• 제목/요약/키워드: Reduction Ratio in Height

검색결과 189건 처리시간 0.025초

Physiological Response to Salinity Stress of Japonica/Indica Lines Tolerant to Salt at Seedling Stage

  • Ko, Jong-Cheol;Lee, Kyu-Seong;Kim, Ki-Young;Choi, Weon-Young;Kim, Bo-Kyung;Shin, Woon-Cheol;Ko, Jae-Kwon;Yum, Song-Joong
    • 한국육종학회지
    • /
    • 제43권5호
    • /
    • pp.391-398
    • /
    • 2011
  • Physiological responses to salinity stress were evaluated in six rice genotypes differing in their tolerance to salinity at the seedling stage. Susceptible genotypes ('Dongjingbyeo', 'Hwayeongbyeo', and 'IR29') showed salt injury symptoms (mean 8.8) and higher visual score under salt stress than that of tolerant ones ('Pokkali', 'IR74009', and 'IR73571'). As salinity affects growth and physiological parameters, the six genotypes thus showed significant reduction because of salt stress. Tolerant Japonica/Indica bred lines ('IR74009', 'IR73571') showed lower reduction, 33.9%, 34.5%, and 50%, respectively, in plant seedling height, dry shoot weight and dry root weight than those of the susceptible Japonica varieties ('Dongjingbyeo', 'Hwayeongbyeo'), and the highest reduction under salt stress was observed in dry root weight, followed by dry shoot weight and seedling height, respectively. Shoot $Na^+$ concentration of IR74099 and IR73571 was lower than that of the susceptible varieties, 'Dongjinbyeo' and 'Hwayeongbyeo'. There were no significant differences among genotypes in root $Na^+$ concentration. Shoot $K^+$ concentration showed a reverse tendency compared to shoot $Na^+$ concentration. IR74009 and IR73571 had considerably lower ratio compared to 'Dongjinbyeo' and 'Hwayeongbyeo' in $Na^+/K^+$ ratio of their shoot and was not different the tolerant check, 'Pokkali'.

과도한 하안면 고경을 동반하는 하악전돌증환자의 하악골 후퇴술과 이부 감소 성형술식에 관한 연구 (A study on the mandibular setback osteotomy and reduction genioplasty in mandibular prognathism with long anterior facial height)

  • 장영일;임동혁;서정훈;김태우
    • 대한치과교정학회지
    • /
    • 제30권3호
    • /
    • pp.343-355
    • /
    • 2000
  • 본 연구는 과도한 하안면 고경을 동반하는 하악전돌증 환자의 악교정수술시 하악골후퇴 술과 이부 감소 성형술을 동시에 시행한 경우의 경조직과 연조직의 변화에 대해 살펴보고, 그 상관성을 평가하여 향후 진단시 보조자료로서 사용하고자 시행되었다. 골격성 III급 부정 교합으로 진단되어 술전 교정치료를 받고 하악골 후퇴술만을 시행한 성인 환자 20명을 대조군(A군)으로, 안모의 수평적 및 수직적 부조화가 심한 골격성 III급 부정교합으로 진단되어 술전 교정치료를 받고 하악골 후퇴술과 이부 감소 성형술을 함께 시행한 성인 환자 20명을 실험군(B군)으로 하였다. 두 군의 경조직 변화에 대한 연조직 변화 양상과, 경조직 변화에 따른 연조직의 이동 비율을 비교 분석하여 다음과 같은 결론을 얻었다. 1. A, B군 모두에서 경조직의 후방 이동과 하안면 하부 2/3의 연조직(Ils, Pog', Me')의 수평적 변화는 높은 상관성을 보였으며, B군에서는 A군에서보다 Ls, Stm, Li의 수평적 변화에도 중등도 이상의 상관성을 보였다. 2. B군의 경조직의 수직 이동에 따른 연조직의 수직적 변화의 상관성은 Point B-Ils, Me-Me'을 제외하고는 A군보다 적은 것으로 나타났다. 3. 경조직의 변화에 대한 연조직의 변화율을 비교해 보면, B군의 경우Pog'의 후방이동 비율이 A군에서보다 적게 나타났고, B군의 Ils, Pog', Me'의 상방이동 비율은 각각 32%, 54%, 60%로 나타났다. 4. 안면의 수직 고경에 대해서는 A, B군 모두에서 하안면 고경의 유의한 감소로 전안면 고경에 대한 하안면 고경의 비율이 감소하였으나, B군에서는 하안면 상부 1/3(Sn-Stm)의 비율은 변화 양상이 유의성있게 나타나지 않았다. 5. 이부 감소 성형술은 하악후퇴술과 함께 시행시 하안면 상부 1/3(Sn-Stm)의 안모비율에 대한 변화가 적고, 하안면 하부 2/3(St-Me')의 고경을 감소시킬 수 있는 술식이다.

