• Title/Summary/Keyword: Reduction in Area

검색결과 3,813건 처리시간 0.03초

기능적 전기 자극과 유산소 운동이 복부비만의 피하지방과 내장지방에 미치는 효과 (The Change of The Effect on The Subcutaneous Fat Area and Visceral Fat Area by The Functional Electrical Stimulation and Aerobic Exercise)

  • 오성태;이문환;박래준
    • The Journal of Korean Physical Therapy
    • /
    • 제16권1호
    • /
    • pp.85-123
    • /
    • 2004
  • Back ground : Subcutaneous fat area is the main factor involved in replacement disease and arteriosclerosis. Simple weight control is the appropriate medical treatment. It's understood that weight reduction does not only reduce the fat concentrations in blood but also reduces blood pressure, improves glucose levels in diabetes patients and reduces incidents of heart disease. there are several methods for reducing fat in the abdominal region but their effectiveness is not folly understood. one method is electrical stimulation of the problem areas. Method : From May 1st 2002 to October 31st. The 15 subjects who received medical examination were aged between 25 and 53 and were of mixed gender. The subjects were divided into two groups one to received functional electrical stimulation and the other a control group. Using Broca's criterion for judging fat grades. I analysed the differences between the two groups before and after the treatment. Subjects received functional electrical stimulation on the abdominal muscle intensity 50Hz. They received this treatment 4 days a week for 40 minutes a day. In the case of aerobic exercise, at the Treadmill, we used it with the intensity of $75\%$ maximum heart rate (220-age). Result 1)After functional electrical stimulation in the case of male subjects, the weight was reduced 1.93kg, obesity $2.60\%$, fat mass 2.73kg, Percent body fat $4.40\%$, waist circumference 6.53cm, circumference of hips 5.53cm. On the other side, the quality of muscle was increased at the rate of 1.03kg, but it's not attentional level. The subcutaneous fat area was reduced by $26.63cm^2$, the visceral fat area was reduced by $43.00cm^2$, In the female subjects, we can see the reduction of fat grade by $26.63cm^2$, the quantity of body fat by 1.5kg, percent body fat by $1.77\%$, circumference of waist by 4.02cm, circumference of hips by 3.67cm, weight by 1.40kg but was increased 0.72kg at the quantity of muscles. We can see the reduction also in the subcutaneous fat area $24.03cm^2$, the visceral fat area by $25.36cm^2$. 2)After aerobic exercise, on the male subjects, we can see reduction of weight by 3.36kg, obesity by $4.00\%$, fat mass by 2.83kg and we can see increase at the soft lean mass by 2.96kg, but we can see reduction, the percent body fat by $3.03\%$, fat distribution by $0.023\%$, circumference of waist by 3.10cm, circumference of hips by 2.23cm. The female subjects show a reduction in the weight by 2.48kg, percent body fat by $2.20\%$, show an increase in the soft lean mass by 1.54kg. We can see a reduction in the quantity of fat mass by 2.32kg, the percent body fat by $2.80\%$, the circumference of waist by 2.16cm, the circumference of hips by 2.68cm, the fat distribution by $0.016\%$, the subcutaneous fat area by $15.25cm^2$ the visceral fat area by $11.52cm^2$. After aerobic exercise, we can't see the attentional change at the total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. 3)After the application of functional electrical stimulation and aerobic exercise, in result of measurement on the body ingredient, we could see the weight reduction and increase the quantity of muscle with the male group who exercised aerobic. We can see the attentional rate on the electrical stimulation about abdominal fat rate, circumference of waist, circumference of hips. The other hand, I couldn't see the attentional differences between the two groups in the rate of fatness and quantity of body fat and the rate of body fat. There isn't any attentional difference in the area of fat under skin, on the contrary, There is attentional difference in the fat in the internal organs area at the electrical stimulation site. We can't see the attentional change of total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol between electrical stimulation and aerobic exercise. 4)After execution of functional electrical stimulation and aerobic exercise, in result of measurement on change of body ingredient among female objects, We could see weight reduction, increase at muscle quantity in the aerobic exercise group. We could see the attentional differences in the rate of fatness, the rate of abdominal region, the circumference which received electrical stimulation. But, we couldn't see the attentional differences between two groups in the quantity of body fatness, the circumference of hips. The subcutaneous fat area doesn't show the attentional differences. On the Contrary, we could see lots of differences in the visceral fat area of the electrical stimulation group. Conclusion The results show that functional electrical stimulation and aerobic exercise have insignificant differences when if comes to total cholesterol, triglyceride, high density lipoprotein cholesterol, low density lipoprotein cholesterol. Though there is affirmative change in body ingredient after both electrical stimulation and aerobic exercise. Functional electrical stimulation is more effective on the subcutaneous fat area and in changing visceral fat area. There fore. It is concluded that the physical therapy is more effective in the treatment of abdominal fatness.

