• 제목/요약/키워드: Rectal volume

검색결과 91건 처리시간 0.026초

Correlation between tumor regression grade and rectal volume in neoadjuvant concurrent chemoradiotherapy for rectal cancer

  • Lee, Hong Seok;Choi, Doo Ho;Park, Hee Chul;Park, Won;Yu, Jeong Il;Chung, Kwangzoo
    • Radiation Oncology Journal
    • /
    • 제34권3호
    • /
    • pp.186-192
    • /
    • 2016
  • Purpose: To determine whether large rectal volume on planning computed tomography (CT) results in lower tumor regression grade (TRG) after neoadjuvant concurrent chemoradiotherapy (CCRT) in rectal cancer patients. Materials and Methods: We reviewed medical records of 113 patients treated with surgery following neoadjuvant CCRT for rectal cancer between January and December 2012. Rectal volume was contoured on axial images in which gross tumor volume was included. Average axial rectal area (ARA) was defined as rectal volume divided by longitudinal tumor length. The impact of rectal volume and ARA on TRG was assessed. Results: Average rectal volume and ARA were 11.3 mL and $2.9cm^2$. After completion of neoadjuvant CCRT in 113 patients, pathologic results revealed total regression (TRG 4) in 28 patients (25%), good regression (TRG 3) in 25 patients (22%), moderate regression (TRG 2) in 34 patients (30%), minor regression (TRG 1) in 24 patients (21%), and no regression (TRG0) in 2 patients (2%). No difference of rectal volume and ARA was found between each TRG groups. Linear correlation existed between rectal volume and TRG (p = 0.036) but not between ARA and TRG (p = 0.058). Conclusion: Rectal volume on planning CT has no significance on TRG in patients receiving neoadjuvant CCRT for rectal cancer. These results indicate that maintaining minimal rectal volume before each treatment may not be necessary.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy

  • 김종식;정천영;오동균;송기원;박영환
    • 대한방사선치료학회:학술대회논문집
    • /
    • 대한방사선치료학회 2005년도 춘계학술대회 초록집
    • /
    • pp.23-26
    • /
    • 2005
  • 재발한 vulva tumor의 근접 치료에 있어서 정상조직의 장애와 tumor volume내의 dose uniformity는 치료성적에 매우 중요한 요인이다. 이를 개선하기 위하여 modified MUPIT applicator를 제작하여 modified MUPIT applicator의 적용에 대한 유용성을 평가하고자 한다. modified MUPIT applicator는 template, cylinder, interstitial needle로 구성되었으며, tumor volume을 정하기 위하여 CT를 시행하였다. CT image를 이용하여 interstitial needle의 삽입 위치를 확인하고 수술실에서 template 를 치료 부위에 고정을 시키고 cylinder를 vaginal cavity에 삽입한 후 interstitial needle을 tumor volume 내에 삽입 하였다. tumor volume내에서 interstitial needle의 정확한 위치를 확인하기 위하여 CT를 시행하였으며 orthogonal film을 이용하여 computer planning을 실시하였다. daily tumor dose는 600 cGy, BID로 3000 cGy를 조사하였으며 치료 시 rectal dose를 평가하기 위하여 TLD를 이용하여 anal verge를 기준으로 5개 지점에서 rectal dose를 측정하였다. rectal dose는 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy로 측정되었으며 EBRT(whole pelvis RT), ICR과 overlap되는 지점은 34.1 cGy, 57.1 cGy로 매우 우수하게 평가되었다. 결론적으로 자체 제작한 modified MUPIT applicator 사용하여 interstitial brachytherapy를 시행함으로써 EBRT로 cover하기 어려운 환자의 tumor volume내에서 irregularity를 효율적으로 극복할 수 있었고 우수한 rectal dose 분포를 통하여 rectal complication의 발생 확률을 현저히 감소시킬 수 있었다.

