Local Validation of MODIS Global Leaf Area Index (LAI) Product over Temperate Forest

  • Kim, Sun-Hwa;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • MODIS LAI product has been one of key variable for analyzing the quantitative aspects of terrestrial ecology at global scale. This study was designed to validate MODIS global LAI product for regional application. To examine the quality of MODIS LAI data, we developed a reference LAI surface that was derived by relating the ground LAI measurements to Landsat ETM+ reflectance. The study area, the Kwangneung Experiment Forest in Korea, covers mixed deciduous and coniferous species of temperate forest. Ground measurements of LAI were conducted at 30 sample plots by using a photo-optical instrument during the growing season of 2002. Ground measured LAI data were then related to the ETM+ reflectance to produce a continuous map of LAI surface over the study area. From the comparison between the MODIS LAI and the reference LAI, it was found that the MODIS LAI values were slightly higher at the forestland. Considering the limitations of producing the reference LAI surface and the uncertainty of the input variable for the MODIS LAI algorithm, such small discrepancy mal not be significant.

Computer Literacy Skills as a Determinant of Electronic Reference Sources Utilization among Selected Secondary School Students in Ado-Odo Ota Local Government, Ogun State, Nigeria

  • Elizabeth Bukunola Lateef;Opene Sunday Ozonuwe;Adesanmi Mathew Farukuoye
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.14 no.2
    • /
    • pp.81-97
    • /
    • 2024
  • The study investigated computer literacy skills as a determinant of electronic reference sources utilization among selected secondary school students in Ado-Odo Ota Local Government, Ogun State, Nigeria. Four specific objectives with conforming research questions guided the study. Descriptive survey research design was adopted for the study. The population of the study comprises of SSS3 students of the three selected Community Secondary Schools in Ado Odo Ota. A sample size of 150 was used for the study. The instrument for data collection was a self-developed structured questionnaire. Data collected was analyzed using frequency and percentages. Findings of the study revealed that majority of secondary school students were not aware of the availability of electronic reference sources. It also revealed that the level of their computer literacy skills was below average. Majority of them have never used computer before and the few of them that have used computer before used it in their homes, their friend's homes or in the cyber café. It was found that lack of formal training on the use of electronic reference sources, lack of access to computer, lack of awareness of availability of electronic reference sources, lack of funds for internet subscriptions, over dependency on printed reference sources and lack of motivation to use electronic reference sources were the major hindrances to the use of electronic reference sources among secondary school students. It was recommended that the school librarians and teachers should play a role in creating awareness among secondary school students about the availability of online/ electronic reference sources among others.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Evidence-based health literacy improvements: trends on health literacy studies in Korea (근거 중심의 헬스 리터러시 증진 방안: 학술지 연구 동향을 중심으로)

  • Kang, Soo Jin;Lee, Mi Sook
    • Korean Journal of Health Education and Promotion
    • /
    • v.32 no.4
    • /
    • pp.93-108
    • /
    • 2015
  • Objectives: The purpose of this study was to investigate the current state of health literacy research and to explore the directions of improvement health literacy in Korea. Methods: A review of literature was conducted via an electronic database and citation tracking reference. A total of 173 articles were identified, where and then 41 articles were selected for review that met the inclusion criteria. Two authors independently reviewed the articles using the matrix table and together examined together the three aspects of the studies: research methods, health literacy instrument, and results. Results: Most of the articles were descriptive-correlation studies, but there were one intervention study and six methodology studies that were developing health literacy measures and instrument related items and etc. More troubling sufficient samples and sampling methods were lacking at the population level. The validity of the used health literacy instruments was not sufficient reported. Conclusions: Health literacy instruments need to be validated in various population and contexts. Additionally, effective strategies to improve health literacy included teach-back, pictogram, and decision aids need to be tested in Korean health care system.

Turbine discharge measurement case study using ASFM system (ASFM을 이용한 수차유량의 측정)

  • Kim, Eung-Tae;Jeong, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.49-52
    • /
    • 2006
  • should be in English, A make out an economical, reliable and easy to adoptable instrument in turbine discharge measurement was restricted from lots of it's foundational condition. Not with standing the brilliant progress in new technology of these day, useful instrument for flow measurement in turbine is still ongoing. Nowaday, the increasing importance of renewable energy makes it more important that the measuring turbine efficiency as a decision making index of old turbines' replacement. In Turbine performance diagnosis, Kwater(Korea Water Corporation) got an enough ability and decent reputation for who has invested lots of time and effort for buildup and development. In Korea as a public corporation who should take a crucial roll in Turbine business, Kwater has introduced some developed new technology for other domestic concerned one. With this writing, I'd like to introduce ASFM system as a newly developed instrument that can cope with lots restriction in discharge measurement in turbine. Kwater adopted the system in 2005, and performed 2 times of trial test. The test result was good enough to use the system as a reference test method.

