Purpose: To determine whether large rectal volume on planning computed tomography (CT) results in lower tumor regression grade (TRG) after neoadjuvant concurrent chemoradiotherapy (CCRT) in rectal cancer patients. Materials and Methods: We reviewed medical records of 113 patients treated with surgery following neoadjuvant CCRT for rectal cancer between January and December 2012. Rectal volume was contoured on axial images in which gross tumor volume was included. Average axial rectal area (ARA) was defined as rectal volume divided by longitudinal tumor length. The impact of rectal volume and ARA on TRG was assessed. Results: Average rectal volume and ARA were 11.3 mL and $2.9cm^2$. After completion of neoadjuvant CCRT in 113 patients, pathologic results revealed total regression (TRG 4) in 28 patients (25%), good regression (TRG 3) in 25 patients (22%), moderate regression (TRG 2) in 34 patients (30%), minor regression (TRG 1) in 24 patients (21%), and no regression (TRG0) in 2 patients (2%). No difference of rectal volume and ARA was found between each TRG groups. Linear correlation existed between rectal volume and TRG (p = 0.036) but not between ARA and TRG (p = 0.058). Conclusion: Rectal volume on planning CT has no significance on TRG in patients receiving neoadjuvant CCRT for rectal cancer. These results indicate that maintaining minimal rectal volume before each treatment may not be necessary.
Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
대한방사선치료학회:학술대회논문집
/
2005.06a
/
pp.23-26
/
2005
Introduction: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Methods and Materials: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator , an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was performed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS (192-Ir HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3000cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Result: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1cGy, 57.1cGy, 103.8cGy, 162.7cGy, 165.7cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1cGy, 57.1cGy Conclusion: Patients with locally recurrent tumor in uterine cervix cancer treated with modified MIUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry Provided by the template and cylinders, and improved dose distributions in irregular tumor volume without rectal complication
Chang, Jee Suk;Yoon, Hong In;Cha, Hye Jung;Chung, Yoonsun;Cho, Yeona;Keum, Ki Chang;Koom, Woong Sub
Radiation Oncology Journal
/
v.31
no.1
/
pp.41-47
/
2013
Purpose: To describe the early experience of analyzing variations and time trends in bladder volume of the rectal cancer patients who received bladder ultrasound scan. Materials and Methods: We identified 20 consecutive rectal cancer patients who received whole pelvic radiotherapy (RT) and bladder ultrasound scan between February and April 2012. Before simulation and during the entire course of treatment, patients were scanned with portable automated ultrasonic bladder scanner, 5 times consecutively, and the median value was reported. Then a radiation oncologist contoured the bladder inner wall shown on simulation computed tomography (CT) and calculated its volume. Results: Before simulation, the median bladder volume measured using simulation CT and bladder ultrasound scan was 427 mL (range, 74 to 1,172 mL) and 417 mL (range, 147 to 1,245 mL), respectively. There was strong linear correlation (R = 0.93, p < 0.001) between the two results. During the course of treatment, there were wide variations in the bladder volume and every time, measurements were below the baseline with statistical significance (12/16). At 6 weeks after RT, the median volume was reduced by 59.3% to 175 mL. Compared to the baseline, bladder volume was reduced by 38% or 161 mL on average every week for 6 weeks. Conclusion: To our knowledge, this study is the first to prove that there are bladder volume variations and a reduction in bladder volume in rectal cancer patients. Moreover, our results will serve as the basis for implementation of bladder training to patients receiving RT with full bladder.
