• Title/Summary/Keyword: Reference sensor

Search Result 906, Processing Time 0.021 seconds

A wireless sensor network approach to enable location awareness in ubiquitous healthcare applications

  • Singh, Vinay Kumar;Lim, Hyo-Taek;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.277-285
    • /
    • 2007
  • In this paper, we outline the research issues that we are pursuing towards building of location aware environments for mainly ubiquitous healthcare applications. Such location aware application can provide what is happening in this space. To locate an object, such as patient or elderly person, the active ceiling-mounted reference beacons were placed throughout the building. Reference beacons periodically publish location information on RF and ultrasonic signals to allow application running on mobile or static nodes to study and determine their physical location. Once object-carried passive listener receives the information, it subsequently determines it's location from reference beacons. The cost of the system was reduced while the accuracy in our experiments was fairly good and fine grained between 7 and 12 cm for location awareness in indoor environments by using only the sensor nodes and wireless sensor network technology. Passive architecture used here provides the security of the user privacy while at the server the privacy was secured by providing the authentication using Geopriv approach. This information from sensor nodes is further forwarded to base station where further computation is performed to determine the current position of object.

Void Fraction Measurement by the Improved Multi-Channel Impedance Void Meter (개량된 다채널 임피던스형 측정기에 의한 기포율의 측정)

  • Song, Cheol-Hwa;Jeong, Mun-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.384-398
    • /
    • 1996
  • An improved multi-channel Impedance Void Meter (IVM) is developed to measure an area-averaged void fraction. It consists of a main sensor, a reference sensor and a signal processor. The sensor was designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. Guard electrodes are used to obtain evenly distributed electrical field in a measuring volume. A reference sensor is also installed to eliminate the drift in void signal caused by the changes in electrical properties of working fluid. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. As an example of applications, the mean and fluctuating components of void fraction are measured for bubbly and slug flow regime, and it is shown that IVM has good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel.

A Clamp Type Sensor for AC/DC Low Current Measurement (클램프 형 직교류 저 전류 측정 센서)

  • 박영태;유광민
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.12
    • /
    • pp.1045-1053
    • /
    • 2002
  • This paper describes characteristics of the developed current sensor by means of two identically wound magnetic cores forming a clamp like for measurement of a low DC, or AC current. This sensor consists of peak value detectors, a sensor of an electrically compensated current transformer type, a reference alternating voltage, Precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC, or AC current. The current sensor shows a measurement accuracy of less than 0.3% in the frequency range 40 Hz - 10 HBz. The resolution and sensitivity of the sensor were evaluated 0.1 mA and 10 mV/mA, respectively.

Effect of the Sensor Location on Magnetocardiography (심자도 센서의 위치 효과에 대한 연구)

  • Lim, Hyun-Kyoon;Kim, Ki-Woong;Kwon, Hyuk-Chan;Lee, Yong-Ho
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Magnetocardiography (MCG) is a non-contact, non-invasive, and harmless diagnostic tool to detect the abnormal electrical conductivities of the heart caused by the various coronary artery disease or cardiac muscular disease. The purpose of this study is to identify whether MCG signals and MCG parameter values vary depending on the location of sensor assembly. It will be an important reference for the standard measurement. Four healthy male subjects (33.3$\pm$6.3 years) participated in this study. Basal recording was made at 20 mm apart from the chest surface. All subjects were requested to take a regular breathe while MCG was taken. The gap between the chest surface and the bottom of the sensor assembly was 20, 40, 60, and 80 mm. Recording was made using 64 channel MCG system (Axial type, first order gradiometer) developed by Korea Research Institute of Standards and Science (KRISS). After resting for two minutes in a supine position on the bed in magnetically shielded room, MCG were recorded for 30 s. As the sensor location is getting away from the chest surface signal, the amplitude of R and T wave peak decreases to 70% (at 40 mm gap), 50% (at 60 mm), and 37% (at 80 mm) of the reference strength measured (y = $1.3903e^{-0.0169x}$, $R^2$ = 0.99; where y=amplitude remained after reduction, x=distance between chest surface and sensor location). The regression equations may be used as a good reference to calculate how much strength will be decreased by the distance. In MCG parameters, most values of parameters were decreased as the gap was increased. As an example, the current moment at T-wave peak reduced to 52% (at 40 mm gap), 33% (at 60 mm), and 19% (at 80 mm). However, the difference caused by the gap could be reduced by considering the distance when the MCG parameters were calculated. The study results can be used as a useful reference to design the baseline and the sensor location.