  • PDF

The Analysis of Reduction Efficiency of Soil Erosion and Sediment Yield by a Ginseng Area using GIS Tools

  • Lee, Geun-Sang;Jeon, Dae-Youn
    • Spatial Information Research
    • /
    • 제17권4호
    • /
    • pp.431-443
    • /
    • 2009
  • 최근 탁수문제는 댐과 저수지관리 업무에서 중요한 이슈중의 하나가 되고 있으며, 고탁수를 유발하는 주요원인은 강우강도 에너지에 의한 유사량이다. 기존의 연구들은 다양한 작물형태를 고려하지 않아 정확한 토양 침식 및 유사량을 계산할 수 없었다. 본 연구에서는 IKONOS 위성영상으로부터 추출한 인삼밭 레이어를 이용하여 토양침식량과 유사량의 저감효과를 분석하였으며, 인삼밭의 면적과 점유비율은 각각 $0.290km^2$와 0.94%로 나타났다. GIS 기반 RUSLE 모델을 이용하여 인삼밭을 고려한 토양침식량의 저감효과를 분석한 결과는 0.9%로 낮게 나타났으며, 이는 인삼밭의 면적이 다른 농경지에 비해 상대적으로 작기 때문으로 해석된다. 미래의 토지이용변화를 반영하기 위해, 본 연구에서는 논, 밭, 과수원 그리고 기타 재배지들이 인삼밭 지역으로 전환된다는 시나리오를 고려하여 토양침식과 유사량의 저감효과를 평가하였다. 시나리오에 따른 인삼밭의 저감효과를 분석한 결과, 밭지역을 인삼밭으로 전환한 시나리오 (1)과 모든 농경지를 인삼밭으로 전환한 (4)가 인삼밭을 고려하지 않은 기존의 연구와 비교할 때 31.3% 및 34.8% 더 높은 저감효과를 나타내었다. 본 연구에서 제시한 방법론은 고탁수와 관련된 저수지관리를 지원하기 위한 매우 효과적인 도구가 될 수 있을 것이다.

  • PDF

대형주강의 고온파단형태에 미치는 [Mn/S]비의 영향 (The Influence of [Mn/S] Ratios on the Fracture Morphology of a Heavy-section Steel Castings at Elevated Temperature)

  • 김성규;김지태;박봉규;박흥일
    • 한국주조공학회지
    • /
    • 제34권5호
    • /
    • pp.170-178
    • /
    • 2014
  • Using the Gleeble test, the effects of [Mn/S] ratios and the presence of sulfides on the high-temperature fracture morphology of heavy-section steel castings were analysed via the observations of the microstructures. The specimens for which the [Mn/S] ratio was in the range of 60~80 showed a ductile fracture morphology with an area reduction of more than 60%, while some specimens with similar [Mn/S] ratios showed a brittle fracture morphology with an area reduction of 0.0% due to the liquidation of sulfides at the grain boundary. The fracture morphology was classified into three types in the Gleeble high-temperature tensile test specimens. The first type showed dimple formation at the grain boundary, the formation of globular MnS sulfides, and plastic deformation of sulfides at an elevated temperature, indicating a needle-point type of ductile fracture with area reductions of 96.0~97.8%. The second type was a knife-edge type brittle fracture with an area reduction of 0.0% due to the film-type liquidation of sulfides at the grain boundary, band-type liquidation, and the liquidation of a terraced nipple pattern. The third type was the typical ductile fracture with an area reduction of 31.3~81.0%, in accordance with the mixture of dimples with in the grains and terraced nipple pattern at the grain boundary.

OZIPR을 이용한 서울지역 광화학오존농도 저감방안에 관한 연구 (A Study on the Reduction of Photochemical Ozone Concentration using OZIPR in Seoul Area)

  • 홍유덕;이상욱;한진석;이석조;김신도;김윤신
    • 환경영향평가
    • /
    • 제14권3호
    • /
    • pp.117-126
    • /
    • 2005
  • This study was executed to know the best matrix of photochemical ozone reduction in the metropolitan area. For this object, we used the OZIPR(Ozone Isopleth Plotting Package for Research) model for comparing the effectiveness of VOCs and NOx amount variation about the ozone creation. Among the various ozone reduction scenarios, 50% reduction of VOCs from organic solvent and road traffic respectively was the best matrix for ozone reduction. Although it needs more accurate assessment and confirmation of VOCs and NOx emission amount data, according to existing data, the control of VOCs is the best way for photochemical ozone reduction in Seoul.

