• 제목/요약/키워드: Refrigeration Effect

검색결과 849건 처리시간 0.025초

장기간 사용한 12%Cr강 보일러 튜브의 산화스케일에 관한 연구 (A Study on the Oxide Scale of the Long Term Serviced 12%Cr Boiler Tube Steel)

  • 김범수;민택기
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.281-287
    • /
    • 2012
  • The internal oxide scale of twelve superheater and reheater tubes were tested which were serviced for 30,000~120,000 hours in thermal power plants. The oxide scale was formed in three layers. The Cr-rich area was observed beneath the original metal surface. The hematite ($Fe_2O_3$) phase was formed on the outer surface. The intermediate layer was magnetite ($Fe_3O_4$). The thickness of Cr-rich layer was about half of the total scale. All layers grew during the operation hour of the plant. The thickness of thickest scale was 0.2mm in superheater tubes. This can increase the tube metal temperature about $7^{\circ}C$ more than initial state. $7^{\circ}C$ tube metal temperature can reduce tube life about 30%, but the boiler tube's design margin is big enough therefore it has been analyzed that it would not effect on the life span.

두 개의 뜨거운 원형 실린더가 존재하는 사각형 실린더 내부의 자연대류에 관한 수치적 연구 (A Numerical Study of Natural Convection in a Square Enclosure with two Hot Circular Cylinders)

  • 박성현;박용갑;하만영;윤현식;손창민
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.247-255
    • /
    • 2012
  • Numerical calculations are carried out for the natural convection in a square enclosure with two hot cylinders induced by temperature difference between a cold outer rectangular cylinder and two hot circular cylinders. A two-dimensional solution for unsteady natural convection is obtained, using the immersed boundary method (IBM) to model two inner circular cylinders based on finite volume method, for different Rayleigh numbers varying over the range of $10^3$ to $10^5$. The study goes further to investigate the effect of the location of two cylinders on the heat transfer and fluid flow. The location of inner circular cylinders is changed vertically along the center-line of square enclosure. The changes of heat transfer quantities have been presented.

액체 제습식 냉방 시스템의 최적 설계 (Optimization Design of Liquid Desiccant Cooling System)

  • 전동순;이상재;김선창;김영률;이창준
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

유기성 폐자원 바이오에너지 시스템의 공동주택 적용 타당성 평가에 관한 연구 (The Feasibility Analysis of Organic Waste Bioenergy System in Apartment Complex)

  • 고명진;최미영;최두성;김용식
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.474-481
    • /
    • 2010
  • Because international environmental and energy problems such as global warming and ozone depletion, exhausting of fossil energy sources are more serious than before, renewable energy system is attracting people's attention more and more. Organic waste bioenergy system among a variety of renewable energy system is expected to have an effect on building a society which is eco-friendly and recycles resources owing to carbon neutral effects. So this is considered as the role of an energy source of the building. Previous studies on the organic waste bioenergy are mainly bioenergy technology and activation plan of the bioenergy supply. But the performance evaluation studies of bioenergy systems installed in buildings are rarely. This study is to evaluate applicability of the organic waste bioenergy system as the building energy supply system by energy and environmental, economical analysis.

업무시설용 건물 적용 복합 지열원 공조시스템의 경제성 평가 및 한미 요금 비교 (Economic Feasibility of Various HVAC Systems for Commercial Building and Comparison of Energy Tariffs between Korea and USA)

  • 고재윤;박률;서동현
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.599-607
    • /
    • 2008
  • In this study, air conditioning systems include ground source heat pump (GSHP), are evaluated for economic feasibility. The building is modeled an air conditioned for 280kW scale. This analysis is compared with the energy tariff programs of Korea and USA. The objectives of this paper are to evaluate the cost-effectiveness of the GSHP and combined system using Life-Cycle Cost (LCC) analysis, and to carry out the sensitivity analysis of key parameters. The paper considered the cases including the base case of air source heat pump and the other two alternates for comparisons. The combined system is not only a cost-effective way to the low energy consumption but also a way to avoid a high initial investment. The variations of initial investment and energy rates give a significant effect on the total LCC and payback period.

