• Title/Summary/Keyword: Reduction device

Search Result 1,286, Processing Time 0.028 seconds

Development of Rotary Transfer Forming Device for Process Reduction in Forming (프레스 공정 단축을 위한 회전식 트랜스퍼 성형장치 개발)

  • Kim, Seung-Gi;Youn, Jae-Woong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.5
    • /
    • pp.413-420
    • /
    • 2014
  • Although the transfer forming process has various advantages, it is also inefficient for the use of multiple press machines, especially for small part sizes. In this study, a new forming process was proposed to use multiple tandem dies in a single press machine. A rotary transfer forming device was developed to combine the advantages of the progressive and transfer forming process. In this study, a detailed forming process using this device was analyzed, and the device was designed to perform four series of tandem forming processes in a single press. In order to analyze the feasibility of this forming process, simple forming dies were made. As a result, the position accuracy was 4 arcsec, and the forming speed reached up to 20 strokes per minute. It is thought that this rotary transfer forming device can help to save initial setup costs through the more efficient use of space in a press machine.

Effects of Irrigation/Aspiration Device and Viscoelastic Material on Complication after Extracapsular Lens Extraction in Dogs (개에서 Irrigation/Aspiration장비와 점탄물질이 수정체 낭외적출술후의 합병증에 미치는 효과)

  • 우흥명;권오경;남치주
    • Journal of Veterinary Clinics
    • /
    • v.14 no.1
    • /
    • pp.56-64
    • /
    • 1997
  • These studies were performed to investigate the complications affecting the vision after extracapsular lens extraction(ECE), the effects of an I/A (irrigation & aspiration)device and a viscoelastic material used on the vision, the occurrence of complications and the effective corneal incision method to reduce the corneal opacity in dogs. ECE was performed bilaterally with 3 different methods using clinically normal twele mixed dogs; the method in which I/A device and viscoelastic material were not used, the method in which I/A device was used but viscoelastic material not, and the method in which I/A device and viscoelastic material were used. Postoperative complications were observed as followed; conjunctival injection, uveitis, corneal opacity due to endothelial cell loss, hyphemia, remnants of lens cortex, vitreous loss, synechia and capsular opacity. Preservation rate of vision was lower significantly in the cases showing signs of synechia, capsular opacity, or remnants of lens cortex than the cases not showing the above signs(p<0.01). There were significant reduction of the complications such as corneal opacity, clot in anterior chamber in the group using I/A device compared to the group in which I/A device was not used(p<0.01). Groups using I/A device showed slightly higher vision than the group not using I/A device (75%; 42%). There were no significant differences in the occurrence rate of complications and the preservative rate of vision between the groups with and without viscoelastic material. The present study indicated that the postoperative complications of posterior synechia, capsular opacity, uveitis and vistreous loss were important factors affecting the vision and that I/A device was applicable to extract the lens cortex and effective to elevate the success rate after ECE in dogs.

  • PDF

Development of Vibration Absorption Device for the Transportation-Trailer System(II) - Connecting Hitch for Power Tiller-Trailer - (수송 트레일러의 충격흡수장치 개발(II) - 동력경운기 연결 히치 -)

  • Hong J. H.;Lee H. J.;Lee S. B.;Park W. Y.;Kim S. Y.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.147-154
    • /
    • 2005
  • The improved hitch device, which connecting the trailer to power tiller, was developed. This device, composed with spring and rubber, could reduce the vibration and shock levels during driven on off-road. The vertical vibration accelerations for the improved hitch device were measured at 6 positions, i.e. engine, hitch, seat, and three points in trailer (front, middle, and rear) for not driving but at low engine speed of 500 rpm, and compared with the existing hitch device. The results of this study could be summarized as follows; The average vibration acceleration up to 120 Hz was $0.4m/s^2$ at engine part, but it was 0.08 and $0.05m/s^2$ at trailer for existing and improved hitch device, respectively. About $38\%$ of average acceleration level could be absorbed for the improved hitch device compared with existing hitch device. The average vibration acceleration up to 40 Hz was reduced to 0.12 and $0.06m/s^2$ at trailer for existing and improved hitch device respectively, showing the reduction effect of $50\%$. The maximum acceleration occurred at up to 20 Hz of low frequency was much higher than total acceleration occurred at up to 120 Hz, which means that much loss or damage could be occurred during transporting of agricultural products on off-road. The portions of average acceleration occurred at up to 20 Hz of low frequency were $27\%\;and\;21\%$ for the existing and improved hitch device, respectively.

