• 제목/요약/키워드: Rectangular column

검색결과 197건 처리시간 0.019초

CFT기둥과 합성보로 구성된 CJS합성구조시스템의 유한요소해석 연구 (Finite Element Analysis Study of CJS Composite Structural System with CFT Columns and Composite Beams)

  • 문아해;신지욱;임창규;이기학
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.71-82
    • /
    • 2022
  • This paper presents the effect on the inelastic behavior and structural performance of concrete and filled steel pipe through a numerical method for reliable judgment under various load conditions of the CJS composite structural system. Variable values optimized for the CJS synthetic structural system and the effects of multiple variables used for finite element analysis to present analytical modeling were compared and analyzed with experimental results. The Winfrith concrete model was used as a concrete material model that describes the confinement effect well, and the concrete structure was modeled with solid elements. Through geometric analysis of shell and solid elements, rectangular steel pipe columns and steel elements were modeled as shell elements. In addition, the slip behavior of the joint between the concrete column and the rectangular steel pipe was described using the Surface-to-Surface function. After finite element analysis modeling, simulation was performed for cyclic loading after assuming that the lower part of the foundation was a pin in the same way as in the experiment. The analysis model was verified by comparing the calculated analysis results with the experimental results, focusing on initial stiffness, maximum strength, and energy dissipation capability.

4각형 고강도 콘크리트 기둥 단면 변형을 통한 CFS Jacketing 보강방법 개발 (Development of CFS Jacketing Retrofit Method for Rectangular High Strength Concrete Columns by Cross Sectional Shape Modification)

  • 이종길;김장호;박석균;김진근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.153-161
    • /
    • 2010
  • 1970년대에 콘크리트를 기반으로 지어진 많은 구조물과 빌딩은 안전성과 사용성을 고려하여 무수히 많은 연구를 현재까지 진행해 왔으나, 설계강도 보다 낮은 최대강도를 보이고 있다. 현재 노후화된 콘크리트 구조물들에 대한 다양한 보수 보강 공법이 개발되어 적용되고 있지만 기존 연구들은 구조물의 특성에 대해서는 고려하지 않고, 단지 기존 부재와 보수 재료의 부착에 관한 연구와 기존 부재를 효과적으로 보강하기 위한 새로운 방법을 개발하는 연구는 미흡한 실정이다. 따라서 본 연구는 보수 보강 재료를 이용한 효율적인 강도증진 방법에 대한 연구, 보강 재료와 기존 부재 사이의 거동에 대해 부족했던 연구를 보완하고자 한다. 또한 고강도 콘크리트는 높은 압축강도를 발현하기 때문에 부재의 단면을 축소시킬 뿐만 아니라 구조물의 자중 또한 감소시킬 수 있으므로 거대한 구조물 건설에 사용되고 있다. 고강도 콘크리트의 사용이 점차 증가하는 추세이지만 고강도 콘크리트를 이용한 구조물의 보수 보강에 대한 방법 연구 역시 미진한 실정이다. 따라서 본 연구에서는 효과적인 고강도 콘크리트 기둥에 대한 보수 보강 방법을 개발하고자 한다. 본 연구에서는 사각단명 형상을 가진 기둥을 팔각단면으로 형상 변형을 통해 CFS로 보수 보강하여 단면 형상이 변함에 따른 효과를 파악하고, CFS로 보강된 고강도 콘크리트(HSC) 기둥의 강도 증대 효과와 파괴 거동에 대해 파악하고자 한다.

녹두의 Peroxidase Isozyme C의 생화학적 성장 (Purification and Characterization of Peroxidase Isozyme C from Mung Bean)

  • 이상갑;박우철
    • Applied Biological Chemistry
    • /
    • 제30권3호
    • /
    • pp.219-226
    • /
    • 1987
  • 녹두의 자엽에서 peroxidase isozyme을 $(NH_4)_2SO_4$ 침전, Sephadex G-75, DEAE-cellulose 및 DEAE-Sephadex A-50 column chromatography 등으로 63배 정제하여 그 특성 및 결정구조를 조사하였다. Isozyme C는 Rm 값이 0.24로서 분자량이 50,000 dalton인 단량체였다. 이 효소의 반응 최적 PH는 o-dianisidine에 대하여 5.0, guaiacol에 대해서는 6.0, 반응 최적온도는 $70^{\circ}C$였으며 열에 대해서도 비교적 안정하였다. o-dianisidine과 guaiacol에 대한 Km 값은 각각 0.11mM, 60.98mM이었으며, isozyme C에 대한 기질과 cyanide는 경쟁적 저해형식을 나타내었다. Isozyme C는 평면상 직사각형의 결정구조를 하고 있었다.

