• Title/Summary/Keyword: Reference gas

Search Result 471, Processing Time 0.025 seconds

A Study on the Analysis of Risk Factors for Hydrogen Fuel Stations Based on Quantitative Risk Assessment (정량적 위험성평가 기반 수소충전소 위험요소 분석 연구)

  • Lee, Jae Yong;Lee, Jieun;Song, Hyoungwoon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.70-76
    • /
    • 2020
  • In this study, we suggested the direction to lower the risk by analyzing the risk factors for each process for the hydrogen refueling station to be installed in Chungju. HyRAM, one of the quantitative risk assessment tools for hydrogen gas, was used to analyze the hazards. By evaluating the frequency of accidents and consequences for each process, the most dangerous processes and accident factors were presented, and the risk mitigation factors were synthesized. Hydrogen refueling stations are currently in the global infrastructure expansion period, and the lack of accident data could be an alternative to this risk assessment and is expected to be used as a reference for the future expansion of hydrogen refueling stations.

A Study on Development of Mobile LNG Yard Tractor Refueling Standards (이동식 LNG 야드트랙터 충전 기준 개발 연구)

  • Ryou, Young-don;Yu, Chul-hee;Koo, Bon-deuk;Lee, Dong-won
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.59-64
    • /
    • 2018
  • As part of measures to reduce fine dust, the government is promoting a project to convert the fuel of Yard Tractors(YT, tractors operated at ports), from diesel to LNG (Liquefied Natural Gas). While a port having a small number of yard tractors, it is not proper to construct a stationary LNG fueling station and supply LNG to YT due to a problem of BOG (Boil off gas) generation. Therefore, it is necessary to make a regulation and a standard on mobile LNG YT refueling station installation and inspection as an alternative. In this study, we have investigated domestic and foreign mobile LNG refueling cases and refueling standards, including the USA and Europe. In addition, we have suggested the risk reduction method according to the cause after investigation of the cause of LNG accidents. And last, based on the proposed risk reduction measures, we have proposed an amendment to the Regulation of the Urban Gas Business Law in Korea. The proposed mobile LNG YT refueling amendment of the Regulation includes ; maintenance of the safety distance from the protection facility, installation of an interlock device to prevent refueling in places other than the authorized place, installation of the identification system through biometrics, separation of the tank lorry and tow vehicle before refueling, checking the wheel fixed status of tank lorry before refueling, construction of the impounding area, safety measures before, during and after refueling, etc. The safety standards proposed in this study could be used as a reference in establishing standards for mobile LNG vehicle refueling in the near future.

A Study on LNG Quality Analysis using a Raman Analyzer (라만분석기를 이용한 LNG 품질 분석 실증 연구)

  • Kang-Jin Lee;Woo-Sung Ju;Yoo-Jin Go;Yong-Gi Mo;Seung-Ho Lee;Yoeung-Chul Kim
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.70-79
    • /
    • 2024
  • Raman analyzer is an analytical technique that utilizes the "Raman effect", which occurs when light is scattered by the inherent vibrations of molecules. It is used for molecular identification and composition analysis. In the natural gas industry, it is widely used in bunkering and tank lorry fields in addition to LNG export and import terminals. In this study, a LNG-specific Raman analyzer was installed and operated under actual field conditions to analyze the composition and principal properties (calorific value, reference density, etc.) of LNG. The measured LNG composition and calorific value were compared with those obtained by conventional gas chromatograph that are currently in operation and validated. The test results showed that the Raman analyzer provided rapid and stable measurements of LNG composition and calorific value. When comparing the calorific value, which serves as the basis for LNG transactions, with the results from conventional gas chromatograph, the Raman analyzer met the acceptable error criteria. Furthermore, the measurement results obtained in this study satisfied the accuracy criteria of relevant international standards (ASTM D7940-14) and demonstrated similar outcomes compared to large-scale international demonstration cases.

