• Title/Summary/Keyword: Reference method

Search Result 6,845, Processing Time 0.036 seconds

New Method of Volume Measurement for Reference Weights of a Pressure Balance Using a Gas Pycnometer (기체용적계를 이용한 분동식 압력계용 기준분동의 새로운 부피측정 방법)

  • Lee, Yong Jae;Lee, Woo Gab;Mohammed, Mohammed Abdurahman;Park, Yon-Kyu;Oh, Chae Yoon
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.231-237
    • /
    • 2013
  • New method of volume measurement for reference weights of a pressure balance using a gas pycnometer is proposed. The result of volume measurement of proposed method shows the uncertainties of approximately 0.2% at the level of confidence of 95% for reference weights in the ranges of 1 kg, 2 kg, and 5 kg. This measuring system consists of a sample chamber, an expansion chamber, a precision pressure gage, a precison thermometer, a vacuum pump, and helium as a medium gas. The measurement principle of this proposed method is based on Boyle's law. This method will contribute a reliability of the volume measurements of reference weights for a pressure balance to the national measurement standard.

Mass Balance Method for Purity Assessment of Organic Reference Materials: for Thermolabile Materials with LC-UV Method

  • Lee, Joonhee;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3275-3279
    • /
    • 2014
  • A mass balance method for purity assessment of thermolabile organic reference materials was established by combining several techniques, including liquid chromatography with UV/VIS detector (LC-UV), Karl-Fischer (K-F) Coulometry, and thermal gravimetric analysis (TGA). This method was applied to three fluoroquinolones like enrofloxacin, norfloxacin and ciprofloxacin. LC-UV was used to analyze structurally related organic impurities based on UV/VIS absorbance spectra obtained in combination with LC separation. For all three organic reference materials, the UV/VIS spectra of the separated impurities were similar to that of the major component of the corresponding materials. This indicates that the impurities are structurally related to the respective reference material sharing common chromophores. Impurities could be quantified by comparing their absorbances at the wavelength of maximum absorbance (${\lambda}_{max}$). The water contents of the reference materials were measured by K-F Coulometry by an oven-drying method. The total inorganic impurities contents were assayed from ash residues in TGA analysis with using air as a reagent gas. The final purities estimated from results of those analytical techniques were assigned as ($99.91{\pm}0.06$), ($97.09{\pm}0.17$) and ($91.85{\pm}0.17$)% (kg/kg) for enrofloxacin, norfloxacin and ciprofloxacin, respectively. The assigned final purities would be applied to the reference materials which will be used as calibrators for the certification of those compounds in matrix CRMs as starting points for the traceability of their certified values to SI units.

Improvement of Inter prediction by using Homography Reference Picture (Homography 참조 픽처를 사용한 화면 간 예측 효율 향상 방법)

  • Kim, Tae Hyun;Park, Gwang Hoon
    • Journal of Broadcast Engineering
    • /
    • v.22 no.3
    • /
    • pp.397-400
    • /
    • 2017
  • Recently, a lot of images containing various global movements have been generated by the activation of the photographic equipment such as the drone and the action cam. In this case, when the motion such as rotation, scaling is generated, it is difficult to expect a high coding efficiency in the conventional inter-picture prediction method using the 2D motion vector. In this paper, we propose a video coding method that reflects global motion through homography reference pictures. As a proposed method, there are 1) a method of generating a new reference picture by grasping a global motion relation between a current picture and a reference picture by homography, and 2) a method of utilizing a homography reference picture for inter-picture prediction. The experiment was applied to the HEVC reference software HM 14.0, and the experimental result showed an increase in encoding efficiency of 6.6% based on RA. Especially, the results using the videos with rotational motion have a maximum coding efficiency of 32.6%, which is expected to show high efficiency in video, which is often represented by complex global motion such as drones.

Development of Assessment Methodology for Locally Corroded Pipe Using Reference Stress Concept (참조응력개념을 이용한 국부감육배관 평가법 개발)

  • Lim, Hwan;Shim, Do-Jun;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1200-1209
    • /
    • 2003
  • In this paper, a unified methodology based on the local stress concept to estimate residual strength of locally thinned pipes. An underlying idea of the proposed methodology is that the local stress in the minimum section for locally thinned pipe is related to the reference stress, popularly used in creep problems. Then the problem remains how to define the reference stress, that is the reference load. Extensive three-dimensional finite element (FE) analyses were performed to simulate full-scale pipe tests conducted for various shapes of wall thinned area under internal pressure and bending moment. Based on these FE results, the reference load is proposed, which is independent of materials. A natural outcome of this method is the maximum load capacity. By comparing with existing test results, it is shown that the reference stress is related to the fracture stress, which in turn can be posed as the fracture criterion of locally thinned pipes. The proposed method is powerful as it can be easily generalised to more complex problems, such as pipe bends and tee-joints.