  • PDF

변위연성도를 고려한 RC 사각단면 기둥의 전단강도 (The shear strength of RC rectangular sectional columns considering displacement ductility)

  • 선창호;김익현
    • 한국지진공학회논문집
    • /
    • 제14권2호
    • /
    • pp.37-47
    • /
    • 2010
  • RC교량이 내진성능을 확보하기 위해서는 교각의 연성도가 목표연성도에 도달하기 전에 발생하는 전단파괴가 방지되어야 한다. 이를 위해서는 신뢰성 있는 전단강도 평가식이 요구된다. 횡하중을 받는 RC기둥의 전단강도는 변위연성도의 증가에 따라 감소 하는 특성을 나타낸다. 다수의 연구자에 의해 전단강도 식이 제안되어 있으나 변위연성도가 작은 구역에서의 초기전단강도와 연성도 증가에 따른 전단강도의 감소율에서 많은 차이를 보이고 있다. 본 연구에서는 저자들이 제안한 초기전단강도를 기본으로 하여 다른 연구자에 의해서 수행된 많은 기둥실험 결과를 분석하여 변위연성도를 고려한 새로운 전단강도 평가식을 제안하였다, 제안된 평가식은 다른 평가식과의 비교를 통해 정확도가 크게 개선된 것을 확인하였다.

결함 상세를 포함하는 철근콘크리트 전단벽의 수치 모델에 관한 실험적 평가 (Experimental Assessment of Numerical Models for Reinforced Concrete Shear Walls with Deficient Details)

  • 전성하;박지훈
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.211-222
    • /
    • 2016
  • Reinforced concrete shear walls with deficient reinforcement details are tested under cyclic loading. The deficiency of reinforcement details includes insufficient splice length in U-stirrups at the ends of horizontal reinforcement and boundary column dowel bars found in existing low- to mid-rise Korean buildings designed non-seismically. Three test specimens have rectangular, babel and flanged sections, respectively. Flexure- and shear-controlled models for reinforced concrete shear walls specified in ASCE/SEI 41-13 are compared with the flexural and shear components of force-displacement relation extracted separately from the top displacement of the specimen based on the displacement data measured at diverse locations. Modification of the shear wall models in ASCE/SEI 41-13 is proposed in order to account for the effect of bar slip, cracking loads in flexure and shear. The proposed modification shows better approximation of the test results compared to the original models.

An Experimental Study of Reinforced Concrete Beams with Closely-Spaced Headed Bars

  • Lam, Kah Mun;Kim, Woo-Suk;Van Zandt, Michael;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제5권2호
    • /
    • pp.77-85
    • /
    • 2011
  • The use of headed bars as opposed to standard 90- or 180-degree hooked bars in beam ends, beam-column joints or other steel congested areas for anchorage and bond has become more favorable due to the fact that steel congestion is often created by large bend diameters or crossties. This research mainly focuses on evaluating the code provisions regarding the use of headed bars. Nine simply supported rectangular concrete beams with headed longitudinal reinforcement were tested under a four-point monotonic loading system. The design clear spacing, which varies from 1.5 to 4.25 times the bar diameter, was the only parameter for the experimental investigation. The test results showed that the closely-spaced headed bars were capable of developing to full yield strength without any severe brittle concrete breakout cone or pullout failure. Bond along the bar was not sufficient due to the early loss of concrete integrity. However, the headed bars were effective for anchorage with no excessive moment capacity reduction. This implies that the clear spacing of about 2 times the bar diameter for headed bars may be reasonable to ensure the development of specified yield strength of headed bars and corresponding member design strength.

