• Title/Summary/Keyword: Recovery angle

Search Result 280, Processing Time 0.028 seconds

A Study for Optimal Design of the AIG to Improve the Performance of DeNOx Facilities Installed in Combined Cycle Plant (복합화력 탈질설비 성능향상을 위한 암모니아 주입 그리드의 최적설계 방안에 관한 연구)

  • Kim, Kwang-Chu;Park, Man-Heung;Yoon, Jun-Kyu;Lim, Jong-Han
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.811-820
    • /
    • 2007
  • A Study on the optimal design of the AIG(Ammonia Injection Grid) to improve the performance of DeNOx facilities in the HRSG(Heat Recovery Steam Generator) was performed using the CFD analysis. On the basis of the flow analysis results in the case that the AIG in the HRSG was not installed, the numerical analyses according to the positions of AIG, injection angles of nozzle and the control of ammonia injection quantity were carried out. The standard deviation according to factors was calculated for quantitative comparison. As the results, the AIG in the HRSG should be installed in the position that the uniform flow field shows through the exact flow analysis in the previous of the AIG design and installation. In the case the AIG has already been installed and non uniform flow distribution shows, it is recommended that flow correction device or KoNOx catalyst should be used. Otherwise, the control of ammonia injection angle or the ammonia injection quantity using the velocity profile analysis is demanded to accomplish the optimal performance.

Relation between Surface degradation and Anti-pollution Characteristics in RTV Silicone Rubber (RTV 실리콘 고무의 표면열화와 내오손 특성과의 상관관계)

  • 연복희;이태호;허창수;이상엽
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.598-606
    • /
    • 2000
  • In this paper we investigated the relation between the surface degradations and anti-pollution characteristics of Room Temperature Vulcanized(RTV) silicone rubber coating that has different roughness through immersing into saline water. We utilized several analytic techniques such as atomic force microscopy(AFM) scaning electron microscopy(SEM) contact angle Salt Deposit Density(SDD) and average leakage current under the condition of salt fog. It is found that the surface roughness of treated RTV silicone rubber increased and the hydrophobicity of sample surface decreased with increasing the duration o immersion into water due to the erosion of base polymer the melting down alumina trihydrate(ATH) and the diffusion of Low Molecular weight(LMW) fluid. Despite the roughness of surface had been increased by water immersion excellant anti-pollution and recovery characteristics were maintained and SDD saturated to 0.1~0.14mg/cm$^2$. The average leakage current under salt fog increased with surface roughness. Measurement of average leakage current will be helpful to investigate surface degradation and lifetime expectation of RTV silicone coating.

  • PDF

Minimization of Residual Stress of the Steel Cord for the Tire-reinforcement Using Finite Element Analysis (유한요소해석을 이용한 타이어 보강재용 스틸코드의 잔류응력 최소화)

  • Lee, Jong-Sup;Huh, Hoon;Lee, Jun-Wu;Lee, Byung-Ho
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.201-204
    • /
    • 2008
  • In this paper, several process parameter studies of the manufacturing process of the steel cords are carried out to verify the relation between the process parameters and the residual stresses on the steel cords. At first, the finite element analysis of the drawing process is performed and the residual stress distributions with respect to the wire material and the area reduction ratio are obtained. The residual stress of the drawn wire is imported the finite element analysis of the twisting process as an initial stress. After that a parameter study of the twisting process is carried out. The process parameters are the applied tension, the over-twisting angle and the tensile strength of the drawn wire. Based on these studies, the optimum values of the process parameters which can remove or reduce the undesired residual stresses are determined. The optimum value of the process parameters are confirmed by the finite element analysis of the elastic recovery process of the steel cords. Finally, the finite element analysis of the roller straightening process is done to study the variation of the distribution of the residual stress before and after the process.

  • PDF

A Study for Hip Joint in Children with Cerebral Palsy (뇌성마비 아동의 엉덩관절에 관한 연구)

  • Oh, Tae-young
    • The Journal of Korean Society for Neurotherapy
    • /
    • v.22 no.3
    • /
    • pp.43-48
    • /
    • 2018
  • Purpose The purpose of this study is to identify the prevalence, risk factors, characteristics, and interventions of hip joint problems in children with cerebral palsy, and to be able to serve as leverage for early detection, prevention, and function recovery. Method The electronic journal site was searched by the search terms "cerebral palsy", "hip joint", "hip joint dislocation", we analyzed and descript the cited articles from domestic and foreign papers in Pubmed 9, Science Direct 7, and K RISS analysis and analysis. Results Children with cerebral palsy showed the different prevalence according to their disability type, severity, and functional level, and we knew that abnormal neuromuscular control, stiffness, and biomechanical changes could be risk factors. Migration Index, Acetabolum Index, Neck shaft angle using by radiography and passive ROM test, special tests were available for the diagnosis and evaluation of the hip joint. Combination of physical therapy and orthopedic surgery was very important intervention, and complementary alternative therapy, orthosis, and postural assistant are effective. Conclusion We suggested that early detection and prevention is the most important periodic examination and that a multidisciplinary approach is a major factor in intervention.

