• Title/Summary/Keyword: Rectangular Parallelepiped

Search Result 38, Processing Time 0.028 seconds

A Study of Bonding Strength of Repaired Resin Denture Base by Artificial Saliva Absorption (레진의치상 수리 시 인공타액 흡수도에 따른 결합강도 연구)

  • Kang, Myung-Ho;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.25-35
    • /
    • 2011
  • Purpose: There are some advantages of the acrylic resin denture base ; appropriate strength, volume safety, simple processing apparatus, and low cost. But, it have a weakness for fracture by intense pressure or shock. However, the repairs for resin denture base are possible using various materials and techniques. There is a few studies in repairs for resin denture base, but not clinical researches. And there is no studies in absorbed saliva into the region of fracture and bond strength. This study is to observe re-bond strength of resin denture base after repairing under saliva absorption. Methods: The samples were made of heat curing resin and the rectangular parallelepiped specimens which were 50mm long, 10mm wide and 3mm high. The four different groups immersed in the artificial saliva for 2 weeks were prepared, 1) no repaired control samples, 2) immediately repaired samples, 3) repaired samples after 1 day dry, and 4) repaired samples after 3 days dry. The prepared samples were repaired by two different curing materials, self curing resin and heat curing resin method. Each groups composed of 10 specimens were experimented with the three point bending tests for bonding strength measuring Results: There were under condition absorbed in the artificial saliva and repaired by self curing resin method, repaired specimens after 1 day and 3 days dry groups had higher values of bonding strengths than control group, and bonding strengths of immediately repaired samples were similar to those of control samples (p<0.05). There were under condition immersed in the artificial saliva and repaired by heat curing resin method, immediately repaired samples showed similar values to bonding strengths of control groups, and repaired samples after 1 day and 3 days dry groups were lower than those of control group (p>0.05). Conclusion: In this study, the repairs for resin denture base were remarkably high values of bonding strengths than those of the past, and showed that have stable bonding strengths independent of saliva absorption of denture base, so present repairs for resin denture base can be performed, regardless of saliva conditions.

Difference of holding power of concrete weight used in shellfish shell fishery by its shape characteristics (패류껍질어업에서 사용 중인 멍의 형태적 특성에 따른 고정력의 차이)

  • LEE, Gun-Ho;CHO, Sam-Kwang;KIM, In-Ok;CHA, Bong-Jin;JUNG, Seong-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • In this study, the differences of holding power according to the shape and weight distribution of concrete weight used in shellfish shell fishery were investigated through the experiments. To investigate the differences in shape, five bar-shaped concrete weights with the same length and different cross-sectional shapes were produced. The sectional shape of each weight was square, triangle, circle, small cross, and large cross (SQ, TR, CI, CR-S, CR-L). Ten rectangular parallelepiped weights with different bottom area and cross-sectional area were produced. To investigate the differences by the weight distribution, the holding power on the square model (SQ) with six 50 g weights at different positions was investigated. All the holding power was obtained by measuring the tensile force generated when the concrete weight was pulled at a constant speed on the sand. As a result, there were no differences in holding power between the ten rectangular weights. However, the experiment on weights with different cross-sectional shapes showed differences in holding power. The holding power was higher in the order of CR-L > CR-S > CI > TR > SQ. In the weight distribution test, the holding power was higher as the front side of the weight was heavier. Generally, the frictional force is the same even if the shape is different, when two objects have the same value in the weight and the roughness. On the other hand, it seems to have a large impact when the shape of the bottom is deformed in the course of pulling the object. Particularly, the larger the degree of protrusion like cruciform weights, the more the holding power increased while deeply digging the bottom. It is also likely that the holding power increases as the front weight increases.

