• Title/Summary/Keyword: Refractive surgery

Search Result 41, Processing Time 0.038 seconds

Study of Masking Effect of Soft Contact Lenses on Cornea after Refractive Surgery (각막굴절교정 수술 안에 대한 소프트콘택트렌즈 착용 시 Masking 효과)

  • Moon, Ye-Rim;Park, Hyung-Min;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 2016
  • Purpose: This study investigated the masking effect of the hydrogel lens and silicone hydrogel lens on the cornea with refractive surgery and without surgery. Methods: 24 university students (means age: $23.48{\pm}2.89years$) without refractive surgery (12, control group) and with refractive surgery (LASIK: 8, LASEK: 4, experimental group) participated in the study. Mean refractive errors of right eyes were -2.73 D for control group and -0.24 D for experimental group. The differences in the refractive power and corneal topography map between pre- and post-wearing the -3.00 D lenses were compared, and 2 kinds of hydrogel contact lenses (0.89 Mpa, 0.49 Mpa) and 2 kinds of silicone hydrogel lenses (1.5 Mpa, 0.8 Mpa) were used for -3.00 D lenses. NVision-K5001 (Shin nippon, Japan) was used to measure the refractive power and Keratograph 5M (Oculus, Germany) to measure the corneal topography map change. Results: Variations in the refractive power increased to the plus direction in the experimental group after wearing soft contact lenses. The corneal topography map showed significant changes on the both groups after wearing soft contact lenses (p<0.05). However there were no significant differences in the refractive power and corneal topography map variations by lens materials. Conclusions: Wearing soft contact lenses showed corneal topography map changes. Especially wearing soft contact lenses on the flat cornea after corneal refractive surgery showed greater corneal power changes. Therefore, it should pay attention to refractive change in case of prescribing soft contact lenses to patients with corneal refractive surgery.

Objective Assessment of Visual Quality and Ocular Scattering Based on Double-pass Retinal Images in Refractive-surgery Patients and Emmetropes

  • Kim, Jeong-mee
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.597-604
    • /
    • 2019
  • This study was performed to evaluate objective visual quality and ocular scattering in myopic refractive-surgery patients, compared to emmetropes. Optical vision-quality parameters (modulation transfer function (MTF) cutoff and Strehl ratio) and objective scattering index (OSI) were measured using an optical quality analysis system (OQAS II) based on the double-pass technique. In all subjects, the higher the MTF cutoff and Strehl ratio, the lower the OSI and ocular higher-order aberrations (HOAs). The MTF cutoff and Strehl ratio for the laser-assisted subepithelial keratectomy (LASEK) group were lower than those for the emmetropia group, while the OSI, ocular HOAs, and spherical aberration (SA) for the LASEK group were higher than those for emmetropia group. Ocular scattering would be one of the important factors in regard to visual quality. Therefore, the quality of the retinal image in the LASEK patients has been shown to reduce the quality of vision more than in the emmetropes.

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.

Reliability of Autorefractometry after Corneal Refractive Surgery (레이저 굴절교정수술 후 자동굴절검사법의 신뢰성)

  • Lee, Ki-Seok
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.443-451
    • /
    • 2018
  • Purpose : To find out the reliability of autorefractometer after laser refractive surgery Methods : We measured and compared spherical and cylinder powers of those undergone LASEK surgery with 1.0 of naked vision after at least 3 months of the surgery with an autorefractometer(CANON Full Auto Ref-Keratometer RK-F1, Japan) and a retinoscope(Streak Retinoscope 18200, WelchAllyn, USA), and also applied spherical equivalent powers. The refractive status before surgery was divided into high, medium, and low myopia according to the results measured using an autorefractometer, and then analyzed again the reliability of the autorefractometer after surgery according to the preoperative refractive status. The agreement of two methods was identified using Bland-Altman(Bland-Altman limits of agreement(LoA)). Results : After the surgery, when comparing spherical, cylinder and equivalent powers in the whole data measured by autorefractometry and retinoscopy significant differences were found(p<0.01). According to the degree of refractive errors, all sort of refractive errors was shown significantly different(p<0.01) except for cylinder power of the medium myopia. In general, the refractive errors especially spherical and spherical equivalent powers by autorefractometry were shown a myopic trend from -0.38 D to -0.53 D. On the other hand, it was shown a hyperopic trend of approximately +0.30 D using retinoscopy. In comparison of two objective refractions, it was shown a myopic trend as $-0.51{\pm}0.45D$(LoA +0.36 D ~ -1.39 D) and compatible. Conclusion : Even though it would be positive in terms of compatibility of the methods, it is necessary that the glasses should be prescribed by subjective refraction since autorefractometry is shown myopic in those undergone the surgery and suffering from myopic regression.

