• 제목/요약/키워드: Reduction of exposure to radiation

검색결과 227건 처리시간 0.025초

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

Dose Reduction Factors for High-Exposure Tasks at Korean Pressurized Water Reactors

  • Changju Song;Tae Young Kong;Seongjun Kim;Jinho Son;Jiung Kim;Jaeok Park;Hee Geun Kim;Yongkwon Kim;Hyungkwon Jung
    • 방사선산업학회지
    • /
    • 제18권1호
    • /
    • pp.23-33
    • /
    • 2024
  • This study was conducted to analyze the characteristics of three high-exposure tasks performed by radiation workers in Korean pressurized water reactors (PWRs) and to identify factors that reduce their exposure during work. Three high-exposure tasks were selected based on a previous study. In this previous study, nozzle dam installation and removal, eddy current testing, and manway opening and closing were determined as high-exposure tasks through normalization (radiation dose per unit time). Based on the analysis of the characteristics of the high-exposure tasks in this study, the high-exposure tasks were steam generator-related tasks performed inside and outside the water chamber. This study analyzed the reduction factors for high-exposure tasks and suggested improvements in terms of time, distance, and shielding. The use of the characteristics of high-exposure tasks and their dose reduction factors enables Korean PWRs to optimize radiation protection for workers who receive relatively high doses.

영.유아의 배뇨성 방광-요도 조영술 및 방사선 공기 주입 정복술시 피폭선량 경감을 위한 fluorograb의 유용성 (The Efficacy of Fluorograb for Paediatric Patients Dose Reduction during Pneumatic Reduction and Voiding Cystourethrography(VCUG))

  • 김상태;최지원
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.385-390
    • /
    • 2009
  • 공기주입 정복술(pneumatic reduction) 및 방사선 배뇨성 방광요도 조영술(Voiding Cystourethrography: 이하 VCUG)는 일반적으로 영,유아에게서 행해지는데 이들 검사는 투시촬영과 spot 촬영으로 이루어지며 이때 투시촬영으로 인한 방사선 피폭은 불가피한 것이나 spot 촬영으로 인한 피폭은 투시 화면상의 관심영상을 capture하는 기능인 fluorograb을 이용하여 제거할 수 있다. fluorograb은 spot영상과 비슷한 진단가치를 지니고 있으며 최근 사용되고 있는 대부분의 투시촬영장비에서 지원되는 기능이지만 다수의 의사 및 방사선사는 이 기능을 인지하지 못하고 있거나 인지하고는 있으나 습관적으로 spot 촬영을 행하고 있는 실정이다. 이는 방사선에 매우 민감한 연령대에 속한 영.유아에서 적게는 10장 미만에서 많게는 20장 이상을 spot 촬영하게 되는 공기주입 정복술 및 VCUG에서 그 영향이 적지 않다 하겠다. 따라서 공기주입 정복술 및 VCUG 시행시 spot 촬영으로 인한 영.유아의 피폭을 줄이기 위한 방법으로 spot 촬영을 대신한 fluorograb을 제안하며 이로 인한 기존의 공기주입 정복술 및 VCUG 시행 시 영 유아의 피폭선량 경감 효과를 증명하고자 하였다. 공기주입 정복술 및 VCUG 의 진단에 fluorograb은 spot 촬영과 비슷한 수준의 정확도를 보이는 안전하고 유용한 방법이여 공기주입 정복술 및 VCUG 시행 시 spot 촬영을 대체할 수 있을 것으로 생각한다.

영아/유아의 공기 주입 정복술 및 방사선 배뇨성 방광요도 조영술시 피폭 선량 경감을 위한 FluroGrab의 유용성 (The Efficacy of Fluorograb for Paediatric Patients Dose Reduction during Pneumatic Reduction and Voiding Cystourethrography (VCUG))

