냉동기유가 모세관내의 냉매유량에 미치는 영향 (The Effects of Oil on Refrigerant Flow through Capillary Tubes)

  • 홍기수;황일남;민만기
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.791-801
    • /
    • 2000
  • An experimental study was conducted to analyze the effects of oil on refrigerant flow through adiabatic capillary tubes, and to develop a model for mass flow rates of refrigerant/oil mixture at various capillary tubes and flow conditions. Mass flow rates and the profiles of the pressures and temperatures along the capillary tubes was obtained with the oil concentration of R-22/SUNISO 4GS oil mixture at various test conditions. The flow trends as a function of geometry and flow conditions for pure refrigerant and refrigerant/oil mixture were similar in adiabatic capillary tubes. Mass flow rate of the refrigerant/oil mixture was less than that of pure refrigerant at the same test conditions.

  • PDF

다분지 응축기의 냉매유량 분배에 미치는 중력의 영향을 고려한 해석방법 (Analysis of the Gravity Effect on the Distribution of Refrigerant Flow in a Multi-circuit Condenser)

  • 이장호;김무환
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1167-1174
    • /
    • 2004
  • The method to consider gravity effect on the performance of a condenser is developed, and a simple condenser having 'nU' type two circuits is analyzed. Each circuit has the same length and inlet air-side operational conditions. The only difference between two circuits is the direction of refrigerant flow, which is exactly opposite each other between the upper 'n' type circuit and the lower 'U' type circuit. It is shown that the gravity makes the distribution of refrigerant flow uneven in the two circuits at lower refrigerant flow rates; heat transfer rate also becomes uneven. Moreover, much of the refrigerant exists as liquid state in the circuit having low refrigerant flow rate, which will make the cycle balance unstable in the refrigeration cycle system like a heat pump.

Reduction of the Refrigerant-Induced Noise from the Transition of Flow Pattern by Decreasing Tube Diameter

  • Takushima, Akira;Han, Hyung-Suk;Jung, Wei-Bong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.37-44
    • /
    • 2009
  • It is well known that a refrigerant-induced noise is caused by two-phase flow in the indoor unit of a heat pump air-conditioner. Especially when the flow pattern in a pipe is intermittent flow, the irregular noise occurs frequently. But it is very difficult to avoid this kind of the noise for the application of air-conditioner. Therefore, in this research, the flow patterns at two-phase flow state in a pipe of the indoor unit for the air-conditioner are researched using cycle simulator at typical cycle conditions. In order to find the relationship between refrigerant-induced noise and flow pattern, the noise patterns are investigated with respect to the estimated flow pattern from the various flow pattern maps. Base on the estimations of the flow patterns by those maps, the refrigerant-induced noise is evaluated as decreasing tube diameter, which can transit the flow pattern from slug to annular flow.

A/C 실내기 배관 형상에 따른 냉매 유동 소음 특성에 관한 연구 (The refrigerant flow noise from the A/C distribute pipe line shapes)

  • 배성원;허덕;오세기;정백영;오일권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.371-375
    • /
    • 2009
  • The distribution control of refrigerant flow is one of the basic technique to enhance system efficiency. However, if engineers forget to control the refrigerant flow speed in all operation range, refrigerant flow mal distribution becomes a noise source. The refrigerant flow noise should be checked and controlled at the lowest air flow mode which is the most silent mode and frequently used in night time.

  • PDF

멀티형 공조시스템의 증발기 과열도에 관한 실험적 연구 및 냉매유량 제어 (Experimental Study of the Superheat and Control of the Refrigerant Flow-Rate in the Evaporator of a Multi-type Air-Conditioning System)

  • 김태섭;홍금식;손현철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.221-221
    • /
    • 2000
  • The heat exchange part in a modern multi-type air-conditioning system employs multiple-pass heat exchangers. The heat-transfer performance of an each pass in such an exchanger depends strongly on the length of the two-phase region and the mass flow of the refrigerant. The total length and diameters of the pipes, the exit conditions, and the arrangement of each pass as well as the geometrical shape of the distributor at the branching sections are considered to be major factors affecting the heat-transfer performance. The refrigerant commonly used in these systems is HCFC-22. The two objectives of this paper are to investigate the characteristics of the refrigerant flow rate and the superheat in the evaporator of a multi-type air-conditioning system for a single or simultaneous operating conditions and to control the superheat and the refrigerant flow rate of the evaporator.

