• Title/Summary/Keyword: Reference phase

Search Result 1,368, Processing Time 0.03 seconds

Torque Ripple Minimization of BLDC Motor Including Flux-Weakening Region (약계자영역을 포함한 BLDC 전동기의 새로운 토크 리플 최소화 방법)

  • 원태현;박한웅;이만형
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.6
    • /
    • pp.445-454
    • /
    • 2002
  • Torque ripple control of brushless DC motors has been the persisting issue of the servo drive systems in which the speed fluctuation, vibration and acoustic noise should be minimized. In this paper, a novel approach to achieve the ripple-free torque control with maximum efficiency based on the d-q reference frame is presented and analyzed. The proposed approach can provide the optimized phase current waveforms over wide speed range incorporating cogging torque compensation without an access to the neutral point of the motor windings. Moreover, the undesirable errors caused by the assumptions such as 3 phase balance or symmetry of the phase back EMF between electrical cycles, which are related with the manufacturing imperfections, can be also eliminated. As a result, the proposed approach provides a simple and clear way to obtain the optimal motor excitation currents. A hysteresis current control system is employed to produce high-frequency electromagnetic torque ripples for compensation. The validity and applicability of the proposed control scheme to real situations are verified through the simulations and experimental results.

Implementation of optical memory system using angular multiplexing method (각도 다중화 방법을 이용한 광 메모리 시스템의 구현)

  • 김철수;김성완;박세준;김종찬;송재원;김수중
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.101-109
    • /
    • 1998
  • In this paper, we implemented holographic optical memory systm which can store and reconstruct many images using new input and angular multiplexing method. In the new input method, phase infomation of input image is inputed in the recording material instead of brightness information. To do so, we represented the images, which captured with CCD camera or displayed on the computer monitor, on the liquid crystal television(LCTV) which removed polarizer/analyzer. Therefore, we can generate uniform input beam intensity regardless of the total brightness of input image, and apply the scheduled recording method. Also we can increase the intensity of input beam so reduce the recording time of input image. And reconstructedimage is acquired by transforming phase information into brightness information of image with analyzer. The incident angle of reference beam is acquired by Fourier transform of the binary phase hologram(BPH) which designed with SA algorithm on the LCTV. The proposed optical memory system is stable because the incident angle of the reference beam is controlled easy and electronically. We demonstreated optical experiment which store and reconstruct various type images in BaTiO$_{3}$ using proposed holographic memory system.

  • PDF

A Coarse Frequency Offset Estimation Based on the Differential Correlation in DAB Systems

  • Kim, Han-Jong;Paik, Jong-Ho;Park, Cheol-Hee;You, Young-Hwan;Ju, Min-Chul;Jin-Woong
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.105-111
    • /
    • 2001
  • This paper presents a new and robust technique for a coarse frequency offset estimation in OFDM systems. As an evaluation of the proposed algorithm, we apply it to Eureka 147 DAB system. The proposed coarse frequency offset estimation algorithm is based on the differential detection technique between adjacent subcarriers to eliminate the phase shift effects of symbol timing offset and fractional frequency offset. A coarse frequency offset is determined from the correlation output between a received interarrier differential phase reference symbol and several locally generated but frequency-shifted intercarrier differential phase reference symbols. The performance of our estimation algorithm is evaluated by means of computer simulation and is compared with those of previous proposed algorithms for DAB transmission modes I, II, III, and IV. Simulation results show that the proposed algorithm generates extremely accurate estimates with low complexity irrespective of the symbol timing offset.

  • PDF

Single-Phase Active Power Filter for Higher-order Harmonic Current Compensation (고차 고조파 전류의 보상을 위한 단상 능동전력필터)

  • Sung, Ki-Suk;Woo, Myung-Ho;Song, Joong-Ho;Choy, Ick;Lim, Myo-Taeg
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.7
    • /
    • pp.500-508
    • /
    • 2000
  • Basic design for single-phase active power filter, which aims at railway application provided with PWM-controlled converters, is comprehensively studied and its performance is presented in this paper. Active power filters are used to compensate railway signaling and public telecommunication interference due to the high-order harmonic currents generated in railway traction locomotives. A type of hybrid digital filter which is composed of low pass filter and high pass filter is proposed so that the desired harmonic reference current with accurate magnitude and phase shift can be extracted from catenary line current. A design criteria to determine input inductor L and output capacitor C is also described, considering voltage, current, PWM pattern, and switching frequency of the main converters. Finally, computer simulation and DSP-based experiments resulted from laboratory test are presented.

  • PDF

Three-dimensional relative-distance measurement by use of the phase-shifting digital holography (위상천이 디지털 홀로그래피를 이용한 3차원 상대 거리 측정)

  • Kim, Hyun;Lee, Yeon-H.
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.2
    • /
    • pp.200-207
    • /
    • 2003
  • In this paper we present a new method of measuring the relative distance of two point objects in three-dimensional space by using phase-shifting digital holography. In our system the reference beam of a spherical wave is used instead of a plane wave. The system is computer simulated and built on an optical table for experiments. It is shown from computer simulations and experiments that the relative distance can be measured without the exact information on the reference beam used in the hologram record. It is shown from experiments that the relative distance between two point objects separated by 0.5 cm in the distance of about 300 cm from the CCD can be measured with an error less than 10%.