Voltage Stress of Switching Device in dc/dc Converter (dc/dc 컨버터의 스위칭 소자의 전압 스트레스)

  • Ma, K.S.;Choi, J.H.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1019-1021
    • /
    • 1992
  • This paper deals with the stress of the converters using the resonant switches. It is represented the reduction of the voltage and current stresses. According to the configuration of the multiple poly-phase converter. Especially, about buck ZVS-QRC it is studied the reduction of the voltage stress, and represented the result of simulation.

  • PDF

Neutral Current Reduction Method Using Single-Phase Inverter (단상 인버터를 사용한 중성선 전류 저감 기법)

  • Min, Joon-Ki;Kim, Hyo-Sung;Choi, Jao-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.155-157
    • /
    • 2005
  • This paper analyzed the adoption possibility of a low cost single phase active power filter as the neutral current reduction device in three-phase four-wire power system with the balanced or/and unbalnaced nonlinear load conditions. Proposed system can make neutral line current to within rated vale without the phase current THD change of the installed phase line.

  • PDF

A study on imaging device sensor data QC (영상장치 센서 데이터 QC에 관한 연구)

  • Dong-Min Yun;Jae-Yeong Lee;Sung-Sik Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

Threshold Voltage Control through Layer Doping of Double Gate MOSFETs

  • Joseph, Saji;George, James T.;Mathew, Vincent
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.3
    • /
    • pp.240-250
    • /
    • 2010
  • Double Gate MOSFETs (DG MOSFETs) with doping in one or two thin layers of an otherwise intrinsic channel are simulated to obtain the transport characteristics, threshold voltage and leakage current. Two different device structures- one with doping on two layers near the top and bottom oxide layers and another with doping on a single layer at the centre- are simulated and the variation of device parameters with a change in doping concentration and doping layer thickness is studied. It is observed that an n-doped layer in the channel reduces the threshold voltage and increases the drive current, when compared with a device of undoped channel. The reduction in the threshold voltage and increase in the drain current are found to increase with the thickness and the level of doping of the layer. The leakage current is larger than that of an undoped channel, but less than that of a uniformly doped channel. For a channel with p-doped layer, the threshold voltage increases with the level of doping and the thickness of the layer, accompanied with a reduction in drain current. The devices with doped middle layers and doped gate layers show almost identical behavior, apart from the slight difference in the drive current. The doping level and the thickness of the layers can be used as a tool to adjust the threshold voltage of the device indicating the possibility of easy fabrication of ICs having FETs of different threshold voltages, and the rest of the channel, being intrinsic having high mobility, serves to maintain high drive current in comparison with a fully doped channel.

Catch and Bycatch of Dredge in the Yeongil Bay, Pohang (포항 영일만 형망어업의 어획 및 혼획 실태)

  • AN, Heui-Chun;PARK, Hae-Hoon;PARK, Jong-Myung;HONG, Sung-Eic;YOON, Byoung-Sun;PARK, Chang-Doo;BAE, Jae-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.4
    • /
    • pp.493-503
    • /
    • 2015
  • Species composition and bycatch rate of the catches by dredge with bycatch reduction device to reduce bycatch were estimated around Yeongil Bay, Korea at June, 2015. Total catches were collected 31 species as Chordata 10 species, mollusca 8 species, arthropoda 6 species, echinodermata 5 species, sipunculida 1 species, annelida 1 species during the experiment at the Yeongil Bay. The dominant species were Scapharca broughtonii, Callithaca adamsi, and Atrina pectinata and they reached 79.9% of the total catch. The catch rate of Scapharca broughtonii and Callithaca adamsi was 69.6% and 10.4% respectively. The rate of bycatch was 20.1%, consisted with Echinodemata 13.0%, Chordata 3.6%. The catch of ordinary dredge was 27 species 1,307 number 85,052g and that of dredge with escapement device was 21 species 1,690 number 91,648g. In conclusion, the dredge gear with bycatch reduction device has higher catch rate of target species and lower bycatch rate to non-target species than ordinary one.

