• Title/Summary/Keyword: Reduction to bones

Search Result 74, Processing Time 0.023 seconds

A research on improving signal to noise ratio for magnetic resonance imaging through increasing filling factor inside surface coil (자기공명 검사시 코일 내 filling factor 증가를 통한 신호대 잡음비의 향상에 관한 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5299-5304
    • /
    • 2012
  • MRI signals are significantly reduced by the magnetic field inhomogenity result from human body itself being consisted of various materials like air, fat, muscle, bone and blood vessels. In this study we used silicon which is tissue equivalent to compensate wound body shapes. Objects were eight adults who do not have any special symptoms. Feet were scanned because of their complicated structures and consequently signal reduction occurs a lot. Thirty images were acquired from the middle of arcus pedis longitudinalis including five distal phalanges parallel to the line connecting metatarsal bone and phalanges. SNR data from bones and soft tissues were compared before and after sticking silion between toes and paired t test was performed. It was came out that SNR data from bone and soft tissue were both significantly higher after applying silicon on both T1 and T2 weighted images and it was statistically meaningful having positive corelation. As a result, this study dramatically increases SNR without affecting object by increasing the object volume inside the surface coil.

The Effect of Combined Estrogen/Calcium Therapy on Bone Metabolism in Ovariectomized Rats -III. A Study on Skeletal Composition in Ovariectomized Rats- (에스트로겐/칼슘 혼합요법이 난소절제 쥐의 골대사에 미치는 영향 -III. 골격 구성성분에 미치는 영향-)

  • Lee, Kyung-Hwa;Lee, Sung-Sug;Choi, In-Seon;Oh, Seung-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.2
    • /
    • pp.334-343
    • /
    • 1997
  • This study was performed to elucidate the effects of dietary calcium-salt, estrogen-treatment, and estrogen/calcium treatment on bone metabolism. Ovariectomized rats were used as an animal model. Female Sprague-Dawley rats with a body weight of $250{\sim}280g$ underwent ovariectomy or sham-operation. The ovariectomized rats were divided into 9 different experimental groups including saline-treated group, estrogen-treated group, high calcium salt-treated group, and estrogen/calcium treated groups, and fed the experimental diet for 6 weeks. The mineral content, weight, length, strength and density in femur and scapula of the animals were determined. The results of the experiment are as follows: there were no difference in weight of wet bone, density, length, strength and content of ash in right femur between ovariectomized rat and sham-operation. When the weight of bones was expressed as bone gram per body weight, it was significantly lower in ovariectomized rat than sham-operation. Estrogen and estrogen/calcium in ovariectomized rats resulted in increased weight of wet bone. Estrogen with its gradual reduction in ovariectomized rats showed the lowest values in strength, content of ash, content of calcium and content of phosphorus among the groups. There were no differences in weight of wet hone, density, content of ash, content of calcium and content of phosphorus in right scapula between ovariectomized rat and sham-operation. In addition skeletal composition was not changed by ovariectomy. Estrogen and estrogen/calcium in ovariectomized rats resulted in decreased skeletal composition however, estrogen with its gradual reduction did not caused the skeletal composition change. Moreover, the gradual reduction of estrogen had a preventive effect on bone loss when the treatment was combined with calcium intensification.

  • PDF

Application of Waste Resources for the Stabilization of Heavy Metals (Pb, Cu) in Firing Range Soils (폐자원을 이용한 사격장 토양내 중금속(Pb, Cu) 안정화 처리)

  • Lee, Keun-Young;Moon, Deok-Hyun;Kim, Kyoung-Woong;Cheong, Kyung-Hoon;Kim, Tae-Sung;Khim, Jee-Hyeong;Moon, Kyoung-Ran;Choi, Su-Bin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.71-76
    • /
    • 2011
  • In this study, a heavy metal stabilization treatment using waste resource stabilizing agents was utilized on army firing range soil contaminated with Pb and Cu. Both calcined oyster shells (COS; 5% w/w) and waste cow bone (WCB; 3% w/w) were applied for a wet-curing duration of 28 days. Following the stabilization treatment, the process efficiency was evaluated by various extraction methods for Pb and Cu. Neutral and weak acid extraction methods, such as water soluble extraction and SPLP, did not show positive results for heavy metal stabilization with very low leachability. On the other hand, TCLP and 0.1 N HCl extraction showed that the stabilizing agents significantly reduced the amount of the heavy metals leached from the soil, which strongly supports that the treatment efficiency is positively evaluated in acidic leaching conditions. Specifically, in the 0.1 N HCl extraction, the reduction efficiencies of Pb and Cu leaching were 99.9% and 83.9%, respectively. From the sequential extraction results, a difference between Pb and Cu stabilization was observed, which supports that Pb stabilization is more effective due to the formation of insoluble Pb complexes. This study demonstrates that the application of waste resources for the stabilization of heavy metals is feasible.

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF