• 제목/요약/키워드: Rectifying control

검색결과 38건 처리시간 0.025초

Design and Analysis of High-Speed Unmanned Aerial Vehicle Ground Directional Rectifying Control System

  • Yin, Qiaozhi;Nie, Hong;Wei, Xiaohui;Xu, Kui
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권4호
    • /
    • pp.623-640
    • /
    • 2017
  • The full nonlinear equations of an unmanned aerial vehicle ground taxiing mathematical dynamic model are built based on a type of unmanned aerial vehicle data in LMS Virtual.Lab Motion. The flexible landing gear model is considered to make the aircraft ground motion more accurate. The electric braking control system is established in MATLAB/Simulink and the experiment of it verifies that the electric braking model with the pressure sensor is fitted well with the actual braking mechanism and it ensures the braking response speediness. The direction rectification control law combining the differential brake and the rudder with 30% anti-skid brake is built to improve the directional stability. Two other rectifying control laws are demonstrated to compare with the designed control law to verify that the designed control is of high directional stability and high braking efficiency. The lateral displacement increases by 445.45% with poor rectification performance under the only rudder rectifying control relative to the designed control law. The braking distance rises by 36m and the braking frequency increases by 85.71% under the control law without anti-skid brake. Different landing conditions are simulated to verify the good robustness of the designed rectifying control.

3-Phase Quasi-Resonant Inverter의 동작모드 확장 (Expansion of Operating Mode of 3-Phase Quasi-Resonant DC Link Inverter)

  • 양순배;이진우;박민호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-271
    • /
    • 1990
  • This paper describes a 3-Phase Quasi-Resonant DC Link Inverter (3-phase QRI), which has two operating modes, ie. inverting mode and rectifying mode. First the 3-Phase QRI is simplified and the resonant circuit is analyzed in comparison with two resonant DC-to-DC converters. This analysis shows that the maximum voltage of resonant capacitor is limited to twice the input voltage irrespective of operating modes. A new simple control method in rectifying mode is suggested, which does not require any other element in power circuit. The characteristic of 3-Phase Quasi Resonant Inverter has been verified by simulation using the proposed control method.

  • PDF

통합공정관리에서 재수정 절차 (A Readjustment Procedure after Signalling in the Integrated Process Control)

  • 박창순;이재헌
    • Communications for Statistical Applications and Methods
    • /
    • 제16권3호
    • /
    • pp.429-436
    • /
    • 2009
  • 통합공정관리의 기본절차는 잡음이 내재하는 공정에 수정조치를 취하여 공정 편차를 백색잡음으로 전환하도록 하여 공정제곱편차를 최소화하게 된다. 이러한 수정활동 중 공정에 이상원인이 발생하면 관리도를 통하여 이를 탐지하고 제거하게 된다. 수정된 공정은 이상원인 발생 전에는 백색잡음이 되지만, 이상원인 발생 후에는 다양한 형태의 시계열 모형으로 변환하게 된다. 만일 수정된 공정을 탐지하여 이상원인의 신호가 있을 경우 교정활동을 통하여 이를 제거해야 하지만, 교정활동의 비용이 많이 발생하거나 또는 구조적으로 이를 제거할 수 없는 경우에는 이상원인의 효과를 감안하여 수정활동을 재조정해야 할 것이다. 이 논문에서는 공정모형으로 IMA(1,1) 모형을 가정하고 통합공정관리 절차를 수행하는 경우, 이상신호 발생 후 재수정 절차를 제안한다.

전파정류 방식의 X선 발생장치에서 조사선량 (Exposure Does of X-ray Generator on Full Wave Rectification Method)

  • 김태곤;김영표;천민우;이호식;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.138-138
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. I fabricated a high tension generator of a full-wave rectification type using a LC resonant inviter. It is said that a full-wave rectifying X-ray equipment such as the fabricated system can shorten initiating period and be precision control because of stable output, compared with the X-ray equipment of a half wave rectifying type used in the usual clinical medicine. In order to evaluate the capability of the fabricated high tension generator, I performed exposure dose characteristics experiments.

  • PDF

Present State of Self-Rectifying Air Turbines for Wave Energy Conversion

  • Setoguchi, Toshiaki;Takao, Manabu
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.3-12
    • /
    • 2003
  • This paper reviews the present state of the art on the self-rectifying air turbines, which could be used for wave energy conversion. The overall performances of the turbines under irregular wave conditions, which typically occur in the sea, have been evaluated numerically and compared from the viewpoints of the starting and running characteristics. The types of turbine included in the paper are as follows: (a) Wells turbine with guide vanes (WTGV); (b) turbine with self-pitch-controlled blades (TSCB); (c) biplane Wells turbine with guide vanes (BWGV); (d) impulse turbine with self-pitch-controlled guide vanes (ISGV) and (e) impulse turbine with fixed guide vanes (IFGV). As a result, under irregular wave conditions it is found that the running and starting characteristics of the impulse type turbines could be superior to those of the Wells turbine. Moreover, the authors have explained the mechanism of hysteretic behavior of the Wells turbine and the necessity of links for improvement of the performance of ISGV.