  • PDF

Aerodynamics of tapered and set-back buildings using Detached-eddy simulation

  • Sharma, Ashutosh;Mittal, Hemant;Gairola, Ajay
    • Wind and Structures
    • /
    • 제29권2호
    • /
    • pp.111-127
    • /
    • 2019
  • The tapered and set-back type of unconventional designs have been used earlier in many buildings. These shapes are aerodynamically efficient and offer a significant amount of damping against wind-induced forces and excitations. Various studies have been conducted on these shapes earlier. The present study adopts a hybrid approach of turbulence modelling i.e., Detached-eddy Simulation (DES) to investigate the effect of height modified tapered and set-back buildings on aerodynamic forces and their sensitivity towards pressure. The modifications in the flow field around the building models are also investigated and discussed. Three tapering ratios (T.R.=(Bottom width- Top width)/Height) i.e., 5%, 10%, 15% are considered for tapered and set-back buildings. The results show that, mean and RMS along-wind and across-wind forces are reduced significantly for the aerodynamically modified buildings. The extent of reduction in the forces increases as the taper ratio is increased, however, the set-back modifications are more worthwhile than tapered showing greater reduction in the forces. The pressure distribution on the surfaces of the buildings are analyzed and in the last section, the influence of the flow field on the forces is discussed.

날개형 및 격막형 배플을 이용한 유체저장탱크 내부의 슬로싱 저감 연구 (A Study on the Reduction of the Sloshing of Storage Tank Using Wing and Diaphragm Baffle)

  • 이영신;김현수;이재형;김영완;고성호
    • 대한기계학회논문집A
    • /
    • 제27권12호
    • /
    • pp.2039-2046
    • /
    • 2003
  • Storage tank filled with fluid has unique dynamic characteristics compared to general structures, due to the interaction between fluid and structure. The oscillation of the fluid surface caused by external forces is called sloshing, which occurs in moving vehicles with contained liquid masses, such as trucks, railroad cars, aircrafts, and liquid missles. In this study, the evaluation method for the reduction of sloshing, the optimized size and location of wing and diaphragm baffles are suggested based on the experimental results. The experimental device can simulate the translation motion. A rectangular tank and various baffles are fabricated to study on the sloshing characteristics. The forces measured using the load cell at tank wall and those are compared with each other through the Fourier transformation for various conditions. The study of the sloshing of the rectangular tank equipped with baffles is conducted under the same conditions with non-baffled rectangular tank experiment. From the experimental results, the sloshing reduction effect by the baffles is observed. In conclusion in case of diaphragm baffles, the optimized size ratio of the width of baffle to the water height is 0.44 and the installation location has no effect to the damping of sloshing. In case of wing baffles, the optimized size ratio of the width of baffle to the length of a rectangular tank is 0.1 and the optimized location ratio of the baffle to the water height is 0.9.

