• Title/Summary/Keyword: Reference ranges

Search Result 248, Processing Time 0.028 seconds

Reference values for respiratory system impedance using impulse oscillometry in healthy preschool children

  • Park, Jye-Hae;Yoon, Jung-Won;Shin, Youn-Ho;Jee, Hye-Mi;Wee, Young-Sun;Chang, Sun-Jung;Sim, Jung-Hwa;Yum, Hye-Yung;Han, Man-Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.2
    • /
    • pp.64-68
    • /
    • 2011
  • Purpose: The normal values for lung resistance and lung capacity of children, as determined by impulse oscillometry (IOS), are different for children of different ethnicities. However, reference values there is no available reference value for Korean preschool children have yet to be determined. The aim of the present study was to determine the normal ranges of IOS parameters in Korean preschool children. Methods: A total of 133 healthy Korean preschool children were selected from 639 children (aged 3 to 6 years) who attended kindergarten in Seongnam, Gyeonggi province, Korea. Healthy children were defined according to the European Respiratory Society (ERS) criteria. All subjects underwent lung function tests using IOS. The relationships between IOS value (respiratory resistance (Rrs) and reactance (Xrs) at 5 and 10 Hz and resonance frequency (RF)) and age, height, and weight were analyzed by simple linear and multiple linear regression analyses. Results: The IOS success rate was 89.5%, yielding data on 119 children. Linear regression identified height as the best predictor of Rrs and Xrs. Using stepwise multiple linear regressions based on age, height, and weight, we determined regression equations and coefficients of determination ($R^2$) for boys ($Rrs_5=1.934-0.009{\times}Height$, $R^2$=12.1%; $Xrs_5=0.774+0.006{\times}Height-0.002{\times}Age$, $R^2$=20.2% and for girls $(Rrs_5=2.201-0.012{\times}Height$, $R^2$=18.2%; $Xrs_5=-0.674+0.004{\times}Height$, $R^2$=10.5%). Conclusion: This study provides reference values for IOS measurements of normal Korean preschool children. These provide a basis for the diagnosis and monitoring of preschool children with a variety of respiratory diseases.

Design of a DC-DC converter for intra-oral CMOS X-ray image sensors (Intra Oral CMOS X-ray Image Sensor용 DC-DC 변환기 설계)

  • Jang, Ji-Hye;Jin, Li-Yan;Heo, Subg-Kyn;Josonen, Jari Pekka;Kim, Tae-Woo;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2237-2246
    • /
    • 2012
  • A bias circuit required for an oral sensor is manufactured inside the oral sensor chip to reduce its size and cost. The proposed DC-DC converter supplies the required reference and bias currents for their corresponding regulators by using IREF of the reference current generator. Their target voltages of the voltage regulators are regulated by the negative mechanism by generating their reference voltages required for their corresponding regulators. In addition, a constant current IB0/IB1 is supplied by being mirrored by a current mirror ratio and then VREF is generated. It is confirmed by measurements that the average volatge, ${\sigma}$, and $4{\sigma}$ of the designed DC-DC converter for intra oral sensors with a $0.18{\mu}m$ X-ray CMOS process are within their required ranges. And the line-pair pattern image shows a high-resolution characteristic without blurring. Also, a good oral image can be obtained.

Hematologic and biochemical reference intervals for natural monument Korean goral (Naemorhedus caudatus) (천연기념물 한국 산양의 혈액 및 혈액 화학적 정상표준범위)