  • PDF

Bladder filling variations during concurrent chemotherapy and pelvic radiotherapy in rectal cancer patients: early experience of bladder volume assessment using ultrasound scanner

  • Chang, Jee Suk;Yoon, Hong In;Cha, Hye Jung;Chung, Yoonsun;Cho, Yeona;Keum, Ki Chang;Koom, Woong Sub
    • Radiation Oncology Journal
    • /
    • 제31권1호
    • /
    • pp.41-47
    • /
    • 2013
  • Purpose: To describe the early experience of analyzing variations and time trends in bladder volume of the rectal cancer patients who received bladder ultrasound scan. Materials and Methods: We identified 20 consecutive rectal cancer patients who received whole pelvic radiotherapy (RT) and bladder ultrasound scan between February and April 2012. Before simulation and during the entire course of treatment, patients were scanned with portable automated ultrasonic bladder scanner, 5 times consecutively, and the median value was reported. Then a radiation oncologist contoured the bladder inner wall shown on simulation computed tomography (CT) and calculated its volume. Results: Before simulation, the median bladder volume measured using simulation CT and bladder ultrasound scan was 427 mL (range, 74 to 1,172 mL) and 417 mL (range, 147 to 1,245 mL), respectively. There was strong linear correlation (R = 0.93, p < 0.001) between the two results. During the course of treatment, there were wide variations in the bladder volume and every time, measurements were below the baseline with statistical significance (12/16). At 6 weeks after RT, the median volume was reduced by 59.3% to 175 mL. Compared to the baseline, bladder volume was reduced by 38% or 161 mL on average every week for 6 weeks. Conclusion: To our knowledge, this study is the first to prove that there are bladder volume variations and a reduction in bladder volume in rectal cancer patients. Moreover, our results will serve as the basis for implementation of bladder training to patients receiving RT with full bladder.

FIGO병기 IIB 자궁경부암에서 고선량 강내 방사선치료후의 후기 직장 합병증 (Late Rectal Complication in Patients treated with High Dose Rate Brachytherapy for Stage IIB Carcinoma of the Cervix)