Assessment of Treatment Outcome after Using Temporary Mandibular Advancement Devices in Obstructive Sleep Apnea Patients (폐쇄성 수면 무호흡 환자에서 임시 하악 전방 이동 장치를 이용한 치료결과 분석)

  • Park, Joon-Hyung;Oh, Suseok;Hong, Jongrak;Kim, Chang-Soo;Paeng, Jun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.426-431
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effect of temporary mandibular advancement devices (MAD) in obstructive sleep apnea (OSA) patients Methods: 28 patients (male 21, female 7) undergoing temporary mandibular advancement device treatment for OSA were selected from 2011.01. to 2012.02. in the department of Oral & Maxillofacial Surgery at SamsungMedicalCenter. Treatment efficacy was determined by polysomnography (PSG) at baseline & after MAD delivery. The response group was defined as >50% Apnea-Hypopnea Index (AHI) reduction plus post-MAD AHI <10, and the non-response group was defined as <50% AHI reduction. The lateral cephalogram was analysed including SNA, SNB, UL, MPH, PAS, PASU, and PAST using V-ceph$^{TM}$ (Cybermed, USA). Results: The responsers were 23 patients, and non-responsers were 5 patients. The AHI was significantly reduced with temporary MAD ($8.08{\pm}7.93$) compared with baseline ($28.51{\pm}20.56$) in the response group (n=23). No significant difference was observed between pre MAD and post MAD except SNB on cephalometric analysis. Among 11 patients successfully treated with the temporary device, 9 patients said that using permanent device brings better effect too. Conclusion: These results indicate that the Temporary MAD could not be the only effective tools on OSA but also be used to predict patient's reactivity about permanent appliance treatment. Further studies are warranted to evaluate the relations between temporary MAD and permanent MAD.

Efficacy of the Anteriorly Adjustable Mandibular Advancement Device on the Treatment of Obstructive Sleep Apnea

  • Jang, Hoon-Ho;Kim, Hye-Kyoung;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.41 no.1
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: Mandibular advancement device (MAD) is widely recognized as an important treatment option for obstructive sleep apnea (OSA) and is readily accepted than any other treatment options owing to its simplicity and ambulatory nature. At this time, there are a multitude of MAD designs and their efficacies may be influenced by adjustment and retention mechanism. The MAD with the anterior connector (anteriorly adjustable mandibular advancement device, AAMAD) was newly developed in the Department of Oral Medicine, Dankook University Dental Hospital (Cheonan, Korea) and was prescribed for the OSA patients including snoring patients. Thus, this study was aimed to objectively investigate the effectiveness of the AAMAD on the OSA patients using the self-applied portable device (ApneaLink), and evaluate the treatment outcomes among patients with various severity of OSA level. Methods: Results of the treatment of fourteen patients (13 male, 1 female) with the AAMAD were retrospectively analyzed. Each patient underwent home sleep test before treatment and were divided into two groups, i.e., those with mild (apnea-hypopnea index [AHI] ${\geq}5$ and <15) to moderate OSA (AHI ${\geq}15$ and <30) and severe OSA (AHI ${\geq}30$). After treatment, home sleep test was conducted again and treatment outcomes were compared between mild to moderate and severe OSA patients. Results: Of all patients, 78.6% showed more than 50% AHI reduction. We found a significant reduction (85.3%) of AHI in the severe OSA patients. Patients with mild to moderate OSA showed the reduced AHI (56.1%). Conclusions: We concluded that AAMAD is an effective oral appliance for the majority of OSA patients.