  • PDF

Solar Radiation Measurement and Data Quality Management (태양자원 측정 및 데이터 품질관리)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.63.2-63.2
    • /
    • 2010
  • Solar radiation data are used in several forms and for a variety of purposes. The most detailed information we have is beam and diffuse solar radiation on a horizontal surface, by hours, which is useful in simulations of solar processes. Daily data are more often available and monthly total solar radiation on horizontal surface can be used in some process design methods. However, as performance is generally not linear with solar radiation, the use of average may lead to serious errors if non-linearities ara not taken into account. It is also possible to reduce radiation data to more manageable forms by statistical methods. The control of the quality of most measurements is relegated to the control of the measuring instruments and measuring processes themselves. An accurate measurement will usually result from the use of a high-quality instrument that has been accurately calibrated and is properly used by a qualified individual.

  • PDF

Temperature Measurement of Photovoltaic Modules Using Non-Contact Infrared System

  • Jovanovic, Ugljesa;Mancic, Dragan;Jovanovic, Igor;Petrusic, Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.904-910
    • /
    • 2017
  • This paper presents temperature measurement of solar photovoltaic modules using the custom-made system composed of an infrared temperature sensor and a microcontroller. The obtained measurement results are processed, displayed and stored on a PC using the custom-made virtual instrument. The proposed system overcomes some of the problems related to the contact sensor application, and at the same time offers accurate readings and better flexibility. The proposed system is especially suitable for applications where the cost is a limiting factor in the choice of measuring system. The conducted analysis and the obtained results have shown an excellent accuracy of the proposed system in comparison to a high quality thermal imaging camera used as the reference instrument.

A Study on the Development of Measuring System for Extra Long Roller Using Non-contact Sensor (비접촉식 센서를 이용한 초장축 롤러 측정 장치 개발에 관한 연구)

  • Kim, Woong;Lee, Choon-Man;Lee, Mun-Jae;Park, Sung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.4
    • /
    • pp.33-39
    • /
    • 2010
  • Manufacturing accuracy of a precision instrument was essential to stability and efficiency of the product. Accordingly, geometrically accuracy management of precision instrument was very becoming the technique in order to design and manufacturing for machine. In this study, Measuring System is developed for extra long roller using non-contact sensor. Futhermore, It's studied by Geometric Tolerance. Exact roundness is obtained to Least Squares method from the reference circle of measured data. Measuring System is analyzed point of measurement and straightness of extra long roller is evaluated by FEM.

Design on SDS2 On-line Poison Concentration Monitoring in CANDU

  • Kim, Seog-Nam;Jung, Ho-Chang;Kim, Sung;Kim, Ji-Hyeon;Han, Sang-Joon
    • Nuclear Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.500-505
    • /
    • 1996
  • At the reference plant(Wolsong unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsong unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low.

  • PDF

STANDARDISATION OF NIR INSTRUMENTS, INFLUENCE OF THE CALIBRATION METHODS AND THE SIZE OF THE CLONING SET

  • Dardenne, Pierre;Cowe, Ian-A.;Berzaghi, Paolo;Flinn, Peter-C.;Lagerholm, Martin;Shenk, John-S.;Westerhaus, Mark-O.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1121-1121
    • /
    • 2001
  • A previous study (Berzaghi et al., 2001) evaluated the performance of 3 calibration methods, modified partial least squares (MPLS), local PLS (LOCAL) and artificial neural networks (ANN) on the prediction of the chemical composition of forages, using a large NIR database. The study used forage samples (n=25,977) from Australia, Europe (Belgium, Germany, Italy and Sweden) and North America (Canada and U.S.A) with reference values for moisture, crude protein and neutral detergent fibre content. The spectra of the samples were collected using 10 different Foss NIR Systems instruments, only some of which had been standardized to one master instrument. The aim of the present study was to evaluate the behaviour of these different calibration methods when predicting the same samples measured on different instruments. Twenty-two sealed samples of different kind of forages were measured in duplicate on seven instruments (one master and six slaves). Three sets of near infrared spectra (1100 to 2500nm) were created. The first set consisted of the spectra in their original form (unstandardized); the second set was created using a single sample standardization (Clone1); the third was created using a multiple sample procedure (Clone6). WinISI software (Infrasoft International Inc., Port Mathilda, PA, USA) was used to perform both types of standardization, Clone1 is just a photometric offset between a “master” instrument and the “slave” instrument. Clone6 modifies both the X-axis through a wavelength adjustment and the Y-axis through a simple regression wavelength by wavelength. The Clone1 procedure used one sample spectrally close to the centre of the population. The six samples used in Clone 6 were selected to cover the range of spectral variation in the sample set. The remaining fifteen samples were used to evaluate the performances of the different models. The predicted values for dry matter, protein and neutral detergent fibre from the master Instrument were considered as “reference Y values” when computing the statistics RMSEP, SEPC, R, Bias, Slope, mean GH (global Mahalanobis distance) and mean NH (neighbourhood Mahalanobis distance) for the 6 slave instruments. From the results we conclude that i) all the calibration techniques gave satisfactory results after standardization. Without standardization the predicted data from the slaves would have required slope and bias correction to produce acceptable statistics. ii) Standardization reduced the errors for all calibration methods and parameters tested, reducing not only systematic biases but also random errors. iii) Standardization removed slope effects that were significantly different from 1.0 in most of the cases. iv) Clone1 and Clone6 gave similar results except for NDF where Clone6 gave better RMSEP values than Clone1. v) GH and NH were reduced by half even with very large data sets including unstandardized spectra.

  • PDF