• Title/Summary/Keyword: Refrigeration Effect

Search Result 849, Processing Time 0.03 seconds

Effect of Aspect Ratio and Location of Outlets on Ventilation Performance in a Dry Room (Dry Room에서 종횡비와 배기구 위치가 환기성능에 미치는 영향)

  • 이관수;임광옥;최석호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.324-331
    • /
    • 2002
  • The characteristics of moisture ventilation in a dry room are studied numerically The behaviors of moisture ventilation are analyzed by varying the aspect ratio of the horizontal plane and for various positions of the outlets in the room. Three different ventilation efficiencies have been used to examine the effect of the longitudinal arrangement of outlets and transverse arrangement of outlets for each aspect ratio on ventilation inside the room. It is shown that the ventilation efficiency in the dry room can be improved by arranging the outlets transversely in the cases that the aspect ratio is less than three and longitudinally in the cases that it is greater than four.

Numerical analysis of collection performance for electro-cyclone (전기싸이클론의 집진 성능 해석)

  • 김완수;강윤호;이진원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.702-713
    • /
    • 1998
  • The characteristics of flow and particle collection for an electrocyclone with a central wire inside a high efficiency Stairmand cyclone was numerically analysed. Turbulent flow field was modeled by the Reynolds stress model and solved with an FVM code FLUENT. Particle motion and in-situ charging were simultaneously solved by a Lagrangian integration with time. The flow field obtained was in good agreement with experiments in the outer region. The characteristics of collection enhancement due to electric force were well manifested and well explained based on first principles. The effect of the in-situ charging process was very similar to the case of a simplified assumption of saturated charging, and the effect of the hopper was proved negligible.

  • PDF

The effect on the seasonal performance of an inverter compressor with higher and lower operating range (인버터 압축기의 저속과 고속운전범위가 계절성능에 미치는 영향)

  • 박윤철;하도용;민만기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.173-179
    • /
    • 1998
  • An experimental study was conducted on the effect of compressor capacity control range of heat pump on the seasonal energy efficiency ratio with variation of the maximum and minimum compressor input frequencies. To obtain seasonal energy efficiency ratio, steady state test at the maximum, minimum and intermediate compressor speed and cyclic test at the minimum compressor speed should be conducted. Maximum input frequency was varied to 95Hz, 105Hz, and 115Hz, and the minimum input frequency was varied to 35Hz, 45Hz, and 55Hz. The seasonal energy efficiency ratio increased as the input frequency of the compressor decreased. The maximum input frequency had only slight effects on the SEER.

  • PDF

Effect of Circumferential Velocity from Guide Vane on the Nozzle Flow of a Jet Fan (제트팬 노즐내부 유동에 대한 고정익 출구 원주속도의 영향)

  • 최충현;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.209-216
    • /
    • 2001
  • A numerical study is peformed to investigate the effect of circumferential velocity generated by the guide vane on the nozzle flow of a jet fan, s a way of increasing the penetration force of jet fan with nozzle of 175mm diameter. For the validation of numerical results. the velocity is measured by a 5-hole pitot tube and flow visualization is conducted by the tuft method. Under the inlet condition that the maximum circumferential velocity in the stator outlet of the present jet fan is 1.8m/s, the axial velocity in the nozzle outlet has the feature that the velocity at the axis is low and the velocity near the wall high. Therefore, to increase the throw length of the jet fan, the configuration of the fairing and nozzle needs to be developed and the precise revise of the stator angle is required, In addition, the bigger the circumferential velocity, the smaller the axial velocity at the axis and the bigger non-uniformity of the flow distribution.

  • PDF

Forced Convective Cooling Characteristics with Stacked Modules of Multi-PCBs' in Telecommunication Cabinet (다중 PCB 적층 모듈구조의 정보통신용 캐비넷 강제대류 냉각특성 연구)

  • Kim, W.T.;Kim, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.230-239
    • /
    • 1996
  • A multi-faceted experimental investigation has been carried out to study the cooling performance for stacked modules in arrays of heat generating rectangular modules deployed along PCB's in the enclosed cabinet. The main parameters which have an important effect on cooling characteristics are flow velocity, channel spacing, installation of fan unit, attachment of heat sink, and acoustic noise. The results of individual effect are very helpful for the electronic packaging designer. In order to improve the cooling performance, it is certain that the enlargement of channel space is obviously effective, while this id disadvantageous in high density electronic packaging. Each of the paameters is quantitatively examined as cooling performance and the correlation of Reynolds number to Nusselt number is compared with previous study.