외기 온습도 조건에 따른 폐열회수 환기장치의 열전달 특성 및 불확실성에 관한 연구 (A Study on Heat Transfer Characteristics and Uncertainty of Heat Recovery Ventilator for Various Outdoor Temperature/Humidity Conditions)

  • 한화택;추연복
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.608-613
    • /
    • 2008
  • The purpose of the present paper is to investigate the effect of outdoor weather conditions on the performance of a heat recovery ventilator. Experiments have been performed by varying outdoor temperature/humidity conditions with the indoor conditions fixed at the standard conditions by KARSE. Results indicate humidity efficiency shows larger uncertainties than temperature efficiency in general. With the heat generation by an internal fan removed, the modified temperature efficiency remains almost constant regardless of the indoor-outdoor temperature difference. The enthalpy efficiency can have very large or negative values in case the outdoor conditions are in the vicinity of the indoor enthalpy line. The direction of heat flow, in such a case, can be opposite to that of moisture flow between two air streams. Discussions are included about various interesting features of the psychrometric processes taking place in a heat recovery ventilator.

분리막 제습공조시스템의 잠열부하 저감효과 예측 (Prediction of Latent Heat Load Reduction Effect of the Dehumidifying Air-Conditioning System with Membrane)

  • 정용호;박성룡
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.15-20
    • /
    • 2017
  • The summer climate is very hot and humid in Korea. The humidity is an important factor in determining thermal comfort. Recently, the research for dehumidification device development has been attempted to save energy that is required for the operation of the current dehumidifiers on the market. Existing dehumidification systems have disadvantages such as wasting energy to drive a compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature so it doesn't have to consume cooling energy. In this paper, the cooling energy savings was studied when a dehumidification system was applied in a model building instead of a chiller. The sensible heat load was almost the same result, but the latent heat load was decreased by 38.9% and the total heat load was decreased by 8.5%. As a result, electric energy used to drive the compressor in a chiller was saved by applying a membrane air-conditioning system instead.

Planning of the Blind Position Considering Thermal Performance in the Intermediate Space of Double-Skin Facade

  • Choi Dong-Hee;Jo Jae-Hun;Seok Ho-Tae;Yeo Myoung-Souk;Kim Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.57-65
    • /
    • 2006
  • The blinds in the intermediate space are installed to block the direct solar radiation. As the blind divides the airflow of intermediate space into two parts, thermal performance of Double-Skin Facade(DSF) is affected by the blind position. Therefore the blind position should be planned with careful consideration in order to maximize the thermal performance of DSF. In this study, CFD was performed to analyze the effect of blind position in multistory-type DSF in variation of other DSF elements. The simulation results showed that the case with narrow depth of intermediate space and outlet on upper side of outer-facade, it is profitable to place blind as close as possible to the outer facade. In the other cases, the blind should maintain 0.15m distance from outer facade.

전도냉각형 펠티어 전류도입선의 최적화 (Optimization of Conduction-cooled Pottier Current Leads)

  • 정은수
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.764-771
    • /
    • 2005
  • A theoretical investigation for optimization of conduction-cooled Peltier current leads is undertaken. A Pottier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high Tc superconductor (HTS) lead in the order of decreasing thermoelectric tempera ture. Mathematical expression for the minimum heat flow per unit current crossing the TE metal interface and that flowing from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE-metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the 73 and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

Nucleate Pool Boiling of a Structured Enhanced Tube Used in a Flooded Refrigerant Evaporator

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Choi, Kuk-Kwang
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.23-28
    • /
    • 2000
  • In this study, pool boiling performance of a structured enhanced tube for a flooded refrigerant evaporator was experimentally investigated. Tests were performed for three different refrigerants(R-11, R-123, R-l34a). Compared with the heat transfer coefficients of the smooth tube, the heat transfer coefficients of the enhanced tube were 6.6 times larger for R-11, 6.0 times larger for R-123 and 3.5 times larger for R-l34a, which are comparable with the performance of foreign products. The heat transfer coefficients of R-l34a was higher than those of R-11 or R-123, both for the enhanced tube and for the smooth tube. At 4.4$^\circ$C saturation temperature, however, the heat transfer coefficients of R-l34a was approximately the same as those of R-11. The effect of the saturation pressure on the boiling performance was similar to that of the smooth tube-the heat transfer coefficient increased as the saturation pressure increased.

  • PDF