• Title/Summary/Keyword: Reduced flow rate

Search Result 776, Processing Time 0.035 seconds

Preparation of Hydrophobic Porous PVDF Membrane and Application for Membrane Distillation (소수성 다공질 PVDF 중공사 분리막 제조 및 막증류 적용)

  • Min, Ji Hee;Park, Min Soo;Kim, Jinho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.240-248
    • /
    • 2014
  • Porous PVDF hollow fiber membranes were prepared by hybrid process of TIPS(thermally induced phase separation) and stretching for membrane distillation. The tests were conducted to investigate that permeability of the membrane could be enhanced by reducing membrane wall thickness. During fiber spinning, dope discharge rate from nozzle was reduced and flow rate of bore fluid increased to make the wall thickness thinner. As dope discharge rate from nozzle was reduced and flow rate of bore fluid increased, the membrane wall thickness was reduced. As a result, air permeability, water permeability and vapor permeability of the membranes increased.

Effect of Flow Direction on Two-Phase Flow Distribution of Refrigerants at a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.717-727
    • /
    • 2006
  • The present study experimentally investigated the effect of flow direction and other flow parameters on two-phase flow distribution of refrigerants at a T-junction, and also suggested a prediction model for refrigerant in a T-junction by modifying previous model for air-water flow. R-22, R-134a, and R-410A were used as test refrigerants. As geometric parameters, the direction of the inlet or branch tube and the tube diameter ratio of branch to inlet tube were chosen. The measured data were compared with the values predicted by the models developed for air-water or steam-water mixture in the literature. We propose a modified model for application to the reduced T-junction and vertical tube orientation. Among the geometric parameters, the branch tube direction showed the biggest sensitivity to the mass flow rate ratio for the gas phase, while the inlet quality showed the biggest sensitivity to the mass flow rate ratio among the inlet flow parameters.

DEVELOPMENT OF AN IMPROVED FARE TOOL WITH APPLICATION TO WOLSONG NUCLEAR POWER PLANT

  • Lee, Sun Ki;Hong, Sung Yull
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.257-264
    • /
    • 2013
  • In Canada Deuterium Uranium (CANDU)-type nuclear power plants, the reactor is composed of 380 fuel channels and refueling is performed on one or two channels per day. At the time of refueling, the fluid force of the cooling water inside the channel is exploited. New fuel added upstream of the fuel channel is moved downstream by the fluid force of the cooling water, and the used fuel is pushed out. Through this process, refueling is completed. Among the 380 fuel channels, outer rows 1 and 2 (called the FARE channel) make the process of using only the internal fluid force impossible because of the low flow rate of the channel cooling water. Therefore, a Flow Assist Ram Extension (FARE) tool, a refueling aid, is used to refuel these channels in order to compensate for the insufficient fluid force. The FARE tool causes flow resistance, thus allowing the fuel to be moved down with the flow of cooling water. Although the existing FARE tool can perform refueling in Korean plants, the coolant flow rate is reduced to below 80% of the normal flow for some time during refueling. A Flow rate below 80% of the normal flow cause low flow rate alarm signal in the plant operation. A flow rate below 80% of the normal flow may cause difficulties in the plant operation because of the increase in the coolant temperature of the channel. A new and improved FARE tool is needed to address the limitations of the existing FARE tool. In this study, we identified the cause of the low flow phenomena of the existing FARE tool. A new and improved FARE tool has been designed and manufactured. The improved FARE tool has been tested many times using laboratory test apparatus and was redesigned until satisfactory results were obtained. In order to confirm the performance of the improved FARE tool in a real plant, the final design FARE tool was tested at Wolsong Nuclear Power Plant Unit 2. The test was carried out successfully and the low flow rate alarm signal was eliminated during refueling. Several additional improved FARE tools have been manufactured. These improved FARE tools are currently being used for Korean CANDU plant refueling.