열에너지 저장용 암반 공동의 최적 종횡비 결정을 위한 역학적 안정성 해석 (Mechanical Stability Analysis to Determine the Optimum Aspect Ratio of Rock Caverns for Thermal Energy Storage)

  • 박도현;류동우;최병희;선우춘;한공창
    • 터널과지하공간
    • /
    • 제23권2호
    • /
    • pp.150-159
    • /
    • 2013
  • 일반적으로 열저장소의 종횡비(폭에 대한 높이의 비)가 커짐에 따라 저장된 열에너지의 성층화가 높게 유지될 수 있는 것으로 알려져 있다. 따라서 열저장소의 열적 성능을 높이기 위해서는 저장소 종횡비를 크게 설정하는 것이 유리할 것이다. 그러나 종횡비의 증가에 따라 저장소의 폭에 비해 높이가 커지고, 이는 열저장소의 구조적 안정성 측면에서 불리하게 작용할 수 있으므로 저장소의 최적 종횡비 결정시 열적 성능 분석과 더불어 역학적 안정성에 대한 정량적인 분석이 수행되어야 할 것이다. 본 연구에서는 지하 열에너지 저장을 위한 사일로형 암반공동의 종횡비 변화에 따른 역학적 안정성을 수치해석적으로 조사하였다. 적용한 종횡비는 1-6의 범위이었고, 전단강도 감소기법에 의한 안전율을 토대로 암반공동의 역학적 안정성을 평가하였다. 종횡비별 안정성 분석 결과, 암반공동의 종횡비가 증가함에 따라 안전율이 감소하는 경향을 보였으며, 주변 암반의 측압계수가 안정성에 미치는 영향이 큰 것으로 분석되었다. 또한 동일한 암반특성 및 종횡비 조건에서 암반공동의 규모(저장 용량)가 줄어듦에 따라 안정성이 향상되는 것으로 나타나, 큰 규모의 단일 암반공동을 소규모의 다중 암반공동으로 분할함으로써 높은 종횡비의 암반공동 설계가 가능한 것을 알 수 있었다.

채광 및 차음성능을 고려한 초등학교 교실의 환경계획적 연구 (A Study on the Environmental Design of the classroom in Elementary Schools with Particular Reference to Natural Lighting and Sound Insulation Performance)

  • 손창환;최영준;이경회
    • 교육시설
    • /
    • 제4권2호
    • /
    • pp.13-20
    • /
    • 1997
  • The total evaluation of educational environment is needed with the rapid growth of the number of students. Especially it is very important to evaluate the physical environment of the classroom in elementary schools where the students spend their whole school life. This study aims to evaluate the daylighting and sound insulation performance of the classroom in elementary school, considering factors such as ceiling height and Wi/Wa (Window/Wall) ratio and then to plan the classroom. Analytic results of the daylighting and sound insulation performance show that the optimum Wi/Wa ratio is $35{\sim}45%$. Reduction of the ceiling height from 3.3m has little influence on the distribution of the indoor daylight factor and sound insulation performance

  • PDF

터빈 동익 컷백스퀼러팁 하류에서의 3차원 유동 및 압력손실 (Three-Dimensional Flow and Aerodynamic Loss Downstream of Turbine Rotor Blade with a Cutback Cavity Squealer Tip)

  • 김선웅;이상우
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.48-54
    • /
    • 2011
  • The effect of channel cutback on three-dimensional flow fields and aerodynamic losses downstream of a cavity squealer tip has been investigated in a turbine rotor cascade for the squealer rim height-to-chord ratio and tip gap height-to-chord ratio of $h_{st}/c$ = 5.51% and h/c = 2.0% respectively. The cutback length-to-camber ratio is changed to be $CB/c_c$ = 0.0, 0.1, 0.2 and 0.3. The results show that longer cutback delivers not only stronger secondary flow but also higher aerodynamic loss in the tip leakage vortex region, meanwhile it leads to lower aerodynamic loss in the passage vortex region. The discharge of cavity fluid through the cutback opening provides a beneficial effect in the reduction of aerodynamic loss, whereas there also exists a side effect of aerodynamic loss increase due to local wider tip gap near the trailing edge. With increasing $CB/c_c$ from 0.0 to 0.3, the aerodynamic loss coefficient mass-averaged all over the measurement plane tends to increase slightly.