A CT Simulator Phantom for Geometrica1 Test (CT 시뮬레이터의 기하학적 성능평가용 팬톰)

  • Min, Chul-Kee;Yi, Byong-Yong;Ahn, Seung-Do;Choi, Eun-Kyung;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.337-344
    • /
    • 2000
  • Purpose :To design and test test CT simulator phantom for geometrical test. Materials and Methods : The PMMA phantom was designed as a cylinder which is 20 cm in diameter and 24 cm in length, along with a 25$\times25\times31cm^{3}$ rectangular parallelepiped. Radio-opaque wires of which diameter is 0.8 mm are attached on the other surface of the phantom as a spiral. The rectangular phantom was made of four 24$\times24\times0.5 cm^{3}$ square plates and each plate had a 24$\times24 cm^{2}$, 12$\times12cm^{2}$, 6$\times6 cm$^{2}$ square line. The squares were placed to face the cylinder at angles 0 $^{\circ}$ , 15 $^{\circ}$ , 30 $^{\circ}$ ,respectively. The rectangular phantom made it possible to measure the field size, couch angle, the collimator angle, the isocenter shift and the SSD, the measurements of the gantry angle from the cylindrical part. A virtual simulation software, AcOSim, offered various conditions to perform virtual simulations and these results were used to perform the geometrical Quality assurance of CT simulator. Results : A 0.3$\~$0.5 mm difference was found on the 24 cm field size which was created with the DRR measurements obtained by scanning of the rectangular phantom. The isocenter shift, the collimator rotation, the couch rotation, and the gantry rotation test showed 0.5$\~$1 mm, 0.5$\~$l$^{\circ}$ 0.5$\~$ 1$^{\circ}$ , and 0.5-1 $^{\circ}$ differences, respectively. We could not find any significant differences between the results from the two scanning methods. Conclusion :The geometrical test phantom developed in the study showed less than 1 mm (or 1 $^{\circ}$ ) differences. The phantom could be used as a routine geometrical QC/QA tools, since the differences are within clinically acceptable ranges.

  • PDF

Effect of bone graft materials on bone formation in guided bone regeneration using perforated titanium membrane (천공형 티타늄막을 이용한 골유도재생술 시 수종의 골이식재가 골재생에 미치는 영향)

  • Hong, Seung-Bum;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.223-237
    • /
    • 2006
  • The purpose of the present study was to evaluate the effect of bone graft materials including deproteinized bovine bone(DBB), demineralized freeze-dried bone(DFDB), freeze-dried bone(FDB) on bone formation in guided bone regeneration using perforated titanium membrane(TM). 16 adult male rabbits(mean BW 2kg) were used in this study and 4 rabbits allotted to each test group. Intramarrow penetration(diameter 6.5mm) was done with round carbide bur on calvaria to promote blood supply and clot formation in the wound area. The test groups were devided into 4 groups as follows: TM only(test 1), TM +DBB(test 2), TM +DFDB(test 3), TM +FDB(test 4). Perforated titanium membrane was contoured in rectangular parallelepiped shape(0.5mm pore diameter, 10mm in one side, 2mm in inner height), filled the each graft material and placed on the decorticated carvaria. Perforated titanium membrane was fixed with resorbable suture materials. The animals were sacrificed at 2, 8 weeks after the surgery. Non-decalcified preparations were routinely processed for histologic analysis. The results of this study were as follows: 1. Perforated titanium membrane was biocompatible. 2. Perforated titanium membrane had capability of maintaining the space during the healing period but invasion of soft tissue through the perforations of titanium membrane decreased the space available for bone formation. 3. In test 1 group without bone graft material, the amount of bone formation and bone maturation was better than other test groups. 4. Among the graft materials, the effect of freeze-dried bone on bone formation was best. 5. In the test groups using deproteinized bovine bone, demineralized freeze-dried bone, bone formation was a little. The spacemaking capability of the membrane may be crucial for bone formation. The combined treatment with the perforated titanium membrane and deproteinized bovine bone or demineralized freeze-dried bone failed to demonstrate any added effect in the bone formation. Minimization of size and numbers of perforations of titanium membrane or use of occlusive titanium membrane might be effective to acquire predictable results in the vertical bone formation.

Nonlinear Thermo-mechanical Analysis Considering Heat Flow under Fire Conditions (화재 열 유동을 고려한 구조물의 열응력해석)

  • Pak, Hongrak;Kang, Jun Won;Lee, Jinwoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.4
    • /
    • pp.369-376
    • /
    • 2016
  • In this study, a numerical analysis framework for investigating the nonlinear behavior of structures under fire conditions is presented. In particular, analysis procedure combining fire-driven flow simulation and thermo-mechanical analysis is discussed to investigate the mechanical behavior of fire-exposed representative volume structures made of steel and concrete, respectively. First of all, fire-driven flow analysis is conducted using Fire Dynamics Simulator(FDS) in a rectangular parallelepiped domain containing the structure. The FDS simulation yields the time history of temperature on the surface of the structure under fire conditions. Second, mechanical responses of the fire-exposed structure with respect to prescribed uniformly distributed loads are calculated by a coupled thermo-mechanical analysis using the time-varying surface temperature as boundary conditions. Material nonlinearities of steel and concrete have been considered in the thermo-mechanical analysis. A series of numerical results are presented to demonstrate the feasibility of the multiphysics structural fire analysis for investigating the structural behavior under fire conditions.

