• Title/Summary/Keyword: Reference ranges

Search Result 248, Processing Time 0.029 seconds

Formulation of a reference coordinate system of three-dimensional (3D) head & neck images: Part I. Reproducibility of 3D cephalometric landmarks (3차원 두부영상의 기준좌표계 설정을 위한 연구: 1부 CT영상에서 3차원 계측점의 재현성)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.388-397
    • /
    • 2005
  • The purpose of this study was to redefine the cephalometric landmarks in three-dimensional (3D) images, which are used in orthodontic cephalometric radiography, and to evaluate the reproducibility of each landmark for 3D cephalometric analysis. Eighteen CT scans were taken at the Department of Diagnostic Radiology at Seoul National University Dental Hospital and manipulated with V works 4.0(Cybermed Inc., Seoul, Korea). The coordinate system was established using 7 reference points, with no more than 4 points on the same plane. These 7 points were generated as a volume model, the voxel size of which was 4 by 4 by 2 (threshold value=639). The cephalometric landmarks were selected at the multiplanar reformation (MPR) window on the volume mode of V works 4.0. The selected landmarks were exported to V surgery (Cybermed Inc., Seoul, Korea) for the calculation of coordinate values. All the data were taken twice with a lapse of 2 weeks by one investigator The reproducibility of each landmark was $0.17\~1.21mm$ in the x axis, $0.30\~1.53mm$. In the y axis, and $0.27\~1.81mm$ in the z axis. In all three axes, the range of error was similar. These error ranges were acceptable with regards to the pixel space and slice thickness. The most reproducible points were 1 points which were selected on the basis of the volume model. The least reproducible points were J points that were defined by sutures.

Reference Ranges of Microalbumin Using Fasting Urine (Fasting Urine을 사용한 Microalbumin의 참고치에 관한 연구)

  • Kim, Ji-Young;Jin, Kwang-Ho;Bae, Ae-Young;Kim, Ye-Na;Seo, Sang-Won;Lee, Na-Ree;Jeon, Ha-Young;Shin, Sook-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.208-211
    • /
    • 2006
  • Microalbuminuria is most frequently caused by kidney damage from diabetes. Moreover, many other conditions can lead to kidney damage, such as high blood pressure, heart failure, cirrhosis, or systemic lupus erythematosus (SLE). The measurement of the microalbumin in urine may be useful for the early diagnosis or as a predictor of nephropathy in diabetes. The most common method for getting a quantitative measurement of urinary protein relies on a 24-hour urine collection. The result of this method is accurate. But 24hr urine collection is difficult to obtain and variations in volume are frequent. Also the patients complain about urine collection. We tried to measure reference values for microalbumin using fasting urine and compare them with the albumin/creatinine ratio using 24hr urine. The concentrations of microalbumin in fasting urine and 24hr urine were $7.1{\pm}3.8mg/L$, $5.7{\pm}2.9mg/L$ (r=0.61, p=0.27), respectively. The albumin/creatinine ratios using fasting urine and 24hr urine were $8.7{\pm}4.2{\mu}g/mg$, $8.7{\pm}4.0{\mu}g/mg$ (r=0.76, p=0.88), respectively. This study indicated that the measurement of microalbumin in fasting urine was an easy and simple method for early diagnosis or to predict nephropathy in diabetes. Thus, setting up the reference value using fasting urine may be useful in the screening test for the diabetic nephropathy patients instead of using the 24hr albumin excretion rate (AER).

  • PDF

A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography (소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구)

  • Kim, Hyeon-Jin;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.161-169
    • /
    • 2016
  • In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the busan regional hospitals, to the national diagnostic reference levels. As a result, it was appeared to exceed the amount of the dose recommendation in order of hospital, general hospital and senior general hospital in the hospital-specific classification and from 2 to 5 year, from 1 month to 1 year and from 6 to 10 year in the age-specific classification. In addition, the amount of the dose recommendation was exceed in order of helical, axial and volume in the scan-specific classification. As the results of the scan range reset to match the diagnostic reference level, the dose reduction showed 11.68%, 15.79% and 20.66% in senior general hospital, general hospital and hospital respectively. In the results of analysing patient average scan ranges which does not deviate from the guideline of patient dose recommendation, there was age of 1 month to 1 year, 2 to 5 year and 6 to 10 year of $03.2{\pm}11.8mm$, $110.5{\pm}14.5mm$, and $117.8{\pm}17.2mm$ respectively.