  • PDF

유동 양식 선도를 이용한 에어컨 실내기의 냉매 소음 저감 분석 (Experimental Study of the Refrigerant Induced Noise for Air Conditioner Using Flow Pattern Map)

  • 한형석;모진용;정의봉
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.957-963
    • /
    • 2008
  • The refrigerant-induced noise of the air conditioner is one of the irregular noises which occurs at the indoor unit. Because the air-conditioner makers are always trying to reduce the sound pressure level radiated from indoor unit, reducing the refrigerant-induced noise at low cooling mode is very important problem. But it is very difficult to estimate whether the refrigerant-induced noise occurs or not before it becomes problem. In this paper, a method to predict the refrigerant-induced noise is suggested using flow pattern map. It is estimated that the irregular noise from the refrigerant comes from the slug flow in a pipe.

  • PDF

냉장고 증발기 배관의 2상유동양식 예측 및 소음 평가 (Prediction of Two-phase Flow Patterns and Noise Evaluation for Evaporator Pipe in a Refrigerator)

  • 허소정;김민성;한형석;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제21권10호
    • /
    • pp.916-923
    • /
    • 2011
  • The refrigerant after the expansion valve interchanges the heat at the evaporator. At this moment, the state of gas and liquid becomes two-phase flow and causes irregular noise. In order to avoid the noise, the two-phase flow pattern should be predicted. In this paper, the procedure to predict the two-phase flow patterns such as churn flow and annular flow was suggested using the CFD software. The experiments using refrigerant-supplying equipment was carried out and the noise levels according to the flow pattern were measured. The flow patterns predicted by this procedure showed good agreement with those by experiments. The churn flow is noisier than annular flow pattern.

R12 냉매를 이용한 냉동압축기 임펠러 유동해석 (Numerical analysis on the impeller of chiller compressor using refrigerant R12)

  • 음학진;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.696-701
    • /
    • 2001
  • The performance and the internal flow of the impeller of the centrifugal chiller compressor with refrigerant R12 as working fluid were studied numerically, using CFD code, CFX-Tascflow, which is commercially available. In this numerical study, the thermodynamic and transport properties of the refrigerant gas were generated by the property program of NIST and linked with main program to extend the capability of the code to refrigerant gases. Numerical study was applied to several mass flow rates near the design mass flow rate at constant rotating speed. Overall performance and flow characteristics of the impeller at impeller exit were investigated. The results were physically reasonable and showed good agreement with experimental measurement at the design flow rate.

  • PDF

증발기 입구 배관의 구조 개선을 통한 냉장고 냉매 소음 저감 (Reduction of Refrigerant-induced Noise of the Refrigerator by Modification of the Evaporator Inlet Pipe)

  • 김민성;한형석;김태훈;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제19권10호
    • /
    • pp.1012-1020
    • /
    • 2009
  • This research is focused on the experimental study of the noise induced by two-phase refrigerant flow in the evaporator. The two-phase flow in the evaporator has various flow patterns. The effects of two-phase flow pattern's characteristics on the noise of the evaporator are investigated experimentally. The experimental data shows that the generated noise is mainly related to the layout of the pipe and the certain two-phase flow patterns such as the churn and slug flow. Based on these results, we removed the unnecessary vertical pipe and changed the pipe diameter of the evaporator - inlet into small one in order to avoid the intermittent flow condition. The noise level of newly-designed inlet-pipe of the evaporator was measured experimentally by refrigerant-supplying equipment and compared with that of conventional one.

분리형 에어컨의 실내기 냉매 소음 저감 분석 (Analyzing for Refrigerant Induced Noise for Split Type Air Conditioner Indoor Unit)

  • 시케오 아오야마;모진용;이재권;송용재;한형석
    • 한국소음진동공학회논문집
    • /
    • 제16권3호
    • /
    • pp.240-246
    • /
    • 2006
  • In the air-conditioner, refrigerant induced noise and vibration can be increased when the airflow rate is reduced in order to decrease the noise at the low mode. Through the test and analysis of this kind of noise, it can be verified that the main reasons of refrigerant induced noise are the velocity and flow Induced force of the refrigerant at the inlet of the evaporator, So, in order to reduce this velocity, quality at the evaporator inlet should be minimized. And, in order to reduce flow induced force of the refrigerant, sudden change of fluid flow must not be occurred. So, in this paper, we will review the characteristics of refrigerant cycle and find how the quality and flow induced force can be minimized.