The effect of irradiated cancellous human bone on exophytic bone formation in residual ridge of the beagle dog (방사선 조사 망상골이 외방형 골형성에 미치는 영향)

  • Chung, Mi-Hyun;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.791-803
    • /
    • 2007
  • The purpose of this study was to evaluate exophytically vertical bone formation in residual ridge of the beagle dog by the concept of guided bone regeneration with a titanium reinforced e-PTFE membrane combined with irradiated cancellous human bone. Twelve male beagle dogs(mean age 1.5 years and mean weight 12kg) were used for this study. The alveolar ridges after extraction of all mandibular premolars were surgically and horizontally removed. At 8 weeks after extractions, full-thickness flap was reflected and cortical bone was removed with round bur and copious irrigation. Rectangular parallelepiped(10mm in length, 5mm in width, and 4mm in height) bended with titanium-reinforced e-PTFE(TR e-PTFE) membrane was placed on the decorticated alveolar ridge, fixed with metal pins and covered with full-thickness flap and assigned as a control group. Test groups ere treated with TR e-PTFE membrane filled with irradiated cancellous human bone. Of twelve beagle dogs, four control dogs and four test dogs without membrane exposure to oral cavity were sacrificed at 8 and 16 weeks respectively. The surgical sites were dissected out, fixed in 4% buffered formaldehyde, dyed using a Villanueva staining technique, and processed for embedding in plastic resin. The cutting and grinding methods were routinely processed for histologic and histomophometric analyis of exophytic bone formation as well as statistical analysis. The results of this study were as follows: 1. Exophytic bone formation in the both of experimental groups was increased respectively after surgery from 23.40% at 8 weeks to 46.26% at 16 weeks in the control groups, from 40.23% at 8 weeks to 47.11% at 16 weeks in the test groups(p<0.05). 2. At 8 weeks after surgery, exophytic bone formation was made 40.23% in the test groups and 33.40% in the control groups. Exophytic bone formation was significantly made in the test group more than in the control group. At 16 weeks after surgery, exophytic bone formation was made 44.11% in the test groups and 46.26% in the control groups. Exophytic bone formation was made in the test groups more than in the control groups, but there was no statistically significant differences. 3. The membrane was fixed with metal pins to closely contact it to the bone surface. So, collapse and deviation of the membrane could be prevented and in growth of connective tissue also could be blocked from the periphery of the membrane. On the basis of these findings, wee suggest that intraoral experimental model for exophytic bone formation may be effective to evaluate the effect of bone graft material. And it indicates that combined use of membrane and ICB graft material is more effective than use of membrane only for exophytic bone formation.

Study on light extraction efficiency of a side-etched LED (측면 식각된 LED의 광추출 효율에 관한 연구)

  • Noh, Y.K.;Kwon, K.Y.
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.2
    • /
    • pp.122-129
    • /
    • 2003
  • In the case of a AIGalnP/GaP system rectangular parallelepiped high brightness LED which has side walls etched to be slanted off the vertical direction, we have studied the effects of lossy electrodes and material absorption and etching depth and angle of side walls on its light extraction efficiency. If LEDs have no electrodes, in order to obtain an 80% light extraction efficiency of a TIP (truncated inverted pyramid) LED, the side-etched LEDs should have an etching angle of 22$^{\circ}$~45$^{\circ}$ and an etching depth of 8~17% of a dice height and an absorption coefficient less than 1 $cm^{-1}$ / In case of etching depth of 16~39% of a dice height, we can obtain a 90% light extraction efficiency of a TIP LED. But when LEDs have two electrodes and no absorption loss, in order to obtain an 80% light extraction efficiency of a TIP LEBs, the side-etched LEDs should have an etching angle of 25$^{\circ}$-45$^{\circ}$ and an etching depth of 30~36% of a dice height. In case of etching depth of 57~71% of a dice height, we can obtain a 90% light extraction efficiency of a TIP LED.

