• Title/Summary/Keyword: Recording Interval

Search Result 65, Processing Time 0.027 seconds

A Mobile Flash File System - MJFFS (모바일 플래시 파일 시스템 - MJFFS)

  • 김영관;박현주
    • Journal of Information Technology Applications and Management
    • /
    • v.11 no.2
    • /
    • pp.29-43
    • /
    • 2004
  • As the development of an information technique, gradually, mobile device is going to be miniaturized and operates at high speed. By such the requirements, the devices using a flash memory as a storage media are increasing. The flash memory consumes low power, is a small size, and has a fast access time like the main memory. But the flash memory must erase for recording and the erase cycle is limited. JFFS is a representative filesystem which reflects the characteristics of the flash memory. JFFS to be consisted of LSF structure, writes new data to the flash memory in sequential, which is not related to a file size. Mounting a filesystem or an error recovery is achieved through the sequential approach. Therefore, the mounting delay time is happened according to the file system size. This paper proposes a MJFFS to use a multi-checkpoint information to manage a mass flash file system efficiently. A MJFFS, which improves JFFS, divides a flash memory into the block for suitable to the block device, and stores file information of a checkpoint structure at fixed interval. Therefore mounting and error recovery processing reduce efficiently a number of filesystem access by collecting a smaller checkpoint information than capacity of actual files. A MJFFS will be suitable to a mobile device owing to accomplish fast mounting and error recovery using advantage of log foundation filesystem and overcoming defect of JFFS.

  • PDF

EFFECT OF PARAMAGNETIC Co$_{67}$Cr$_{33}$ UNDERLAYER ON CRYSTALLOGRAPHIC AND MAGNETIC CHARACTERISTICS OF Co-Cr-Ta LAYERS IN PERPENDICULAR MAGNETIC RECORDING MEDIA

  • Kim, Kyung-Hwan;Nakagawa, Shigeki;Takayama, Seiryu;Naoe, Masahiko
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.847-850
    • /
    • 1996
  • The bi-layered films composed of Co-Cr-Ta layers and paramagnetic $Co_{67}Cr_{33}$ underlayer were deposited by suing Facing Targets Sputtering(FTS). The effects of $Co_{67}Cr_{33}$ underlayer on the crystallographic and magnetic characteristics of the Co-Cr-Ta layer deposited on the underlayer was investigated. The diffraction intensity $I_{p(002)}$ of Co-Cr-Ta layers on the $Co_{67}Cr_{33}$ layer was stronger than that of single layer and Co-Cr-Ta/Ti double layer. Therefore, the crystallinity of Co-Cr-Ta layer was imporved by the $Co_{67}Cr_{33}$ underlayer rather than Ti ones. However, te coercivity H$_{c\bot}$ of Co-Cr-Ta layers deposited on $Co_{67}Cr_{33}$ underlayer was as low as 250 Oe even at substrate temperature of $220^{\circ}C$. This H$_{c\bot}$ decrease seems to be attributed to the effect of the $Co_{67}Cr_{33}$ underlayer as well as interval time between deposition of the underlayer and the Co-Cr-Ta layer.

  • PDF

Analysis of temperature-dependent abnormal bursting patterns of neurons in Aplysia

  • Hyun, Nam Gyu;Hyun, Kwangho;Oh, Saecheol;Lee, Kyungmin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.24 no.4
    • /
    • pp.349-362
    • /
    • 2020
  • Temperature affects the firing pattern and electrical activity of neurons in animals, eliciting diverse responses depending on neuronal cell type. However, the mechanisms underlying such diverse responses are not well understood. In the present study, we performed in vitro recording of abdominal ganglia cells of Aplysia juliana, and analyzed their burst firing patterns. We identified atypical bursting patterns dependent on temperature that were totally different from classical bursting patterns observed in R15 neurons of A. juliana. We classified these abnormal bursting patterns into type 1 and type 2; type 1 abnormal single bursts are composed of two kinds of spikes with a long interspike interval (ISI) followed by short ISI regular firing, while type 2 abnormal single bursts are composed of complex multiplets. To investigate the mechanism underlying the temperature dependence of abnormal bursting, we employed simulations using a modified Plant model and determined that the temperature dependence of type 2 abnormal bursting is related to temperature-dependent scaling factors and activation or inactivation of potassium or sodium channels.