The Relationship between Refractive Myopia and Corneal Astigmatism in Korea Women University Students (한국 여자대학생의 굴절성 근시와 각막난시 관계)

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose. To analysis the prevalence of the myopia and corneal astigmatism in Korea women university students. Methods. From August 2011 to December 2012, one hundreds subjects were performed in refraction test using the Auto-Keratometry. Results. The mean age of the 100 subjects (200 eyes) was $21.23{\pm}2.34$. The mean spherical refractive power was -$1.78{\pm}1.65$(OD) and -$1.83{\pm}1.67$(OS) Diopter. The mean astigmatism power was $1.22{\pm}0.96$ (OD) and $1.27{\pm}0.91$ (OS). The mean corneal astigmatism was $1.44{\pm}0.81$(OD) and $1.55{\pm}0.93$(OS). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5%. There was a statistical significance between right eye and left eye in the spherical equivalent power(p=0.002). Also there was a statistical significance between spherical power and refractive astigmatism in OD(p=0.006) and OS(0.003) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.0003). However, there was not a statistical significance between spherical power and corneal astigmatism in OD(p=0.08) and OS(0.1) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.48). Conclusions. In this study, these results suggested that the analysis of the refractive myopia and corneal astigmatism can provide the visual correct and useful diagnosis information for the eyewear dispensing, contact lens fitting and corneal refraction surgery.

  • PDF

Trends and Refractive Status of Cataract Surgery - An Optometry Clinic-Based Survey in Chungbuk (백내장 수술 경향과 굴절상태 - 충북 지역의 안경원 중심으로 조사)

  • Kim, Hyeong-Su;Son, Jeong-Sik;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the distribution of age and gender, types of intraocular lens (IOL), and refractive errors in subjects who had cataract surgery. Methods: 2,217 subjects who had cataract surgery were surveyed at an optometry clinic in Chungbuk from 2010 to 2012. Information about IOL was obtained from case history, reflective and retroillumination images IOL by auto refracto-keratometer. Refractive errors were determined by objective and subjective refraction. Results: The mean age of the subjects was $71.74{\pm}10.62$ years. The number of cataract surgeries increased from 524 persons in 2010 to 888 persons in 2012. Of the subjects surveyed, 52 persons (2.3%) were under the 40 years of age, 144 persons (6.5%) were in 50s, 404 persons (18.2%) were in 60s, 1,132 persons (51.1%) were in 70s, 485 persons (21.9%) were in above 80s. Cataract surgery was significantly prevalent in more female (1,338 persons, 60.4%) than in male (879 persons, 39.6%). Types of IOL were 2,141 persons (96.6%) for monofocal lens, special IOLs such as multifocal, accommodative and toric lens were 76 persons (3.4%). The distribution of refractive errors after cataract operation were 1,588 eyes (38.5%) for simple myopic astigmatism, 327 eyes (7.9%) for simple hyperopic astigmatism, 601 eyes (14.6%) for mixed astigmatism, 1,240 eyes (30.0%) for myopia, 136 eyes (3.3%) for hyperopia, and 234 eyes (5.7%) for emmetropia. The uncorrected and best corrected visual acuity of the subjects were $0.55{\pm}0.25$ and $0.80{\pm}0.23$, respectively. Conclusions: The prevalence of cataract surgery increased with age until 70s years of age, it was more prevalent in men than women over 60s, and frequency of special types of IOL were low. Most cataract surgeries left residual refractive errors. Therefore even after cataract surgery it may need spectacles for better vision at either distance or near.

Comparison of Central and Peripheral Refraction in Myopic Eyes after Corneal Refractive Surgery and Emmetropes (굴절교정수술을 받은 근시안과 정시안에서 중심부 및 주변부의 굴절력 비교)

  • Kim, Jeong-Mee;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.157-165
    • /
    • 2015
  • Purpose: To evaluate changes in central and peripheral refraction along the horizontal visual fields in myopic corneal refractive surgery group compared with emmetropes. Methods: One hundred twenty eyes of 60 subjects ($23.56{\pm}2.54$ years, range: 20 to 29) who underwent myopic refractive surgery and 40 eyes of 20 emmetropes ($22.50{\pm}1.74$ years, range: 20 to 25) were enrolled. The central and peripheral refractions were measured along the horizontal meridianat $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$ in the nasal and temporal areas using an open-field autorefractor. For analysis of post-op group, the group was classified by pre-op spherical equivalents of < -6.00 D and ${\geq}-6.00D$ as two post-op groups. Results: Pre-op spherical equivalent was $-4.56{\pm}0.92D$ (rang: -2.50 to -5.58 D) in post-op group 1, and $-7.09{\pm}0.96D$ (rang: -6.00 to -9.00 D) in post-op group 2. Spherical equivalent (M) in the emmetropes ranged from $-0.20{\pm}0.22D$ at center to $-0.64{\pm}0.83D$ at $25^{\circ}$ in the temporal visual field and to $-0.20{\pm}0.67D$ at $25^{\circ}$ in the nasal visual field; M in post-op group 1 ranged from $-0.16{\pm}0.29D$ at center to $-5.29{\pm}1.82D$ at $25^{\circ}$ in the temporal visual field and to $-4.48{\pm}1.88D$ at $25^{\circ}$ in the nasal visual field; M in post-op group 2 ranged from $-0.20{\pm}0.32D$ at center to $-7.98{\pm}2.08D$ at $25^{\circ}$ in the temporal visual field and to $-7.90{\pm}2.26D$ at $25^{\circ}$ in the nasal visual field. Among the three groups, there was no significant difference in M at central visual field (p=0.600) and at $5^{\circ}$ in the temporal visual field (p=0.647), whereas, there was significant difference in M at paracentral and peripheral visual field (p=0.000). Conclusions: Emmetropes had relatively constant refractive errors throughout the central and peripheral visual field and showed myopic peripheral defocus along the horizontal visual field. On the other hand, in myopic corneal refractive surgery group, there were significant differences in refractive errors between the central and peripheral visual field compared with differences in the central and peripheral refraction patterns of emmetropes.

