• Title/Summary/Keyword: Rectangular cell

Search Result 159, Processing Time 0.026 seconds

Numerical Analysis on Flow Fields and the Calculation of Wave Making Resistance about Air Supported Ships (수치시뮬레이션에 의한 공기부양선 주위의 유동장해석과 조파저항계산)

  • Na Y. I.;Lee Y.-G.
    • Journal of computational fluids engineering
    • /
    • v.1 no.1
    • /
    • pp.55-63
    • /
    • 1996
  • Numerical computations are carried out to analyze the characteristics of flow fields around Air Supported Ships. The computations are performed in a rectangular grid system based on MAC(Marker And Cell) method. The governing equations are represented in finite difference forms by forward differencing in time and centered differencing in space except for its convection terms. For the certification of this numerical analysis method, the computations of flow fields around a Catamaran, an ACV(Air Cushion Vehicle) modeled with pressure distribution on free surface and two SES(Surface Effect Ship)'s are carried out, The results of the present computations are compared with the previously presented computational and experimental results in the same condition.

  • PDF

Performance Analysis of PEMFC Using Computational Flow Dynamics (CFD) (전산유체역학 (CFD)을 이용한 PEMFC의 성능분석)

  • Kim, Sunhoe
    • Journal of Digital Convergence
    • /
    • v.11 no.8
    • /
    • pp.199-204
    • /
    • 2013
  • Computational fluid dynamics (CFD) is used to reduce number of experiments. The CFD tools are widely used for engine design and flow pattern analysis to reduce experiments. In this study the performance of a PEMFC single cell was analyzed by using STAR-CD, product of CD-ADAPCO. The effect of cell design and flow pattern on the performance of a PEMFC was analyzed with the 3-D simulation. As a result the performance of rectangular cell was the higher than that of square cell, while the flow direction scarcely affected on the performance of a PEMFC. Also the current density according to different excess ratio of air flow rate was compared and analyzed. The difference between maximum and minimum current density of flip-flow was lower than that of co-flow.

The Analysis of a Coaxial-to-Waveguide Transition Using FDTD with Cylindrical to Rectangular Cell Interpolation Scheme

  • Yu, Kyung-Wan;Kang, Sung-Choon;Kang, Hee-Jin;Choi, Jae-Hoon;Kim, Jin-Dae
    • ETRI Journal
    • /
    • v.21 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • We analyze the characteristics of a coaxial-to-waveguide transition based on the finite difference time domain (FDTD) method with the cylindrical to rectangular cell interpolation scheme. The scheme presented in this paper is well suited for the analysis of a microwave device with a probe near waveguide discontinuity because perfect TEM mode can be generated inside the coaxial cable by using the cylindrical cell. The scattering parameters of a designed Ka-band transition are evaluated and compared with those of commercially available software, High Frequency Structure analysis Simulator (HFSS) and measured data. There exists good agreement between the measured and calculated data. In order to prove an accuracy of the interpolation scheme, a coaxial to waveguide transition with a disk-loaded probe is analyzed by the present approach and the results of this analysis are compared with measured data. Comparison shows that our results match very closely to those of measurement and other approaches. The method presented in this paper can be applied to analyze the characteristics of a probe excited cavity, coaxial waveguide T-Junctions, and so on.

  • PDF

The Comparison of Field Uniformity and SAR between TEM, Loop and Combined Elemented 16 Channel Transmit Arrays (TEM 형과 Loop 형의 전송소자를 이용한 16채널 3T Body 전송코일의 자장 균일도와 안전도 비교)

  • Ryu, Yeunchul;Kim, Young Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.404-408
    • /
    • 2014
  • In this research we evaluate the excitation homogeneity and SAR of three different Tx arrays after B1+ Shimming in the human body at 3T. Through the simulations, we compared the field properties that are standard deviation and mean value of transverse magnetization for 1) strip line TEM array, 2) rectangular loop array, 3) combined array of strip line element and rectangular loop and shown the utilities of B1+ shimming in human body model. After B1+ shimming, it is evaluated four different types of SAR for body mesh through whole body simulation; those are average, maximum 1-cell, maximum 1-gram, and maximum 10-gram SAR. It appears that in this particular comparison an array based on strip line elements can produce better homogeneity and lower SAR than an array of rectangular loops or an array of combined elements (strip line and loop). While many factors are considered in designing coils for production, it is hoped that methods and results like these will be used in the future to guide decisions and maximize benefit.

Finite Element Analysis of Cellular Material According to Aspect Ratio of Cell (셀의 형상비에 따른 미세기공 재료의 유한요소해석)

  • 윤성원;이정우;강충길
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.890-893
    • /
    • 2002
  • This study is focused to predict the behavior of Al foam with closed-cell structure during the 3 point bending test and the upsetting test according to aspect ratio. We calculated characters of aluminum foams with closed-cell structure and took the simulation. The effects on the aspect ratio of the cell was investigated parametrically. The analysis was carried out on two models, First, the bending test in elasticity of the rectangular beam, and Second, the upsetting test in plasticity of the circular cylinder. In the analysis, the deformation of the beam and the cylinder was influenced by the aspect ratio of the cell. Further, We assumed that the geometry of feared aluminum cell change the stress and strain in the test.