  • PDF

Effects of Individual Components on the System Performance in a Desiccant Cooling System (제습냉방시스템에서 요소성능이 시스템성능에 미치는 영향)

  • Chang, Young-Soo;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.687-694
    • /
    • 2007
  • Cycle simulation is peformed for two types of the desiccant cooling system incorporating a regenerative evaporative cooler. The cooling capacity and COP are evaluated at various effectiveness values of the regenerative evaporative cooler, the desiccant rotor and the sensible heat exchanger. As either of the effectiveness of the regenerative evaporative cooler or the humidity effectiveness of the desiccant rotor increases, both the cooling capacity and COP increase, but the enthalpy leak ratio gives the opposite effect on the system performance. It is found that COP of cycle A mainly depends on the humidity effectiveness of the desiccant rotor, while for cycle B enthalpy leak ratio of desiccant rotor has the major impact on COP. The effect of the sensible heat exchanger on the cooling capacity is small about 1/10 compared with those of other components.

A theoretical model of the magneto-caloric effect in manganese perovskites

  • Phan, Manh-Huong;Pham, Van-Thai;Nhan, Huynh-Thanh;Yu, Seong-Cho
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.140-141
    • /
    • 2003
  • Recently, a large magneto-caloric effect (MCE) in perovskite materials has generated growing interests among scientists and manufacturers, because of its assessable and practical potential for the field of magnetic refrigeration. Nevertheless, further efforts of seeking a proper material that has a large magnetic-entropy change (ΔS$\sub$M/) or a large adiabatic temperature change (ΔT$\sub$ad/), i.e. a large MCE, in a vast variety of temperatures have been extensively devoted, but no theoretical treatments are satisfactorily made.

  • PDF

Evaporation of Water in an Aqueous Lithium Bromide Solution flowing over a Horizontal Tube

  • Kim, Dong-Kwan;Kim, Moo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.3
    • /
    • pp.57-62
    • /
    • 2001
  • Falling film heat transfer analyses with aqueous lithium bromide solution were performed to investigate the transfer characteristics of the copper tubes. Finned (knurled) tube and a smooth tube were selected as test specimens. Averaged generation fluxes of water and the heat flux were obtained. As the film flow rate of the solution increased, the generation fluxes of water decreased for both tubes due to the fact that the heat transfer resistance increased with the film thickness. The effect of the enlarged surface area at the knurled tube was supposed to be dominant at a small flow rate. The generation fluxes of water increased with the increasing degree of tube wall superheat. Nucleate boiling is supposed to occur at a wall superheat of 20K for a smooth tube, and at 10K for a knurled tube. The increased performance of the knurled tube was supposed to mainly come from the effect of the increased heating surface area.

  • PDF

Effect of Diffuser Shape on the Performance of Water-Chilled Heat Storage (축열조 성능에 미치는 디퓨저 형상의 영향)

  • 정재동;박주혁;조성환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.374-382
    • /
    • 2004
  • Diffuser design is crucial for water-chilled heat storage. Its impact on the system performance is more significant for the underground tank due to inherent limit on the aspect ratio and tank shape. The effect of diffuser shape on the performance of the water-chilled heat storage is numerically investigated. Three dimensional simulation has been conducted for fully incorporating the complex diffuser shape and the non-symmetric tank shape. Mixing at the inlet of the diffuser depends on the inlet Reynolds number, Froude number and the diffuser shape. Three types of the diffuser shape and the broad range of Reynolds number (Re=400, 800, 1200) and Froude number (Fr=0.5, 1.0, 2.0) are examined. The performance of the heat storage tank is evaluated by the thermocline thickness which is reverse to the degree of stratification. The radial regulated plate diffuser, which is the suggested diffuser shape in this study, shows the lowest thermocline thickness in the condition considered.

A Study on the Effect of the Heat Transfer Surface Position to the Condensation heat Transfer (전열면 자세가 응축 열전달에 미치는 영향에 관한 연구)

  • 조시기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.1
    • /
    • pp.25-29
    • /
    • 2001
  • A study has been conducted to investigate the effect of the heat transfer surface position in the range of dropwise condensation, filmwise condensation, and glacial condensation. For dropwise condensation promoter, the heat transfer surface was evaporated by gold. As a result, heat transfer rate is almost same where the position of heat transfer surface is between 45 and 135 degree. It is found that heat transfer rate was reduced as subcooled degree was increased. And it is also found that if the subcooled degree becomes lower, the position of heat transfer surface is more effective. Adversely, if the subcooled degree becomes higher, the effectiveness of surface position is getting relatively lower. Regardless of the position, the transition temperatures from dropwise condensation to filmwise condensation is in the vicinity of 80K.

  • PDF