The Study on Foundation Remains(Jeoksim) According to Types of Buildings of Gyeongbok Palace (경복궁 건물 유형에 따른 적심 연구)

  • Choi, In Hwa
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.3
    • /
    • pp.154-175
    • /
    • 2009
  • At the present state, studies on Gyeongbok palace are being done with history of architecture, records, and art. However, these studies have limits that they can only depend on existing buildings and record, which make it hard to research whole aspect of palaces. The foundation remains(Jeoksim) of Gyeongbok palace in the ground gives important clues that can fill the gaps of these studies. Thus I analysed jeoksim of Gyeongbok palace, assorted them by type, scale, material, and construction method. I examined jeoksim used by various types of building, and looked at changes by periods. Jeoksims are classified in 21 types. The foundation(jeoksim) varies according to types of buildings, building types and material of jeoksim also varies along the periods, and the fact proves certain peroid of time has its own jeoksim style in fashion. Jeoksims of Gyeongbok palace are divided into round-shape(I), rounded square-shape(II), rectangular-shape(III), square-shape(IV), and whole foundation of building(V) by the plane shape. They can be divided again into 21 types by construction techniques and materials used. During early Joseon(I), only three types of jeoksim; round-shape riprap jeoksim(1-1), II-1(rounded square-shape), II-2a(rounded square-shape riprap+roofingingtile brick), had been built, but as 19th century begun, all 21 types of jeoksim had built. In 19th century during Emperor Gojong, different types of jeoksim by periods were built, and especially different materials were used. During Gojong year 2(1865)~year 5(1868), in which Gyeongbok palace were rebuilt, 7 out of 10 types of jeoksim used piece of roofinging tile and brick mixture, in contrast, during Gojong year 10(1873)~13(1876), or 25(1888), 3 out of 5 types of jeoksim used sandy soil with mixture of plaster. Meanwhile palace buildings have different names by the class of owner and use such as Jeon, Dang, Hap, Gak, Jae, Heon, Nu, and Jeong, which were classified by types and buildings were built according to each level. With an analysis of jeoksim by its building types, I ascertained that jeoksim were built differently in accordance to building types(Jeon, Dang, Hap, Gak, Jae, Heon, Nu, and Jeong). By the limitation of present document, only some types of buildings such as Jeon, Dang, Gak, Bang were confirmed, as for Jeon and Gak, square-shape(IV) built with rectangular parallelepiped stone, and for Dang and Bang, rounded square-shape(IV) built with roofinginginging tile and riprap were commonly used. From the fact that other jeoksim with uncertain building names, were mostly built in early Joseon, we learn that round-shape riprap jeoksim(1-1) were commonly built. Therefore, the class of building was higher if the owner was in higher class, jeoksim is also considered to be built with the strongest and best material. And for Dang and Bang, rounded square-shape jeoksim were used, Dang has lots of II-2a (riprap + piece of roofing tile and brick rounded square-shape) type which mainly used riprap and piece of roofing tile and brick, but Bang has lots of II-2b (piece of roofing tile and brick+(riprap+piece of roofing tile and brick rounded square-shape), which paved piece of roofing tile and brick by 15~20cm above. These jeoksim by building types were confirmed to have changed its construction type by period. As for Jeon and Gak, they were built with round-shape riprap jeoksim(1-1) in early Joseon(14~15c), but in late Joseon(19c), various types of Jeoksim were built, especially square-shape(IV) were commonly built. For Dang, only changes in later Joseon were confirmed, jeoksim built in Gojong year 4(1867) mostly used mixture of riprap and piece of roofing tile and brick. In Gojong year 13(1876) or year 25(1888), unique type of plaster with sand and coal and soil layered jeoksim were built that are not found in any other building types. Through this study, I learned that various construction types of jeoksim and material were developed in later Joseon compare to early Joseon. This states that construction technique of building foundation of palace has upgraded. Above all, I learned jeoksim types are all different for various kinds of buildings. This tells us that when they constructed foundation of building, they used pre-calculated construction technique.