  • 정은지;김귀언;서창옥;금기창;김우철
    • Radiation Oncology Journal
    • /
    • 제14권1호
    • /
    • pp.41-52
    • /
    • 1996
  • 목적 : 외부 방사선 치료(External Radiation Therapy) 및 Gamma-med (Iridium-192) 고선량 강내 방사선 치료를 받은 자궁 경부암 FIGO stage IIB 환자에서 직장 합병증 발생률 및 이와 관계있는 인자를 후향적으로 분석해 보았다. 대상 및 방법 : 1989년 11월부터 1992년 12월까지 연세암센터 치료방사선과에서 근치적 목적의 외부 및 강내 방사선치료를 받은 FIGO 병기 IIB 자궁경부암 환자 88명을 대상으로 방사선치료후 발생한 직장 합병증 및 이와 연관된 인자들을 분석하여 보았다. 환자들의 연령은 29-83세로 평균치, 중앙치 모두 57세였고 병리조직 분류상 편평상피세포암이 84예 선암이 4예였다. 방사선치료는 외부방사선을 골반 부위에 5-6주 동안 4500-5400cGy 치료하였으며 환자별로 중간 차폐를 시행하였고 고선량 Gamma-med ICR은 A점에 1회당 500cGy씩 1주 2회로 총 3000cGy 조사하였다. 외부 방사선치료시 중앙 차폐까지의 외부 조사량, ICR rectal dose(r) 및 total rectal dose(R), ICRU 38에 따른 ICR rectal dose(Dr)와 total Dr dose(OR), ICR reference volume, TDF, BED(Biologically Effective Dose)를 계산하고 분석해 합병증과의 연관성을 찾아보았다. 대상 환자 88명중 87명($98.9\%$)에서 최저 24개월 이상 추적 관찰이 가능하였으며 중앙치는 40개월(20-66개월)이었다. 결과 : 직장 합병증은 27예에서 발생하였는데($30.7\%$) grade 1이 12예($13.6\%$), 2가 12예($13.6\%$), 3이 3($3.4\%$)예였고 합병증이 발생하는 시기는 망사선치료후 4-43개월(중앙치 16개월, 평균 17.3개월)이었다. 직장 합병증이 발생하지 않은 환자군의 total rectal dose(R)는 $6772.67{\pm}884.02$로 grade 2-3 합병증이 발생한 15명의 R=$7163.0{\pm}838.49$와 유의한 차이를 보였으며 total Dr dose (DR)도 두 군간에 차이를 보였다 또 grade 2-3인 직장 합병증 발생률은 중앙 차폐시 까지의 외부 방사선량과 관계가 있었는데 36Gy이하에서는 $10\%$, 36-40Gy는 $21.4\%$, 40Gy 이상에서는 $29.3\%$의 직장 합병증이 발생하여 중앙 차폐까지 조사된 외부 방사선량이 증가할수록 직장 합병증이 증가함을 알 수 있었다. 직장에 조사된 총직장 조사량(R)에 따라 grade 2-3 합병증 발생률이 증가하였는데 65Gy 이하에서는 $10.5\%$, 65-75Gy는 $17.2\%$, 75Gy이상 조사된 환자군에서는 $28.5\%$로 조사량이 증가할수록 직장 합병증이 증가하는 알상이었으며 ICRU 38 에 따른 total rectal dose (DR)에 대해서도 비슷한 양상이었다. ICR rectal dose(r, Dr)만 따로 분석해 보았는데 방사선량과 직장 합병증간에는 차이가 없었다. 그 외의 인자로 분석한 TDF 와 BED도 grade 2-3의 경우에는 그 값이 증가할수록 증가하는 양상을 보였으나 통계적인 유의성은 없었고 Gamma Dot 에서 계산되는 ICR reference volume도 분석해 보았으나 합병증파의 연관성을 발견할 수 없었다. 결론 : 병기 IIB 자궁경부암 환자에서 외부 방사선치료 및 고선량 강내 방사선치료후 직장 합병증 발생률은 $30.7\%$(grade 2-3: 15예 $17\%$)였다. 직장 합병증 발생에 영향을 미치는 중요한 인자는 직장에 조사된 전골반 방사선량(중앙 차폐까지의 방사선량) 및 고선량 강내 방사선 치료와 합한 총직장 방사선량(r, Dr)으로 나타났으며 이들이 증가할수록 합병증 발생률이 증가하였다.

  • PDF

미나리 작업자를 위한 작업복 개발에 관한 연구 (Development the protective clothing for a dropworts cropping workers)

  • 최정화;백윤정
    • 한국의류학회지
    • /
    • 제24권8호
    • /
    • pp.1266-1275
    • /
    • 2000
  • This study was to research the actual condition of a dropworts working environment and to develope the clothing to reduce the work road. The actual conditions of working environment, working position and clothing were surveyed. Experiments were performed in the chamber and in the field. In the chamber, rectal temperature, 11 points skin temperatures(forehead, chest, abdomen, upperarm, forearm, dorsum manus, palm, thigh, calf, dorsum pedis and pelma), heart rates, microclimates inside clothing on the chest and subjective sensations were measured for comparing between 2 different types o garments. In the field, rectal temperature, abodomen skin temperature, 3 points microclimates inside clothing(chest, back and thigh), heart rates, the volume of EMG and subjective sensations were measured. The results were as follows; 1. There were no significant differences in rectal temperature between a old type protective clothing and a new type both in the chamber and the field. 2. Subjects wearing a old type clothing responded \"a little cold\", \"a little uncomfortable\" and subjects wearing a new type protective clothing responded \"normal\", \"comfortable\" both in the chamber and the field. 3. In the field test results, abodemen skin temperature in a old type clothing was higher and microtemperatures inside clothing of chest, back and thigh in a new type protective clothing were higher. 4. The volume of EMG was lower in the new type protective clothing than in the old one.protective clothing than in the old one.