  • 김상태;최지원;한태종
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1167-1172
    • /
    • 2009
  • 공기주입 정복술(pneumatic reduction) 및 방사선 배뇨성방광요도 조영술(Voiding Cystourethrography: 이하 VCUG)는 일반적으로 영,유아에게서 행해지는데 이들 검사는 투시 촬영과 spot 촬영으로 이루어지며 이때 투시촬영으로 인한 방사선 피폭은 불가피한 것이나 spot 촬영으로 인한 피폭은 투시 화면상의 관심영상을 capture하는 기능인 fluorograb을 이용하여 제거할 수 있다. fluorograb은 spot영상과 비슷한 진단가치를 지니고 있으며 최근 사용되고 있는 대부분의 투시촬영장비에서 지원되는 기능이지만 다수의 의사 및 방사선사는 이 기능을 인지하지 못하고 있거나 인지하고는 있으나 습관적으로 spot 촬영을 행하고 있는 실정이다. 이는 방사선에 매우 민감한 연령대에 속한 영.유아에서 적게는 10장 미만에서 많게는 20장 이상을 spot 촬영하게 되는 공기주입 정복술 및 VCUG에서 그 영향이 적지 않다 하겠다. 따라서 공기주입 정복술 및 VCUG 시행시 spot 촬영으로 인한 영.유아의 피폭을 제거하기 위한 방법으로 spot 촬영을 대신한 fluorograb을 제안하며 이로 인한 기존의 공기주입 정복술 및 VCUG 시행시 영.유아의 피폭선량 경감 효과를 증명하고자 하였다. 공기주입 정복술 및 VCUG 의 진단에 fluorograb은 spot 촬영과 비슷한 수준의 정확도를 보이는 안전하고 유용한 방법이여 공기주입 정복술 및 VCUG 시행시 spot 촬영을 대체할 수 있을 것으로 생각한다.

  • PDF

제조사별 다중 검출기 컴퓨터단층촬영 장비의 관전류 자동노출조절 기법의 방사선량 감소 평가 (Evaluation of Radiation Dose Reduction from the Automatic Exposure Control Technique in Different Manufactures Multi-Detector Computed Tomography)

  • 김영옥;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 추계학술대회
    • /
    • pp.563-571
    • /
    • 2011
  • The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

  • PDF

Radiation Exposure Reduction in APR1400

  • Bae, C.J.;Hwang, H.R.;Matteson, D.M.
    • Journal of Radiation Protection and Research
    • /
    • 제28권2호
    • /
    • pp.127-135
    • /
    • 2003
  • The primary contributors to the total occupational radiation exposure in operating nuclear power plants are operation and maintenance activities doting refueling outages. The Advanced Power Reactor 1400 (APR1400) includes a number of design improvements and plans to utilize advanced maintenance methods and robotics to minimize the annual collective dose. The major radiation exposure reduction features implemented in APR1400 are a permanent refueling pool seal, quick opening transfer tube blind flange, improved hydrogen peroxide injection at shutdown, improved permanent steam generator work platforms, and more effective temporary shielding. The estimated average annual occupational radiation exposure for APR1400 based on the reference plant experience and an engineering judgment is determined to be in the order of 0.4 man-Sv, which is well within the design goal of 1 man-Sv. The basis of this average annual occupational radiation exposure estimation is an eighteen (18) month fuel cycle with maintenance performed to steam generators and reactor coolant pumps during refueling outage. The outage duration is assumed to be 28 days. The outage work is to be performed on a 24 hour per day basis, seven (7) days a week with overlapping twelve (12) hour work shifts. The occupational radiation exposure for APR1400 is also determined by an alternate method which consists of estimating radiation exposures expected for the major activities during the refueling outage. The major outage activities that cause the majority of the total radiation exposure during refueling outage such as fuel handling, reactor coolant pump maintenance, steam generator inspection and maintenance, reactor vessel head area maintenance, decontamination, and ICI & instrumentation maintenance activities are evaluated at a task level. The calculated value using this method is in close agreement with the value of 0.4 man-Sv, that has been determined based on the experience aid engineering judgement. Therefore, with the As Low As Reasonably Achievable (ALARA) advanced design features incorporated in the design, APR1400 design is to meet its design goal with sufficient margin, that is, more than a factor of two (2), if operated on art eighteen (18) month fuel cycle.

C-arm을 이용한 EVAR(Endovascular Aneurysm Repair) 시술시 Lead Curtain 설치에 따른 Staff의 피폭선량 감소에 대한 연구 (The investigation of the exposure dose reduction of the Staff according to the Lead Curtain installation in EVAR(Endovascular Aneurysm Repair) surgical operation using C-arm)

  • 유인웅;정재연;이관섭
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.33-38
    • /
    • 2012
  • In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction.

