터보 냉동기용 핀튜브에 관한 연구 ( I ) - 응축 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator( I ) -for Condensation Hear Transfer-)

  • 조동현;한규일;김시영
    • 수산해양교육연구
    • /
    • 제5권1호
    • /
    • pp.31-44
    • /
    • 1993
  • Through the early 1900's, the evolution of the surface condenser was closely tied to the development of steam engine and the turbine. As the chemical and petroleum industries evolved in the 1900's, the use of surface condensers in many different processes. Today, industry uses condensers in many shapes and sizes. The actual condensation process occurs on the outside surface of tubes. The nature of this surface geometry affects the condenser's heat transfer performance. The first condensers were built with plain tubes. As tube manufacturing techniques advanced, manufacturers started making tubes with integral fins. In the 1940's, fin densities were limited to about 600 to 700 fins per meter(fpm) because of manufacturing procedure. Today new manufacturing techniques allow production of tubes with fin densities ranging from 750 to 1600 fpm. The integral-fin tubes investigated in this paper are nominally 19 mm diameter. Eight tubes have been used with trapezodially shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. For comparison, tests are made using a plain tube having the same inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Betty and Katz's theoretical modelis is used to predict the R-11 condensation coefficient on horizontal integral-fin tubes having 748, 1024 and 1299 fpm. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken at steady state. The observed heat transfer enhancement for the finned and grooved tubes significantly exceeded that to be expected on grounds of increased area. For the eight fin tubes and one plain tube tested, the best performance has been obtained with a tube having a fin density of 1299 fpm, and a fin bight of 1.2mm and 30 grooves.

  • PDF

이중보온 열수송관에 대한 동결차수공법개발에 관한 연구 (The study of developing the freezing seal isolation method for the pre insulated heat transfer pipe)

  • 유병희;안창구;김우철;신익호
    • 에너지공학
    • /
    • 제26권3호
    • /
    • pp.105-112
    • /
    • 2017
  • 우리는 원자력발전시스템에서부터 상수도까지 많은 배관시스템을 사용하고 있다. 그리고 이들 배관시스템의 적절한 운용을 위하여 배관시스템의 유지 및 보수 등을 수행하고 있다. 특히 한국지역난방공사와 같은 대형플랜트 배관시스템의 고장은 기업의 생산성과 이익에 직결된 문제일 뿐만 아니라 국민의 안전과 편익과 같은 매우 중요한 문제를 유발할 수 있기 때문에 빠른 대응과 안전한 수리가 가장 중요한 문제로 대두되고 있다. 본 연구에서는 한국지역난방공사 사용 중인 이중보온 열수송관(300A)의 유지보수를 위하여 액화질소를 이용한 배관 동결차수공법을 개발하였다. 본 연구에서는 전산해석기법을 채용하여 대상 열수송관과 전용 재킷에 대한 내부 유동 및 열전달 해석을 수행하여 최적의 시스템을 선정하고, 상세 모델을 설계, 제작하였다. 실험실 규모 시험장치를 개발하여 차수공법에 대한 자체시험을 수행하고, 한국지역난방공사 세종지사 Test bed에서 현장적용 성능평가 시험을 수행하였다.

200kW ORC 터빈 개발 및 구성 (Design and Configuration of 200kW Organic Rankine Cycle Turbine)

  • 한상조;서종범
    • 대한기계학회논문집B
    • /
    • 제38권12호
    • /
    • pp.1057-1064
    • /
    • 2014
  • 최근 전세계적으로 재생에너지의 관심이 증가하고 있다. 그 중 많은 관심을 받고 있는 것이 상대적으로 낮은 온도의 폐열을 사용하는 유기랭킨사이클(ORC)이다. 유기랭킨사이클은 기존의 증기터빈사이클과 유사한 기술을 사용하지만 낮은 온도의 폐열을 사용하기 위해서 증기대신 냉매를 작동유체로 사용한다. 작동유체를 냉매로 사용함으로 인해 이상기체 가정을 사용할 수 없고, 이는 ORC 시스템에 이용되는 터빈의 설계를 좀 더 복잡하게 만든다. 또, 냉매의 큰 분자량과 복잡한 분자구조로 인하여 낮은 음속을 가지게 되고 이로 인해서 쉽게 초킹 조건에 접근하게 된다. 본 연구에서 R245fa를 작동유체로 하여 입구온도 $124^{\circ}$에 팽창비 9 의 조건에서 터빈의 효율을 증가시키기 위해 다단으로 설계된 아음속 ORC 터빈을 설계하는 과정과 터빈의 성능에 대하여 설명하고자 한다. 설계된 터빈은 200kW 급의 ORC 발전 시스템에 사용될 예정이다.