Near-infrared Laser Energy Transmission through Teeth with Crack Lines: An In-vitro Study

  • Sapra, Ashita;Darbar, Arun;George, Roy
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.214-219
    • /
    • 2021
  • Background and Objectives To evaluate the difference in near-infrared (810 nm) laser energy transmission through teeth with and without cracks. Materials and Methods Extracted teeth were sectioned and examined visually for the presence of cracks with the aid of photographs and a trans-illuminator. Fourteen sections, each with cracks (Group A) and no cracks (Group B) were identified and placed 15 mm from the tip of a 300 micron fiber, prior to activation with an 810 nm diode laser (0.1W, 50 ms interval,100 ms duration). A power meter positioned behind the tooth recorded the average energy that was transmitted through the samples. Unpaired t-test analysis was used to determine if the tooth sections with cracks allowed higher power passage compared to sound teeth. Results The mean power recording for the cracked teeth (Group A) was significantly greater (p = 0.0005) than that for the non-cracked teeth (Group B). Conclusion Within the limitations of this study, it is evident that significantly higher laser energy passes through teeth with cracks in comparison to teeth without cracks. A recent clinical study has also shown that lasers could be used to assess symptomatic cracked teeth. Hence, further research is required to determine the relative increase in energy required to identify symptomatic cracked teeth.

Extension Techniques of 8 Day Interval Recorded Stream-flow Data to Daily One (8일 간격으로 부분 계측된 유량을 연속 일유량으로 확장하는 방법)

  • Baek, Kyong-Oh;Yim, Dong-Hee
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.91-99
    • /
    • 2012
  • In this study, it was proposed that extension techniques of 8 day interval recorded stream-flow data which has been produced at the mouth of unit watersheds for TMDLs to daily one. The concept of this method was that the missing data at partial recording station was filled by using the daily data at a nearby, hydrologically similar streamgaging station. First, same day stream-flow was extracted from the daily stream-flow. Then, the extension equation was developed based on the sample data when the same day stream-flow from daily data and the partially recorded stream-flow was deeply related each other. The missing data was interpolated or extrapolated by the equation. Especially the maintenance of variance extension (MOVE) technique was used to derive the equation and was validated. Finally the 8-day interval recorded stream-flow at the mouth of unit watersheds in Han River Basin for TMDLs was extended to continuously daily data by using the method proposed in this study. And the low flow at each unit watershed was evaluated according to the flow-duration curve.

The Effects of Sensory Integration Intervention Combined With Auditory Perception Training on Sensory Processing, Visual Perception and Attention of Children With Developmental Delay: Single-Subject Design (청지각 훈련과 병행한 감각통합치료가 발달지연 아동의 감각처리, 시 지각 발달, 주의집중에 미치는 영향: 개별실험연구)

  • Park, Mi-Young;Lim, Young-Myung;Kim, Hee
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.15 no.2
    • /
    • pp.66-79
    • /
    • 2017
  • Objective : The purpose of this study is investigate the effects of sensory integration combined with auditory treatment on the sensory processing, visual perception and attention ability of children with developmental delay. Methods : A combined treatment of auditory training and sensory integration therapy was implemented to 3 children aged 4 to 7 and diagnosed with developmental delay during 9 weeks period from December 2016 to January 2017. ABA' design which is one of single subject research designs was used in this study. Baseline A had 4 sessions, intervention B had 15 sessions, and baseline A' had 4 sessions, so 23 sessions were applied in total. During the baseline A and A 'periods, visual perception ability was measured by K-DTVP-2 (Korea Developmental Test Visual Perception-2) and sensory processing ability was evaluated by sensory profile. The maintenance time of attention was measured with the absence of intervention for the baseline period, and for the intervention period, it was measured at 10 minutes break time which was provided after the intervention. The children's attention time during a fine motor task provided were measured using video recorder with the interval recording method, and the interval for the evaluation was 30 seconds. Results : No statistically significant difference were found in the visual perception function and sensory processing scores before and after treatment. Attention of participant A enhanced significantly while that of participant B and C did not improve significantly. Conclusion : It is hard to conclude that sensory integration therapy combined with auditory perception training has positive effects on visual perception function and attention of children with developmental delays. However, there were significant increase in attention and improvements in behavior related to sensory processing for some cases in this study. In further study, longer intervention periods and valid measurement need to be applied in order to get better results. And it is proposed that more studies need to be done to enhance evidence of auditory perception training as a mean to facilitate attention and to prepare learning.

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

Three-Dimensional Image Display System using Stereogram and Holographic Optical Memory Techniques (스테레오그램과 홀로그래픽 광 메모리 기술을 이용한 3차원 영상 표현 시스템)

  • 김철수;김수중
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6B
    • /
    • pp.638-644
    • /
    • 2002
  • In this paper, we implemented a three dimensional image display system using stereogram and holographic optical memory techniques which can store many images and reconstruct them automatically. In this system, to store and reconstruct stereo images, incident angle of reference beam must be controlled in real time, so we used BPH(binary phase hologram) and LCD(liquid crystal display) for controlling reference beam. The reference beams are acquired by Fourier transform of BPHs which designed with SA(simulated annealing)algorithm, and the BPHs are represented on the LCD with the 0.05 seconds time interval using application software for reconstructing the stereo images. And input images are represented on the LCD without polarizer/analyzer for maintaining uniform beam intensities regardless of the brightness of input images. The input images and BPHs are edited using application software(Photoshop) with having the same recording scheduled time interval in storing. The reconstructed stereo images are acquired by capturing the output images with CCD camera at the behind of the analyzer which transforms phase information into brightness information of images. In output plane, we used a LCD shutter that is synchronized to a monitor that display alternate left and right eye images for depth perception. We demonstrated optical experiment which store and reconstruct four stereo images in BaTiO$_3$ repeatedly using the proposed holographic optical memory techniques.

