• Title/Summary/Keyword: Reduces load

Search Result 608, Processing Time 0.027 seconds

Time Dependent Thermal Load Analysis of the Building with an Airflow Window System (공기식 집열창 시스템이 설치된 건물의 동적부하 해석)

  • Cho, S.H.;Park, S.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.82-95
    • /
    • 1992
  • It has been known that the application of an airflow window system reduces the energy consumption compared with conventional double pane window in a building. But how to analyze thermal load in a building with an airflow window system has not been well known. so two kinds of method (Mode 1 and Mode 2) to analyze time dependent thermal load of the building with an airflow window system are presented in this study. The results of load analysis about the model building(total area : $4521m^2$, 3 floors) by Mode 2 show that the maximum cooling and heating load in a building with an airflow window system are decreased about 12-17% and about 19.5% than with double pane glass window, and yearly energy consumption with an airflow window system is saved about about 20% than with double pane glass window.

  • PDF

Modeling and Simulation of Efficient Load Balancing Algorithm on Distributed OCSP (분산 OCSP에서의 효율적인 로드 밸런싱 기법에 관한 모델링 및 시뮬레이션)

  • Choi Ji-Hye;Cho Tae Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.13 no.4
    • /
    • pp.43-53
    • /
    • 2004
  • The distributed OCSP (Online Certificate Status Protocol), composed of multiple responders, is a model that enhances the utilization of each responder and reduces the response time. In a multi-user distributed environment, load balancing mechanism must be developed for the improvement of the performance of the whole system. Conservative load balancing algorithms often ignore the communication cost of gathering the information of responders. As the number of request is increased, however, fail to consider the communication cost may cause serious problems since the communication time is too large to disregard. We propose an adaptive load balancing algorithm and evaluate the effectiveness by performing modeling and simulation. The principal advantage of new algorithm is in their simplicity: there is no need to maintain and process system state information. We evaluated the quality of load balancing achieved by the new algorithm by comparing the queue size of responders and analyzing the utilization of these responders. The simulation results show how efficiently load balancing is done with the new algorithm.

  • PDF

Buckling behavior of composite cylindrical shells with cutout considering geometric imperfection

  • Heidari-Rarani, M.;Kharratzadeh, M.
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.305-313
    • /
    • 2019
  • Creating different cutout shapes in order to make doors and windows, reduce the structural weight or implement various mechanisms increases the likelihood of buckling in thin-walled structures. In this study, the effect of cutout shape and geometric imperfection (GI) is simultaneously investigated on the critical buckling load and knock-down factor (KDF) of composite cylindrical shells. The GI is modeled using single perturbation load approach (SPLA). First, in order to assess the finite element model, the critical buckling load of a composite shell without cutout obtained by SPLA is compared with the experimental results available in the literature. Then, the effect of different shapes of cutout such as circular, elliptic and square, and perturbation load imperfection (PLI) is investigated on the buckling behavior of cylindrical shells. Results show that the critical buckling load of a shell without cutout decreases by increasing the PLI, whereas increasing the PLI does not have a great impact on the critical buckling load in the presence of cutout imperfection. Increasing the cutout area reduces the effect of the PLI, which results in an increase in the KDF.

Upwind Finite Element Model for Suspended Sediment Transport

  • Noh, Joon-Woo
    • Journal of Wetlands Research
    • /
    • v.5 no.1
    • /
    • pp.67-78
    • /
    • 2003
  • The unsteady 2D convection and diffusion equation is solved numerically for the real-time simulation of suspended load propagation. The streamlined upwind scheme efficiently reduces numerical oscillations due to the high Peclet number in the convection dominant flow. By using the mixed boundary condition to express the external source terms or externally induced suspended load as a function of time in the algorithm, the model is capable of handling not only continuous load cases but also non-continuous suspended load influx. The suspended load transport modelwas verified using a case study for which an analytical exact solution is available and was applied to the real-time simulation of a suspended load influx case on the Mississippi River. The model algorithm can provide a framework upon which water quality as well as contaminant transport models can be built.

  • PDF

Design Recommendations of the Occupant Protection Systems Using Orthogonal Arrays (직교배열표를 이용한 승객보호장구의 설계)

  • 임재문;박경진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.8
    • /
    • pp.208-215
    • /
    • 1999
  • Using the orthogonal arrays and the occupant analysis software based on the multi-body dynamics , two interactive design algorithms are proposed to improve the initial design of the occupant protection systems. Algorithm 1 sequentially moves the narrow design space within the upper and the lower design limit. Algorithm 2 sequentially reduces the relatively wide design space. Each design algorithm is composed of two levels . The first level is to improve the characteristics of the crash performance considering the noise factors. In order to obtain the robust design, the second level reduces the variations the noise factors. In order to obtain the robust design, the second level reduces the variations due to the tolerance of the design variable. To utilize the algorithm 1, HIC(Head Injury Criterion) , 3 msec criterion value of the chest acceleration and the femur load decreased by 27.4%, 10.4% and 55.8%, respectively. To utilizer the algorithm 2 , the results decreased by 38.0%, 10.5% and 3.0% , respectively.

