Purpose: The nasal bone fracture is known as the most common facial fracture, with the postoperative results and the patient's satisfaction known to be lower than other facial fractures. The patient's satisfaction is firstly related to the accurate comprehension of the spatial relationship in the fractured nasal bone and secondly to the accurate reduction based on accurate comprehension. The aim of this study is to evaluate the objective usefulness of the three-dimensional (3D) imaging. Methods: The survey was conducted on 10 randomly selected cases of nasal bone fractures among the 46 cases with 3D computed tomography (CT) during the past one year. It was requested upon 4 plastic residents and 4 plastic surgeons to draw 3D aspect of fractured nasal bone directly on the printed photos of cadaver nasal bone, based on simple X-ray and two-dimensional (2D) CT. They were compared with the real fractured nasal bone aspects based on the 3D image and marked the difference in the 10-point scale of 0 to 10. Results: The average score of the 4 residents was 1.62 and that of the 4 surgeons was 4.47 out of 10 by simple X-ray. The average score of the 4 residents was 5.67 and that of the 4 surgeons was 7.25 out of 10 by 2D CT. Conclusion: It was surmised that the precise analysis and accurate comprehension of the spatial relationship of the fractured nasal bone using the 3D image, as based on the 2D CT images, can produce more favorable satisfaction levels in the patients.
목적 : 전위된 경골 과간 융기부 골절시 슬개골 하단을 통한 삽관 나사못 고정술의 효용성을 분석하고자 한다. 대상 및 방법 : 1998년 12월부터 2001년 5월까지 성인에서 전위된 경골 과간 융기부 골절을 관절경의 도움 하에 슬개골 하단을 통한 삽관 나사못 고정술을 시행하고 1년 이상 추시가 가능하였던 10예를 대상으로 임상적 및 방사선적 결과를 분석하였다. 결과 : 모든 예에서 골유합을 얻었으며 방사선적 골유합은 평균 9.2주였다 최종 추시시 전방 전위는 전방 stress 방사선상 평균 1.8 mm를 보였으며 KT-2000 arthrometer에서는 평균 1.1 mm였다. 신전 제한은 평균 4.1도를 보였다. 기능적 결과는 우수가 7예, 양호가 3예로 모두에서 만족할만한 결과를 보였다. 결론 : 성인에서 전위된 경골 과간 융기부 골절시 관절경적 수술 방법인 슬개골 하단을 통한 삽관 나사못 고정술은 슬개골 하단의 비관절면을 통하여 삽관 나사못을 고정함으로서 정확한 정복과 견고한 고정을 얻을 수 있었으며, 술 후 조기에 능동적 관절 운동을 허용할 수 있어 간편하면서도 유용한 수술방법이라 사료된다.
Purpose: The purpose of this setback genioplasty study is to develop a prediction method for the calculated osteotomy angle using horizontal and vertical changes as well as to evaluate the proportion of hard and soft tissue changes. Methods: Twelve patients who had received setback genioplasty with other maxillofacial surgery were examined. Three lateral cephalograms were taken just before surgery, immediately after surgery, and 3 months later surgery. A reference line was established to the reference point of the inner most point of the lingual symphysis cortex, incisor tip, and 2nd molar cusp tip. Measuring was conducted from pogonion (Pg), menton (Me), labrale inferius (Li), Mentolabial fold, soft tissue pogonion (Pg'), and soft tissue menton (Me') to the reference lines. Results: In setback genioplasty, the skeletal Pg moved posteriorly 5.07 mm. The ratios of soft tissue to hard tissue movement were 36% posteriorly and 62% inferiorly at Pg', 67% posteriorly and 104% inferiorly at Me', and 34% anteriorly and 164% posteriorly at Li. In reduction & setback genioplasty, skeletal Pg moved posteriorly 4.63 mm and skeletal Me moved superiorly 3.63 mm. The ratios of soft tissue to hard tissue movement were 76% posteriorly and 18% superiorly at Pg', 68% posteriorly and 42% superiorly at Me', and 44% anteriorly, 124% posteriorly at Li. The calculated mean slope angle, based on ${\Delta}H/{\Delta}V$ ratio, was 61.25 and the measured mean slope angle was 60.17. Thus, the calculated and measured slope angles have a similarity. Conclusion: In setback genioplasty, soft tissue moves posteriorly and inferiorly. In particular, at the Me' and Pg', the inferior movement of the soft tissue is greater than the posterior movement. Also, the predictable results (measured slope angle) after operation can be achieved by the calculated slope angle. Thus, the relationship of soft and hard tissue changes must be considered as the results are predictable.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제29권1호
/
pp.56-59
/
2003
구강악안면 영역에서의 외상에 의한 내악 동맥의 가성 동맥류는 극히 드문 병변으로 저자들은 서울 대학교 치과병원 구강악안면외과에서 1례를 치험하였다. 그 원인은 외상에 의한 하악 과두 골절, 관혈적 정복술시의 의원적 외상 또는 둘 다를 고려해 볼 수 있었으며 임상적으로 박동성 잡음,촉진 가능한 맥동이 있었고 술중 과다 출혈의 양상을 보였다. 병소는 혈관 조영술에 의해 확진되었으며, 색전술로 치료하였다. 가성 동맥류는 생명을 위협할 정도의 과다 출혈을 일으킬 수 있으므로 그 진단과 치료는 중요하다. 혈관 조영술은 임상적 증상에 대한 확실한 진단을 가능케 해 주며 이를 이용한 색전술은 관혈적 결찰법에 비해 장점을 가지므로 좋은 치료법이 될 수 있다.