Gait Recovery Characteristic According to the Injury Aspect of Descending Motor Pathway in a Chronic Stroke Patient: a Case Study

  • Sang Seok Yeo
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.6
    • /
    • pp.326-331
    • /
    • 2022
  • Purpose: The stroke patients have gait dysfunction due to impaired neural tracts; corticospinal tract (CST), corticoreticular pathway (CRP), and vestibulospinal tract (VST). In this study, we investigated characteristics of gait pattern according to the injury aspect of the neural track in a stroke patient. Methods: One patient and six control subjects of similar age participated. A 19-year-old male patient with spontaneous intracerebral hemorrhage on right basal ganglia, thalamus, corona radiata and cerebral cortex due to arteriovenous malformation rupture. Diffusion tensor imaging (DTI) data was acquired 21 months after the stroke. Kinematic and spatio-temporal parameters of gait were collected using a three-dimensional gait analysis system. Results: On 21 months DTI, the CST and CRP in affected hemisphere showed severe injury, in contrast, the VST in affected hemisphere showed intact integrity. Result of gait analysis, walking distance and speed were significantly decreased in a patient. The stance rate of unaffected lower limb, the swing rate of affected lower limb and the duration of double stance significantly increased compared with normal control. The knee and hip joint angle were significantly decreased in a patient. Conclusion: We found recovered independent gait ability may be associated with unimpaired VST in a patient with severe injury in CST and CRP.

The Results of the Endoscopic Decompression for the Treatment of Haglund's Disease (Haglund씨 병에서 시행한 내시경적 감압술의 결과)

  • Ahn, Su-Han;Cho, Hyung-Lae;Hong, Seong-Hwak;Wang, Tae-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.197-202
    • /
    • 2008
  • Purpose: Haglund's disease represents a painful heel caused by mechanically induced inflammation of the retrocalcaneal bursa and insertional Achilles tendinosis may coexist. Traditional open surgery can cause complications such as skin breakdown, painful scar and altered sensation around the heel. Endoscopic treatment offers the advantages that are related to minimally invasive procedure and we evaluate the clinical results and operative techniques of endoscopic decompression of retrocalcaneal space for Haglund's disease. Materials and Methods: Our retrospective study included seven heels in six consecutive patients for which nonoperative treatment had failed and endoscopic decompression was performed. The mean age was forty-one years (range, 28 to 53 years). All of the patients had typical complaints of inflammation of the retrocalcaneal bursa and Fowler-Philip angle of more than $75^{\circ}$ and positive parallel pitch lines were present on the lateral calcaneal radiograph. The endoscopic procedure consists of the resection of inflamed retrocalcaneal bursa and enough bone to prevent impingement of the bursa between the calcaneus and Achilles tendon. All patients were evaluated with radiologic angle, visual analogue scale (VAS) for pain and Ogilvie-Harris functional score. The mean follow-up was 18 months (range, 15 to 21 months). Results: The mean operation time was 61 minutes (range, 50 to 85 minutes). VAS for pain and Fowler-Philip angle were decreased from preoperative 8.7 and $82^{\circ}$ to postoperative 2.3 and $57^{\circ}$, respectively. One patient with ankylosing spondylitis had a fair result, 2 patients had good results and the remaining 3 patients had excellent results according to Ogilvie-Harris functional score. There were no surgical complications such as infection, Achilles tendon avulsion or abnormal heel sensation. Conclusion: The endoscopic decompression for Haglund's disease was demonstrated to have several advantages including low morbidity, allowance of functional rehabilitation, short recovery time and quick sports resumption. However a comparative study is needed to determine the value of endoscopic decompression and particular caution should be exerted for the enthesiopathy.