  • PDF

SW-VVVF System for High Efficiency Drive of Induction Motor (삼상 유도전동기의 고효율 운전을 위한 SW-VVVF 시스템에 관한 연구)

  • 유철로;이공희;이성룡
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.2
    • /
    • pp.93-99
    • /
    • 1989
  • This paper describes Sinusoidal Wave-Variable Voltage Variable Fequency (SW-VVVF) system for the high efficiency drive of a 3-phase induction motor. SW-VVVF system consists of a 3-phase 24-pulse converter and a SPWM inverter. The converter with additional 2 tap diode circuits in interphase reactor reduces harmonics in input current. The SPWM inverter consists of an improved PLL system and a V/F controller, which reduces harmonics in output current and performs a high efficiency algorithm by maintaining a constant slip frequency and compensating for the velocity variation of the induction motor with the change of load. Therefore, this system reduces harmonics in input and output currents, and also can drive an induction motor with high efficiency in an economical way. We have proved its utility through experiment.

  • PDF

A Experimental Study on Fatigue Behavior of Joints between RC and RSFC subjected to shear (강섬유 보강 철근콘크리트 전단이음부의 피로거동에 대한 실험적 연구)

  • 강보순
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.389-396
    • /
    • 2000
  • Fatigue behavior of shear joints between combined reinforced concrete(RC) and reinforced steel fiber concrete(RSFC) specimens has been experimentally investigated. Experimental parameters used are the amount of steel fiber and the type of shear joint. 6 specimens have been tested under static load, and 8 specimens have been subjected to the fatigue load in a range of 50% and 5 % of the ultimate static load. The purpose of this research is to propose an empirical formula for fatigue shear behavior of combined RC and RSFC structures on the basic of experimental result. It can be observed from experimental result that addition of steel fibers to concrete specimen increases the static ultimate load by approximately 25%, enhances the fatigue behavior, and also reduces vertical and lateral displacements at the shear joint for a given load cycle after the occurrence of first crack.

  • PDF

Effect of corner modifications on 'Y' plan shaped tall building under wind load

  • Sanyal, Prasenjit;Dalui, Sujit Kumar
    • Wind and Structures
    • /
    • v.30 no.3
    • /
    • pp.245-260
    • /
    • 2020
  • Wind load and responses are the major factors which govern the design norms of tall buildings. Corner modification is one of the most commonly used minor shape modification measure which significantly reduces the wind load and responses. This study presents a comparison of wind load and pressure distribution on different corner modified (chamfered and rounded) Y plan shaped buildings. The numerical study is done by ANSYS CFX. Two turbulence models, k-epsilon and Shear Stress Transport (SST), are used in the simulation of the building and the data are compared with the previous experimental results in a similar flow condition. The variation of the flow patterns, distribution of pressure over the surfaces, force and moment coefficients are evaluated and the results are represented graphically to understand the extent of nonconformities due to corner modifications. Rounded corner shape is proving out to be more efficient in comparing to chamfered corner for wind load reduction. The maximum reduction in the maximum force and moment coefficient is about 21.1% and 19.2% for 50% rounded corner cut.

Study on the Fatigue Behavior of a Joint between RC and SFRC Subjected to Shear (철도하중에 대한 철근 콘크리트와 강섬유 보강 철근 콘크리트 전단이음부의 피로거동에 관한 실험적 연구)

  • 강보순
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.4
    • /
    • pp.194-202
    • /
    • 2000
  • Fatigue behavior of shear joints between the combined reinforced concrete(RC) and the reinforced steel fiber concrete(SFRC) specimens has been experimentally investigated. Experimental parameters used are the amount of steel fiber and the type of shear joint. Six specimens have been tested under static load, and eight specimens have been subjected to the fatigue load in a range of 50 % and 5 % of the ultimate static load. The purpose of this research is to propose an empirical formula for fatigue shear behavior of the combined RC and SFRC structures on the basis of experimental result. It can be observed from experimental results that addition of steel fibers to concrete specimen increases the static ultimate load by approximately 25 %, enhances the fatigue behavior, and also reduces vertical and lateral displacements at the shear joint for a given load cycle after the occurrence of first crack.

  • PDF

Comparison of Intelligent Charging Algorithms for Electric Vehicles to Reduce Peak Load and Demand Variability in a Distribution Grid

  • Mets, Kevin;D'hulst, Reinhilde;Develder, Chris
    • Journal of Communications and Networks
    • /
    • v.14 no.6
    • /
    • pp.672-681
    • /
    • 2012
  • A potential breakthrough of the electrification of the vehicle fleet will incur a steep rise in the load on the electrical power grid. To avoid huge grid investments, coordinated charging of those vehicles is a must. In this paper, we assess algorithms to schedule charging of plug-in (hybrid) electric vehicles as to minimize the additional peak load they might cause. We first introduce two approaches, one based on a classical optimization approach using quadratic programming, and a second one, market based coordination, which is a multi-agent system that uses bidding on a virtual market to reach an equilibrium price that matches demand and supply. We benchmark these two methods against each other, as well as to a baseline scenario of uncontrolled charging. Our simulation results covering a residential area with 63 households show that controlled charging reduces peak load, load variability, and deviations from the nominal grid voltage.