An effect of design parameters of water injection silencer on the characteristics of noise generated by Liquid Rocket Engine (물분사형 소음기의 설계 변수가 액체로켓엔 소음특성에 미치는 영향)

  • Park, Hee-Ho;Cho, Byoung-Sun;Kim, Yoo;Ji, Pyung-Sam;Kim, Seon-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.2
    • /
    • pp.83-87
    • /
    • 1998
  • To reduce the supersonic jet noise from the liquid rocket engine, water injetion silencers were designed and tested. Test variables were the mass flow rate of water jet, the length of primary pipe and the diameter of expansion pipe. Followings are the results of this study. 1. From the same mass flow rate of water, longer primary pipe was more effective to reduce the noise. 2. Noise level was significantly reduced with increasingly water flow rate. 3. The optimum water flow rate was 10~12 times of the propellant flow rate. 4. By installing expansion pipe, noise level was reduced approximately 30㏈ compared to without expansion pipe

  • PDF

Effect of Polyporus umbellatus Fries on the Renal Function of Dog (저분(猪芬)의 개의 신장기능(腎臟機能)에 미치는 영향(影響))

  • Kang, Hyung-Yong;Ko, Suk-Tai
    • Journal of Pharmaceutical Investigation
    • /
    • v.5 no.1
    • /
    • pp.28-40
    • /
    • 1975
  • Polyporus would used as diuretics. Then, for the purpose of experimentally certifying the above mention, the effect on the renal function of dog was investigated, utilizing clearance technique. Water and alcohol extracts, when injected intravenously, produced significant increases of urinary sodium and potassium, osmolar and free water clearances, and urine flow, while glomerular filtration rate and renal plasma flow remained unchanged. During diuresis produced by furosemide, addition of water extract reduced the action of furosemide and markedly renal plasma flow. It would appear that these compounds are capable of action by a different mechanism or a different site. water extract, when infused directly into a renal artery, reduced the urine flow of experimental kidney as well as renal plasma flow, and the contralateral kidney exhibited diuresis, whereas amounts of sodium and potassium excreted in urine increased on both kidney. It is surmised from those observations that Polyporus induces diuresis by inhibition the reabsorptive mechanism of renal tubules through some endogeneous humoral substances, in addition, directly reduces the renal plasma flow.

  • PDF

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

  • Sung, Kun-Hyuk;Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.2
    • /
    • pp.119-126
    • /
    • 2009
  • A numerical analysis is performed to investigate the effect of rotation on the blood flow characteristics with four different angular velocities. The artery has a cylindrical shape with 50% stenosis rate symmetrically distributed at the middle. Blood flow is considered a non-Newtonian fluid. Using the Carreau model, we apply the pulsatile velocity profile at the inlet boundary. The period of the heart beat is one second. In comparison with no-rotation case, the flow recirculation zone (FRZ) contracts and its duration is reduced in axially rotating artery. Also wall shear stress is larger after the FRZ disappears. Although the geometry of artery is axisymmetry, the spiral wave and asymmetric flow occur clearly at the small rotation rate. It is caused that the flow is influenced by the effects of the rotation and the stenosis at same time.

Improvement of Gasoline Engine Performance by Modifying the Engine Cooling System (엔진 냉각계 개선을 통한 가솔린엔진의 성능 향상)

  • 류택용;신승용;이은현;최재권
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.3
    • /
    • pp.1-10
    • /
    • 1998
  • In this paper, we investigated the improvement of characteristics of knock, emission and fuel consumption rate by optimizing the location and size of water transfer holes in cylinder head gasket without change of engine water jacket design itself. The cooling system was modified in the direction of reducing the metal temperature in the head and increasing the metal temperature in the block. The optimization of water transfer holes in cylinder head gasket was obtained by "flow visualization test". The water transfer holes were concentrated in front side of the engine in order to reduce thermal boundary layer in the water jacket of No. 2 and No. 3 combustion changer in the cylinder head, which would have a large knock intensity, and increase thermal boundary layer in the water jacket of the cylinder block. When the modified coolant flow pattern was applied as proposed in this paper, the knock characteristic was improved. The spark timing was advanced up to 2$^{\circ}$ in low and middle speed range at a full load. In addition, HC emission at MBT was reduced by 5.2%, and the fuel consumption rate was decreased up to 1% in the driving condition of 2400 rpm and 250 KPa. However, since this coolant flow pattern mentioned in this paper might deteriorate the performance of vehicle cooling system due to the coolant flow rate reduction, a properly optimized point should be obtained. obtained.

