모듈형 동시냉난방 열펌프의 장배관/고낙차에 따른 액선 과냉도 변화에 대한 연구 (Study on longitudinal variation of subcooling with high elevated liquid line in a modular heat pump system)

  • 신광호;김민성;백영진;나호상;박성룡
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1255-1260
    • /
    • 2008
  • This study is simulation of high elevated liquid line of a modular heat pump system to observe longitudinal subcooling variation. In a high elevated tube, subcooled refrigerant(R410A) through a condenser changes its states by heat transfer with surrounding air and by pressure drop from elevation. In this study, the liquid line was simulated through correlations of heat transfer and pressure drop for the variation from single-phase into two-phase flow. Pressure drop, heat transfer rate and vapor quality were calculated as key parameters. Two-phase turning heights and variations of the key parameters were confirmed from the simulation. As a result, high elevation of liquid line has great influence on upward flow, which requires additional equipment to compensate the variation.

  • PDF

항공기 외장형 정찰 장비용 냉각 시스템의 성능 특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Cooling System for Aircraft External Reconnaissance Stores)

  • 정대윤;이행복
    • 한국군사과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.74-80
    • /
    • 2013
  • In this paper, we have proposed a vapor cycle refrigeration system as a cooling system to provide cooling air to the aircraft external reconnaissance stores. In the proposed vapor cycle system, receiver which prevents refrigerant from subcooling was eliminated and thermal expansion valve was replaced with electronic expansion valve. The vapor cycle refrigeration system is aimed to provide cooling air to the reconnaissance stores which is added to the aircraft in the form of external store. The wide temperature range of ambient air from the flight conditions can decrease the cooling performance and can make the refrigeration system unstable in low ambient temperature. Performance characteristics of the vapor cycle refrigeration system has been experimented under air conditions which is derived from the flight envelope. From the experiments, the vapor cycle refrigeration system has been proved to provide enough cooling air to the reconnaissance equipment and to be stable under all the flight conditions.

동일한 유입온도조건에서 R134a와 R22 적용 응축기의 특성비교 (Comparison of Condenser Characteristics using R134a and R22 under the Same Inlet Temperature Condition)

  • 강신헝;변주석;김창덕
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.166-173
    • /
    • 2006
  • 본 연구에서는 상용 냉동 공조기기에서 사용하고 있는 휜-관 열교환기에서 R22와 이의 대체냉매로 채용하고 있는 R134a 압력강하와 열전달 특성에 대해 실험적으로 연구하였다. 실험은 입구온도 $60^{\circ}C$, 질량유량 $150,\;200,\;250\;kg/m^{2}s$의 범위에 대해 수행하였다. 이때 공기의 유입조건은 전구온도 $35^{\circ}C$, 상대습도 40%, 공기유속은 $0.68{\sim}1.6m/s$이다. 실험 결과 응축기 출구의 과냉도를 $5^{\circ}C$로 유지한 경우 Rl34a의 필요공기유속은 R22보다 5.9%작게 나타났으며, R134a의 압력강하는 R22보다 $18.1{\sim}20.4%$의 범위 내에서 크게 나타났다.

R744를 2차냉매로 사용하는 R404A용 냉동시스템의 성능 분석 (Performance analysis of R404A refrigeration system using R744 as secondary refrigerant)

  • 오후규;손창효
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.24-29
    • /
    • 2012
  • In this paper, an analysis on performance and exergy of R404A refrigeration system using R744 secondary refrigerant was performed numerically to optimize the design for the operating parameters. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporation and condensation temperature in the R404A refrigeration cycle and temperature difference of cascade heat exchanger. The main results are summarized as follows : The COP(coefficient of performance) of R404A refrigeration system increases with increasing evaporation temperature. The evaporation capacity of R744 as secondary refrigerant increases with the increase in evaporation pressure of R744 secondary refrigeration. And the enthalpy in the evaporator outlet of R744 increases with the increasing evaporation pressure of R744 secondary refrigeration. Therefore, it is important to analysis for the relationship between COP of R404A refrigeration system and refrigeration capacity of R744. As cascade evaporation temperature increase, the exergy loss of condenser and compressor using R404A is the largest among all components. Therefore, the exergy loss in the condenser and compressor using R404A must be decreased to enhance the COP of R404A refrigeration system with R744 secondary refrigerant.