  • Ahn, Sangjin;Choi, Youngjin;Kim, Jong-Taek
    • Korean Journal of Veterinary Service
    • /
    • v.40 no.2
    • /
    • pp.155-159
    • /
    • 2017
  • Korean goral (Neamorhedus caudatus) is registered as a natural monument number 217 by South Korea Cultural Heritage Administration. It is also recognized as the endangered species I by Convention on International Trade in Endangered Species of Wild Fauna and Flora (CITES). In this study, blood samples of Korean goral were collected to make reference intervals. Blood sampling was conducted on 19 numbers of Korean gorals (ten females, nine males), which were reared in Korean Goral Restoration Center. For total samples, the reference intervals of hematological parameters were: white blood cell $7.69{\sim}10.87K/{\mu}{\Lambda}$; hematocrit 36.73~46.18%; red blood cell $10.72{\sim}12.86K/{\mu}{\Lambda}$; hemoglobin 12.79~15.14 g/dL; mean corpuscular volume 33.15~36.75 fL; mean corpuscular hemoglobin 11.53~12.23 pg; mean corpuscular hemoglobin concentration 32.64-35.91 g/dL and red blood cell distribution width 39.2~43.46%. For total samples of each parameters, the following results were obtained for serum biochemistry: glucose 111.81~153.77 mg/dL; blood urea nitrogen 22.35~28.91 mg/dL; creatine 1.22~1.84 mg/dL; phosphate 4.57~6 mg/dL; calcium 8.7~9.1 mg/dL; total protein 6.53~6.92 g/dL; albumin 3.1~3.48 g/dL; globulin 3.26~3.62 g/dL; alanine aminotransferase 56.7~158.56 U/L; aspartate aminotransferase 230.35~473.06 U/L; alkaline phosphatase 178.06~332.47 U/L; gamma-glutamyl transpeptidase 131.6-~181.24 U/L; total bilirubin 1.47~2.12 mg/dL; cholesterol 46.48~71.52 mg/dL; amylase 16.3~26.03 U/L; sodium 150.43~153.88 mmol/L; potassium 3.98~4.6 mmol/L and chlorine 109.48~113.26 mmol/L. The ranges of values were similar campared to previous studies except in the case of RDW value, which showed higher range than the RDW value of a previous study. The reference intervals from this study will be useful data for treatment and management of gorals.

The Dynamic Basement Amplification Characteristics of a Dam Site using a Reference Site Method (기준관측소 방법을 이용한 댐체 기반암의 동적 지반증폭특성)

  • Wee, Soung-Hoon;Kim, Jun-Kyoung;Yoo, Seong-Hwa
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.161-171
    • /
    • 2017
  • Observed ground motions are composed of three factors such as, seismic source, attenuation, and site amplification effect. Among them, the site amplification characteristics should be considered significantly when estimating seismic source and attenuation characteristics with more confidence. The site effect is also necessary when estimating not only seismic hazard in seismic design engineering but also rock mechanical properties. This study uses the method of H/V spectral ratio of observed ground motion between target site and reference site called a reference site method. In addition to using the vertical Fourier spectrum of the reference site, we try out the horizontal Fourier spectrum as a new method in this study. We analyze H/V spectral ratio of six ground motions respectively, observed at four sites close to Yedang Reservoir. We then compare site amplification effects at each site using 3 kinds of seismic energies including S waves, Coda waves energy, and background noise. The results suggest that each site showed similar site amplification patterns in S waves and Coda waves energy. However, the site amplification of background noise shows much different characteristics from those of S waves and Coda wave energy, which suggests that the background noises at each site have their own developing mechanism. Each station shows its own characteristics of specific resonance frequency and site amplification properties in low, high and specific resonance frequency ranges. Comparison of the method used in this study to the others that used different methods can provide us with more information about the dynamic amplification of a site characteristics and site classification.

Pattern Development of Waist / Abdominal Area of Obese Womem Using 3D Geometrical Model (3D모델을 이용한 비만체형 여성의 허리-배 부위 패턴 특성 연구)

  • Kim, So-Young;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.7 s.144
    • /
    • pp.1018-1026
    • /
    • 2005
  • Recent development of 3D scanner and software is regarded as a promising method of acquiring replicas from human body indirectly. It would be very helpful if we could predict the characteristics of 2D pattern from the simple parameters related to 3D shape for ordinary user. Therefore, in this study, investigation of 2D pattern of waist/abdominal area from the 3D geometrical model was conducted for the pattern development of waist nipper. To create body models and develop the surface of them, one ortho commonly used CAD/CAM program, IDEAS(UGS-plm solutions, USA) was used. As for the size of the models, the width, thickness, and circumference ranges of adult women's torso reported in National Anthropometric Survey of Korea (1997) were used as a standard model. Seven size variations were made by changing the width of the waist only, from 19 cm to 40 cm. Therefore, simulated body models include not only the normal body but also obese body who has wider waist and abdomen width than hip width. As results, it was found that the curvature of the unfolded 2D pattern around the abdominal area decreases as the waist width increases. As the width of the waist increases more and more, so that the comparative ratios around the torso becomes in abnormal ranges, there appears inflection points and the direction of curvature was changed. 2D Patterns obtained in this research were quantified by curvature, length of the curve and angle of deflection in the reference frame box for the convenience of the actual pattern making process. It was also possible to find that the shape of patterns of abnormal body resulted in a quite interesting change in the curves of 2D pattern, which could be applied to the custom made waist nipper for obese women.

