR group approached 8.07 Log CFU/g at 2 wk of dry aging, thus indicating meat spoilage. Cooking loss, lightness, and shear force of EFR were significantly decreased (p<0.05) at subsequent aging weeks in both the EFR and CR. Aging loss, TPC, TBARS levels increased at subsequent aging weeks; however, pH values were not influenced by aging. At the same aging weeks (1 or 2 wk), the EFR group displayed significantly lower values (p<0.05) of aging loss, pH, TPC, and TBARS levels than the CR group. No significant differences in WHC, cooking loss, and shear force was observed until 2 wk of aging between the EFR and CR groups. The present results show that application of the EFR system improves the tenderness, color, and lipid oxidation stability of pork loin and extends its shelf life in comparison with a commercial refrigeration.