Effects of Temperature and Humidity on NDIR CO2 Gas Sensor (비분산 적외선 이산화탄소 가스센서 특성의 온·습도 영향)

  • Kim, JinHo;Yi, SeungHwan
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.179-185
    • /
    • 2017
  • This article describes the characteristics of nondispersive infrared carbon dioxide gas sensor according to the temperatures and humidifies. In this researches, a thermopile sensor that included application-specific integrated circuit (ASIC) was used and the White-cell structure was implemented as an optical waveguide. The developed sensor modules were installed in gas chamber and then the temperature of gas chamber has been increased from 283 K to 313 K with 10K temperature step. In order to analyze the effects of humidity levels, the relative humidity levels were changed from 30 to 80%R.H. with small humidifier. Then, the characteristics of sensor modules were acquired with the increment of carbon dioxide concentrations from 0 to 2,000 ppm. When the initial voltages of sensors were compared before and after humidifying the chamber at constant temperature, the decrements of the output voltages of sensors are like these: 9mV (reference infrared sensor), 41 mV (carbon dioxide sensor), 2 mV (temperature sensor). With the increment of ambient temperature, the averaged output voltage of carbon dioxide sensor was increased 19 mV, however, when the humidity level was increased, it was decreased 14mV. Based upon the experimental results, the humidity effect could be alleviated by the increment of temperature, so the effects of humidity and temperature could be only compensated by the ambient temperature itself. The estimated carbon dioxide concentrations showed 10% large errors below 200 ppm, however, the errors of the estimations of carbon dioxide concentrations were less than ${\pm}5%$ from 400 to 2,000 ppm.

Flavor Components of the Fruit Peel and Leaf Oil from Zanthoxylum piperitum DC (초피(Zanthoxylum piperitum DC)의 과피와 잎의 방향성분)

  • Kim, Jung-Han;Lee, Kyung-Seok;Oh, Won-Taek;Kim, Kyoung-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.562-568
    • /
    • 1989
  • The essential oils from ripe fruit peel and leaf of Zanthoxylum piperitum DC were extracted by gas co-distillation method and analyzed by gas chromatography/mass spectrometry (GC/ MS) and retention index matching. The experimental results revealed the presence of over 100 volatile components. Major components were 1,8-cineol (25.47%), limonene (11.91%), geranyl acetate (9.01%), myrcene (6.15%) in fruit peel and citronellal (23.11%), 1,8-cineol (18.38%), citronellol (6.04%) in leaf. Among the components identified were the following; in fruit peel, ${\alpha}-pinene$ and 13 hydrocarbons, linalool and 8 alcohols, citronellal and 3 aldehydes, carvone and 2 kotones, methyl salicylate and 7 esters, and 1,8-cineol and oxides, and in leaf, ${\alpha}-pinene$ and 7 hydrocarbons, linalool and 7 alcohols, citronellyl acetate and 5 esters, citronellal and 1 aldehyde, carvone, and 1,8-cineol and 1 oxide.

  • PDF

Measurement of combustion gas temperature using laser-induced breakdown spectroscopy (레이저 유도 플라즈마 분광분석법을 이용한 연소 가스 온도 측정 기술)

  • Lee, Seok Hwan;Kim, Yong-Gyoo;Kang, Woong;Joung, Wukchul;Lee, Joo Hyun;Kim, Sunghun;Yang, Inyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.285-289
    • /
    • 2017
  • Laser-induced breakdown spesctroscopy (LIBS) is a technique that complements the disadvantages of conventional laser-based combustion diagnosis techniques such as weak signal strength, complex equipment configuration, and low accuracy. In this study, basic research was carried out to measure the combustion gas temperature of scramjet engines using LIBS. Spray flames were generated from Jet A-1 fuel used in scramjet engines and gas temperatures were measured at the top of the flames with a calibrated thermocouple. The LIBS signals were acquired at the same points as the temperature measurement positions of the thermocouple. The LIBS spectra were analyzed to obtained a calibration curve between the LIBS signal and the reference temperature measured at the thermocouple. Therefore, it was confirmed that the combustion gas temperature can be measured in-situ using LIBS.

  • PDF

Effect of Heat Transfer and Phase Change of Coolant on the Performance of Mixed-gas Ejection System (냉각제의 분사조건 및 상변화가 혼합가스 사출시스템의 성능에 미치는 영향)

  • Kim, Hyun Muk;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.84-93
    • /
    • 2018
  • Three-dimensional (3D) numerical simulations have been carried out to study how coolant injection conditions influence the cooling efficiency and projectile ejection performance in a mixture-gas ejection system (or gas-steam launch system). The 3D single-phase computational model was verified using a 1D model constructed with reference to the previous research and then a two-phase flow computation simulating coolant injection on to hot gas was performed using a DPM (Discrete Phase Model). As a result of varying the coolant flow rate and number of injection holes, cooling efficiency was improved when the number of injection holes were increased. In addition, the change of the coalescence frequency and spatial distribution of coolant droplets caused by the injection condition variation resulted in a change of the droplet diameter, affecting the evaporation rate of coolant. The evaporation was found to be a critical factor in the design optimization of the ejection system by suppressing the pressure drop while the temperature decreases inside the breech.