Design of Ultra Wide Band MMIC Digital Attenuator with High Attenuation Accuracy (높은 감쇠 정확도를 가지는 초광대역 MMIC 디지털 감쇠기 설계)

  • Ju Inkwon;Yom In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.101-109
    • /
    • 2006
  • A broadband, DC to 40 GHz 5-bit MMIC digital attenuator has been developed. The ultra broadband attenuator has been achieved by adding transmission lines in the conventional Switched-T attenuator and optimizing the transmission line parameters. Momentum simulation was performed in design for accurate performance prediction at high frequencies and Monte Carlo analysis was applied to verify the performance stability against the MMIC process variation. The attenuator has been fabricated with $0.15\;{\mu}m$ GaAs pHEMT process. This attenuator has 1 dB resolution and 23 dB dynamic ranges. High attenuation accuracy has been achieved over all attenuation ranges and 40 GHz bandwidth with the reference state insertion loss of less than 6 dB at 20 GHz. The input and output return losses of the attenuator are better than 14 dB over all attenuation states and frequencies. The measured IIP3 of the attenuator is 33 dBm.

Garment Sizes Analysis on Target Ages and Body Shapes (신체 특성에 따른 타겟 연령별 치수 호칭 설정 - KS 규격 및 신체 치수 분석을 바탕으로 -)

  • Kang, Yeo-Sun
    • The Research Journal of the Costume Culture
    • /
    • v.15 no.1 s.66
    • /
    • pp.137-151
    • /
    • 2007
  • This study was performed to narrow down the Sizing System for Female Adult's garments(KS K 0051) following age target and body shapes. The study was based on the sizing system and the anthropometric measurements, called Size-Korea, which were surveyed in the years 2003 and 2004. At first, the subjects of the survey were classified into 4 age groups, $18{\sim}24,\;25{\sim}34,\;35{\sim}49\;and\;50{\sim}59$, based on the most significant differences of body sizes. Secondly, the ranges of four key dimensions - height, bust, waist and hip-of normal sizes were identified through analyzing Rohrer index and percentile. The selected sizes within the ranges were grouped by the drop which was the subtraction of bust girth from hip girth. In conclusion, there was the most frequent drop for each age group; 9cm drop for the $18{\sim}24$ years old group, the 6cm drop for the $25{\sim}34$ years old and $35{\sim}49$ years old and 3cm drop for $50{\sim}59$ years old. The upper body garment sizes of the same drop and target ages could be merged to 10 to 12 sizes, which were remarkably smaller than the Female Adult garment sizing system, and further to 2-5 sizes, considering the percentile importance. However, $50{\sim}59$ years old group needed to be analyzed in different ways, because the number of subjects of normal size in the age decreased rapidly, that the normal sizes for them were very limited. In addition, the reference body sizes of each garment size were apparently different when they were compared to each age groups. These basic data for garment size specification could be usefully adapted for the apparel companies' own sizing system according to their age target and body shapes, to achieve efficient production and better fit.