Design of a 2.5 Gbps CMOS optical transmitter with 10:1 serializer using clock generation method (Reference clock 생성기를 이용한 10:1 데이터 변환 2.5 Gbps 광 송신기 설계)

  • Kang, Hyung-Won;Kim, Kyung-Min;Choi, Young-Wan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.159-165
    • /
    • 2005
  • The proposed optical transmitter is composed of FF(flip flop) , PLL (phase locked loop), reference clock generator, serializer and LD driver 10x250 Mb/s data arrays are translated to the 2.5 Gb/s data signal by serializer. In this case, 1 data bus is allocated usually as a reference clock for synchronization. In this proposed optical transmitter, 125 MHz reference clock is generated from 10x250 Mb/s data arrays by reference clock generator. From this method. absent of reference clock bus is available and more data transmission become possible. To achieve high speed operation, the serializer circuit is designed as two stacks. For 10:1 serialization, 10 clocks that have 1/10 lambda differences is essential, so the VCO (voltage controlled oscillator) composed of 10 delay buffers is designed. PLL is for runing at 250 MHz, and dual PFD(phase frequency detector) is adopted for fast locking time. The optical transmitter is designed by using 0.35 um CMOS technology.

  • PDF

Non-Reference P Frame Coding for Low-Delay Encoding in Internet Video Coding (IVC의 저지연 부호화 모드를 위한 비참조 P 프레임의 부호화 기법)

  • Kim, Dong-Hyun;Kim, Jin-Soo;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.19 no.2
    • /
    • pp.250-256
    • /
    • 2014
  • Non-reference P frame coding is used to enhance coding efficiency in low-delay encoding configuration of Internet Video Coding (IVC), which is being standardized as a royalty-free video codec in MPEG. The existing method of non-reference P frame coding which was adopted in the reference Test Model of IVC (ITM) 4.0 adaptively applies a non-reference P frame with a fixed coding structure based on the magnitude of motion vectors (MVs), however, which unexpectedly degrades the coding efficiency for some sequences. In this paper, the existing non-reference P frame coding is improved by changing non-reference P frame coding structure and applying a new adaptive method using the ratio of the amount of generated bits of non-reference frames to that of reference frames as well as MVs. Experimental results show that the proposed non-reference P frame coding gives 6.6% BD-rate bit saving in average over ITM 7.0.

Ground Plane Detection Method using monocular color camera

  • Paik, Il-Hyun;Oh, Jae-Hong;Kang, Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.588-591
    • /
    • 2004
  • In this paper, we propose a ground plane detection algorithm, using a new image processing method (IPD). To extract the ground plane from the color image acquired by monocular camera, we use a new identical pixel detection method (IPD) and an edge detection method. This IPD method decides whether the pixel is identical with the ground plane pixel or not. The IPD method needs the reference area and its performance depends on the reference area size. So we propose the reference area auto-expanding algorithm in accordance with situation. And we evaluated the proposed algorithm by the experiments in the various environments. From the experiments results, we know that the proposed algorithm is efficient in the real indoor environment.

  • PDF

The Buck DC-DC Converter with Non-Linear Instantaneous Following PWM Control Method (비선형 순시추종형 PWM 제어기법을 적용한 강압형 DC-DC 컨버터)

  • Kim Sang-Don;Ra Byung-Hun;Lee Hyun-Woo;Kim Kwang-Tae
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.470-475
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of do-dc converter. In this control method, the duty ratio of a switch is exactly equal In or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM

  • PDF

Parameter Optimization using Eevolutionary Programming in Voltage Reference Circuit Design (진화 연산을 이용한 기준 전압 회로의 파라미터 최적화)

  • 남동경;박래정;서윤덕;박철훈;김범섭
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.8
    • /
    • pp.64-70
    • /
    • 1997
  • This paper presents a parameter optimization method using evolutionary programming in voltage reference circuit because the designer must select appropriate parameter values of the circuit taking into consideration both powr voltage and temperature variation. In this paper, evolutionary programming is suggested as an approach for finding good parameters with which the reference voltage variation is small with respect to temperature variation. Simulation results. Simulation results show that this method is effective in circuit design.

  • PDF

The Effect of Internal Tetramethylsilane Reference in Determination of $^{13}C$ NMR Chemical Shifts ($^{13}C$ NMR 화학 Shift 측정에 미치는 TMS의 거동)

  • Youm, Jeong-Rok
    • YAKHAK HOEJI
    • /
    • v.33 no.3
    • /
    • pp.203-205
    • /
    • 1989
  • A method is presented for calculating the $^{13}C$ chemical shifts produced in liquid solution by referenced relative to RF frequency. The method is useful to get the real variations of chemical shifts in magnetic field by eliminating the affects of the variation of a reference substance.

  • PDF