• Title/Summary/Keyword: Refrigeration Effect

Search Result 849, Processing Time 0.02 seconds

Inhibitory Effects of Acetic Acid and Temperature on Growth of Campylobacter jejuni ATCC 33291

  • Kim, Wang-june;Shin, Soon-Young;Hwang, Han-Joon
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권6호
    • /
    • pp.934-939
    • /
    • 2001
  • The growth inhibition of Campylobacter jejuni ATCC 33291 in the presence of $1\%$ acetic acid at 4, 25, and $42^{\circ}C$, followed by $25^{\circ}C$ and $4^{\circ}C$, at pH 5.5 and pH 6.5, and by the addition of $1\%$ acetic acid aat 4, 25, and $42^{\circ}C$ were determined to be 22, 8.5, and 1.4 min, respectively, in an FBP-SBB medium. The D values of C. jejuni were increased by the addition of chicken and did not follow the linear relationship observed in the FBP-SBB media without chicken. When using distilled water instead of FBP-SBB in the model system, the death rate of C. jejuni was dramatically accelerated. The injured or low cell numbers that were impossible to enumerate using the plate count method, were detected by a polymerase chain reaction and enrichment culture procedure. These results suggested that acetic acid is reliable and effective as a disinfectant, however, it is necessary to take additional care at refrigeration temperatures due to the potential of injred cells during poultry processing.

  • PDF

환기시스템이 적용된 히트펌프의 난방시 급기효율 평가에 관한 연구 (A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner with Ventilation System for Heating Season)

  • 권용일;한화택;김경환;정백영;이감규
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.56-61
    • /
    • 2005
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.

${\cdot}$출구 위치 변화에 따른 압전 구동방식 마이크로 펌프의 성능특성에 관한 수치해석적 연구 (A Numerical Study on the Performance Characteristics of a Piezoelectric Micropump for Different Inlet and Outlet Positions)

  • 김동희;정진;김창녕
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.33-38
    • /
    • 2005
  • This study has been conducted to investigate flow characteristics of a micropump with piezoelectric materials. In this study, the change of flow rates has been investigated for different positions of the inlet and outlet and for different distances between them. The FSI(Fluid Structure Interaction) method has been employed for numerical analysis of the piezoelectric diffuser/nozzle based micropump. It has been found that time averaged flow rate is greater in the case that distance between the inlet and outlet is longer. For the cases where the positions of the inlet are different with the position of the fixed outlet at the center, the flow rate is increased as the inlet is located farther from the center. This study may supply fundamental understandings for the design and analysis of the prototypes of piezoelectric micropumps.

뉴튼 및 비뉴튼 유체의 헬리컬 유동에 관한 연구 (A Study on the Helical Flow of Newtonian and non-Newtonian fluid)

  • 김영주;김철수;황영규
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.8-15
    • /
    • 2005
  • This study concerns the characteristics of helical flow in a concentric and eccentric annulus with a diameter ratio of 0.52 and 0.9, whose outer cylinders are stationary and inner ones are rotating. Pressure losses and skin friction coefficients have been measured for fully developed flows of water and $0.2\%$ aqueous of sodium carboxymethyl cellulose(CMC), respectively, when the inner cylinder rotates at the speed of $0\~500$ rpm. The effect of rotation on the skin friction coefficient is significantly dependent on the flow regime. In all flow regimes, the skin friction coefficient is increased by the inner cylinder rotation. This study shows the change of skin friction coefficient and wall shear stress corresponding to the variation of rotating speed of the inner cylinder, radius ratio, eccentricity, and working fluids.

협착관내 층류유동에서 물의 결빙현상 (Ice-formation phenomena for laminar water flow in a stenotic tube)

  • 서정세;김무근;노승탁;임장순
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.11-21
    • /
    • 1998
  • A numerical study is made on the ice-formation for water flow inside a stenotic tube. The study takes into account the interaction existing between the laminar flow and the stenotic port in the circular tube. In the solution strategy, the present study is substantially distinguished from the existing works In that the complete set of governing equations in both the solid and liquid regions are resolved. In a channel flow between parallel plates, the agreement of predictions and available experimental data is very good. Numerical results are mainly obtained by varying the height and length of a stenotic shape and additionally for several temperatures of the wall and inlet of tube. The results show that the shape of stenotic port has the great effect on the thickness of the solidification layer in the tube. As the height of a stenosis grows and the length of a stenosis decreases, the ice layer thickness near the stenotic port is thinner due to backward flow caused by the sudden expansion of water tunnel. It is also found that the ice layer becomes more fat In accordance with Reynolds number and the temperature of the wall and inlet of tube decreased.

