• Title/Summary/Keyword: Reflected pressure

Search Result 248, Processing Time 0.025 seconds

A Study on the Microwave Reflection of Plasma in a Magnetic Field (방전프라즈마내 자계에 의한 마이크로파 반사특성)

  • 김봉열;김정기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.6 no.1
    • /
    • pp.12-18
    • /
    • 1969
  • The characteristics of microwave reflection in the media of cold gaseous plasma is analysed to various external magnetic flux density. The DC discharge plasma is generated in the rectangular waveguide which contains two electrodes and helium gas at the pressure of 10-2mm Hg. The reflected and transmitted power of microwave is measured when the electric field is parallel to, and perpendicular to the external magnetic field. It shows that the reflected power is increased as the magnetic flux density is increased in the parallel case, but the maximum value of the reflected power is occured at the cyclotron resonance (3120 Gauss) in the perpendicular case.

  • PDF

A Study on a Quantitative Measurement of Contact Pressure Between two Rough Flat SurFaces by Means of Ultrasonic Waves. (초음파를 이용한 이체 평면접촉부의 정량적인 접촉압력 측정에 관한 연구)

  • 김경모;정인성
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.8-26
    • /
    • 1990
  • It is important to have exact information about the contact pressure distribution in the design of connected parts of machines and structures. In previous works, stress analyses on a two body contact problem have been carried out in large numbers. Besides, the measurement of contact stress is important to confirm the adequateness of the theoretical analysis, to verify appropriateness of Hertzian contact theory and to know the practical pressure distribution, but an excellent measuring method con't be found at present. Therefore, a quantitative measurement of contact pressure by means of ultrasonic waves using a normal probe and an angle has been proposed to measure the contact pressure distribution between two rough flat surfaces. At first, in a new proposed calibration method, the relation between mean contact pressure and sound pressure of reflected waves is obtained by using calibration blocks with various surface roughnesses made of the same material as the rectangular section beams And then, this experimental results are compared with the analytical ones, and the utility of this method is discussed.

  • PDF

EVALUATION MODEL FOR RESTRAINT EFFECT OF PRESSURE INDUCED BENDING ON THE PLASTIC CRACK OPENING OF A CIRCUMFERENTIAL THROUGH-WALL CRACK

  • Kim, Jin-Weon
    • Nuclear Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.75-84
    • /
    • 2007
  • This paper presents a closed-form model for evaluating the restraint effect of pressure induced bending on the opening of a circumferential through-wall crack, which is considered plastic deformation behavior. Three-dimensional finite element analyses with different crack lengths, restraint conditions, pipe geometries, magnitudes of internal pressure, and tensile properties were used to investigate the influence of each parameter on the pressure-induced bending restraint on the crack opening displacement. From these investigations, an analytical model based on elastic-perfectly plastic material was developed in terms of the crack length, symmetric restraint length, mean radius to thickness ratio, axial stress corresponding to the internal pressure, and normalized crack opening displacement evaluated from a linear-elastic crack opening condition. Finite element analyses results demonstrate that the proposed analytical model reliably estimated the restraint effect of pressure-induced bending on the plastic crack opening of a circumferential through-wall crack and properly reflected the dependence on each parameter within the range over which the analytical expression was derived.

Development of microscopic surface profile estimation algorithm through reflected laser beam analysis (레이저 반사광 분석을 통한 미세 표면 프로파일 추정 알고리즘의 개발)

  • Seo Young-Ho;Ahn Jung-Hwan;Kim Hwa-Young;Kim Sun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.64-71
    • /
    • 2005
  • In order to measure surface roughness profile, stylus type equipments are commonly used, but the stylus keeps contact with surface and damages specimens by its tip pressure. Therefore, optics based measurement systems are developed, and light phase interferometer, which is based on light interference phenomenon, is the most noticeable research. However, light interference based measurements require translation mechanisms of nano-meter order in order to generate phase differences or multiple focusing, thus the systems cannot satisfy the industrial need of on-the-machine and in-process measurement to achieve factory automation and productive enhancement. In this research, we focused light reflectance phenomenon rather than the light interference, because reflectance based method do not need translation mechanisms. However, the method cannot direct]y measure surface roughness profile, because reflected light consists of several components and thus it cannot supply surface height information with its original form. In order to overcome the demerit, we newly proposed an image processing based algorithm, which can separate reflected light components and conduct parameterization and reconstruction process with respect to surface height information, and then confirmed the reliability of proposed algorithm by experiment.

Experimental Analysis for Variation of Pressure Difference on Flooding in PEM Fuel Cell at Cathode Channel Outlet (Cathode 출구 압력 변화에 따른 PEM Fuel Cell 내에서의 플러딩에 관한 실험적 연구)

  • Ahn, Deuk-Keun;Han, Seong-Ho;Kim, Kyoung-Rock;Choi, Young-Don
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.390-396
    • /
    • 2009
  • The flooding, especially in channel, is one of the critical issue to put proton exchange membrane fuel cell (PEMFC) to practical use. In this paper, channel flooding was investigated the pressure difference at cathode channel outlet. A ratio of pressure difference changes to 25, 50% as its variation rate. The pressure variable rate is reflected in dimensionless number FN. As a result, modified dimensionless number $FN^*$ correctly predicted the channel flooding. This study analyzes that a variety of pressure difference is how to affect flooding at the cathode of the PEMFC.