  • PDF

The Application of Direct Water Quenching Process in Hot Stamping of Boron Steels (보론강 판재 핫스탬핑시 직수분사냉각 공정의 적용성)

  • Park, Hyeon Tae;Kwon, Eui Pyo;Im, Ik-Tae
    • Korean Journal of Materials Research
    • /
    • v.29 no.12
    • /
    • pp.818-824
    • /
    • 2019
  • In this study, the direct water quenching technique is applied to validate the applicability of direct water quenching as a cooling method in the hot stamping process of 3.2 mm thick boron steel sheet. Cooling performance of conventional die quenching and direct water quenching is compared. Higher cooling rate is obtained by hot stamping with direct water quenching compared to die quenching. As the flow rate of cooling water increases, the cooling rate increases, and a high cooling rate of 71 ℃/s is achieved under flow rate conditions of 0.8 L/min. Through direct water quenching, the cooling time required for sufficient cooling of the sheet is reduced. Full martensitic microstructure is obtained under flow rate condition of 0.8 L/min. Hardness increases with increasing flow rate. From these results, it is verified that the direct water quenching is applicable to the hot stamping of thick boron steel sheet.

Improvement in flow and noise performances of small axial-flow fan for automotive fine dust sensor (차량용 미세먼지 센서용 소형 축류팬의 유동과 소음 성능 개선)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Inhiug Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.7-15
    • /
    • 2023
  • Recently, as interest in air quality in vehicles increases, the use of fine dust detection sensors for air quality measurement is becoming common. An axial-flow fan is inserted in the fine dust sensor installed in the air conditioning system in the vehicle to prevent dust from sinking directly on the sensor. When the sensor operates, the flow noise caused by the rotation of the axial-flow fan acts as a major noise source of the fine dust sensor. flow noise is recognized as one of the product competitiveness of fine dust sensors. In this study, the noise was gradually reduced at the same flow rate by improving the flow performance of the small axial flow fan. First, a virtual fan performance tester consisting of about 20 million grids was developed to analyze the aerodynamic performance of the target small axial-flow fan. In addition, the flow field was simulated by using compressible Large Eddy Simulation for direct computation of flow noise as well as high-accurate prediction of flow rate. The validity of numerical method are confirmed through the comparison of predicted results with experimental ones. After the effects of pitch angle on flow performance were analyzed using the verified numerical method, the pitch angle was determined to maximize the flow rate. It was found that the flow rate was increased by 8.1 % and noise was reduced by 0.8 dBA when the axial-flow fan with the optimum pitch angle was used.

A Convergence Study through Flow Analysis of Automotive Side Mirror (자동차 사이드미러의 유동 해석을 통한 융합연구)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.9
    • /
    • pp.161-166
    • /
    • 2019
  • This study examines the flows near the different side mirrors by analyzing the flow due to air resistance at A, B and C models of automotive side mirrors. Model A is a square-shaped side-mirror. Model B is a triangular side-mirror and model C is an oval-shaped side-mirror. The air resistance of the side-mirror while driving is reduced and the automotive power can be reduced by changing the design of automotive side-mirror. As analysis result, as the pressure of air resistance against side mirror becomes larger, it can be seen that the air flow rate becomes great. Therefore, it can be estimated that the smaller the pressure of air resistance, the smaller the flow rate and the better the air flow. Therefore, it can be acknowledged that model B is the best model. As the design data of the automotive side mirror obtained on the basis of this study result are utilized, the esthetic sense can be shown while driving a car at real life.