  • PDF

재발한 Vulvar 종양의 근접치료 시 Modified Mupit Applicator의 적용 (Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy)

  • 김종식;정천영;오동균;송기원;박영환
    • 대한방사선치료학회지
    • /
    • 제18권1호
    • /
    • pp.13-19
    • /
    • 2006
  • 목 적: 재발한 vulva 종양의 근접 치료 시 정상조직의 장애와 종양 체적 내의 선량 균등도를 개선하기 위해 modified MUPIT applicator를 자체 고안하였으며 이에 대한 유용성을 평가하고자 한다. 대상 및 방법: Modified MUPIT applicator는 template, cylinder, interstitial needle로 구성 되었으며, 종양 체적을 정하기 위하여 치료 전 CT를 시행하였다. CT 영상을 이용하여 Interstitial needle의 삽입 위치를 결정하고, 수술실에서 template를 치료 부위에 고정을 시키고, cylinder를 vaginal cavity에 삽입한 후, interstitial needle을 종양 체적 내에 삽입하였다. 삽입된 interstitial needle의 정확한 위치를 확인하기 위하여 확인용 CT를 시행하였으며, simulation을 통하여 얻어진 orthogonal film을 이용하여 치료 계획을 수립하였다. 일일 종양 선량은 600 cGy, BID로 3,000 cGy를 조사하였으며, 치료 시 직장 선량을 평가하기 위하여 TLD를 이용하여 anal verge를 기준으로 5개 지점에서의 직장 선량을 측정하였다. 결 과: Modified MUPIT applicator 대한 유용성을 평가하기 위하여 측정된 직장 선량은 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy로 측정되었으며, 외부방사선치료(EBRT: External Beam Radiation Therapy), 강내방사선치료(ICR: Intracavitary radiotherapy)와 중첩되는 지점은 34.1 cGy, 57.1 cGy로 매우 우수하게 평가되었다. 결 론: 자체 제작한 modified MUPIT applicator 사용하여 조직 내 근접치료(Interstitial brachytherapy)를 시행함으로써, 외부방사선치료로 접근하기 어려운 종양에 대하여 선량 균등도를 효율적으로 개선할 수 있었고, 직장 선량을 최소화하여 직장의 부작용 발생 확률을 현저히 감소시킬 수 있었다.

  • PDF

복부판과 소장변위도구를 사용하는 직장암의 방사선치료 시 비만도가 소장의 조사용적에 미치는 영향 (The Effect of Obesity Levels on Irradiated Small Bowel volume in Belly Board with Small Bowel Displacement Device for Rectal Cancer Radiotherapy)