Unsteady Flow Analysis of Liquid Hydrazine Propellant for the Design Parameter Derivation of Satellite Propulsion System (인공위성 추진기관 설계변수 도출을 위한 Hydrazine 액체 추진제의 비정상 유동해석)

  • Choi, Jin-Chul;Kim, Jeong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.497-501
    • /
    • 2000
  • One of the way to derive design parameters of the fuel feeding system in satellite is to analyze unsteady flow of liquid propellant (hydrazine) in the propulsion system. During steady thruster firing the flow rate is constant: if a thruster valve is abruptly shut down among a sets of thrusters, pressure spikes much higher than the initial tank pressure occur. This renders the fuel flow unsteady, and the fluid pressure and flow rate to oscillate. If the pressure spikes are high enough, there are possibilities that propellant explosively decomposes, thruster valves are damaged, and adiabatic detonation of the hydrazine propellant is potentially incurred. Reflected shockwaves could also affect the calibration and operation of the pressure transducers. These necessitate the analysis of unsteady flow in the propulsion system design, and the calculation results obtained through some governing parameter variation are presented in this work.

  • PDF

A Study of Human Gait Discrimination Using Multi-pressure Sensor (다중압력센서를 이용한 보행패턴 추정에 관한 연구)

  • Choi, Dae-Yeong;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.673-677
    • /
    • 2016
  • In this study, In order to measure foot pressure, it makes analyzing device using multi-pressure sensor. This device was limited frequency band to 5Hz by using low-pass filter and MCU was detected signal every milliseconds. After wearing the device, the result was confirmed by blue-tooth to measure wirelessly. Also, we propose an algorithm to obtain the walking pattern using a time table in each of the detected peak from the pressure sensor. Using the algorithm, right walking pattern and abnormal pattern was detected. The results can be reflected more individual walking patterns than when using a conventional methods and also, developed device was no restriction on the human activity.

Development of the Cardiovascular Simulator for Pulse Diagnosis Study (맥진연구를 위한 심혈관계 시뮬레이터의 개발)

  • Lee, Ju-Yeon;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • Objectives The aim of this study is to develop a cardiovascular simulator that can reproduce blood pressure pulse and blood flow similar to those of the human body. Methods In order to design a system similar to the human cardiovascular system, the required performances were determined by investigating the hemodynamic characteristics of the heart and the arterial system. Main organ to be imitated is heart in simulator. The rest of the system was minimally designed. Also, a blood pressure and blood flow measurement system was developed for measuring the results. Results The developed system showed blood pressure pulse at similar range of the human aorta. The result waveform include primary wave caused by ventricular systole except reflected wave. Conclusions The blood pressure and blow flow patterns were replicated by the simulator. These patterns were similar to those of the human body. The system will play an important role in studying pulse diagnostics.

Quantitative Evaluation of Driver's Postural Change and Lumbar Support Using Dynamic Body Pressure Distribution (동적 체압 분포를 이용한 운전 자세 변화와 요추지지대의 정량적 평가)

  • Na, Seok-Hui;Im, Seong-Hyeon;Jeong, Min-Geun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.57-73
    • /
    • 2003
  • Although body pressure distribution is sensitive to movements and is relatively simple to measure even in small space, there are few researches involving applications to driver's posture and its change. The main objective in this study is the application of body pressure distribution measurements for the prediction of the driver's posture and its change. This requires quantitative analyses of the dynamic body pressure distribution, which is the change of body pressure distribution with time. The experiment involved 16 male subjects who drove for 45 minutes in a seating buck. Measurement time, stature group, and lumbar support prominence were selected as independent variables, with subjective ratings of driver's discomfort, body posture data of hip, torso. knee angle, and body pressure data variables as dependent variables. The body pressure change variables and subjective ratings were found to increase as the measurement time increased and body pressure ratio variables reflected the torso angle. From the results and analysis of the body posture data and subjective rating results, it was predicted that the seats and the design of the lumbar supports used in the experiment was not fit for tall subjects, which could also be confirmed through the body pressure distribution data.

Linking Clinical Events in Elderly to In-home Monitoring Sensor Data: A Brief Review and a Pilot Study on Predicting Pulse Pressure

  • Popescu, Mihail;Florea, Elena
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.180-199
    • /
    • 2008
  • Technology has had a tremendous impact on our daily lives. Recently, technology and its impact on aging has become an expanding field of inquiry. A major reason for this interest is that the use of technology can help older people who experience deteriorating health to live independently. In this paper we give a brief review of the in-home monitoring technologies for the elderly. In the pilot study, we analyze the possibility of employing the data generated by a continuous, unobtrusive nursing home monitoring system for predicting elevated(abnormal)pulse pressure(PP) in elderly(PP=systolic blood pressure-diastolic blood pressure). Our sensor data capture external information(behavioral) about the resident that is subsequently reflected in the predicted PP. By continuously predicting the possibility of elevated pulse pressure we may alert the nursing staff when some predefined threshold is exceeded. This approach may provide additional blood pressure monitoring for the elderly persons susceptible to blood pressure variations during the time between two nursing visits. We conducted a retrospective pilot study on two residents of the TigerPlace aging in place facility with age over 70, that had blood pressure measured between 100 and 300 times during a period of two years. The pilot study suggested that abnormal pulse pressure can be reasonably well estimated (an area under ROC curve of about 0.75) using apartment bed and motion sensors.