• 제목/요약/키워드: Reduced Cost

Search Result 2,633, Processing Time 0.028 seconds

A New High Efficiency PWM Single-Switch Isolated Converter

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.301-309
    • /
    • 2007
  • The flyback converter is one of the most attractive isolated converters in small power applications because of its simple structure. However, it suffers from high device stress, large transformer size, and high voltage stress across its switch and diode. To solve these problems a new cost-effective PWM single-switch isolated converter is proposed. The proposed converter has no output filter inductor, reduced voltage stress on the secondary devices, and reduced transformer size. Moreover, the switch turn-off loss is reduced and no dissipative snubber across the secondary diode is required. Therefore, it features a simple structure, a low cost, and high efficiency. The operational principle and characteristics of the proposed converter are presented and compared with the flyback converter and then verified experimentally.

A New High Efficiency PWM Single-Switch Isolated Converter

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.289-292
    • /
    • 2007
  • The flyback converter is one of the most attractive isolated converters in small power applications because of its simple structure. However, it suffers from high device stress, large transformer size, and high voltage stress across switch and diode. To solve these problems a new cost-effective PWM single-switch isolated converter is proposed. The proposed converter has no output filter inductor, reduced voltage stress on the secondary devices, and reduced transformer size. Moreover, the switch turnoff loss is reduced and no dissipative snubber across the secondary diode is required. Therefore, it features a simple structure, low cost, and high efficiency. The operational principle and characteristics of proposed converter are presented compared with flyback converter and verified experimentally.

  • PDF

A study on automatic selection of optimal cutting condition on machining in view of economics (기계가공시 분당가공비를 고려한 최적 절삭 조건에 관한 연구)

  • 이길우;이용성
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.113-126
    • /
    • 1992
  • Recently the multi-kind, small-amount manufacturing system has been replacing the mass manufacturing system, and domestic machining inustry also is eager to absorb the new technology because of its high productivity and cost reduction. The optimization of the cutting condition has been a vital problem in the machining industry, which would help increase the productivity and raise the international competitiveness. It is intended in this study to investigate the machining costs per unit time which is essential to the analysis of the optimal cutting condition, to computer the cutting speed that lead to the minimum machining costs and the maximum production to suggest the cutting speed range that enables efficient speed cutting, and to review the machining economy in relation to cutting depth and feed. Also considered are the optimal cutting speed and prodution rated in rrelation with feed. It is found that the minimum-cost cutting speed increases and the efficient cutting speed range is reduced as machining cost per unit time increases since the cutting speed for maximum production remains almost constant. The machining cost is also lowered and the production rate increases as the feed increases, and the feed should be selected to satisfy the required surface roughness. The machining cost and production rate are hardly affected by the cutting depth if the cutting speed stays below 100m/min, however, they are subject to change at larger cutting depth and the high-efficient speed range also is restricted. It can be established an adaptive optimal cutting conditions can be established in workshop by the auto-selection progam for optimal operation. It is expected that this method for choosing the optimal cutting conditions might contribute to the improvement of the productivity and reduced the cost. It is highly recommended to prepare the optimal cutting conditionthus obtained for future use in the programing of G-function of CNC machines. If proper programs that automatically select the optimal cutting conditions should be developed, it would be helpful to the works being done in the machine shops and would result in noticeable production raise and cost reduction.

  • PDF

Case Report on the Activities for Cost Reduction and Performance Improvement in the Central Supply Room in A University Hospital (종합병원의 비용절감과 업무개선을 위한 중앙공급실의 활동)

  • Song, Kyu Nam;Song, Sun Ok;Hwang, Un Soon;Koo, Bon Up;Choi, Hye Sook;Lee, Sang Yun
    • Quality Improvement in Health Care
    • /
    • v.6 no.1_2
    • /
    • pp.150-160
    • /
    • 1999
  • Background : Because hospitals had to faced with financial hardship, we have to have more effective hospital management. In this study, we tried to improve job performance and to reduce cost maintaining safety in fields of patients care. Methods : Central Supply Room(CSR) staffs taught strategy of material cost reduction to middle level managers and staffs 14 times. All staffs and voluntary service workers, working in 33 nursing units, participated in this activity. We developed questionnaire to check the degree of participate in cost reduction activity and job performance in CSR, and quality improvement in the wards. Two hundred questionnaires were distributed and 197 returned. Results : Because CSR staffs developed new items and every item was managed at each department, stocks of each department were reduced. Overall, by comparing before and after cost reduction activity, almost 1.2 billion won reduced for one year. Staffs' loyalty and spirits of cost reduction were improved by changing clothes and duty environment. Furthermore, these activity improved patients' satisfaction. Conclusion : We suggest that CSR activity in a university hospital contributes to improve job performance and to reduce cost without any problem in patient care.

