• Title/Summary/Keyword: Recovery Scale

Search Result 924, Processing Time 0.034 seconds

Large Scale Failure Adaptive Routing Protocol for Wireless Sensor Networks (무선 센서 네트워크를 위한 대규모 장애 적응적 라우팅 프로토콜)

  • Lee, Joa-Hyoung;Seon, Ju-Ho;Jung, In-Bum
    • The KIPS Transactions:PartA
    • /
    • v.16A no.1
    • /
    • pp.17-26
    • /
    • 2009
  • Large-scale wireless sensor network are expected to play an increasingly important role for the data collection in harmful area. However, the physical fragility of sensor node makes reliable routing in harmful area a challenging problem. Since several sensor nodes in harmful area could be damaged all at once, the network should have the availability to recover routing from node failures in large area. Many routing protocols take accounts of failure recovery of single node but it is very hard these protocols to recover routing from large scale failures. In this paper, we propose a routing protocol, which we refer to as LSFA, to recover network fast from failures in large area. LSFA detects the failure by counting the packet loss from parent node and in case of failure detection LSFAdecreases the routing interval to notify the failure to the neighbor nodes. Our experimental results indicate clearly that LSFA could recover large area failures fast with less packets than previous protocols.

Improved postoperative recovery profile in pediatric oral rehabilitation with low-dose dexmedetomidine as an opioid substitute for general anesthesia: a randomized double-blind clinical trial

  • Naveen, Naik B;Jaiswal, Manoj Kumar;Ganesh, Venkata;Singh, Ajay;Meena, Shyam Charan;Amburu, Vamsidhar;Soni, Shiv Lal
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.5
    • /
    • pp.357-367
    • /
    • 2022
  • Background: Low-dose dexmedetomidine may be a suitable alternative to opioids for pediatric ambulatory procedures under general anesthesia (GA). However, the recovery profile remains unclear. Herein, we aimed to evaluate the effects of low-dose dexmedetomidine on the recovery profile of children. Methods: Seventy-two children undergoing ambulatory oral rehabilitation under GA were randomly and equally distributed into two groups (D and F). Group D received an infusion of dexmedetomidine 0.25 ㎍/kg for 4 min for induction, followed by maintenance of 0.4 ㎍/kg/h. Group F received an infusion of fentanyl 1 ㎍/kg over 4 min for induction, followed by maintenance at 1 ㎍/kg/h. The primary outcome was the extubation time. The secondary outcomes were awakening time, end-tidal sevoflurane (ET-Sevo) requirement, change in hemodynamic parameters, Richmond Agitation-Sedation Scale (RASS), Children's Hospital of Eastern Ontario pain scale (CHEOPS) score, length of PACU stay, and incidence of adverse events. Results: Statistically significant differences were observed in the recovery profile between the groups: the median time for extubation was 3.65 (3.44-6.2) vs. 6.25 (4.21-7) minutes in groups D vs. F (P=0.001), respectively, while the corresponding awakening times were 19 (18.75-21) and 22.5 (22-24) minutes, respectively (P < 0.001). The mean ET-Sevo was low in group D (1.1 vs. 1.2; P < 0.001). The heart rate was significantly low across all time points in group D, without resulting in bradycardia. The median RASS and CHEOPS scores were also significantly lower in group D. No significant differences were observed in the mean arterial pressure, incidence of adverse events, or length of PACU stay. Conclusion: Low-dose dexmedetomidine was more effective than fentanyl as an opioid substitute at providing a better recovery profile in pediatric ambulatory oral rehabilitation under GA. Dexmedetomidine also significantly reduced sevoflurane consumption without causing adverse events or prolonging hospital stay.

Development of $20\;Nm^3$/hr Hydrogen Generator for Hydrogen Fueling Station (수소스테이션용 $20\;Nm^3$/hr급 수소제조장치 개발)

  • Oh, Young-Sam;Baek, Young-Soon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • In this study, $20\;Nm^3/hr$ scale compact hydrogen generator which can be apply to the hydrogen station was manufactured and tested. The design of $20\;Nm^3/hr$ scale compact hydrogen generator was upgraded on the base of $5\;Nm^3/hr$ scale plate hydrogen generator concept stacking the plate reactors. Ideas for improving system efficiency such as heat recovery from the exhaust, exhaust duct which is especially design for plate type reactor, reinforcement of insulation, enlargement of heat exchange area of reactor, introduction of desulphurizer reactor and PROX rector in a compact design etc. were applied. From the performance test, we can learn that the $20\;Nm^3/hr$ scale compact hydrogen generator can be operated steadily at 100% road condition and the methane conversion of over 94%(at S/C=3.75) was obtained. This result shows that the concept of plate type hydrogen generator can be scale-up to the $20\;Nm^3/hr$ scale and fit for hydrogen generator for on site hydrogen station application.

A Study of Motor Functional Evaluation in Stroke Patients (뇌졸중환자의 운동기능평가에 대한 연구)

  • Kang, Jeom-Deok
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.88-92
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effects of exercise on functional status in stroke patients. The understanding of the course of recovery after stroke and factors affecting outcomes are important in planning and evaluation of stroke rehabilitation. Methods: To predict the outcom of stroke patient, we measured in the beginnig of rehabilitation, on 36 patients. The variables were gender, age, duration of rehabilitation treatment, motor assessment scale(MAS). Results: The patient age in 50-59 years was 41.7%. The stroke left side motor weakness were found 55.6%. The duration of rehabilitation treatment in 2-3 months was 50.0%. In the difference 24.63 for motor assessment scale after a rehabilitation treatment had significantly higher than 10.86 for motor assessment scale at initial. Gender by motor assessment scale after a rehabilitation treatment was 25.7 in male and 23.2 in female(P<0.05). Past history by motor assessment scale after a rehabilitation treatment was 26.7 in hypertension, 24.6 in cardiac disorder and 21.8 in diabetes mellitus(P<0.05). Conclusion: The subjective symptoms of motor assessment scale after a rehabilitation treatment was significantly associated with gender.