R-502 대체 혼합냉매의 성능에 관한 실험적 연구 (Experimental study on the performance of R-502 alternative refrigerant mixtures)

  • 박동민;정동수;김종보;강득주
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.198-209
    • /
    • 1997
  • This paper is concerned about the performance of alternative refrigerants of R-502 which has been widely used in transport and low temperature refrigeration. A breadboard heat pump was constructed with counterflow heat exchangers and tested with R-502 and transitional alternatives of R-402A and R-402B and long-term alternatives of R-404A and R-507 to compare the performance of each refrigerant. Measurements were conducted at two different condensing temperatures of $43.3^{\circ}C$ and $52.0^{\circ}C$ and the evaporating temperature was varied over a range from $-25^{\circ}C$ to $-5^{\circ}C$. The evaporator superheat and condenser subcooling were maintained constant at about $5^{\circ}C$ for all tests. Test results showed that all alternative fluids tested in this research work can be used as 'drop-in' fluids to replace R-502 without any major problem. It is also found that in the long run HFC alternatives are to be used due to their favorable environmental characteristics and better performance.

  • PDF

신냉매 R1234yf의 외부 응축 열전달계수 (External Condensation Heat Transfer Coefficients of R1234yf)

  • 박기정;이철희;강동규;정동수
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.345-352
    • /
    • 2010
  • In this study, external condensation heat transfer coefficients(HTCs) of R134a and R1234yf are measured on a plain, low fin, and Turbo-C tubes at the saturated vapor temperature of $39^{\circ}C$ with the wall subcooling of $3{\sim}8^{\circ}C$. R1234yf is a new alternative refrigerant of low greenhouse warming potential for replacing R134a which is one of the greenhouse gases controlled by Kyoto protocol and is used extensively in mobile air-conditioners. Test results show that the external condensation HTCs of R1234yf are very similar to those of R134a for all three surfaces tested. For the application of condensation heat transfer correlations to the design of condensers charged with R1234yf, thorough property measurements are needed for R1234yf in the near future.

병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구 (Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition)

  • 강인석;최동규;김택영
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

Performance of Alternative Refrigerants in Low Temperature Chillers

  • Jung, Dong-Soo;Kim, Chong-Bo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.67-79
    • /
    • 1998
  • This paper is about the performance of alternative refrigerants for low temperature and transport refrigeration chillers. A breadboard refrigeration chiller was constructed with counterflow heat exchangers. R502, its transitional alternatives of R402A and R402B, and long-term alternatives of R404A and R507 were tested in an attempt to compare the performance of each refrigerant against R502. Measurements were conducted at two condensing temperatures of 43.3$^{\circ}C$ and 52.$0^{\circ}C$ and the evaporating temperature was varied over a range from -$25^{\circ}C$ to -5$^{\circ}C$. The evaporator superheat and condenser subcooling were maintained constant at about 5$^{\circ}C$ for all tests. Test results showed that all alternative fluids tested in this work can be used as 'drop-in fluids' to replace R502 without any major problem. It is also found that in the long run HFC alternatives are to be used due to their favorable environmental characteristics and better performance.

  • PDF

작동변수에 따른 R744용 해양온도차 발전 사이클의 엑서지 분석 (Exergy Analysis of R744 OTEC Power Cycle with Operation Parameters)

  • 윤정인;손창효;백승문;김현주;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권8호
    • /
    • pp.1036-1042
    • /
    • 2012
  • 본 논문은 R744용 해양온도차 발전 시스템의 운전변수에 대한 최적의 설계를 위해서 엑서지효율을 이론적으로 분석하였다. 본 연구에서 고려된 작동변수로는 과열도와 과냉각도, 증발온도와 응축온도, 터빈과 펌프 효율 등이다. 분석한 결과를 요약하면 다음과 같다. R744용 해양온도차 발전 사이클의 증발온도, 과열도, 터빈효율, 펌프효율이 증가할수록 엑서지 효율은 증가한다. 그러나 응축온도와 과냉각도는 증가할수록 엑서지 효율이 감소한다. 이 중에서 증발온도의 변화가 R744용 해양온도차 발전 사이클의 엑서지 효율에 가장 크게 영향을 미치고, 펌프효율이 가장 적게 영향을 미친다. 따라서 R744용 해양온도차 발전 사이클의 엑서지 효율을 증가시키기 위해서는 증발온도를 표층수 온도에 가장 근접하게 증가시키는 것이 유리하다.

응축기의 설계조건에서 R22, R407C, R410A의 압력강하 예측 및 실험 (Prediction and Experiment of Pressure Drop of R22, R407C and R410A on Design Conditions of Condenser)

  • 김창덕;박일환;이진호
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.42-53
    • /
    • 2004
  • An experimental study on the refrigerant-side pressure drop of slit fin-tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and its alternatives, R407C (R32/125/134a, 23/25/52 wt.%) and R410A (R32/125, 50/50 wt.%). Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and mass fluxes varying from 150 to 250 kg/$m^2$s for R22, R407C and R410A. The inlet air conditions are dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R410A and R407C were 17.8∼20.2% and 5∼6.8% lower than those of R22 respectively for the degree of subcooling of 5$^{\circ}C$. For the mass fluxes of 200∼250 kg/$m^2$s, the deviation between the experimental and predicted values for the pressure drop was less than $\pm$20% for R22, R407C and R410A.