Candida albicans는 면역력이 약화된 환자의 표재성에서 전신적 감염까지 다양한 부위에서 감염을 유발시킬 수 있는 기회 감염적 병원성 진균이다. C. albicans는 효모형에서 균사형으로 변환될 수 있으며 이 때 바이오필름을 형성할 수 있다. 바이오필름과 관련된 C. albicans의 감염은 일반적으로 통상적인 항진균제에 대해 내성을 보이므로 새로운 항진균제에 대한 개발이 절실하다. 대황(Rheum undulatum)은 전통적으로 한국과 중국에서 하제나 소염제로 사용되는 약용 식물이다. 본 연구의 목적은 R. undulatum이 캔디다증 환자로부터 분리한 C. albicans 바이오필름 형성 균주에 대한 바이오필름 형성 억제효과와 이에 대한 항진균 활성 기작을 알아보는 것이다. R. undulatum (0.098 mg/ml)은 12종의 바이오필름 형성 임상균주의 캔디다 바이오필름을 $49.4{\pm}6.0%$ 감소시켰고 C. albicans의 폴리스티렌 표면으로의 부착을 억제시켰다. CFDA, AM과 propidium iodide로 이중 염색한 결과 R. undulatum은 C. albicans의 세포막을 손상시켰으며 propidium iodide와 neutral red로 염색하여 공초점 레이저 현미경과 위상차 현미경으로 관찰한 결과 C. albicans의 세포용해를 야기함을 관찰할 수 있었다. Crystal violet 흡수율 실험으로 R. undulatum에 의한 세포막 투과성의 변화를 관찰하였다. 따라서 R. undulatum은 세포막의 손상과 세포막의 투과성 변화로 야기된 세포의 용해와 관련된 항진균 활성이 C. albicans의 바이오필름 형성을 억제하는 것으로 보여진다. 본 연구의 결과는 R. undulatum이 바이오필름과 관련된 캔디다의 감염을 치료하고 제거하기 위한 천연물 기반 항진균제 개발에 대한 좋은 후보물질임을 보여준다.
목적: 성장판이 남아 있는 청소년기 환자에서 발생한 경골 과간부 견열 골절에 대해 생흡수성 핀을이용한 간단한 관절경적 정복 및 고정 방법을 소개하고자 한다. 수술 술기: 전외측 및 전내측 삽입구를 통하여 진단적 관절경 검사를 시행 후, 손상부를 잘 관찰하기 위하여 미세 골절파편과 응고된 혈액을 제거한다. 탐침을 이용하여 골절편을 정복한 상태에서 1.1 mm K-강선을 관절의 전상부에서 경피적으로 삽입하여 임시로 골절편을 고정한다. 드릴 가이드를 관절 내로 삽입 후, poly-p-dioxanone로 만들어진 40 mm 길이의 생흡수성 핀들을 다양한 각도에서 삽입하여 골절편을 완전히 고정한다. 수술 후 슬관절을 신전시킨 상태에서 장하지 석고 고정을 4주간 시행하여 술 후 슬관절의 완전 신전이 가능하도록 한다. 결론: 전방십자인대에 의한 경골 과간부 견열 골절을 생흡수성 핀을 이용하여 관절경적으로 고정하는 술기는 기술적으로 어렵지 않으며, 골절 치유와 관절의 안정성을 얻을 수 있는 수술 방법이다.