2020 Korean Dietary Reference Intakes for Protein: Estimation of protein requirements and the status of dietary protein intake in the Korean population (2020 단백질 섭취기준: 결핍과 만성질환 예방을 위한 한국인의 단백질 필요량 추정과 섭취현황)

  • Kim, Eunjung;Chung, Sangwon;Hwang, Jin-Taek;Park, Yoon Jung
    • Journal of Nutrition and Health
    • /
    • v.55 no.1
    • /
    • pp.10-20
    • /
    • 2022
  • This article evaluated levels of Estimated Average Requirements (EARs), Reference Nutrient Intakes (RNIs), and Acceptable Macronutrient Distribution Ranges (AMDRs) of protein using the recently revised Dietary Reference Intakes (DRIs) for Koreans (2020). Dietary protein requirements are based on amounts sufficient to satisfy physiological demands to accomplish nitrogen equilibrium. The same principle was applied to estimate EARs and RNIs, for adults in DRIs conducted in 2015 and 2020 in Koreans. EAR was estimated to be 0.73 g/kg body weight/day, according to data (0.66 g/kg body weight/day) obtained using the nitrogen balance method and adjusted by efficiency of protein use (90%). RNI was calculated as EAR increased by an amount equal to twice the standard deviation of an age group so as to cover 97.5% of the group and was found to be 0.91 g/kg body weight/day. For weaned infants, children, and adolescents, growth requirement was added to estimate EAR. In particular, growth requirement was adjusted by efficiency of protein use in the revised EAR, which led to higher EARs for weaned infants, children, and adolescents of both genders as compared with 2015 DRIs. The AMDR for protein was set at 7%-20% of energy intake, which was the same as 2015 DRIs. Current, average protein intake by the Korean population is almost twice times the EAR, which suggests it might be better to increase the minimal margin for AMDR. However, it was not adjusted in this revision due to lack of evidence.

Influence of Temperature on the Survival, Growth and Sensitivity of Benthic Amphipods, Mandibulophoxus mai and Monocorophium acherusicum (국내산저서단각류 Mandibulophoxus mai와 Monocorophium acherusicum의 생존, 성장 및 민감도에 대한 온도의 영향)

  • Lee Kyu-Tae;Lee Jung-Suk;Kim Dong-Hoon;Kim Chan-Kook;Park Kun-Ho;Kang Seong-Gil;Park Gyung-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • A series of experiments was conducted to evaluate the effects of temperature on the survival, growth and sensitivity of the benthic amphipods, Mandibuluphoxus mai and Monocnrophium acherusicum, which have been recently developed as new sediment toxicity testing species in Korea. The biological performance for each amphipod species was determined by the survival and growth rates at different water temperatures. The influence of temperature on the sensitivity to reference toxicant, Cd, was determined by the comparison of survival rates of amphipods exposed to control and Cd-spiked seawater at different temperatures. Temperature significantly influenced on the survival, growth and Cd sensitivity of both amphipods. Tolerable ranges of temperature for the >80% individuals of both M. mai and M. acherusicum with sediment substrates were mostly overlapped (13 to 22℃). The daily growth rates of M. mai and M. acherkisicum increased proportionally with temperature up to 20℃ and 25℃. respectively. Similarly, the sensitivities of M. mai and M. acheyusicum to Cd increased with temperature up to 20℃ and 15℃, respectively. Overall results showed that temperature is a substantially important factor potentially influencing the results of lethal and sublethal bioassays using the amphipods. Therefore, defining the adequate ranges of experimental temperature for the toxicity testing species is the pre-requisite for the development of standardized bioassay protocols.