고대 백제.신라.일본의 초석 형태에 따른 공간위계 비교연구 (A comparative study on the spatial hierarchy by the form of the basestone in ancient architecture between Baekje, Silla and Japan)

  • 한욱
    • 한국실내디자인학회논문집
    • /
    • 제17권6호
    • /
    • pp.3-10
    • /
    • 2008
  • The basestone is a kind of foundation part of the building and can be said to deliver the loads from the upper part to ground. It is the explanation of structural role for the basestone. But the basestone has been used as the decorative element in a building. So this study is on design of the basestone. First the type division can be studied as form of the basestones. Also the investigation of development aspect of them needs to as times and the spatial characteristics. Another goal of this study is on the design characteristics of the basestone from the comparison to the basestone in ancient Japan was initiated in the architectural technology from Korea. The results are as follows. In Baekje rectangular basestones were used in static space for ceremony and circular ones were used in dynamic space for life. Also the basestones with joojwa(smoothing surface for sitting on column) were used for accessory buildings rather than main. In Silla the same type of basestone was made in a temple but according to hierarchy of buildings the sizes of them seem to have been different. The other side in Japan carved basestones were for the main buildings and for the accessory natural stones were used to. According to the hierarchy of the buildings the kinds of stones were different.

The M6.4 Lefkada 2003, Greece, earthquake: dynamic response of a 3-storey R/C structure on soft soil

  • Giarlelis, Christos;Lekka, Despina;Mylonakis, George;Karabalis, Dimitris L.
    • Earthquakes and Structures
    • /
    • 제2권3호
    • /
    • pp.257-277
    • /
    • 2011
  • An evaluation is presented of the response of a 3-storey R/C structure during the destructive Lefkada earthquake of 14/08/2003. Key aspects of the event include: (1) the unusually strong levels of ground motion (PGA = 0.48 g, $SA_{max}$ = 2.2 g) recorded approximately 10 km from fault, in downtown Lefkada; (2) the surprisingly low structural damage in the area; (3) the very soft soil conditions ($V_{s,max}$ = 150 m/s). Structural, geotechnical and seismological aspects of the earthquake are discussed. The study focuses on a 3-storey building, an elongated structure of rectangular plan supported on strip footings, that suffered severe column damage in the longitudinal direction, yet minor damage in the transverse one. Detailed spectral and time-history analyses highlight the interplay of soil, foundation and superstructure in modifying seismic demand in the two orthogonal directions of the building. It is shown that soil-structure interaction may affect inelastic seismic response and alter the dynamic behavior even for relatively flexible systems such as the structure at hand.

Damping identification procedure for linear systems: mixed numerical-experimental approach

  • El-Anwar, Hazem Hossam;Serror, Mohammed Hassanien;Sayed, Hesham Sobhy
    • Earthquakes and Structures
    • /
    • 제4권2호
    • /
    • pp.203-217
    • /
    • 2013
  • In recent decades, it has been realized that increasing the lateral stiffness of structure subjected to lateral loads is not the only parameter enhancing safety or reducing damage. Factors such as ductility and damping govern the structural response due to lateral loads. Despite the significant contribution of damping in resisting lateral loads, especially at resonance, there is no accurate mathematical representation for it. The main objective of this study is to develop a damping identification procedure for linear systems based on a mixed numerical-experimental approach, assuming viscous damping. The proposed procedure has been applied to a laboratory experiment associated with a numerical model, where a hollow rectangular steel cantilever column, having three lumped masses, has been fixed on a shaking table subjected to different exciting waves. The modal damping ratio has been identified; in addition, the effect of adding filling material to the hollow specimen has been studied in relation to damping enhancement. The results have revealed that the numerically computed response based on the identified damping is in a good fitting with the measured response. Moreover, the filling material has a significant effect in increasing the modal damping.

Control of 3-D coupled responses of wind-excited tall buildings by a spatially placed TLCD system

  • Liang, Shuguo;Li, Qiusheng;Qu, Weilian
    • Wind and Structures
    • /
    • 제3권3호
    • /
    • pp.193-207
    • /
    • 2000
  • The possible application of a spatially placed passive tuned liquid column damper system for suppressing coupled lateral-torsional responses of tall buildings is investigated in this paper. The wind loads acting on rectangular tall buildings are analytically expressed as 3-D stochastic model. Meanwhile, the 3-D responses of tall buildings may be coupled due to eccentricities between the stiffness and mass centers of the buildings. In these cases, torsional responses of the buildings are rather larger, and a TLCD system composed of several TLCD located near the sides of the buildings is more effective than the same TLCD placed at the building center in reducing both translational and torsional responses of the buildings. In this paper, extensive analytical and numerical work has been done to present the calculation method and optimize the parameters of such TLCD systems. The numerical examples show that the spatially placed TLCD system can reduce coupled along-wind, across-wind and torsional responses significantly with a fairly small mass ratio.