Inhibitory Modulation of 5-Hydroxytryptamine on Corticostriatal Synaptic Transmission in Rat Brain Slice

  • Choi, Se-Joon;Chung, Won-Soon;Kim, Ki-Jung;Sung, Ki-Wug
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.6
    • /
    • pp.295-301
    • /
    • 2003
  • Striatum plays a crucial role in the movement control and habitual learning. It receives an information from wide area of cerebral cortex as well as an extensive serotonergic (5-hydroxytryptamine, 5-HT) input from raphe nuclei. In the present study, the effects of 5-HT to modulate synaptic transmission were studied in the rat corticostriatal brain slice using in vitro extracellular recording technique. Synaptic responses were evoked by stimulation of cortical glutamatergic inputs on the corpus callosum and recorded in the dorsal striatum. 5-HT reversibly inhibited coticostriatal glutamatergic synaptic transmission in a dose-dependent fashion (5, 10, 50, and $10{\mu}M$), maximally reducing in the corticostriatal population spike (PS) amplitude to $40.1{\pm}5.0$% at a concentration of $50{\mu}M$ 5-HT. PSs mediated by non-NMDA glutamate receptors, which were isolated by bath application of the NMDA receptor antagonist, d,l-2-amino-5-phospohonovaleric acid (AP-V), were decreased by application of $50{\mu}M$ 5-HT. However, PSs mediated by NMDA receptors, that were activated by application of zero $Mg^{2+}$ aCSF, were not significantly affected by $50{\mu}M$ 5-HT. To test whether the corticostriatal synaptic inhibitions by 5-HT might involve a change in the probability of neurotransmitter release from presynaptic nerve terminals, we measured the paired-pulse ratio (PPR) evoked by 2 identical pulses (50 ms interpulse interval), and found that PPR was increased ($33.4{\pm}5.2$%) by 5-HT, reflecting decreased neurotransmitter releasing probability. These results suggest that 5-HT may decrease neurotransmitter release probability of glutamatergic corticostriatal synapse and may be able to selectively decrease non-NMDA glutamate receptor-mediated synaptic transmission.

CORRELATIONS BETWEEN HIPPOCAMPAL THETA RHYTHM AND INTRACELLULAR CHARACTERISTICS OF PYRAMIDAL NEURONS (해마 theta 리듬과 pyramidal neuron의 세포내 특성과의 상관관계)

  • Kwon, Oh-Heung;Kim, Young-Jin;Nam, Soon-Hyeun;Kim, Hyeun-Jung;Lee, Man-Gee;Cho, Jin-Hwa;Choi, Byung-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.671-682
    • /
    • 1998
  • Electrophysiological phenomena of pyramidal cells in the CA1 area of the dorsal hippocampus were recorded from and filled with neurobiotin in anesthetized rats. The electropharmacological properties of membrane as well as the cellular-synaptic generation of rhythmic slow activity (theta) were examined. The intracellular response characteristics of these pyramidal cells were distinctly different from responses of interneurons. Pyramidal cells had a high resting membrane potential, a low input resistance, and a large amplitude action potential. A afterhyperpolarization was followed a single action potential. Most of pyramidal cells did not display a spontaneous firing. Pyramidal cells displayed weak inward rectification and anodal break excitation. The slope of the frequency-current relation was 53.4 Hz/nA for the first interspike interval and 15.9 Hz/nA for the last intervals, suggesting the presence of spike frequency adaptation. Neurobiotin-filled neurons showed pyramidal morphology. Cells were generally bipolar dendritc processes ramifying in stratum lacunosum-moleculare, radiatum, and oriens. Commissural stimulation discharged pyramidal cells, followed by excitatory and inhibitory postsynaptic potentials (EPSPs and IPSPs). The frequency of theta-related membrane potential oscillation was voltage-independent in pyramidal neurons. At strong depolarization levels (less than 30 mV) pyramidal cells emitted sodium spike oscillation, phase-locked to theta. The observations provide direct evidence that theta-related rhythmic hyperpolarization of principal cells is brought by the rhythmically discharging interneurons. Furthermore, the findings in which interneurons were also paced by rhythmic inhibitory postsynaptic potentials during theta suggest that they were periodically hyperpolarized by their GABAergic septal afferents.

  • PDF