• 제목/요약/키워드: Refrigeration Effect

검색결과 849건 처리시간 0.029초

마이크로핀관의 확관 전후 증발열전달 특성에 관한 실험적 연구 (An Experimental Study on Evaporative Heat Transfer Characteristics in Micro-Fin Tubes Before and After Expansion Process)

  • 전상희;황윤욱;윤석호;김민수
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.932-940
    • /
    • 2000
  • An experimental study on evaporative heat transfer characteristics in micro-fin tubes before and after expansion process has been performed with R-22. Single-grooved micro-fin tubes with outer diameter of 9.52 mm were used as test sections, and it was uniformly heated by applying direct current to the test tubes. Experiments were conducted at mass flow rates of 20 and 30 kg/hr. For each mass flow rate condition, evaporation temperature was set at 5 and $15^{\circ}C$and heat flux was changed from 6 to 11 kW/$m^2$ The evaporative heat transfer coefficient of micro-fin tubes after expansion is decreased because of the crush of fins and enlargement of inner diameter compared to that before expansion. Convective boiling effect decreased remarkably at higher quality range in the micro-fin tube after expansion, and the difference of the heat transfer coefficient in micro-fin tubes before and after expansion was greater for higher quality region. The evaporative heat transfer coefficient of the micro-fin tube after expansion was 19.9% smaller on the average than that before expansion.

  • PDF

왕복유동에서 재생기 특성 및 열전달에 관한 수치해석 (A Numerical Study on the Regenerator Preformance and Heat Transfer in Oscillating Flow)

  • 이건태;강병하;이재헌
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.88-98
    • /
    • 1996
  • The present study is concerned with the flow friction and heat transfer characteristics of the combination of various regenerator materials, using the different Darcy number and porosity, which is filled uniformly and partially in a tube under oscillating flow condition. The poros medium is adopted as Brinkmann-Forschheimer extended Darcy model. Numerical results are obtained or the flow and temperature fields and described the effect of the combination of various regenerator materials and Womersley number on the pressure drop, the heat transfer and the regenerator efficiency. The results obtained indicate that not only heat transfer between the tube wall and oscillating flow but also the pressure drop at both ends of the regenerator are increased, while the regenerator efficiency is decreased in the increase of womersley number. It is also found that the friction factor is increased as Reynolds number is increased. The comparison between the combination of the various regenerator materials and the homogeneous regenerator material shows that the regenerator efficiency can be enhanced with the proper combination of various regenerator materials even though the averaged porosity of the regenerator is same.

  • PDF

대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구 (Numerical study for performance analysis and design of a counterflow type cooling tower)

  • 이상윤;이정희;최영기;유홍선
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

핵비등에서 기포의 동특성에 대한 전기장의 효과 (Effects of an Electric Field on the Dynamic Characteristics of Bubbles in Nucleate Boiling)

  • 권영철;장근선;권정태;김무환
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.963-971
    • /
    • 2000
  • In order to investigate the effects of an electric field on EHD(Electro-hydrodynamic) nucleate boiling hat transfer characteristics in a nonuniform electric field under saturated pool boiling, the basic study has been performed experimentally. In the present study, the working fluid is R-113 and the plate-wire electrode system is used to generate a steep electric field gradient. Boiling parameters are investigated by using a high speed camera. The electric field distribution around a wire is obtained to understand the effect of an electric field on bubble departure/movement. The experimental results show EHD effects are much more considerable when the applied voltage increases. Bubbles depart away from the heated wire in radial direction. It is confirmed that the mechanisms of EHD nucleate boiling are closely connected with the dynamic behavior of bubbles. The boiling parameters are significantly changed by the electric field strength. With increasing applied voltages, the bubble size decreases and the nucleation site density, bubble velocity and bubble frequency increase.

  • PDF

지중 열교환기 보어홀에서의 유효 열전도도 및 열저항 산정 (Evaluation of Effective Thermal Conductivity and Thermal Resistance in Ground Heat Exchanger Boreholes)

  • 손병후;신현준;박성구
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.695-703
    • /
    • 2005
  • The objective of this study is to determine the effective thermal conductivity and thermal resistance values in test boreholes with three different fill materials. To evaluate these heat transfer properties, in-situ tests on four vertical boreholes were conducted by adding a monitored amount of heat to water over various test lengths. Two parameter estimation models, line-source and numerical one-dimensional models, for evaluation of thermal response test data were compared when applied on the same four data sets. Results show that the average thermal conductivity deviation between measured data and these two models is in the range of $3.03\%$ to $4.45\%$. The effect of increasing grout thermal conductivity from 1.34 to 1.82 $W/m^{\circ}C$ resulted in overall increases in effective formation thermal conductivity by $11.1\%$ to $51.9\%$ and reductions in borehole thermal resistance by $11.6\%$ to $26.1\%$.