  • PDF

Implementation of Gait Analysis System Based on Inertial Sensors (관성센서 기반 보행 분석 시스템 구현)

  • Cho, J.S.;Kang, S.I.;Lee, K.H.;Jang, S.H.;Kim, I.Y.;Lee, J.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 2015
  • In this paper, we present an inertial sensor-based gait analysis system to measure and analyze lower-limb movements. We developed an integral AHRS(Attitude Heading Reference System) using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE(Root Mean Square Error) of 1.08 and 1.72 degree in yaw and pitch angle. In order to evaluate the performance of our the gait analysis system, we compared the joint angle for the hip, knee and ankle with those provided by Vicon system. The result shows that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limb or gait analysis during the post-stroke recovery.

  • PDF

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

Pain Recovery Pattern According to the Integrity after an Arthroscopic Rotator Cuff Repair (관절경하 회전근 개 봉합술 후 파열 정도에 따른 통증 회복 양상)

  • Kim, Ju-O;Sim, Sang-Don;Noh, Kyung-Hwan;Shon, Suk-June;Kim, Sul-Jun;Yang, Yun-Hyeok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.155-160
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the pain recovery pattern according to the integrity and to analyze the factors affecting the progress and level of pain postoperatively. Materials and Methods: We examined 153 patients, who were treated with arthroscopic rotator cuff repair. 101 rotator cuff tears were full-thickness tear and 52 were partial tear. The mean follow up duration was 20 months (12~30 months). We evaluated the visual analogue scale, range of motion, ASES (American Shoulder and Elbow Surgeons), and UCLA (University of California at Los Angeles) scores preoperatively and postoperatively. We analyzed the pain recovery pattern between partial and full thickness tear using Student T-test and the factors affecting the progress and level of postoperative pain using multiple regression analysis. Results: The change patterns of visual analogue scale after arthroscpoic repair were similar regardless of the tear integrity. The VAS showed a continuous decreasing pattern, but increased at first 3 weeks postoperatively and at 7 weeks postoperatively, and then, decreased thereafter. The average VAS was ${\leqq}2$ points by postoperative 3 months. The factor affecting the pain score at 3 months was related to the preoperative limitation in forward flexion ($r^2=0.377$, p=0.021). Conclusion: There was no differences of the pain recovery pattern according to the integrity, and the factor affecting the progress of postoperative pain was preoperative angle of forward elevation. So, the appropriate preoperative rehabilitation protocol that can improve motions of the shoulder joint would help to improve the level of postoperative pain and functional recovery.

  • PDF

Cold Tolerance of Native and Introduced Evergreen Rhododendron Species According to Morphological and Physiological Changes (국내 자생종 및 도입종 만병초의 내한성과 관련된 형태 및 생리적변화)

  • Lee, Byung-Chul;Kim, Seong-Min;Cheng, Hyo-Cheng;Shim, Ie-Sung
    • Horticultural Science & Technology
    • /
    • v.29 no.6
    • /
    • pp.561-567
    • /
    • 2011
  • Cold tolerance of the native Rhododendron species which are on the verge of extinction in Korean nature were compared with the introduced species and its mechanism were studied physiologically with the investigation of the leaf angle, leaf curling, and photosynthetic activity. The degree of cold tolerance measured with the leaf burning after winter season was higher in the native species, Rhododendron brachycarpum and Rhododendron brachycarpum var. roseum than all the introduced species. 'Nova Zembla', an introduced species, showed high sensitivity to the low temperature. Changes in leaf angle by the low temperature were bigger in 2 native species and 'Parker's Pink' than the other introduced species and small comparatively in 'Nova Zembla' and 'Cunningham's White' cultivar. Leaf curling also occurred strongly in 2 native species by the low temperature. While, it was comparatively little and mild in the other introduced species. Therefore these results suggested that the leaf movement such as leaf angle change and curling adapted to the low temperature is positively related to the cold tolerance of 2 native species. By the way, such relationship is not explainable in the cold-sensitive 'Parker's Pink' cultivar showing comparatively stronger leaf movement. Photosynthetic activity measured before the winter season was high in the cold-tolerant R. brachycarpum and its recovery after winter season was faster in the 2 native species and the introduced 'Cynosure' cultivar than the other introduced species. They were the lowest in the most cold-sensitive 'Nova Zembla'. This phenomena occurred similarly even in the stomatal conductivity, suggesting that the movement of water from the roots to the leaves is better and then the leaf burning after winter season become small in the cold-tolerant species. The recovery of photosynthetic activity and stomatal conductivity was comparatively slower in the cold-sensitive 'Parker's Pink'. From the above results, leaf behavior adapted to the low temperature during the winter season and water movement to the leaves are related collectively to the cold tolerance represented as the leaf burning in the Rhododendron species is suggested.