Changes in Serum Biochemical Markers of Bone Cell Activity in Growing Thoroughbred Horses

  • Inoue, Yoshinobu;Asai, Y.;Ohmori, H.;Fujii, H.;Matsui, T.;Yano, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권11호
    • /
    • pp.1632-1637
    • /
    • 2006
  • We studied the changes in biochemical markers of bone metabolism in growing Thoroughbred horses. Serum osteocalcin (OC), as a marker for bone formation, and carboxy-terminal propeptide of type-I collagen (PICP), as a marker for bone formation, carboxy-terminal telopeptide of type-I collagen (ICTP), as a marker for bone resorption, were determined in nine clinically healthy horses from 3 d to 17 mo of age. The BW and withers height (WH) increased during the study. On the other hand, a rapid reduction in body weight gain (BWG) was observed between 1 mo and 9 mo of age and a rapid reduction in withers height gain was observed between 1 mo and 5 mo of age. The serum markers decreased significantly with increasing age. In particular, dramatic changes in serum markers occurred between 3 d to 1 wk and 5 to 7 mo of age in these horses, which suggests that bone turnover rapidly decreased after birth. On the other hand, the ratio of PICP to ICTP decreased through the experiment. This result suggests that the reduction in bone formation exceeded that of bone resorption. There was a significant correlation between markers and growth parameters, except for the correlation between PICP and BWG on single linear regression analysis. Serum OC and ICTP were affected by the WH in multiple linear regression analysis. These results indicated that the age-related variation in serum biochemical markers of bone metabolism reflected bone growth, but neither BW nor BWG. Therefore, we consider that changes in bone modeling are the major factor affecting the levels of serum biochemical markers by 17 mo of age in horses.

Effect of trunk length on the flow around a fir tree

  • Lee, Jin-Pyung;Lee, Eui-Jae;Lee, Sang-Joon
    • Wind and Structures
    • /
    • 제18권1호
    • /
    • pp.69-82
    • /
    • 2014
  • Flow around a small white fir tree was investigated with varying the length of the bottom trunk (hereafter referred to as bottom gap). The velocity fields around the tree, which was placed in a closed-type wind tunnel test section, were quantitatively measured using particle image velocimetry (PIV) technique. Three different flow regions are observed behind the tree due to the bottom gap effect. Each flow region exhibits a different flow structure as a function of the bottom gap ratio. Depending on the gap ratio, the aerodynamic porosity of the tree changes and the different turbulence structure is induced. As the gap ratio increases, the maximum turbulence intensity is increased as well. However, the location of the local maximum turbulence intensity is nearly invariant. These changes in the flow and turbulence structures around a tree due to the bottom gap variation significantly affect the shelter effect of the tree. The wind-speed reduction is increased and the height of the maximum wind-speed reduction is decreased, as the gap ratio decreases.

손상영역을 이용한 철근 콘크리트 보의 손상평가 (Damage Assessment of Reinforced Concrete Beams using Damage-area concept)

  • 노원균;심창수;김기봉;김현호;홍창국
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.647-650
    • /
    • 2004
  • This paper deals with the damage assessment of the concrete beam using Damage-area concept and the modulus of elasticity reduction of the beam was evaluated. Simply supported concrete beams were loaded at the mid-span. When the displacements from the tests were increased more than $10\%$ of the initial values, flexural cracks occured. Judging from the observed cracks, damaged area of the beams were assumed and the modulus of elasticity reduction using the smeared-cracking concept was estimated to minimize the error between the test results and analytical results. Main parameters for the assessment were height of the crack area, length of the crack area, position of the crack area and the modulus of elastic reduction ratio. In each stage, damaged elements and their stiffness reduction were estimated to minimized the error.

  • PDF