  • PDF

Influence of Parameter Setting in an Oil Cooler on the Temperature Characteristics of an Ultra-precision Hydrostatic Table (초정밀 유정압 테이블에서 냉각장치의 변수 설정이 온도특성에 미치는 영향)

  • Khim, Gyungho;Kim, Chang Ju;Oh, Jeong Seok;Park, Chun Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.6
    • /
    • pp.571-576
    • /
    • 2015
  • Temperature characteristics of supply oil in an ultra-precision hydrostatic table are largely influenced by parameter setting in an oil cooler such as the location of reference sensor and cooling temperature. In this paper, influences of the parameter setting on the temperature variation in the hydrostatic table are experimentally analyzed to suggest the guidelines for practical application. In case of using temperature of inlet oil as a reference sensor in the oil cooler, temperature rise of the supply oil is smaller and thermal settling time is faster than that of using temperature of outlet oil as a reference sensor. The experimental results also show that temperatures of table, rail and return oil can be made almost same, and thermal settling time can be decreased by setting cooling temperature in the oil cooler to be lower than atmospheric temperature.

Self-positioning fusion system based on estimation of relative coordinates

  • Cho, Hyun-Jong;Lee, Sung-Geun;Cho, Woong-Ho;Noh, Duck-Soo;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.566-572
    • /
    • 2014
  • Recently, indoor navigation has been applied in large convention centers by using wireless sensor networks (WSNs), which provide not only a user's path to be traveled but also orientation and shopping information to increase user's convenience. This paper presents the localization system for estimating relative coordinates without pre-deployment of the reference node based on ultra wide band (UWB) ranging system, which is relatively suitable for indoor localization compared to other wireless communications, and azimuth sensor. The proposed localization system which consists of an azimuth sensor and a mobile node composed of three nodes estimates relative coordinates of the reference node without applying any recursive and time consumption algorithms. Also, in the process of estimating relative coordinates of the reference node, ranging errors are minimized through the proposed technique and the number of nodes can be reduced. Experimental results show the feasibility and validity of the proposed system.

A temperature sensor with low standard deviation with generating reference voltage for use in IoT applications (IoT 어플리케이션에서 활용하는 참조 전압을 같이 생성할 수 있는 표준 편차가 낮은 온도 센서)

  • Juwon Oh;Younggun Pu;Yeonjae Jung;Kangyoon Lee
    • Transactions on Semiconductor Engineering
    • /
    • v.2 no.2
    • /
    • pp.10-14
    • /
    • 2024
  • This paper presents a circuit design aimed at generating the required reference voltage and temperature sensor voltage in conjunction with an ADC, utilizing the current generated by temperature characteristics of BJT components for sensor data conversion. Additionally, two control methods are introduced to reduce the standard deviation of the circuit, resulting in over a ten-fold decrease in standard deviation. The proposed circuit occupies an area of 0.057mm2 and was implemented using 55nm RF process.

Simultaneous Faults Detection and Isolation Using Null Space Components of Faults for INS Sensor Redundancy

  • Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.32.4-32
    • /
    • 2002
  • We consider inertial navigation system (INS) sensor redundancy and propose a method which uses singular value decomposition to detect and isolate faults when even two sensors have faults simultaneously. When redundant sensor configuration is given, such as symmetric configuration in INS, the range space and null space of configuration matrix are determined. We use null space of configuration matrix and define 21 reference fault vectors which include 6 one-fault vectors and 15 two-fault vectors. Measurements are projected into null space of measurement matrix and compared with 21 normalized reference fault vectors, which determines fault detection and isolation.

  • PDF

Software PLL Based Speed Control of High Speed Miniature BLDC (소프트웨어 PLL 기반 소형 고속 BLDC의 속도 제어)

  • Park, Tae-Hub;Seok, Seung-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.132-135
    • /
    • 2008
  • This paper presents a PLL(Phase Lock Loop) control method for speed control of high speed miniature BLDCM(Brushless DC Motor) using hall sensor. The Proposed PLL based speed control method uses a only phase shift between reference pulse signal according to speed reference and actual pulse signal from hall sensor. It doesn't use any speed calculation, and calculates a direct current reference from phase shift. The current reference is changed to reduce the phase shift between reference and actual pulse. So the actual speed can keep the reference speed. The proposed control scheme is very simple but effective speed control is possible.

  • PDF

Development of a Real-time Radiation Level Monitoring Sensor for Building an Underwater Radiation Monitoring System (수중 방사선 감시체계 구축을 위한 실시간 방사선 준위 모니터링 센서 개발)

  • Park, Hye Min;Joo, Koan Sik
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.96-100
    • /
    • 2015
  • In the present study, we developed a real-time radiation-monitoring sensor for an underwater radiation-monitoring system and evaluated its effectiveness using reference radiation sources. The monitoring sensor was designed and miniaturized using a silicon photomultiplier (SiPM) and a cerium-doped-gadolinium-aluminum-gallium-garnet (Ce:GAGG) scintillator, and an underwater wireless monitoring system was implemented by employing a remote Bluetooth communication module. An acrylic water tank and reference radiation sources ($^{137}Cs$, $^{90}Sr$) were used to evaluate the effectiveness of the monitoring sensor. The underwater monitoring sensor's detection response and efficiency for gamma rays and beta particles as well as the linearity of the response according to the gammaray intensity were verified through an evaluation. This evaluation is expected to contribute to the development of base technology for an underwater radiation-monitoring system.