소아 흉부 CT 검사 시 방사선 피폭을 최소화 하면서 진단적으로 가치가 높은 영상을 얻기 위해서 Helical mode, High-pitch mode, Volume Axial mode를 적용하여서 선량, 검사시간, 화질을 비교하여 유용성을 평가하고자 한다. Revolution(GE Healthcare, Wisconsin USA)을 이용하여 PBU-70팬텀을 Helical mode, High-pitch mode, Volume Axial mode로 각각의 그룹으로 나누어서 관전압 80kVp, 조건으로 30회 검사를 실시하였다. 영상을 획득 한 후에 각각의 영상에 심장(Heart), 뼈(Bone), 폐(Lung), Back-ground air에 ROI를 설정하고 CT number(HU)와 noise(SD)값을 측정하여 평균값을 구하고 SNR과 CNR을 측정하였고, 장비에서 직접 제공하는 DLP값 비교하였다. 통계적인 유의성을 확인해보기 통계 분석은 SPSS 21.0을 사용하여 ONE-WAY-ANAOVA를 시행하였다. 본 실험을 통해 검사 시 volume axial mode 사용 시 가장 적은 선량으로 영상의 화질 저하 없이 빠른 시간에 검사가 가능하였다. 16cm의 detector coverage 가 모든 소아 흉부 CT검사에 적용하기에 제한점이 있으나 가능한 소아환자에 있어 적극적인 활용을 추천하며 volume axial mode의 다른 검사부위 적용에 대한 지속적인 연구가 필요하리라 사료된다.
간 역동적 CT(Liver Dynamic Computed Tomography; LDCT) 검사에서 일반적으로 사용하는 프로토콜과 관전압을 낮게 설정한 후 프로토콜을 변화시켰을 때 방사선량과 영상의 질을 비교하여 영상의 질을 유지하면서 방사선량을 감소시킬 수 있는 방안을 알아보고자 하였다. LDCT를 시행한 환자 중 신체질량지수(body mass index; BMI)가 18.5~24인 환자 40명을 대상으로 일반적인 복부 CT 검사 프로토콜을 적용한 A그룹 20명(관전압: 120 kVp, SAFIRE strength1)과 관전압을 낮게 설정한 B그룹 20명(관전압: 100 kVp, SAFIRE strength 0~5 적용)이었다. 영상의 질 평가는 동맥기의 간 실질 조직, 대동맥, 상장간막동맥, 복강동맥, 내장지방 그리고 백그라운드에 관심영역(region of interest; ROI)을 설정해 잡음(noise), 신호대 잡음비(signal to noise ratio; SNR), 대조도 대 잡음비(contrast to noise ratio; CNR), CT number를 측정 비교하였다. 또한 정성적 평가는 경험이 풍부한 영상의학과 전문의 2명이 0~3점까지로 평가하였다. 방사선량은 총 DLP(dose length product)와 유효선량, CTDIvol(volume computed tomography dose index)을 비교하였다. 관전압 100 kVp에서 SAFIRE가 높을수록 잡음은 감소하고, CT number는 증가하였다. 따라서 SNR과 CNR은 SAFIRE 단계가 높을수록 증가하였다. 관전압 120 kVp와 비교하여 잡음, SNR, CNR이 SAFIRE strength 2, 3에서 가장 유사하였다. 정성적 평가는 SAFIRE strength 2가 가장 많았고 관전압이 100 kVp일 때 영상의 질이 더 좋다고 평가한 경우는 SAFIRE 1이었다. 방사선량은 120 kVp에 비해 100 kVp에서 21.69% 감소하였다. BMI가 비교적 높지 않은 LDCT 검사의 경우 공장에서 출고될 당시에 관전압이 높게 설정되어 있어 불필요한 방사선피폭이 우려되고 있는 현실을 고려하면, 본 연구 결과에 따라 관전압을 낮게 설정하고 SAFIRE strength를 2로 조정하면 영상의 질 저하 없이 방사선량도 감소시킬 수 있을 것으로 사료된다.