The Effectiveness of Blood β-ketone Testing in Patients with Diabetic Ketosis: A Systematic Review & Meta-analysis (당뇨환자에서 자가관리형 베타케톤검사의 유효성: 체계적 문헌 고찰 및 메타분석)

  • Mo, Jin A;Jang, Sunyoung;Bang, Hee Young
    • Korean Journal of Health Education and Promotion
    • /
    • v.31 no.4
    • /
    • pp.1-10
    • /
    • 2014
  • Objectives: The effectiveness of Blood ${\beta}$-ketone testing by using self-monitoring strip on diabetic patients. Methods: Clinical effectiveness of blood ${\beta}$-ketone testing was assessed through correlation with reference test that measured blood ${\beta}$-ketone value through gas chromatography or enzyme method, diagnostic accuracy, time taken for the test and time taken for confirmative diagnosis of diabetic ketosis by selecting literatures on researches that conducted this test on ketosis(suspected) patients or diabetic ketosis(suspected) patients. Each of the stages from literature search to application of selection standards and extraction of data were carried out independently by the Subcommittee along with 2 researchers. Results: 7 reports were selected. ${\beta}$-ketone testing displayed high level of correlation in the range of r=0.92~0.99 with test using enzyme method as the reference standard. Regarding the diagnostic accuracy, sensitivity of 0.82, specificity of 0.74. The time taken for the test was 30seconds for the index test, which is shorter than reference standard test. Conclusion: Blood ${\beta}$-ketone testing was assessed to be a safe and effective test to monitor ketosis and assess the level of risk of ketosis by measuring the blood ${\beta}$-ketone on ketosis patients and diabetic ketosis patients since it has high level of correlation with reference test and short period of testing.

A Study on the Performance Measuring Methods and Standard for the Technical Package in Zero Energy Building (제로에너지빌딩의 기술 패키지 구성을 위한 성능 기준 및 성능 측정 방법에 관한 연구)

  • Sung, Uk-Joo;Rim, Min-Yeop;Kim, Seok-Hyun;Cho, Soo
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.543-556
    • /
    • 2018
  • Zero energy building was attended for energy consumption minimization by the energy saving technology about building heating and cooling energy consumption and the renewable energy production facility. So the government has supported the zero energy building supply for decreasing green gas emissions. The study about inventory of zero energy building has many proceeding. That inventory need the information of material and equipment. So information of material and equipment about zero energy building must be included for the zero energy building realization. Actually the database of zero energy building inventory construction through the inventory established studies has difficult because the database need many information. In this study, author proposed the test methods and performance reference for upload at inventory. It was constructed to material - module - package. Also the author analyzed the construction of the technical package for zero energy building. The author separated performance category to the energy performance for energy analysis and other performance for confirmed the durability, stability and etc. This performance category proposed the table. The test methods of material and equipment in the passive package and active package proposed to the international standard and korea standard basically korea standard. Also the performance reference was proposed to korea legal standard and various standard by this study results. And the authors proposed the table of performance value, test methods, performance reference. By result of this study, the test methods and performance reference will be used the basic data for inventory of zero energy building.

Calibration of High Pressure Vibrating Tube Densimeter (고압 밀도계의 보정에 대한 연구)

  • Kim Hwayong;Oh Kyoung Shil;Bae Won
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.49-54
    • /
    • 2005
  • This work was to calibrate Anton Paar 512P vibrating tube densimeter which is a special type for density measurement under high pressure (up to 70 MPa) and temperature (up to 420 K) and checked the validity of the new apparatus. Calibration was peformed with water, nitrogen and water, vacuum as reference fluids. Temperature is measured from 313.15 K and 353.15 K at 10 K intervals, and pressure is measured up to 30 MPa at 5 MPa intervals, respectively. To check the validity of new apparatus and the calibration method we compared the values obtained by measuring density of carbon dioxide with those given by NIST Thermophysical Properties of Pure Fluids Database. The average deviations between the NIST and the experimental data were $0.3\%$ with water and nitrogen as reference fluids.

  • PDF