Study on the Improvement of the Positioning Accuracy for Inverted RTK Using FARA (FARA를 이용한 Inverted RTK 측위 정확도 향상에 대한 연구)

  • Choi Byung Kygu;Lim Sam Sung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.22 no.3
    • /
    • pp.217-223
    • /
    • 2004
  • In order to improve real-time positioning accuracy, a number of methods have been tested and one of those is the inverted RTK(Real-time kinematic) that gives a precise positioning by handling carrier phase measurements. For the inverted RTK positioning, it needs the L1 phase measurement at least for 1~2 minutes and the additional reference stations/communication system and a data processing server are required. The L1 code and carrier phase measurements for real-time application are used simultaneously and then Kalman filter is applied to estimate integer ambiguities. Double differenced integer ambiguities are resolved by utilizing the FARA(Fast Ambiguity Resolution Approach). In this paper, we propose the method to improve the positioning accuracy and performed the field tests for several baselines from DAEJ reference station in KAO(Korea Astronomy Observatory).

Input Voltage Sensorless Control for 3 Phase Vienna Rectifier (3상 비엔나 정류기 입력 전압 센서리스 제어)

  • Lee, Sang-Ri;Kim, Hag-Wone;Cho, Kwan-Yuhl;Hwang, Soon-Sang;Yoon, Byung-Chul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.71-79
    • /
    • 2014
  • In this paper, a new grid voltage estimation algorithm without voltage sensors is proposed for the three-phase vienna rectifier. Generally, input voltage sensor circuits increase size and cost of the PWM rectifier In order to reduce the cost and size and in order to increase reliability from the electrical noise, grid voltage estimation scheme without input voltage sensor is highly required. In this paper, the grid voltage estimation algorithm is proposed by a simple MRAS(Model Reference Adaptive System) observer without input voltage sensors. The validity of the proposed method is proven by simulation and experiment on the three-phase vienna rectifier system.

Modelling and Performance Analysis of UPQC with Digital Kalman Control Algorithm under Unbalanced Distorted Source Voltage conditions

  • Kumar, Venkateshv;Ramachandran, Rajeswari
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1830-1843
    • /
    • 2018
  • In this paper, the generation of a reference current and voltage signal based on a Kalman filter is offered for a 3-phase 4wire UPQC (Unified Power Quality Conditioner). The performance of the UPQC is improved with source voltages that are distorted due to harmonic components. Despite harmonic and frequency variations, the Kalman filter is capable enough to determine the amplitude and the phase angle of load currents and source voltages. The calculation of the first state is sufficient to identify the fundamental components of the current, voltage and angle. Therefore, the Kalman state estimator is fast and simple. A Kalman based control strategy is proposed and implemented for a UPQC in a distribution system. The performance of the proposed control strategy is assessed for all possible source conditions with varying nonlinear and linear loads. The functioning of the proposed control algorithm with a UPQC is scrutinized and validated through simulations employing MATLAB/Simulink software. Using a FPGA SPATRAN 3A DSP board, the proposed algorithm is developed and implemented. A small-scale laboratory prototype is built to verify the simulation results. The stated control scheme for the UPQC reduces the following issues, voltage sags, voltage swells, harmonic distortions (voltage and current), unbalanced supply voltage and unbalanced power factor under dynamic and steady-state operating conditions.

Space Vector PWM Technique for Two-Phase Inverter-Fed Two-Phase Induction Motors (2상 유도전동기의 구동을 위한 2상 인버터의 2상 공간전압벡터 PWM 방식)

  • 장도현;윤덕용
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • In this paper the space voltage vector pulsewidth modulation(SVPWM) technique for two-phase inverter is proposed. The two-phase SVPWM technique is applicable to two-phase induction motor drives. The two-phase inverter using two-phase SVPWM technique cannot generate zero voltage vectors, but four space vectors. A reference voltage vector in the square locus is realized by adjusting four space vectors. The switching sequence "two-phase symmetrical modulation" used in two-phase SVPWM is proposed. Practical verification of theoretical predictions is presented to conform the capabilities of the new technique.technique.

Design of Charge pump for Removing Spur by Input Reference (기준입력신호로 인한 Spur 제거용 차지펌프 설계)

  • 이준호;김선홍;김영랄;김재영;김동용
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.209-212
    • /
    • 2000
  • Charge pump based upon a phase locked loop(PLL) is described. This charge pump show that it is possible to overcome the issue of charge pump current mismatch by using a current subtraction circuit. Also, this charge pump can suppress reference spurs and disturbance of the VCO control voltage. HSPICE simulations are performed using 0.25$\mu\textrm{m}$ CMOS process.

  • PDF