  • 김세영;김주호;박효국;조정희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권1호
    • /
    • pp.39-47
    • /
    • 2013
  • 본 연구의 목적은 방사선 조사 용적 내 포함되는 소장의 용적 감소를 위해 복부판(Belly board, 벨리보드)과 소장변위도구(Small Bowel Displacement Device, SBDD)를 사용한 직장암 환자에서 방사선 치료 영역 내 포함되는 소장의 용적과 비만도 와의 상관성을 보고, 비만지표의 적용을 통해 SBDD의 사용지표를 삼고자 한다. 실험은 2012년 1월부터 4월까지 수술 전 혹은 수술 후 벨리보드와 SBDD를 사용해 골반부위에 방사선치료를 받은 29명의 직장암 환자를 대상으로 분석하였다. 방사선 치료는 3문 조사로 시행하였으며 1.8 Gy의 분할선량으로 중심점에 45 Gy를 조사한 계획만을 분석하였다. 환자의 키, 몸무게, 체질량지수(body mass index, BMI), 허리 엉덩이 둘레비(waist hip ratio, WHR)를 측정하여 비만도를 조사하였다. 조사되는 선량의 90%이상 들어가는 소장의 용적(high dose volume of small bowel, $HDV_{sb}$)과 33%이상 들어가는 소장의 용적(low dose volume of small bowel, $LDV_{sb}$)을 방광의 총 용적(total volume of bladder, $TV_{bladder}$) 및 비만도에 따라 비교하여 그 상관관계를 통계학적으로 분석하였다. 분석결과 수술여부 및 성별 WHR은 $HDV_{sb}$, $LDV_{sb}$에 크게 미치는 영향이 없었고 $HDV_{sb}$, $LDV_{sb}$와 BMI(p=0.031/0.083), $TV_{bladder}$ (p<0.05)는 통계적으로 유의하였다. BMI가 $HDV_{sb}$와는 유의 하지만 $LDV_{sb}$와는 크게 유의하지 않았다. (p=0.031, p>0.05) BMI는 $HDV_{sb}$와 음의 상관관계(${\beta}$=-0.402)가 있었으며 $TV_{bladder}$$HDV_{sb}$, $LDV_{sb}$와 음의 상관관계(${\beta}$=-0.497/-0.522)가 있었다. 특히 BMI 23 미만인 경우(BMI Group2)보다 그 이상인 경우 $HDV_{sb}$에 영향을 미치며 음의 상관성(${\beta}$=-0.525)이 있었다.($LDV_{sb}$, $HDV_{sb}$와 유의확률 각각 p=0.059, p=0.027) BMI가 23 이상인 집단(BMI Group1)에서는 $TV_{bladder}$$HDV_{sb}$, $LDV_{sb}$가 통계학적으로 유의하였고(p<0.04) 음의 상관성을 보였다. 비만지표인 BMI가 23 이상인 과체중 및 비만군의 직장암 방사선 치료 시 벨리보드와 SBDD를 동시에 사용하는 경우 조사용적 내 포함되는 소장의 용적을 감소시키는데 더 효과적이었다. 그러므로 벨리보드를 사용하는 직장암의 방사선 치료 시 BMI 23 이상인 한국인 환자에게는 소장변위도구를 동시에 사용 할 것을 권장한다.

Interfraction variation and dosimetric changes during image-guided radiation therapy in prostate cancer patients

  • Fuchs, Frederik;Habl, Gregor;Devecka, Michal;Kampfer, Severin;Combs, Stephanie E.;Kessel, Kerstin A.
    • Radiation Oncology Journal
    • /
    • 제37권2호
    • /
    • pp.127-133
    • /
    • 2019
  • Purpose: The aim of this study was to identify volume changes and dose variations of rectum and bladder during radiation therapy in prostate cancer (PC) patients. Materials and Methods: We analyzed 20 patients with PC treated with helical tomotherapy. Daily image guidance was performed. We re-contoured the entire bladder and rectum including its contents as well as the organ walls on megavoltage computed tomography once a week. Dose variations were analyzed by means of Dmedian, Dmean, Dmax, V10 to V75, as well as the organs at risk (OAR) volume. Further, we investigated the correlation between volume changes and changes in Dmean of OAR. Results: During treatment, the rectal volume ranged from 62% to 223% of its initial volume, the bladder volume from 22% to 375%. The average Dmean ranged from 87% to 118% for the rectum and 58% to 160% for the bladder. The Pearson correlation coefficients between volume changes and corresponding changes in Dmean were -0.82 for the bladder and 0.52 for the rectum. The comparison of the dose wall histogram (DWH) and the dose volume histogram (DVH) showed that the DVH underestimates the percentage of the rectal and bladder volume exposed to the high dose region. Conclusion: Relevant variations in the volume of OAR and corresponding dose variations can be observed. For the bladder, an increase in the volume generally leads to lower doses; for the rectum, the correlation is weaker. Having demonstrated remarkable differences in the dose distribution of the DWH and the DVH, the use of DWHs should be considered.