  • PDF

A dominant negative OsKAT2 mutant delays light-induced stomatal opening and improves drought tolerance without yield penalty in rice

  • Kim, Jin-Ae;Moon, Seok-Jun;Lee, Yongsang;Min, Myung Ki;Yoon, In sun;Kwon, Taek-Ryoun;Kim, Beom-Gi
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.110-110
    • /
    • 2017
  • Stomata are the main gateways for water and air transport between leaves and the environment. Inward-rectifying potassium channels regulate photo-induced stomatal opening. Rice contains three inward rectifying shaker-like potassium channel proteins, OsKAT1, OsKAT2 and OsKAT3. Among these, only OsKAT2 is specifically expressed in guard cells. Here, we investigated the functions of OsKAT2 in stomatal regulation using three dominant negative mutant proteins, OsKAT2(T235R), OsKAT2(T285A) and OsKAT2(T285D), which are altered in amino acids in the channel pore and at a phosphorylation site. Yeast complementation and patch clamp assays showed that all three mutant proteins lost channel activity. However, among plants overexpressing these mutant proteins, only plants overexpressing OsKAT2(T235R) showed significantly less water loss than the control. Moreover, overexpression of this mutant protein led to delayed photo-induced stomatal opening and increased drought tolerance. Our results indicate that OsKAT2 is an inward-rectifying shaker-like potassium channel that mainly functions in stomatal opening. Interestingly, overexpression of OsKAT2(T235R) did not cause serious defects in growth or yield in rice, suggesting that OsKAT2 is a potential target for engineering plants with improved drought tolerance without yield penalty.

  • PDF

Modulation of Inwardly Rectifying $K^+$ Channel by Intracellular and Extracellular pH in Bovine Aortic Endothelial Cells

  • Park, Kyu-Sang;Kong, In-Deok;Lee, Joong-Woo;Rhim, Hye-Whon;Kim, Young-Chul;So, In-Suk;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권5호
    • /
    • pp.255-260
    • /
    • 2002
  • The effects of intracellular and extracellular pH on the inwardly rectifying $K^+$ (IRK) channel of the bovine aortic endothelial cells (BAECs) were examined using whole-cell patch-clamp technique. The IRK current, efficiently blocked by $Ba^{2+}\;(200{\mu}M),$ is the most prominent membrane current in BAECs, which mainly determines the resting membrane potential. The expression of Kir2.1 was observed in BAECs using reverse transcriptase-polymerase chain reaction (RT-PCR) analysis. Intracellular alkalinization, elicited by the extracellular substitution of NaCl with $NH_4Cl$ (30 mM), significantly augmented the amplitude of IRK current. On the contrary, the amplitude of IRK current was attenuated by the Na-acetate (30 mM)-induced intracellular acidification. The changes in extracellular pH also closely modulated the amplitude of IRK current, which was decreased to $40.2{\pm}1.3%$ of control upon switching the extracellular pH to 4.0 from 7.4. The extracellular pH value for half-maximal inhibition (pK) of IRK current was 5.11. These results demonstrate that the activity of IRK channel in BAECs, probably Kir2.1, was suppressed by proton at both sides of plasma membrane.

태양광발전을 이용한 에어콘의 보조운전 제어 시스템 (Auxiliary Power Supply using Photovoltaic Power Generation for Air-Conditioner)

  • 황인호;유권종;송진수;이후기;정찬규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국태양에너지학회, 한국에너지공학회 1993년도 춘계 공동학술발표회 초록집
    • /
    • pp.47-52
    • /
    • 1993
  • Recently, as exactly clean source, the research of photovoltaic power generation is undertaken actively and widely. In this paper, an auxiliary power supply system which is composed of photovoltaic generation and DC-DC boost chopper is described. This system in mainly for Air-conditioner appliances is which AC source is formed through rectifying circuit and without electrical storage battery. There exist two operating modes depending on the power quantity of the solar cells and the load. The control algorithm is discussed.

  • PDF

미래손실에 기초한 통합공정관리계획 (An Integrated Process Control Scheme Based on the Future Loss)

  • 박창순;이재헌
    • 응용통계연구
    • /
    • 제21권2호
    • /
    • pp.247-264
    • /
    • 2008
  • 통합공정관리의 기본절차는 잡음이 내재하는 공정에 대하여 수정조치를 취하고, 수정활동 중 공정에 이상원인이 발생하면 관리도를 통하여 발생을 탐지하고 교정활동을 통하여 이를 제거하게 된다. 그러나 공정의 교정활동은 많은 시간과 비용을 수반하는 비생산적 요인을 유발할 수 있기 때문에 무조건적 교정활동은 생산성을 저하시키는 반대 급부도 동시에 내포하고 있다. 이 논문에서는 공정모형으로 ARIMA(0,1,1) 모형을 가정하고 공정 평균과 분산에 이상원인이 발생하는 경우 이를 탐지하는 절차를 소개하고, 이상신호의 시점에서 공정 잔여시간 동안 발생할 수 있는 미래손실에 기초하여 교정 활동의 여부를 판단하는 통합공정관리 절차를 제안한다.

인덕터를 사용하지 않는 새로운 AC-DC 변환 방식 (A novel AC-DC switching technology without inductors)

  • 윤진한;차형우;이만섭;조영창
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.138-140
    • /
    • 2007
  • A novel AC-DC switching technology is suggested without inductors for one-chip semiconductor. The suggested converter consists of a rectifier diodes, AC source level detector, switching control, detector of over-current and voltage, feedback controller and switching block, The key technology of the proposed AC-DC converting methode is detecting of the low level voltage for AC voltage, power control transistor and rectifying of DC level. The measurement results with commercial devices show that the converter has power efficiency of 66.5% for DC 12V 0.24A and the standby power is 49.58mW at AC 110V.

  • PDF