  • PDF

A Linkage Method for the Life Cycle Cost Breakdown Structure through an Analysis of Boundary Conditions (경계조건 분석을 통한 LCCBS 연계방안)

  • Jeong, Jae-Hyuk;Kim, Tae-Hui
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.4
    • /
    • pp.321-332
    • /
    • 2013
  • Costs and expenses are intertwined and incurred throughout an entire construction project, even from the pre-construction phase, and each phase has a different impact on the life cycle cost (LCC). However, the cost breakdown structure (CBS) is different in each phase of a building construction project, which makes it hard to reasonably calculate construction cost. For this reason, the boundary conditions were analyzed in this study based on the life cycle cost break structure (LCCBS). In addition, breakdown factors were analyzed based on the boundary conditions to derive a linkage method. The validity of the linkage method was verified through application to actual construction projects. Through the analysis, it was found that the problem of items being left out was reduced by more than 97.2 percent, and the work was done an average of 6 hours faster compared to the conventional method. It is expected that by applying the new LCC system, LCC will be both reduced and calculated in a more efficient manner.

Economic analysis on the applications of shipboard LED luminaires (선박용 LED 등기구의 적용에 따른 경제성 분석)

  • Park, Seo-Jun;Byeon, Sung-Hwan;Kim, Sun-Jae;Park, Kyoung-Soo;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.342-347
    • /
    • 2016
  • This paper dealt with the economic analysis on the application of shipboard LED (Light Emitting Diode) luminaires to replace incandescent and fluorescent lamps, which account for over 80 % of light source on a training or naval vessel. The rates of savings achieved in the power consumption, initial investment, maintenance cost, and fuel cost were analyzed. The break-even points and the $CO_2$ emissions were also calculated. For the training vessel, the initial investment was increased by 3.8 times, while the maintenance cost over five years was reduced by 51 %. When 40 %, 50 %, and 60 % of luminaires were turned on, the calculated break-even points were 11 months, 9 months, and 7 months, respectively. On the other hand, the initial investment was increased by 3.5 times while the maintenance cost over five years was saved by 55 % for the naval vessel. The break-even points were calculated as 15 months, 12 months, and 10 months, respectively. Moreover, the $CO_2$ emissions of the training and the naval vessels were reduced by 69 % and 65 %, respectively. From the results, it was revealed that the maintenance cost can be reduced by more than 50 %, and that the power consumption, fuel cost, and $CO_2$ emissions can be reduced by more than 60 % if LED luminaires are used on two types of vessels.

Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1015-1024
    • /
    • 2015
  • This paper introduces a low cost, high efficiency, high performance three-phase unified power quality conditioner (UPQC) by using four-switch three-phase inverters (FSTPIs) and an extra capacitor in the shunt active power filter (APF) side of the UPQC. In the proposed UPQC, both shunt and series APFs are developed by using FSTPIs so that the number of switching devices is reduced from twelve to eight devices. In addition, by inserting an additional capacitor in series with the shunt APF, the DC-link voltage in the proposed UPQC can also be greatly reduced. As a result, the system cost and power loss of the proposed UPQC is significantly minimized thanks to the use of a smaller number of power switches with a lower rating voltage without degrading the compensation performance of the UPQC. Design of passive components for the proposed UPQC to achieve a good performance is presented in detail. In addition, comparisons on power loss, overall system efficiency, compensation performance between the proposed UPQC and the traditional one are also determined in this paper. Simulation and experimental studies are performed to verify the validity of the proposed topology.

A research on the design parameters for a double-transmission main system for sustainable water supply (이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구)

  • Hyun, Inhwan;Hong, Juneui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.129-138
    • /
    • 2013
  • Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

Estimating the economic effectiveness of LED fishing light systems for the squid jigging fishery (오징어 채낚기어업의 LED 집어시스템 도입에 따른 경제성 분석)

  • Seo, Ju-Nam;An, Heui-Chun;Kim, Do-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.4
    • /
    • pp.346-351
    • /
    • 2012
  • The fuel cost of fishing lights for squid jigging fishing vessels takes about 30% of total fishing costs and over 65% of total fuel costs, which indicates the necessity of development of cost-reducing and high efficient fishing light system. This study aimed to analyze the economic effectiveness of LED fishing light systems in combination with metal halide lamp for the squid jigging fishery. Analytical results showed that the level of fishing profits of vessels using LED lights could be different with those of vessels using metal halide lights. That is, when a fuel cost could be reduced by 30%, fishing profits of vessels using LED lights might be the same as those of vessels using metal halide lights, and fishing profits of vessels using LED lights could be higher than those of vessels using metal halide lights when a fuel cost could be reduced by 50%.