내경 4.57mm 관내 CO2의 증발 열전달 특성 (Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm)

  • 손창효
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.574-579
    • /
    • 2008
  • 수평관내 $CO_2$의 증발 열전달 계수를 실험적으로 조사하였다. 냉매 순환루프의 주요 구성품은 수액기, 변속냉매 펌프, 질량 유량계, 예열기, 증발기(시험부)로 구성된다. 시험부는 내경 4.57 mm의 수평 평활 스텐레스관이다. 실험은 질량유속 $400{\sim}900kg/m^2s$, 포화온도 $5{\sim}20^{\circ}C$, 열유속 $10{\sim}40kW/m^2$인 조건에서 수행하였다. 실험결과로부터 $CO_2$의 열전달은 대류비등보다는 핵비등에 더 많은 영향을 받는 것을 알 수 있었고, $CO_2$의 질량유속은 핵비등에 많은 영향을 미치지 않는 것으로 나타났다. 실험결과와 종래의 상관식을 비교해 본 결과, 기존의 상관식은 실험데이터를 과소예측하였지만, 정 등의 상관식은 좋은 일치를 보였다. 따라서, 수평관내 $CO_2$의 증발 열전달 계수를 예측할 수 있는 정확한 상관식의 개발이 필요하리라 판단된다.

소형 제빙기에 사용되는 R-404A 대체 R-448A, R-449A의 Drop-in Test에 대한 연구 (A Study on the Drop-in Tests of a Small Ice Maker Using R-404A Replacements R-448A and R-449A)

  • 이병무;김내현
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.21-27
    • /
    • 2019
  • 그간 소형 제빙기에는 R-404A가 사용되어 왔으나 지구 온난화와 관련하여 대체 냉매 적용이 시급한 실정이다. 본 연구에서는 제빙기에 적용되어 온 R-404A를 대체할 R-448A와 R-449A에 대하여 drop-in test를 수행하였다. 시험은 외기 온도와 증발판에 공급되는 물 온도를 변화시키며 수행되었다. 실험 결과 R-404A의 일 평균 제빙량은 R-448A보다는 5.3%, R-449A보다는 4.2% 크게 나타났다. 이는 R-404A의 기체 밀도가 커서 냉매 순환량이 증가하기 때문으로 판단된다. 한편 R-448A와 R-449A의 제빙량을 비교하면 외기온도나 믈 온도가 낮아 제빙량이 많으면 R-448A가, 외기 온도나 물 온도가 높으면 R-449A가 우수한 성능을 보인다. 일 평균 소비 전력량은 R-448A나 R-449A보다 R-404A에서 대략 10% 크게 나타났다. 한편 성적계수의 경우 R-448A와 R-449A는 거의 동일하고 R-404A의 값보다는 3.0% 크게 나타났다. 현재 R-448A, R-449A의 증발, 응축 열전달에 대한 데이터가 부족한 실정으로 향후 이 부분에 대한 기초 연구가 필요할 것으로 판단된다.

설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012)

  • 한화택;이대영;김사량;김현정;최종민;박준석;김수민
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

LNG 냉열을 활용한 저압 액화 공기 생산 공정 설계 및 경제성 평가 (Design and Economic Analysis of Low Pressure Liquid Air Production Process using LNG cold energy)

  • 문하늘;정근호;이인규
    • Korean Chemical Engineering Research
    • /
    • 제59권3호
    • /
    • pp.345-358
    • /
    • 2021
  • 본 연구에서는 액화천연가스(LNG; liquefied natural gas) 재기화 과정에서 버려지는 냉열을 회수하는 방법으로 액화 공기를 생산하는 공정을 개발하였다. 액화 공기는 LNG 수출국으로 운송하여 천연가스 액화를 위한 냉매를 부분적으로 대체하는 용도로 활용될 수 있다. 이를 위하여, 액화 공기는 LNG 운반선에 저장 가능한 압력을 만족하여야 한다. 따라서, 가장 널리 사용되는 멤브레인 탱크로 액화 공기를 운송하기 위해 약 1.3 bar에서 공기가 액체 상태로 존재할 수 있도록 설계하였다. 제안한 공정에서, 공기는 LNG와의 열교환 이후 추가적인 질소 냉매 사이클과의 열교환을 통해 과냉된다. LNG 운반선의 최대 용량만큼 액화 공기를 생산할 때 운송비용 측면에서 가장 경제적일 수 있으며, 천연가스 액화공정에서 활용할 수 있는 냉열이 많아지게 된다. 이를 비교하기 위하여, 동일한 1 kg/s의 LNG 공급 조건 하에서 기존 공정을 이용한 Base case와 제안공정 내 유입 공기 유량을 각각 0.50 kg/s, 0.75 kg/s, 1.00 kg/s으로 하는 Case1, Case2, Case3를 구성하고 열역학적 및 경제적 측면에서 분석하였다. 액화 공기 생산량이 많을수록 1kg의 생산량 당 더 많은 에너지가 요구되는 경향을 보였으며 Case3는 Base case 대비 0.18 kWh 높게 나타났다. 그 결과 Case3의 액화 공기 1 kg 당 생산 비용이 $0.0172 더 높게 나타났다. 그러나 액화 공기의 생산량이 증가함에 따라 1 kg 당 운송 비용이 $0.0395 감소하여 전체 비용 측면에서 Case3는 Base case에 비해 1 kg 당 $0.0223 적은 비용으로 액화 공기를 생산 및 운송할 수 있음을 확인하였다.