Purpose : This paper reports a dosimetric study of 88 patients treated with a combination of external radiotherapy and high dose rate ICR for FIGO stage IIB carcinoma of the cervix. The purpose is to investigate the correlation between the radiation doses to the rectum, external radiation dose to the whole pelvis, ICR reference volume, TDF BED and the incidence of late rectal complications, retrospectively. Materials and Methods : From November 1989 through December 1992, 88 patients with stage IIB cervical carcinoma received radical radiotherapy at Department of Radiation Oncology in Yonsei University Hospital. Radiotherapy consisted of 44-54 Gy(median 49 Gy) external beam irradiation plus high dose rate intracavitary brachytherapy with 5 Gy per fraction twice a week to a total dose of 30 Gy on point A. The maximum dose to the rectum by contrast(r, R) and reference rectal dose by ICRU 38(dr, DR) were calculated. The ICR reference volume was calculated by Gamma Dot 3.11 HDR planning system, retrospectively The time-dose factor(TDF) and the biologically effective dose (BED) were calculated. Results : Twenty seven($30.7\%$) of the 88 patients developed late rectal complications:12 patients($13.6\%$) for grade 1, 12 patients($13.6\%$) for grade 2 and 3 patients($3.4\%$) for grade 3. We found a significant correlation between the external whole pelvis irradiation dose and grade 2, 3 rectal complication. The mean dose to the whole pelvis for the group of patients with grade 2, 3 complication was Higher, $4093.3\pm453.1$ cGy, than that for the patients without complication, $3873.8\pm415.6$ (0.05
$7163.0\pm838.5$ cGy, than that for the Patients without rectal complication, $0772.7\pm884.0$ (p<0.05). There was no correlation of the rate of grade 2, 3 rectal complication with the iCR rectal doses(r, dr), ICR reference volume, TDF and BED. Conclusion : This investigation has revealed a significant correlation between the dose calculated at the rectal dose by ICRU 38(DR) or the most anterior rectal dose by contrast(R) dose to the whole pelvis and the incidence of grade 2, 3 late rectal complications in patients with stage IIB cervical cancer undergoing external beam radiotherapy and HOR ICR. Thus these rectal reference points doses and whole pelvis dose appear to be useful Prognostic indicators of late rectal complication in high dose rate ICR treatment in cervical carcinoma.
Journal of the Korean Society of Clothing and Textiles
/
v.24
no.8
/
pp.1266-1275
/
2000
This study was to research the actual condition of a dropworts working environment and to develope the clothing to reduce the work road. The actual conditions of working environment, working position and clothing were surveyed. Experiments were performed in the chamber and in the field. In the chamber, rectal temperature, 11 points skin temperatures(forehead, chest, abdomen, upperarm, forearm, dorsum manus, palm, thigh, calf, dorsum pedis and pelma), heart rates, microclimates inside clothing on the chest and subjective sensations were measured for comparing between 2 different types o garments. In the field, rectal temperature, abodomen skin temperature, 3 points microclimates inside clothing(chest, back and thigh), heart rates, the volume of EMG and subjective sensations were measured. The results were as follows; 1. There were no significant differences in rectal temperature between a old type protective clothing and a new type both in the chamber and the field. 2. Subjects wearing a old type clothing responded \"a little cold\", \"a little uncomfortable\" and subjects wearing a new type protective clothing responded \"normal\", \"comfortable\" both in the chamber and the field. 3. In the field test results, abodemen skin temperature in a old type clothing was higher and microtemperatures inside clothing of chest, back and thigh in a new type protective clothing were higher. 4. The volume of EMG was lower in the new type protective clothing than in the old one.protective clothing than in the old one.
Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
The Journal of Korean Society for Radiation Therapy
/
v.18
no.1
/
pp.13-19
/
2006
Purpose: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Materials and Methods: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator, an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was peformed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS(192-lr HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3,000 cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Results: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1 cGy, 57.1 cGy. Conclusion: Patients with locally recurrent tumor in uterine cervix cancel treated with modified MUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry provided by the template and cylinders. and improved dose distributions in irregular tumor volume without rectal complication.
Kim, Se-Young;Kim, Joo-Ho;Park, Hyo-Kuk;Cho, Jeong-Hee
Journal of radiological science and technology
/
v.36
no.1
/
pp.39-47
/
2013
For radiotherapy in rectal cancer patients treated with small bowel displacement device (SBDD) and belly board, We will suggest new indication of using SBDD depending on obesity index by analyzing correlation between obesity and irradiated small bowel volume. In this study, We reviewed 29 rectal cancer patients who received pelvic radiation therapy with belly board and SBDD from January to April in 2012. We only analyzed those patients treated with three-field technique (PA and both LAT) on 45 Gy (1.8 Gy/fx). We measured patients' height, weight, body mass index (BMI), waist-hip ratio (WHR) and divided BMI into two groups.(${\geq}23$:BMI=group1, <23:BMI=group2) We performed a statistical analysis to evaluate correlation between total volume of bladder($TV_{bladder}$), obesity index and high dose volume of small bowel (small bowel volume irradiated at 90% of prescribed dose, $HDV_{sb}$), low dose volume of small bowel (small bowel volume irradiated at 33% of prescribed dose, $LDV_{sb}$). The result shows, gender, WHR and status of pre operative or post operative do not greatly affect $HDV_{sb}$ and $LDV_{sb}$. Statistical result shows, there are significant correlation between $HDV_{sb}$ and BMI (p<0.04), $HDV_{sb}$ and $TV_{bladder}$ (p<0.01), $LDV_{sb}$ and $TV_{bladder}$ (p<0.01). BMI seems to correlate with $HDV_{sb}$ but does not with $LDV_{sb}$ (p>0.05). There are negative correlation between $HDV_{sb}$ and BMI, $TV_{bladder}$ and $HDV_{sb}$, $TV_{bladder}$ and $LDV_{sb}$. Especially, BMI group1 has more effective and negative correlation with $HDV_{sb}$ (p=0.027) than in BMI group2. In the case of BMI group 1, $TV_{bladder}$ has significant negative correlation with $HDV_{sb}$ and $LDV_{sb}$ (p<0.04). In conclusions, we confirmed that Using SBDD with belly board in BMI group1 could more effectively reduce irradiated small bowel volume in radiation therapy for rectal cancer. Therefore, We suggest using belly board with SBDD in order to reduce the small bowel toxicity in rectal radiotherapy, if patients' BMI is above 23.