Corneal Asphericity and Optical Performance after Myopic Laser Refractive Surgery (굴절교정수술을 받은 근시안의 각막 비구면도와 광학적 특성 평가)

  • Kim, Jeong-Mee;Lee, A-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • Purpose: To compare corneal asphericity, visual acuity (VA), and ocular and corneal higher-order aberrations (HOAs) between myopic refractive surgery and emmetropia groups. Methods: Twenty three subjects ($23.0{\pm}2.5$ years) who underwent myopic refractive surgery and twenty emmetropia ($21.0{\pm}206$ years) were enrolled. The subjects'criteria were best unaided monocular VA of 20/20 or better in both two groups. High and low contrast log MAR visual acuities were measured under photopic and mesopic conditions. Corneal and ocular HOAs were measured using Wavefront Analyzer (KR-1W, Topcon) for 4 mm and 6 mm pupils. Corneal asphericity was taken by topography in KR-1W. Results: There was no significant difference in VA between two groups under either photopic or mesopic conditions. In ocular aberrations, there were significant differences in total HOAs, fourthorder and spherical aberration (SA) for a 6 mm between two groups (p=0.045, p<0.001, and p<0.001, respectively). In corneal aberrations, there was a significant difference in SA for 4 mm (p=0.001) and 6 mm (p<0.001) pupils between two groups and there were statistically significant differences in total HOAs (p<0.001) and fourth-order aberrations (p<0.001) between two groups for a 6 mm pupil. There was a significant correlation in emmetropia between Q-value and SA in ocular aberrations for 4 mm and 6 mm pupils (r=0.442, p=0.004, and r=0.519, p<0.001) and in corneal aberrations for 4 mm and 6 mm pupils (r=0.358, p=0.023, and r=0.646, p<0.001). No significant correlations were found between Q-value and SA in refractive surgery group. Conclusions: VA in myopic refractive surgery is better than or similar to emmetropia. Nevertheless, the more increasing pupil size is, the more increasing aberrations are. Thus, it could have an influence on the quality of vision at night.

Determination Factors Affecting the High Order Aberrations in Preoperative and Postoperative LASEK (라섹 수술 전과 후의 고위수차에 영향을 미치는 결정변수)

  • Kim, Tae-Heung;Lee, Hyun;Rhee, Kang-Oh;Lee, Tae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5621-5627
    • /
    • 2014
  • To specify the standard of LASEK surgery, this study examined the determination factors affecting the high order aberrations (HOAs) in preoperative and postoperative LASEK. 51 adult patients (102 eyes) were evaluated at the baseline and 2 months after LASEK surgery from Nov 2011 to Jul 2012. The postoperative HOAs ($0.538{\mu}m$) were higher than the preoperative ($0.341{\mu}m$). In linear regression analysis, the refractive components that affected the postoperative HOAs were $J_0$ of corneal astigmatism (CA, 0.400), $J_0$ of refractive astigmatism (RA, 0.389), corneal astigmatism (CA, 0.282), spherical equivalent (SE, 0.239), refractive astigmatism (RA, 0.213), and pupil size (PS, 0.194) with a high R. In multiple regression, $J_0$ of CA, PS and SE were significant factors with the postoperative HOAs. In conclusion, both HOAs and $J_0$ of CA should be considered when determining the suitable factors for LASEK surgery.

Scotopic Pupil Size in Myopes (근시안에서 암순응상태의 동공크기)

  • Jeong, Woo-Jae;Jeon, In-Chul;Kang, Ji-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.197-202
    • /
    • 2013
  • Purpose: This research was performed to measure and analyze scotopic pupil size in myopes and to figure out the factors that influence it. Methods: The pupil size of 191 healthy myopic subjects were measured with the pupillometer (Colvard pupillometer, OASIS medical, USA) in scotopic and analyzed with the age, corneal size, spherical equivalent refractive error, corneal curvature. In addition, it was compared with the measurements of intra-examiner and inter-examiner to verify reproducibility of pupillometer. Results: The mean (${\pm}$SD) scotopic pupil size was $6.64{\pm}0.68$ mm (range, 5.00~8.00 mm), the lower age and the larger corneal size, The bigger the pupil size. The lower spherical equivalent refractive error and steepper corneal curvature tends to be smaller. The reproducibility of intra-examiner and inter-examiner in pupillometer showed the reliability highly (Guttman splithalf point > 0.91). Conclusions: The pupil size associated with age, corneal size, spherical equivalent refractive error and corneal curvature in scotopic condition. It can refer to prevent inconvenience that may occur RGP contact lenses, cataract surgery and refractive surgery.