  • PDF

에어컨용 냉매 HFC-152a와 HFC-152a에 $CF_3$I를 혼합한 공비혼합냉매 특성에 관한 연구 (A Study on the Refrigerant Characteristics of the HFC-l52a, and Azeotrope Mixed with $CF_3$I in Air Conditioners)

  • 이종인;하옥남;홍경한;권일욱;박찬수
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.332-340
    • /
    • 2002
  • In these days, environmental concerns have been increased throughout the industry and community worldwide. To prevent the ozone depletion, ozone depletion potential of a refrigerant must be zero. Simultaneously, a refrigerant with low GWP (global warming potential) is very demanding to induce green house effect. Chlorine-free HFC-l34a is a refrigerant widely used for automotive air-conditioning system because its destruction potential is ecologically zero. Although HFC-l34a has no ozone depletion potential, its global warming potential is so high that it is not considered as a perfect alternative refrigerant that is acceptable for long-term use. In this paper, experimental measurement has been carried out to analyze the performance characteristics of automotive air-conditioning system using HFC-152a, which has low GWP and zero ODP. Also mixed refrigerant that is composed of HFC-152a and $CF_3$ was applied to investigate an alternative possibility for the automotive airconditioning system. As a result of this study, we could draw following conclusions; With respect to the variation of the rotational speed of compressor, outside air temperature and flow rate, the heat amount of evaporator and compressor and performance coefficient was varied.

수평 회전 히트파이프에서 내부 삽입 코일이 유동 형태 및 열전달 성능에 미치는 영향에 대한 실험 연구 (An experimental study on the effects of an inserted coil on flow patterns and heat transport performances for a horizontal rotating heat pipe)

  • 이진성;김철주;김선주;문석환
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.763-772
    • /
    • 1998
  • The effects of an inserted coil on flow patterns and heat transport performance for a horizontal rotating heat pipe have been studied experimentally. Especially, the present study is to see an internally inserted helical coil inside a RHP would lead to the same kind of results as internal fins. Visualization test conducted for an acryl tube, charged water with at a volumetric rate of 20%. When the flow kept pool regime at a low RPM(less than 1,000 RPM), the movement of coil forced the water to flow in axial direction. But this pumping effect of coil disappeared, when the pool regime changed to annular one which could be created by increasing RPM. The pumping effects for RHP with an inserted coil resulted enhancement both in condensation heat transfer coefficient and heat transport limitation, as obtained in case of using internal fins. But all these effects became negligible in the range of higher RPM(above 1,000∼1,200) with the transition of flow regime to annular flow.

  • PDF

내부핀이 부착된 원형관유동에서의 열전달특성에 관한 수치적연구 (A Numerical Study on the Heat Transfer Characteristics in an Internally Finned Circular Tube Flow)

  • 박희용;박경우;최문석
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.267-278
    • /
    • 1996
  • Steady, laminar, forced convection flow and heat transfer in the entrance region of an internally finned circular duct with a finite thermal conductivity has been analyzed numerically. The problem under investigation is a three-dimensional boundary layer problem, and is solved by employing a marching-type procedure which involves solution of a series of 2-dimensional elliptic problems in the cross-stream plane. Two types of inlet hydrodynamic conditions are considered : (a) uniform velocity flow and (b) fully developed flow. From the above inlet conditions, the effects of the fin height(h), fin number(N) and conductivity ratio($k_r$) on the flow and thermal characteristics are investigated. The numerical results show that the height and number of fins, and ratio of the solid to fluid thermal conductivity have pronounced effect on the solution. Considering pressure drop, optimized dimensionless fin height is 0.4.

  • PDF

원통형 수증기 개질기의 경계 온도 분포에 따른 개질 가스 조성 변화 (Effect of Boundary Temperature Distributions on the Outlet Gas Composition of the Cylindrical Steam Reformer)

  • 김석;한훈식;김서영;현재민
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.383-391
    • /
    • 2011
  • Numerical simulations have been conducted for the cylindrical steam reformer having various boundary temperature distributions. $CH_4$, $H_2O$, CO, $H_2$ and $CO_2$ are often generated or destroyed by the reactions, namely the Steam Reofrming(SR) reaction, the Water-Gas Shift (WGS) reaction and the Direct Steam Reforming(DSR) reaction. The SR and the DSR reactions are endothermic reactions, and the WGS reaction is an exothermic reaction. The rate of reactions can be slightly controlled by artificially given boundary temperature distributions. Therefore, the component ratio of the gases at the outlet are different for various boundary temperature distributions, namely the constant, cubic and linear distributions. Among these distributions, the linear temperature distribution is outstanding for efficient hydrogen production of the steam reformer.

진공고주파를 이용한 일체형 건조기개발에 관한 연구 (A Study on an Integrated Drying Machine with Microwave at Vacuum Conditions)

  • 김태형;고광수;박윤철
    • 설비공학논문집
    • /
    • 제26권9호
    • /
    • pp.441-446
    • /
    • 2014
  • In Jeju province, the Citrus is widely spread crop which is the most popular fruit on the island. When the quality of a Citrus is not in a good condition or when its size exceeds or is lower than the set criteria, it is discarded as a waste. In this study, a drying machine for waste Citrus has been developed with 2.6 GHz microwave energy supply to the Citrus at vacuum environment. The vacuum environment of the drying chamber was maintained to reduce the energy supply to the Citrus by lowering the evaporating temperature of the water. The experiment was conducted with variation of the vacuum pressure, interior temperature of the drying chamber, and operating time of the microwave. As a result, the effect of the temperature was shown to be higher than the other two control methods, and it showed with 0.305 g/W evaporation efficiency.