영역축소 기법을 이용한 협력위치추정 알고리즘의 성능분석 (Performance Analysis of Cooperative Localization Algorithm with Area Reduction Method)

  • 정승희;오창헌
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.1053-1056
    • /
    • 2009
  • 본 논문에서는 실내외 환경에서 상호 정보를 바탕으로 대상의 위치를 추적할 수 있는 영역축소 기법을 이용한 협력 위치추정 알고리즘을 제안하였다. 제안한 알고리즘은 고정노드의 수가 제한된 환경에서 미지의 노드 위치 정보를 활용한 상호 협력적인 위치추정 방식으로 본 연구에서는 3단계에 걸쳐 노드의 위치를 추정하였다. 실험 결과 동일한 개수의 RN일 때 BN의 수가 증가할수록 본 논문에서 제안한 영역축소 방법을 이용한 협력위치추정의 정밀도가 향상됨을 확인하였다.

  • PDF

익산 밭경지 특성을 고려한 초생대 유출 및 유사 저감효과 모의 (Simulations of Reduction Effects on Runoff and Sediment for VFS Applications by Considering Uplands Characteristics in Iksan)

  • 이슬기;장정렬;최경숙
    • 한국농공학회논문집
    • /
    • 제56권5호
    • /
    • pp.89-99
    • /
    • 2014
  • The goal of this study was to evaluate sediment reduction effects of VFS (vegetative filter strip) applied for Iksan area in Saemangeum watershed. This study simulated runoff and sediment load from different types of uplands using VFSMOD-W. The general upland characteristics of the study area was investigated to build reasonable scenarios of the simulation. The simulation scenarios were designed by various areas, shapes, and slopes of uplands. Grass mixture was selected as VFS vegetation and the size of VFS was fixed as 10 % of uplands area. Additionally 50mm, 100mm, 150mm of daily rainfall were applied for the runoff and sediment simulation. As results, the calculated runoff and sediment loads were obtained $20.7{\sim}1,030.6m^3$ and 568.4~675,731.4 kg for the range of 0.1~1.0 ha of uplands with 7 % and 15 % slopes. The reduction effects on runoff and sediment were obtained 5~10 % and 21.0~47.7 % respectively from VFS applications. The VFSMOD-W simulations showed that runoff tended to increase as upland area and amount of rainfall increased while sediment increased when slope, length and area of uplands and amount of rainfall increased. These results indicated that rainfall amount and upland size are the critical factors for the generation of runoff and sediment load. In order to support this conclusion, further studies such as, long term monitoring, field experiments, and to calibrate and evaluate the model are necessary.

유출저감을 위한 유역내 침투시설의 적용 (An Application of Infiltration Facilities for Reducing the Runoff in the Basin)

  • 이재준;설지수
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.133-141
    • /
    • 2011
  • 유역의 도시화는 유출총량과 첨두유량의 증가와 도달시간이 감소시키며, 홍수피해의 위험성을 더욱 크게 만든다. 침투시설은 도시유역의 유출총량과 첨두유량을 감소시킬 수 있고, 그 종류에는 침투트렌치와 투수성 포장재 등이 있다. 본 연구에서는 침투시설 설치에 따른 우수유출저감효과를 알아보기 위하여 경북 구미시 옥계동의 $0.18km^2$와 공단동의 $0.67km^2$의 면적을 가진 도시유역을 대상으로 하여 각각의 유역특성을 분석하고, 유출총량 및 첨두유량의 저감량을 WinSLAMM 모형을 이용하여 분석하였다. 또한, 침투시설 설치에 따른 첨두유량저감효과를 분석하였고, 침투시설 면적비와 유출저감률과의 관계식을 도출하였다.

