• Title/Summary/Keyword: Refrigerating capacity

Search Result 497, Processing Time 0.026 seconds

A study on the optimum control of refrigerator with on-off control system (On-off 제어계통을 갖는 냉동기의 최적제어에 관한 연구)

  • Ha, J.S.;Kim, W.N.;Kim, K.K.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.317-327
    • /
    • 1985
  • In the case of temperature control of air conditioning and refrigerating system, it is possible to operate the system continuously by controlling the cooling capacity of refrigerating machines. But on-off control system has been adopted for refrigerating system which has more large capacity than that required to remove the generated heat. In this on-off control system, it can be considered that there exists some optimum condition for the refrigerating capacity, operating cycle, running hour, and the temperature difference between thermostat setting value and real one. In this paper, an equation was derived to express the temperature variation of the refrigerated object (Nybrine) and later two evaluating functions were derived. One is for the temperature difference and another is for operating cycle and running hour. The weighted sum of these two functions is defined as the criterion function for the evaluation of the control performance of the system, and then the optimum running condition is investigated in the sense of minimizing the criterion function. Experiments showed that the heat balance equation derived for the temperature variation and the estimation of the time constant of the refrigerated system are appropriate. By conclusion, if a proper weighting factor D is selected, the optimum conditions exist for the refrigerating capacity, running hour, and operating cycle in the on-off temperature control of the refrigerating system.

  • PDF

Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (3rd. Report, Refrigerating Capacity in Evaporator and Heating Capacity in Absorber) (수직관(수직관)내를 흘러내리는 액막식흡수기(液膜式吸收器)의 흡수(吸收) 및 열전달(熱傳達) 특성(特性) (제(第)3보(報), 증발기(蒸發器)의 냉동능력(冷凍能力)과 흡수기(吸收器)의 난방능력(暖房能力)))

  • Ohm, K.C.;Kashiwagi, Takao;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.175-181
    • /
    • 1994
  • This paper deals with the correlation of absorption rate in absorber and evaporation rate in evaporator. The evaporator consists of a copper tube of 10mm dia, and 600mm long and chilled water flowing through the tube is fed by the chilled water circulator. The flowrate of LiBr-water solution in the absorber plays a significant role in determining the magnitude of the heat transfer rate from chilled water to refrigerant There exists a flowrate of solution which has a maximum value of heat transfer. It is interesting to note that the absorption rate of absorber increases with increasing the heat transfer rate of the evaporator. Also, absorption rate increases with evaportation rate, and the ratio(the former/the other) depends on the inlet temperature of LiBr-water solution in the absorber. The heating capacity in the absorber is higher than the refrigerating capacity in the evaporator.

  • PDF

Cycle Analysis of Diffusion Absorption Refrigerator (확산형 흡수식 냉장고의 사이클 해석)

  • 김선창;김영률;백종현;박승상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.817-824
    • /
    • 2002
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (typically hydrogen). This system has no moving parts and the associated noise and vibration. In this study, the operating characteristics of diffusion absorption refrigerator are investigated through cycle modeling and simulation. System parameters considered in this study are the charged concentration of ammonia aqueous solution, the concentration difference between absorber inlet and outlet and the system pressure determined by the amount of auxiliary gas charged. It was found that there exists a critical value of concentration difference that maximizes the refrigerating capacity. And the lower the system pressure, the higher the refrigerating capacity.

Control of Refrigerating Compressor Capacity Using Inverter (인버터를 이용한 냉동용 압축기의 용량 제어)

  • Yang, H.S.;Kim, H.S.;Kim, J.H.;Kim, S.B.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

Study on the Performance of the Cascade System Using Alternative Refrigerants (대체냉매를 사용한 이원냉동 시스템의 성능에 관한 연구)

  • 박종훈;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.564-571
    • /
    • 2001
  • The present study investigated the effect of key parameters on the performance of a cascade system using R-22 and R-23 refrigerants. Experimental data for the cascade system have been compared with simulation results using thermodynamic analysis. The cascade system tested at the evaporating temperature of $-80^{\circ}C $ and the condensing temperature of$40^{\circ}C $. The key experimental parameters were the evaporating temperature of the HTC(-35, -30, -25, -20, $-15^{\circ}C $) and mass flux of the HTC(200, 250, 300kg/$m^2$s). As the evaporating temperature and the mass flux of the HTC were increased respectively, the COP and the refrigerating efficiency were increased and then decreased while the volume flow rate per unit refrigeration capacity showed the opposite trend. The maximum COP and refrigerating efficiency were obtained at the evaporating temperature of the HTC of $-25^{\circ}C $ and the mass flux of 250 kg/$m^2$s.

  • PDF

Oplimum Design Conditions for a Basic Refrigeration Cycle (냉동사이클의 최적 설계조건)

  • Cho, Sung-Whan
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.356-361
    • /
    • 1986
  • An optimum design condition for a basic refrigeration cycle is defined as the condition which minimizes the total cost of heat exchanges (condenser and evaporator) and compressor for the refrigeration effect. Thermodynamic properties of ammonia (R717) are approximated by rational functions in order to obtain the optimum condition for a basic refrigeration cycle. Optimum condition depends on the heat capacity rates (mass flow rate times specific heat) of cooling water and brine used in condenser and evaporator. The difference between the cooling water temperature and condensation temperature at the optimum condition increases as the heat capacity rates and the coat of heat exchangers relative to the cost of compressor increase. Numerical examples of optimum conditions are obtained when the condensation temperature is $30^{\circ}C$ and the evaporator temperature is $-10^{\circ}C$.

  • PDF

Transient Heat Conduction Through the Ondol Floor and Beat toss to the Ground (온돌의 구들장과 땅바닥의 비정상 열전도 해석)

  • Bae, Soon-Hoon;Kim, Doo-Chun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.1
    • /
    • pp.6-17
    • /
    • 1975
  • For a periodic variation of the flue gas temperature the heat conduction through the Ondol floor was analysized. Also the heat loss to the ground was estimated. The floor thermal capacity, as a function of the floor thickness, has strong influence on the time lag of the temperature variation. It is an important design parameter for intermittent heating. Even for the steady periodic variation, there was significant heat loss to the ground below the Ondol floor.

  • PDF