LNG추출과정과 냉열이용의 열역학적 해석 (Thermodynamic Analysis of the Extraction Process and the Cold Energy Utilization of LNG)

  • 이근식;장영수;노승탁
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.120-131
    • /
    • 1995
  • Thermodynamic analysis of extraction process from the constant pressure LNG(Liquefied Natural Gas) vessel was performed in this study. LNG was assumed as a binary mixture of 90% methane and 10% ethane by mole fraction. The thermodynamic properties such as temperature, composition, specific volume and the amount of cold energy were predicted during extraction process. Pressure as a parameter ranges from 101.3kPa to 2000kPa. The result shows the peculiar phenomena for the LNG as a mixture. Both vapor and liquid extraction processes were investigated by a computer model. The property changes are negligible in the liquid extraction process. For the vapor extraction process, the temperature in the vessel increases rapidly and the extracted composition of methane decreases rapidly near the end of extracting process. Specific volume of vapor has the maximum and that of liquid has the minimum during the process. When pressure is increased, specific volume of vapor decreases and that of liquid increases. It was found that specific volume of vapor phase had a major effect on the heat absorption at constant pressure during vapor extraction process. If the pressure of the vessel increases, the total cold energy which can be utilized from LNG decreased.

  • PDF

온도차 자연환기 이론의 유량계수에 대한 연구 (A Study of Discharge Coefficient for Thermal Buoyancy Natural Ventilation)

  • 신동신;고현준;김세형;선지형;윤상민;이진영
    • 설비공학논문집
    • /
    • 제27권12호
    • /
    • pp.639-644
    • /
    • 2015
  • This study reviews the discharge coefficient for thermal buoyancy natural ventilation through experimentation. We measure the air velocity at the outlet, which is needed to derive the discharge coefficient and to compare with the theoretical value. When a temperature difference exists between the inside and outside of the building, the measured discharge coefficient differs from the theoretical value with a maximum difference of 12%. The size and position of the openings have little effect on the discharge coefficient. For practical application, the theoretical discharge coefficient can be used with little modification.

창호 풍지판 형상에 따른 기밀성의 실험적 연구 (An Experimental Study of Window Air Tightness according to Filling Piece Shapes)

  • 윤유라;박종준;김영일;정광섭
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.63-68
    • /
    • 2016
  • To study the effect of installation and the shapes of filling pieces used for windows on the infiltration rate, infiltration tests were performed with two types of sliding windows and two shapes for the filling pieces. Infiltration occurred most at the top and bottom parts of the center location where two windows overlap, indicating the necessity of a filling piece to be installed at these locations. Infiltration velocity is proportional to the square root of the pressure difference, complying well with the theoretical correlation. Infiltration is reduced about 50% by the filling piece installation. This study shows that filling pieces are essential and their shapes play significant roles in reducing the infiltration of windows.

공동주택 세대별 난방 성능 개선 연구 (A Study on Improved Heating Performance of an Apartment Housing Unit)

  • 서정아;신영기;김용기;이태원
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

바이오가스로부터 고순도 CH4 회수를 위한 PSA 공정의 실험적 연구 (Experimental Study on PSA Process for High Purity CH4 Recovery from Biogas)

  • 김영준;이종규;이종연;강용태
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.281-286
    • /
    • 2011
  • The objective of this study is to optimize the four-bed six-step pressure swing adsorption(PSA) process for high purity $CH_4$ recovery from the biogas. The effects of P/F(purge to feed) ratio and cycle time on the process performance were evaluated. The cyclic steady-states of PSA process were reached after 12 cycles. The purity and recovery rate of product gas, pressure and temperature changes were constant as the cycle repeated. It was shown that the P/F ratio gave significant effect on the product recovery rate by increasing the amount of purge gas in purge and regeneration step. The optimal P/F ratio was found to be 0.08. As the cycle time increased, the product purity decreased by increasing the feed gas flow rate. It was found that the optimal operating conditions were P/F ratio of 0.08 and total cycle time of 1,440 seconds with the purity of 97%.