잡음 발생기의 저면적, 저전력 방안에 관한 연구 (A Study on Low Area/Power Schemes of Noise Generation System)

  • 이창기
    • 한국컴퓨터산업학회논문지
    • /
    • 제4권4호
    • /
    • pp.433-442
    • /
    • 2003
  • 통신 시스템의 성능은 여러 가지 요구 조건을 고려하여 측정되어져야 한다. 이러한 목적으로 잡음 발생기는 주어진 특성을 갖는 잡음 신호를 생성하는데 사용되어진다. 최근의 연구에서 잡음 모델이 복잡한 PSD를 갖는 경우 DCT를 이용한 잡음 발생기가 기존의 잡음 발생기보다 우수한 성능을 보였다. 본 논문에서는 DCT 기반 잡음 발생기에서 DCT를 제외한 회로의 면적을 줄일 수 있는 구조와 전력을 최소화시킬 수 있는 구조를 제안한다. 모의실험에서 면적을 최소화하기 위한 구조는 61-64%의 면적을 줄였으며, 전력을 고려한 구조에서는 88-89%정도의 전력소모를 감소를 예측할 수 있다.

  • PDF

통기성 상자 구조물의 강도적 최적화 연구(I)-실증 분석 (Strength Optimization of Ventilating Container(I)-Experimental Analysis)

  • 박종민
    • 한국포장학회지
    • /
    • 제7권2호
    • /
    • pp.19-24
    • /
    • 2001
  • 현재 국내에는 통기성 상자의 설계에 관한 기준이 마련되어 있지않아, 통기공으로 인한 상자 압축강도 저하와 통기성 면에서도 좋지 않은 형편이다. 선진 외국과는 물류 및 포장환경이 다르고, 방법에 있어서도 큰 차이가 있기 때문에 외국의 사례를 국내의 포장설계에 적용하는 데는 한계가 있다. 따라서 본 연구는 현재 국내에서 유통되는 통기성 상자에 대한 실태분석과 온 습도 변화에 따른 압축강도 저하와 통기성을 분석하므로써, 통기성 상자의 최적설계를 위한 설계 기준을 마련하고자 수행되었다. 현행 유통되는 통기성 상자의 통기공의 면적 비율은 $1.41{\sim}2.65%$ 였으며, 통기공의 형태, 크기 및 위치가 매우 다양하여, 이로 인한 상자 압축강도 저하율은 $8.5{\sim}20.2%$의 범위에 있었다. 대체로 통기공의 면적비율 보다는 통기공의 형태와 위치가 상자의 압축강도 저하에 미치는 더 중요한 요인으로 분석되었다. 통기공의 면적비율이 클 수록 온도와 상대습도의 평형도달시간은 짧았으며, 온도가 상대습도에 비하여 더 빨리 형평상태에 도달하였으며, 또한 통기공의 면적 비율이 같은 경우, 통기공의 형태에 따른 온도 및 상대습도의 평형도달 시간과 평형도달 온 습도에 있어서는 큰 차이가 없었다.

  • PDF

밭 비점오염저감을 위한 잔디초생대 적용 비용 및 활용성 평가 (Estimation of Application Cost and Utilization of Turf Grass VFS for Reduction of Uplands NPS Pollution)

  • 이슬기;장정렬;최경숙
    • 한국농공학회논문집
    • /
    • 제57권2호
    • /
    • pp.75-83
    • /
    • 2015
  • This study was aimed to estimate the total application cost and utilization of Turf grass VFS application through the field experiment. The experimental plots were constructed in an upland field of Iksan city within the Saemangeum watershed. Turf grass was transplanted at the down-slope edge of the pollution source area in each of the treated plots. Three rainfall events were monitored during the experiment period, and the rainfall-runoff relationships and NPS pollution reduction effects of the VFS systems were assessed. As results, the reduction ratio of runoff volume ranged 14.1~64.0 %, while the NPS pollution reduction ratio ranged 9.8~73.9 % for SS, 24.0~84.2 % for T-N, 31.6~80.9 % for T-P respectively. The total cost of VFS application was estimated by considering purchase cost of Turf grass sods and construction and maintenance costs of VFS system as well as the loss caused by giving up crop cultivation for the area needed to construct the VFS. The total cost of the VFS was estimated to be approximately \3,379,000/ha/year for the first year of application, and this cost could be decreased to \1,899,000/ha/year from the second year as the construction cost of VFS could no longer need to be counted afterwards. Apart from the NPS pollution reduction effects, the possible utilization of VFS was examined by detaching Turf grass within 40 % of VFS area for sale during spring time when the VFS systems fully covered. The benefit of selling the detached Turf grass sods was estimated as \1,260,000/ha/year, and also found that the VFS area successfully recovered by the time of the summer period. This benefit could attract farmers to adopt the VFS technique to manage agricultural NPS pollution.