3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰 (A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient)

  • 서정남;나종억;배선명;정동민;윤인하;배재범;곽정원;백금문
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.53-60
    • /
    • 2015
  • 목 적 : 본 연구는 3D 프린터를 이용하여 전립샘부위 팬텀을 제작하고 생체내선량측정(In-vivo dosimetry)을 통해 그 유용성을 평가하고자 한다. 대상 및 방법 : 전립샘암 환자의 3차원 치료체적을 바탕으로 3D 프린터(3D EDISON+, Lokit, KOREA)를 이용하여 전립샘과 직장의 체적을 동일하게 모사한 팬텀을 제작하고, 컴퓨터단층촬영(Lightspeed CT, GE, USA)을 통해 팬텀영상을 획득하였다. 전립샘암 환자의 체적과 팬텀의 체적을 비교 한 후, 전산화치료계획시스템(Eclipse version 10.0, Varian, USA)을 이용하여 치료계획을 설계하였다. 팬텀 내 측정지점인 방광(Bladder), 전립샘(Prostate), 직장 위벽(Rectal anterior wall), 직장 아래벽(Rectal posterior wall)의 임의의 지점에 모스펫검출기(Metal OXIDE Silicon Field Effect Transistor, MOSFET)를 위치시켜 선량 측정값과 치료계획을 비교분석 하였다. 결 과 : 전립샘과 직장풍선의 환자체적은 각각 30.61 cc, 52.19 cc 이고, 팬텀체적은 31.12 cc, 53.52 cc로 각 체적의 차이는 3% 미만으로 확인되었다. 모스펫검출기의 정밀도는 3%이내로 측정되었고 선량의 변화에 따라 상관계수 R2 = 0.99 ~ 1.00 의 선형성을 보였다. 네 곳의 측정 지점을 치료계획된 선량과 비교한 결과 방광 1.4%, 전립샘 2.6%, 직장 위벽 3.7%, 직장 아래벽 1.5%로 나타났고 모스펫검출기의 정밀도를 고려한 선량측정의 정확성은 5% 이내로 평가되었다. 결 론 : 본 실험을 통해 3D 프린터를 이용하여 제작한 전립샘 부위 팬텀은 체적의 차이 3% 미만으로, 인체를 모사하는데 효과적으로 사용될 수 있음을 확인하였다. 제작된 팬텀을 이용한 생체내선량측정은 모스펫검출기의 정밀도를 고려하더라도 방광, 전립샘, 직장 위벽, 직장 아래벽의 모든 측정점에서 5% 이내의 정확도로 수행 할 수 있었다. 따라서 3D 프린트를 이용해 제작된 전립샘 부위 팬텀은 생체선량측정을 하는데 있어 매우 유용하였으며 향후 환자에게 직접 적용하기 어려운 부위를 팬텀으로 대체 제작하여 생체내선량측정이 가능할 것으로 사료된다.

  • PDF

Internal Changes of Blood Compartment and Heat Distribution in Swamp Buffaloes under Hot Conditions : Comparative Study of Thermo-Regulation in Buffaloes and Friesian Cows

  • Koga, A.;Kurata, K.;Ohata, K.;Nakajima, M.;Hirose, H.;Furukawa, R.;Kanai, Y.;Chikamune, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권6호
    • /
    • pp.886-890
    • /
    • 1999
  • From previous studies, there is a strong possibility in buffaloes that the marked increase in blood volume (BV) under hot conditions contributes to heat transportation from the rectum to the skin. The present study was done to clarify changes with environmental temperature on water-shift between blood and extracellular fluid (ECF), heat distribution between the rectum and the skin, and blood flow rates (BFR) at the hind legs (reflecting the skin surface). Four buffaloes and four Friesian cows were successively exposed to three different temperatures of $20^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$. BV and ECF volume were measured with Evans' blue and sodium-thiocyanate dilution methods, respectively. Rectal and subcutaneous (as the skin) temperatures were measured by copper-constantan thermocouples. BFR were measured by a supersonic blood flow meter. With an increase in environmental temperature, skin temperature in buffaloes increased significantly than cows, but rectal temperature was not significantly different between two species. BV, especially plasma compartment, increased significantly in only buffaloes, while ECF volume did not change in both species. BFR increased significantly in buffaloes, but not in cows. From these results, the increased of BV may be caused by water flowing from ECF compartment. The water-shift may induce the increase of BFR and skin temperature. It is suggested in the present study that internal changes of blood compartment in buffaloes contribute to transfer of heat to the skin surface.