  • PDF

Performance test of scale-up $20Nm^3/hr$ scale hydrogen generator for hydrogen station (수소스테이션용 $20Nm^3/hr$급 수소제조장치 스케일-업 및 성능시험)

  • Oh, Young-Sang;Baek, Young-Soon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.37-42
    • /
    • 2006
  • In this study, $20Nm^3/hr$ scale compact hydrogen generator which can be apply to the hydrogen station was tested for hydrogen station application. $20Nm^3/hr$ scale compact hydrogen generator was developed by upgrading concept of stacking plate reactor from former $20Nm^3/hr$ scale plate hydrogen generator. concepts for improving system efficiency and performance include such as idea of heat recovery from the exhaust, exhaust duct which is especially design for plate type reactor reinforcement of insulation, enlargement of heat exchange area of reactor, introduction of desulphurizer reactor and PROX rector in a compact design, introduction of back fire protection structure of plate burner and so on, We can learn that final prototype of scale-up $20Nm^3/hr$ scale compact hydrogen generator can be operated steadily in 100% road at which over 94% of methane conversion(S/C=3.75) was obtained. In case of making up the weak point, we expect that it is possible to apply to hydrogen station by way of showing an example.

  • PDF

Convalescence from Saturday Night Palsy (요골신경 압박마비의 회복)

  • Rhee, Seung-Yong;Han, Soo-Hong;Lee, Soon-Chul;Lee, In-Sung;Kim, Jin-Woo
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.2
    • /
    • pp.81-85
    • /
    • 2012
  • Purpose: Saturday night palsy is a transient form of nerve palsy that occurs after a prolonged period of direct pressure on the course of radial nerve by one's own or spouse's head. Although commonly encountered, there have been only few studies concerning its convalescence. The purpose of this study is to predict the prognosis of Saturday night palsy based on the causes, time to recovery and degree of recovery. Materials and Methods: Retrospective study of 20 patients who were diagnosed compression radial nerve palsy was performed. The average age was 36.7 years old and the mean follow-up period was 19.6 months. We investigated sleeping hours as an indirect measure of nerve compression time, recovery of wrist and finger extension, DASH score on the monthly based follow up. Results: The mean sleeping hours was 5.8 hours and all patients showed full recovery of wrist and fingers extension with the mean duration of symptom for 3.2 months. DASH score was an average 1.53 at the last follow up and we found no statistical significance between the time to recovery and the sleeping hours. Conclusion: Complete natural recovery can be expected in compression radial nerve palsy in this study without correlation with sleeping time. Accurate diagnosis is important in order to avoid unnecessary therapeutic intervention and further study should be accomplished for clarifying the related prognostic factors in larger scale of the cases.

  • PDF

The Optimization of Hydrometallurgical Process for Recovery of Zinc from Electric Arc Furnace Dust (Part I : leaching process) (습식산화법을 이용한 제강분진 내 아연회수를 위한 최적조건 도출에 관한 연구(Part I; 침출공정))

  • Moon, Dea-Hyun;Ahn, Sang-Woo;Kim, Han-lae;Kim, Ji-Tae;Chang, Soon-Woong
    • Resources Recycling
    • /
    • v.24 no.3
    • /
    • pp.27-33
    • /
    • 2015
  • EAFD (Electric Arc Furnace Dust) is considered as pernicious pollutant, assigned hazardous waste. Since this dust is a by-product of industry, it contains valuable metals such as Fe, Zn, Ni, Cu which can be turned into resources by recycling process. In this study, hydrometallurgical process was applied to recover Zn from Electric Arc Furnace Dusts. The result showed 95% Zn recovery at 3M $H_2SO_4$, Solids/Liquid ratio 1:2 and aeration of 1.8L/min for 2hr. However there was 80% Zn recovery at lower $H_2SO_4$ concentration apply for pilot scale plant.

Hemicellulose Recovery from Lignocellulosic Material Hydrolyzed by Water (물로 가수분해된 섬유성 기질로부터 hemicellulose 회수)

  • Kim, Sung-Bae;Kim, Chang, Joon
    • KSBB Journal
    • /
    • v.20 no.4
    • /
    • pp.317-322
    • /
    • 2005
  • Various recovery methods were investigated to maximize hemicellulose recovery from lignocellulosic material hydrolyzed by pure water. The pretreatment conditions of water hydrolysis were $170\~180^{\circ}C$ and 1 hour of reaction time. The percentage of hemicellulose solubilized increased as the temperature increased from 170 to $180^{\circ}C$. However, significant decomposition of sugar was observed at temperature of $180^{\circ}C$. From the results of water hydrolysis, the total amount of glucan in solid residue and liquid hydrolyzate was close to the total glucan in the original biomass. For hemicellulose, however, there was a significant difference between both contents. To prove this difference, various recovery methods were proposed. From the total sugar accountability (sugar in liquid + sugar in solid), it was confirmed that hemicellulose recovery in the hydrolyzate was increased if the product including both hydrolyzate and solid residue was physically stimulated by such as heating and ultrasound irradiation. This indicated that, in commercial scale processes that much bigger substrate sizes are used and a sufficient amount of leaching solvent can not be used after pretreatment, a significant amount of oligomers could be trapped in the solid matrix.

A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification (반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구)

  • Song, Won-Il;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Shin, Dae-Kun;Tae, Kyung-Eung;Kim, Yong-Sik;Park, Dug-Jun
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.