  • PDF

Assessment of Aging Effects on Computed Tomographic Glomerular Filtration Rate in Dogs (개에서 연령에 따른 동적 컴퓨터단층촬영을 이용한 사구체여과율의 평가)

  • Chang, Jin-Hwa;Kim, Hwan-Cheol;Choi, Ji-Young;Choi, Ho-Jung;Lee, Hee-Chun;Chang, Dong-Woo;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.130-133
    • /
    • 2012
  • The purpose of this study is to assess the relationship between glomerular filtration rate (GFR) and age by using dynamic computed tomography (CT) and Patlak plot analysis in dogs. Fifteen dogs were used in this study. CT-GFR study was performed under general anesthesia using propofol and isoflurane. 1 ml/kg dosage of 300 mgI/ml iohexol was administered at a rate of 3 ml/s during GFR measurement. CT-GFR was determined with a single-slice dynamic acquisition and Patlak plot analysis. The individual and global GFR values were calculated to plasma clearance per body weight (ml/min/kg). Bodyweight ($mean{\pm}SD$) ranged from 2.0 to 5.7 kg ($3.31{\pm}1.13$ kg). Age ranged from 3 years to 13 years old ($7.14{\pm}3.30$). $Mean{\pm}SD$ creatinine ($0.53{\pm}0.34 $mg/dl), phosphorus ($4.1{\pm}1.2$ mg/dL), and albumin ($3.3{\pm}0.3$ mg/dL) concentrations and urine protein-to-creatinine ratios (all ratios were < 0.5) were within reference ranges. Abdominal ultrasonography revealed small-sized renal calculi, mineralization, or renal cyst at eight dogs. The global CT-GFR ranges shown in this study was 2.57 to 6.60 ml/min/kg. In this study, there was no trend toward weight-adjusted CT-GFR with increasing age. We found no relationships between age-related kidney dysfunction in fifteen dogs. Small-sized renal calculi or cysts did not affect renal function in this study. However, it is thought that a large sample size may have been required to document an age effect.

Mode of Occurrence and Chemical Composition of Electrums from the Gubong Gold-Silver Deposits, Republic of Korea (구봉 금-은광상에서 산출되는 에렉트럼의 산출상태와 화학조성)

  • 유봉철;최선규;이현구
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.191-201
    • /
    • 2002
  • The Gubong gold-silver deposits if gold-silver-bearing hydrothermal massive quartz veins which were filled the fractures along fault shear (NE, NW) zones within Precambrian banded or granitic gneiss of Gyeonggi massif. Ore mineralization of this deposits is contained within a single stage of quartz vein which was formed by multiple episodes of fracturing and healing. Ore minerals are comported mainly of arsenopyrite, pyrite, sphalerite, chalcopyrite, galena with minor amounts of pyrrhotite, marcasite and electrum. The frequency and volume percentages of electrum associated with ore minerals from this deposits are recognized as follows; 44.5% and 54.3% with arsenopyrite, 24.3% and 33.8% with quartz, 12.6% and 0.1% with pyrite, 11.0% and 4.8% with galena, 5.0% and 7.0% with sphalerite and 2.5% and 0.02% with chalcopyrite, respectively. They show irregular (41.6%), subround (34.7%), elongate (17.0%) and granular (6.6%) shapes, respectively. Their grain size ranges from 2 to 150 um, but 90.9 percent of the grains are below 30 um. The chemical composition of electrums ranges from 26.39 to 72.51 Au atomic %. These composition (Au atomic %) on the basis of associated minerals are from 44.97 to 71.75 with arsenopyrite, pyrite, sphalerite and quartz, from 44.37 to 72.51 with quartz, from 35.40 to 41.01 with sphalerite and chalcopyrite, from 26.39 to 54.84 with pyrite, chalcopyrite, quartz and galena, from 28.49 to 53.28 with galena, respectively. We suggest that optimum recovery of gold would be obtained with reference to these results.