The ultimate goal of periodontal therapy is the regeneration of periodontal tissue which has been lost due to destructive periodontal disease. To achieve periodontal regeneration, various kinds of methods have been investigated and developed, including guided tissue regeneration and bone graft. Bone graft can be catagorized into autografts, allografts, xenografts, bone substitutes. And materials of all types have different biological activity and the capacity for periodontal regeneration, but ideal graft material has not been developed that fits all the requirement of ideal bone graft material. Recently, bioactive glass that has been utilized in plastic surgery is being investigated for application in dental practice. But, there has not been any long-term assessment of bioactive glass when used in periodontal intrabony defects. The present study evaluates the long-term effects of bioactive glass on the periodontal regeneration in intrabony defects of human and the effect of plaqu control on long term treatment results after dividing patients into those who underwent 3-month regular check-up and those who didn't under go regular check-up The clinical effect on 74sites from 17 infrabony pockets of 11 patients were analyzed 36months after treatment. 51 sites which underwent regular check up were classified as the Follow-up group(F/U group), and 23 sites which did not undergo regular check up were classified as Non Follow-up group(Non F/U group). After comparing the probing depth, attachment loss, bone probing depth before and 36months after treatment, the following results could be concluded. 1. The changes of probing pocket depth showed a statistically significant decrease between after baseline and 36 months after treatment in F/U group(1.79${\pm}$0.68mm) and did no show astatistically significant decrease between after baseline and 36months after treatment in Non F/U group(0.61${\pm}$0.54mm) (P<0.05). 2. The changes of loss of attachment showed a statistically significant decrease between after baseline and 36 months after treatment in F/U group(1.44${\pm}$0.74mm) and did no show astatistically significant decrease between after baseline and 36months after treatment in Non F/U group(1.18${\pm}$1.54) (P<0.05). 3. The changes of bone probing depth showed a statistically significant decrease between after baseline and 36 months after treatment in both F/U(1.35${\pm}$0.28) and Non F/U group(0.78${\pm}$0.55mm) (P<0.05). The results suggest that treatment of infrabony defects with bioactive glass resulted in significan reduction of attachment loss and bone probing depth 36months after the treatment. The use of bioactive glass in infrabony defects, combined with regular check-up and proper plaque control generally shows favorable clinical results. This measn that bioactive glass could be a useful bone substitute.
목 적: 본 연구는 난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 HalcyonTM Fast kV CBCT를 사용하였을 때 난소에 미치는 흡수선량과 영상의 품질을 분석하여 유용성을 평가하고자 한다. 대상 및 방법: 인체모형 팬텀(Alderson Rando Phantom, USA)의 전산화단층촬영 영상에 측정에 필요한 자궁경부와 난소의 윤곽묘사(contouring)를 하였고, 해당 장기 단면에 광자극발광선량계(Optically Stimulated Luminescence Dosimeter, OSLD, InLight system, Landauer, USA)를 각각 3개씩 부착하였다. TruebeamTM의 Pelvis mode(이하 TP)와 HalcyonTM의 Pelvis mode(이하 HP) 그리고 HalcyonTM의 Pelvis Fast mode(이하 HPF)에서 자궁경부와 난소에 들어가는 흡수선량을 측정하기 위해 촬영 범위를 17.5 cm와 12.5 cm로 촬영 범위를 축소한 영상을 촬영하였다. 총 10회의 누적선량을 합산하였고, 자궁경부암 치료 횟수인 23회의 값으로 치환하여 비교하였다. 또한 영상 장비 간의 CBCT 영상 품질을 비교하기 위해 Catphan 504 팬텀(The Phantom Laboratory, USA)을 이용하여 균일도(Uniformity), 저 대조도 가시(Low contrast visibility, LCV), 공간분해능(Spatial resolution), 기하학적 왜곡(Geometric Distortion)을 비교 분석하였다. 각각 3회 반복 측정하여 Doselab (Versions: 6.8, Mobius Medical Systems) 프로그램으로 분석 후 평균값을 구하였다. 결 과: CBCT에 의한 흡수선량을 OSLD로 측정한 결과 동일한 조건일 시 TP와 HP는 유의미한 결과를 얻지 못하였다. 가장 큰 감소 값을 보인 모드는 TP 대비 HPF였다. HPF는 17.5 cm의 촬영 범위에서 흡수선량이 TP보다 자궁경부가 약 39.82%, 난소에서 약 19.8% 감소 하였고, 12.5 cm 으로 촬영 범위를 축소할 경우 자궁경부는 34.2%, 난소 50.5%로 감소 시킬 수 있었다. 또한 위 실험에서 사용된 영상의 품질을 평가한 결과 Geometric Distortion 1mm 이내(SBRT 기준), Uniformity HU, LCV 2.0% 이내 Spatial Resolution 3 lp/mm 이상으로 장비사의 기준치를 준수하였다. 결 론: 본 실혐 결과에 따라 난소전위술을 시행한 가임기 여성의 방사선치료 시 CBCT로 인한 피폭선량을 낮추기 위해서는 TruebeamTM 보다 다양한 조건을 선택 할 수 있는 HalcyonTM이 유용할 것으로 평가 되며, 특히 낮은 mAs로도 영상의 품질을 유지하는 HalcyonTM의 Fast kV CBCT를 권장한다. 다만 다른 치료 장비에서도 난소전위를 시행한 환자는 촬영 범위를 조정하는 것으로 저선량에 대한 추가적인 피폭 감소시킬 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.