Fuchs, Frederik;Habl, Gregor;Devecka, Michal;Kampfer, Severin;Combs, Stephanie E.;Kessel, Kerstin A.
Radiation Oncology Journal
/
v.37
no.2
/
pp.127-133
/
2019
Purpose: The aim of this study was to identify volume changes and dose variations of rectum and bladder during radiation therapy in prostate cancer (PC) patients. Materials and Methods: We analyzed 20 patients with PC treated with helical tomotherapy. Daily image guidance was performed. We re-contoured the entire bladder and rectum including its contents as well as the organ walls on megavoltage computed tomography once a week. Dose variations were analyzed by means of Dmedian, Dmean, Dmax, V10 to V75, as well as the organs at risk (OAR) volume. Further, we investigated the correlation between volume changes and changes in Dmean of OAR. Results: During treatment, the rectal volume ranged from 62% to 223% of its initial volume, the bladder volume from 22% to 375%. The average Dmean ranged from 87% to 118% for the rectum and 58% to 160% for the bladder. The Pearson correlation coefficients between volume changes and corresponding changes in Dmean were -0.82 for the bladder and 0.52 for the rectum. The comparison of the dose wall histogram (DWH) and the dose volume histogram (DVH) showed that the DVH underestimates the percentage of the rectal and bladder volume exposed to the high dose region. Conclusion: Relevant variations in the volume of OAR and corresponding dose variations can be observed. For the bladder, an increase in the volume generally leads to lower doses; for the rectum, the correlation is weaker. Having demonstrated remarkable differences in the dose distribution of the DWH and the DVH, the use of DWHs should be considered.
Seo, Jung Nam;Na, Jong Eok;Bae, Sun Myung;Jung, Dong Min;Yoon, In Ha;Bae, Jae Bum;Kwack, Jung Won;Baek, Geum Mun
The Journal of Korean Society for Radiation Therapy
/
v.27
no.1
/
pp.53-60
/
2015
Purpose : The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. Materials and Methods : The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are aquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Results : Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 ~ 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. Conclusion : By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional phantom production by a 3D printer and In-vivo dosimetry for other organs of patient.
Koga, A.;Kurata, K.;Ohata, K.;Nakajima, M.;Hirose, H.;Furukawa, R.;Kanai, Y.;Chikamune, T.
Asian-Australasian Journal of Animal Sciences
/
v.12
no.6
/
pp.886-890
/
1999
From previous studies, there is a strong possibility in buffaloes that the marked increase in blood volume (BV) under hot conditions contributes to heat transportation from the rectum to the skin. The present study was done to clarify changes with environmental temperature on water-shift between blood and extracellular fluid (ECF), heat distribution between the rectum and the skin, and blood flow rates (BFR) at the hind legs (reflecting the skin surface). Four buffaloes and four Friesian cows were successively exposed to three different temperatures of $20^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$. BV and ECF volume were measured with Evans' blue and sodium-thiocyanate dilution methods, respectively. Rectal and subcutaneous (as the skin) temperatures were measured by copper-constantan thermocouples. BFR were measured by a supersonic blood flow meter. With an increase in environmental temperature, skin temperature in buffaloes increased significantly than cows, but rectal temperature was not significantly different between two species. BV, especially plasma compartment, increased significantly in only buffaloes, while ECF volume did not change in both species. BFR increased significantly in buffaloes, but not in cows. From these results, the increased of BV may be caused by water flowing from ECF compartment. The water-shift may induce the increase of BFR and skin temperature. It is suggested in the present study that internal changes of blood compartment in buffaloes contribute to transfer of heat to the skin surface.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.