  • PDF

Full Size PDP Development with SDR Structure for Improved Luminance and Low Power Consumption

  • Yoo, Min-Sun;Yoon, Cha-Keun;Lee, Kwang-Sik;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.53-56
    • /
    • 2002
  • Samsung's newly developed high luminance efficiency 42" VGA plasma display panel is introduced. A new discharge cell structure, SDR (Segmented electrode in Delta color arrayed Rectangular subpixel) has been applied to a full size panel for the first time. In this paper, we describe how this new discharge cell structure for high efficiency is integrated to an energy saving plasma display with better picture quality.

  • PDF

A Spectral Inverse Scattering Technique with Series-Expanded Field in Dirlectric Object (유전체 내의 전계를 급수전개로 표시한 모멘트 방법을 적용한 파수영역의 역산란 방법)

  • 최현철
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.147-151
    • /
    • 1989
  • A spectral inversion scheme, based on the moment-method procudure with series-expanded field within each cell by dividing the dielectric object into a small number os rectangular cells with large area, is developed to regularize the ill-posedness inherent in inverse scattering problems. One of the interesting features on the presented scheme is that the relative dielectric constant may be obtained by averaging over each cell. This averaging is expected to play an important role in regularizing the high-frequency effect due to noise.

  • PDF

Numerical Analysis of Electromagnetic Fields in TEM Cells (TEM CELL에서의 전자장 수치해석)

  • 이애경;이상회;김정기
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.1
    • /
    • pp.37-45
    • /
    • 1991
  • The electromagnetic field distribution within rectangular coaxial transmission lines (RCTL:TEM cells) is calculated using a numerical method. Boundary integral equations(BIE) considering equivalence theorem and extended boundary condition(EBC) in tapered region are used, thereby restricting the operational frequencies (0~130 MHz) below the cell cutoff frequency(130 MHz). The EM fields within NIST TEM cell ($1\times0.6\times2m$) are calculated by this method. The results of the numerical calcuation have a good agreement in the cross-sectional EM field distribution of TEM cell with 2-dimensional analysis results. Based on this method, the first cutoff freque- ncy in high order modes in the cell and the electric field polarization are considered.

  • PDF

Experimental Study on Flow Characteristics in Meandering Channel (사행수로에서 흐름 특성에 관한 실험적 연구)

  • Seo, Il-Won;Sung, Ki-Hoon;Baek, Kyong-Oh;Jeong, Seong-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.7
    • /
    • pp.527-540
    • /
    • 2004
  • In order to investigate characteristics of the primary flow and the secondary currents in the meandering channel, laboratory experiments were conducted in the meandering channel made up of alterative bends haying 120。 arc angle. Experiments were performed in two types of cross-sections, a rectangular cross-section and a curved cross-section which was made to adopt a beta probability function. Three-dimensional velocity fields were measured using a micro-ADV. As the result of experiments, in case of the rectangular cross-section, the primary flow occurred taking the shortest course, which is similar to the result of previous researches. In case of the curved cross-section, the primary flow was expected to occur along the thalweg. but it occurred almost along the shortest way. This is considered due to effects of bottom roughness and sinuosity Not only a main cell but also a secondary cell of secondary currents were clearly shown by mean of the stream function. The secondary current intensity has the maximum value near the apex of the second bend for cases of both rectangular and curved cross-sections. However, the value of the secondary current intensity for the curved section is slightly larger than that for the rectangular cross-section. Also, in case of the rectangular cross-section, the higher the ratio of width to depth is, the larger the secondary current intensity is.

Enhanced UV-Visible Absorbance Detection in Capillary Electrophoresis Using Modified T-Shaped Post-Column Flow Cell

  • Lim, Kwan-Seop;Kim, Su-Hyeon;Hahn, Jong-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.295-300
    • /
    • 2002
  • The construction of the T-shaped post-column flow cell has been changed to enhance the practicability as a UV-visible absorbance detector for capillary electrophoresis. In this new design, a rectangular cube-shaped inner structure is employed, which completely fits the outer rectangular tubing. This arrangement has greatly facilitated the fabrication of the T-cells. In addition, the volume for the auxiliary flow has been dramatically reduced down to 300 ${\mu}L$, and its volume flow rate is optimized at 4.2 ${\mu}L$/min. The short optical path length in the sheath flows (500 ${\mu}m$ on each side) minimizes background absorption, and thus enhances its performance in low-UV wavelengths. We have optimized the auxiliary flow rate at 50 ${\mu}m$/s, so that migration times are insensitive to the flow rate. This optimization has improved repeatabilities in migration times and peak heights. A double-beam detection scheme using a pair of photodiodes is employed to increase the signal-to-noise ratio.