  • PDF

Recent Trend of Occupational Exposure to Ionizing Radiation in Korea, 2015-2019

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.213-217
    • /
    • 2021
  • Background: Radiation exposure can occur as a result of occupational activities utilizing sources of radiation. The average level of occupational exposure is generally similar to the global average, but some workers receive more than this. In this study, the occupational exposure data for workers in Korea to check the recent trend of radiation exposure. Materials and Methods: The data collection and analysis are carried out by two separate periods based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) survey. One is the year 2003 to 2014 for a recent survey, and the other is 2015 to 2019. All available data were collected by annual reports from radiation dose registry organizations. Results and Discussion: The annual dose over the record level to the total workers did not change much compared with the total increasing number of workers in this period. The dose to the nuclear fuel cycle field has a tendency to decrease. It resulted from the efforts of radiation dose reduction with high technology introduced to this area. Also, it is important result that the radiation dose to the workers in radiography is remarkably reduced. Conclusion: The number of radiation workers and average doses were analyzed for occupational categories in Korea. It still needs cooperative efforts between the dose registry organizations for the efficient dose management of Korean radiation workers.

볼루스를 이용한 방사선영상검사 피폭선량저감 연구 (A Study of Radiation Dose Reduction using Bolus in Medical Radiation Exam)

  • 서정민
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.1001-1007
    • /
    • 2023
  • 방사선영상검사에서 발생하는 피폭선량에 대한 선량제한이 없으므로 방사선방호를 위한 정당화와 최적화가 반드시 필요하다. 조직등가물질 볼루스를 이용하여 방사선영상검사로 인한 피폭선량을 저감하면서 동시에 영상화질을 유지할 수 있는 범위를 확인하였다. 손 후전방향 프로젝션을 기준으로 50 kVp, 5 mAs, SID 100 cm, 8×10 inch 조건으로 볼루스를 0, 3, 5, 8, 10 mm 적용하여 손 부위 입사선량과 영상의 SNR을 확인하였다. 볼루스의 두께별 손 부위 입사선량(μGy)은 각각 125.41±0.288, 106.85±0.255, 104.97±0.221, 91.68±0.299, 90.94±0.106으로 나타나 볼루스의 사용여부와 그 두께에 따라 유의한 피폭선량 감소를 보였다. 영상의 SNR은 볼루스 각 두께에서 13.997, 13.906, 12.240, 12.538, 12.548로 나타나 큰 차이를 보이지 않았다. 방사선영상검사의 종류와 검사 부위에 따라 적절한 두께와 크기의 볼루스를 사용한다면 영상화질의 저하없이 유의한 피폭선량 저감효과를 볼 수 있음을 확인하였다.

A Study on Estimation of Radiation Exposure Dose During Dismantling of RCS Piping in Decommissioning Nuclear Power Plant

  • Lee, Taewoong;Jo, Seongmin;Park, Sunkyu;Kim, Nakjeom;Kim, Kichul;Park, Seongjun;Yoon, Changyeon
    • 방사성폐기물학회지
    • /
    • 제19권2호
    • /
    • pp.243-253
    • /
    • 2021
  • In the dismantling process of a reactor coolant system (RCS) piping, a radiation protection plan should be established to minimize the radiation exposure doses of dismantling workers. Hence, it is necessary to estimate the individual effective dose in the RCS piping dismantling process when decommissioning a nuclear power plant. In this study, the radiation exposure doses of the dismantling workers at different positions was estimated using the MicroShield dose assessment program based on the NUREG/CR-1595 report. The individual effective dose, which is the sum of the effective dose to each tissue considering the working time, was used to estimate the radiation exposure dose. The estimations of the simulation results for all RCS piping dismantling tasks satisfied the dose limits prescribed by the ICRP-60 report. In dismantling the RCS piping of the Kori-1 or Wolsong-1 units in South Korea, the estimation and reduction method for the radiation exposure dose, and the simulated results of this study can be used to implement the radiation safety for optimal dismantling by providing information on the radiation exposure doses of the dismantling workers.