  • PDF

Simulation-based Yield-per-recruit Analysis of Pacific Anchovy Engraulis japonicus in the Korea Strait with Varying Fisheries Regulations (모의실험을 통한 남해 멸치(Engraulis japonicus)의 어획조건에 따른 가입당 생산 분석)

  • Lee, Kyunghwan;Go, Seonggil;Jung, Sukgeun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.4
    • /
    • pp.437-446
    • /
    • 2017
  • To evaluate the consequences of possible fisheries regulations of anchovy Engraulis japonicus in the Korea Strait, we developed and applied a simulation-based yield-per-recruit (Y/R) model that considered temperature-dependent growth and size-dependent mortality, covering the egg to adult stages. We projected changes in commercial yield and egg production of anchovy with respect to varying biological reference points of 1) the instantaneous fishing mortality, 2) the minimum fork length of anchovy allowed to catch for protecting smaller anchovy ($L_{c,min}$), and 3) the maximum fork length allowed to catch for protecting bigger anchovy ($L_{c,max}$). Our Y/R model showed that the anchovy yield will be maximized at ca. $1.4{\times}10^6tons$ when $L_{c,min}$ ranges between 42-60 mm or at ca. $0.8{\times}10^6tons$ when $L_{c,max}$ ranges from 88-160 mm. At $L_{c,min}=30mm$, the present minimum length of catch, our simulations indicated that the anchovy yield can reach a maximum of $1.2{\times}10^6tons$ in the long-term when the present fishing effort, which annually yields ca. $0.2{\times}10^6tons$ of anchovy, can be increased by a factor of 28. We expect that our simulation-based Y/R model can be applied to other commercially-important small pelagic species in which the traditional Beverton-Holt Y/R model is difficult to apply.

Matching Points Extraction Between Optical and TIR Images by Using SURF and Local Phase Correlation (SURF와 지역적 위상 상관도를 활용한 광학 및 열적외선 영상 간 정합쌍 추출)

  • Han, You Kyung;Choi, Jae Wan
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.1
    • /
    • pp.81-88
    • /
    • 2015
  • Various satellite sensors having ranges of the visible, infrared, and thermal wavelengths have been launched due to the improvement of hardware technologies of satellite sensors development. According to the development of satellite sensors with various wavelength ranges, the fusion and integration of multisensor images are proceeded. Image matching process is an essential step for the application of multisensor images. Some algorithms, such as SIFT and SURF, have been proposed to co-register satellite images. However, when the existing algorithms are applied to extract matching points between optical and thermal images, high accuracy of co-registration might not be guaranteed because these images have difference spectral and spatial characteristics. In this paper, location of control points in a reference image is extracted by SURF, and then, location of their corresponding pairs is estimated from the correlation of the local similarity. In the case of local similarity, phase correlation method, which is based on fourier transformation, is applied. In the experiments by simulated, Landsat-8, and ASTER datasets, the proposed algorithm could extract reliable matching points compared to the existing SURF-based method.

A Zinc Porphyrin Sensitizer Modified with Donor and Acceptor Groups for Dye-Sensitized Solar Cells

  • Lee, Seewoo;Sarker, Ashis K.;Hong, Jong-Dal
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.3052-3058
    • /
    • 2014
  • In this article, we have designed and synthesized a novel donor-${\pi}$-acceptor (D-${\pi}$-A) type porphyrin-based sensitizer (denoted UI-5), in which a carboxyl anchoring group and a 9,9-dimethyl fluorene were introduced at the meso-positions of porphyrin ring via phenylethynyl and ethynyl bridging units, respectively. Long alkoxy chains in ortho-positions of the phenyls were supposed to reduce the degree of dye aggregation, which tends to affect electron injection yield in a photovoltaic cell. The cyclic voltammetry was employed to determine the band gap of UI-5 to be 1.41 eV based on the HOMO and LUMO energy levels, which were estimated by the onset oxidation and reduction potentials. The incident monochromatic photon-to-current conversion efficiency of the UI-5 DSSC assembled with double-layer (20 nm-sized $TiO_2$/400 nm-sized $TiO_2$) film electrodes appeared lower upon overall ranges of the excitation wavelengths, but exhibited a higher value over the NIR ranges (${\lambda}$ = 650-700 nm) compared to the common reference sensitizer N719. The UI-5-sensitized cell yielded a relatively poor device performance with an overall conversion efficiency of 0.74% with a short circuit photocurrent density of $3.05mA/cm^2$, an open circuit voltage of 0.54 mV and a fill factor of 0.44 under the standard global air mass (AM 1.5) solar conditions. However, our report about the synthesis and the photovoltaic characteristics of a porphyrin-based sensitizer in a D-${\pi}$-A structure demonstrated a significant complex relationship between the sensitizer structure and the cell performance.