Multi-view Video Coding using View Interpolation (영상 보간을 이용한 다시점 비디오 부호화 방법)

  • Lee, Cheon;Oh, Kwan-Jung;Ho, Yo-Sung
    • Journal of Broadcast Engineering
    • /
    • v.12 no.2
    • /
    • pp.128-136
    • /
    • 2007
  • Since the multi-view video is a set of video sequences captured by multiple array cameras for the same three-dimensional scene, it can provide multiple viewpoint images using geometrical manipulation and intermediate view generation. Although multi-view video allows us to experience more realistic feeling with a wide range of images, the amount of data to be processed increases in proportion to the number of cameras. Therefore, we need to develop efficient coding methods. One of the possible approaches to multi-view video coding is to generate an intermediate image using view interpolation method and to use the interpolated image as an additional reference frame. The previous view interpolation method for multi-view video coding employs fixed size block matching over the pre-determined disparity search range. However, if the disparity search range is not proper, disparity error may occur. In this paper, we propose an efficient view interpolation method using initial disparity estimation, variable block-based estimation, and pixel-level estimation using adjusted search ranges. In addition, we propose a multi-view video coding method based on H.264/AVC to exploit the intermediate image. Intermediate images have been improved about $1{\sim}4dB$ using the proposed method compared to the previous view interpolation method, and the coding efficiency have been improved about 0.5 dB compared to the reference model.

Application of Veterinary Chemistry Analyzer used to Hematological Analysis of Marine fish Cultured in Floating Netcage (해상가두리 양식장 어류의 혈액 검사에 사용된 동물용 생화학 분석장치의 활용 가능성)

  • Jung, Sung-Hee;Jee, Bo-Young;Byun, Soon-Gyu;Choi, Hye-Sung
    • Journal of fish pathology
    • /
    • v.19 no.3
    • /
    • pp.253-265
    • /
    • 2006
  • The purpose of this study was to obtain reference data of parameters for hematological health diagnosis in marine fish and also evaluate application of veterinary chemistry analyzer used to those blood tests. A blood profile of total 522 fish for black rockfish (Sebastes schlegeli), red seabream (Pagrus major), rock bream (Oplegnathus fasciatu) and black seabream (Acanthopagrus schlegeli) cultured in mari-floating netcage of Gyeongnam province was determined by hematocrit (Ht), hemoglobin (Hb) and blood chemistry tests (total protein, albumin, alkaline phosphatase, blood urea nitrogen, lactate dehydrogenase, triglyceride, total cholesterol, creatinine, aspartate aminotransferase, alanine aminotransferase, glucose). Ht was measured by microhematocrit method. Hb and plasma chemistry were analysed by establishing baseline ranges for a dry chemical system of FUJI DRI-CHEM 3000. Actually recorded values of Hb and plasma chemistry by the analyzer were notably outside from the minimum and/or maximum of the established reference value. Albumin and alanine aminotransferase were not detectable in the range of 68~66%. Lactate dehydrogenase, total protein, alkaline phosphatase and glucose were not detectable in the range of 42~21%. Total cholesterol, aspartate aminotransferase, triglyceride, hemoglobin and creatinine were not detectable in the range of 18~3%. However, the values of blood urea nitrogen were below the detectable limits of the analyzer.

A Study on the Imputation for Missing Data in Dual-loop Vehicle Detector System (차량 검지자료 결측 보정처리에 관한 연구 (이력자료 활용방안을 중심으로))

  • Kim, Jeong-Yeon;Lee, Yeong-In;Baek, Seung-Geol;Nam, Gung-Seong
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.7 s.93
    • /
    • pp.27-40
    • /
    • 2006
  • The traffic information is provided, which based on the volume of traffic, speed, occupancy collected through the currently operating Vehicle Detector System(VDS). In addition to the trend in utilization fold of traffic information is increasing gradually with the applied various fields and users. Missing data in Vehicle detector data means series of data transmitted to controller without specific property. The missing data does not have a data property, so excluded at the whole data Process Hence, increasing ratio of missing data in VDS data inflicts unreliable representation of actual traffic situation. This study presented the imputation process due out which applied the methodologies that utilized adjacent stations reference and historical data utilize about missing data. Applied imputation process methodologies to VDS data or SeoHaeAn/Kyongbu Expressway, currently operation VDS, after processes at missing data ratio of an option. Imputation process held presented to per lane-30seconds-period, and morning/afternoon/daily time scope ranges classified, and analyzed an error of imputed data preparing for actual data. The analysis results, an low error occurred relatively in the results of the imputation process way that utilized a historical data compare with adjacent stations reference methods.