• Title/Summary/Keyword: Recorder

Search Result 515, Processing Time 0.03 seconds

Recorder with automatic scaling function

  • Tomita, Takehiko;Tohara, Masahiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.891-895
    • /
    • 1988
  • We discuss what kind of scale is suitable for analog signal recording paper from the viewpoint of human engineering. We show a method for automatically generating a suitable scale from the higher and lower limits of the recording range.

  • PDF

Real Time FECG Monitoring System Using Digital Signal Process (디지탈 신호처리에 의한 실시간 태아 심전도 감시 시스템에 관한 연구 I)

  • 김남현;유선국;이건기;윤대희;김원기;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.722-724
    • /
    • 1988
  • In this study, 8 ch. FECG signal storage system with general cassette recorder and amplifier is developed, and simulated LMS algorithm. In future we construct real time FECG monitor system that is used digital signal processor.

  • PDF

An extension of new laser pulse atom-probe construction and time-of-flight mass spectrum of $H_2$ and He gas (A new laser pulse atom-probe 제작 및 $H_2$ 가스와 He 가스의 time-of-flight mass spectrum)

  • 송순달;홍남관
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.3
    • /
    • pp.465-472
    • /
    • 1997
  • An extension of new test methods for surfaces with an apparatus based on photon-induced desorption and ionisation in the electric field, is constructed and tested, It also investigates how to show the efficiency of the arrangement adsorbates $H_2$ and He on W(110). The field emitter temperature was 80 K. The wavelength of light used was 193 nm with field strengths between 10 and 50 V/nm. Many ion fragments($CO^+, He^+, H_2^^+, H_2O^+, W^{3+}\; and\; W^{2+}$) were produced by an electronic stimulation of the adsorbate with the help of a photon energy of 6.4 eV at He and $H_2$/W(110). A transient recorder enables the registration of the entire mass spectrum.

  • PDF

Analyzing TMJ Sound Using a Simplified Condylar Path Recorder and a Sound Checker (과두로 단순 기록장치 및 SOUND CHECKER를 이용한 악관절음의 분석)

  • Cho, Ho-Hyun;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.113-131
    • /
    • 1988
  • Although TMJ sound is common, its relationship to subjective and objective evaluation and the magnitude and the position of the sound during the mandibular movement is not fully understood. So, the purpose of this investigation was to provide further insight into the characteristics of the TMJ sounds. Twelve subjects (9 men and 3 women) with TMJ sounds were selected from students at Chosun University, School of Dentistry. Condylar movements and TMJ sounds of each subject were recorded and analyzed using a simplified condylar path recorder and a sound checker. Although specific conclusions were difficult to make from this study, the finding suggested the followings. 1. The position of TMJ sounds were visually observed and marked on the condylar tracings during maximum opening and closing, protrusive and retrusive and right and left lateral movements. 2. Information about the size, location and number of condylar deviations and the translation freedom of the condyle was recorded and analyzed objectively. 3. The most obvious characteristic of TMJ sounds was their variability. 4. TMJ sounds were categorized into one of four groups (soft click, hard click, soft crepitus, hard crepitus) by the quality and quantity of the duration and amplitude components.

  • PDF

Research on the Method of a Composite Navigation Algorithm Using Aircraft Recorder Data (비행기록자료를 이용한 복합항법 알고리즘 구성)

  • Kim, Jae-Hyung;Lyou, Joon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.5
    • /
    • pp.462-471
    • /
    • 2008
  • Flight recoder is used to analyze the accident factors and prevent the accident. In the analysis of the flight recorder, the most important factor is how to estimate the precise location of the flight. Traditional aviation navigation is based on stable sensors such as DME and VOR. In order to enhance the precision of the location estimation, the integrated navigation algorithm is designed to incorporate DME, Air data sensors and INS(Inertial Navigation System). The results demonstrate that the proposed algorithm can achieve better accuracy, comparing with the traditional navigation schemes, in flight location estimation.

An Improvement of Expendable Bathythermograph Measurement Mechanism for Anti-Submarine Warfare (대잠용 수온측정계 측정 메커니즘 개선)

  • Shin, Sang-Sik;Cho, Hwan Hwi;Park, Seung Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.3
    • /
    • pp.301-310
    • /
    • 2014
  • Purpose: The purpose of this study is to improve a mechanism of expendable bathythermograph measurement by balancing wire resistances between plus wire part and minus wire part and by removing effects of sea water resistance between XBT(Expendable Bathythermograph) and temperature recorder. Methods: The problems are exactly found out through the analysis of XBT and temperature recorder circuit. A process of XBT manufacturing that balances wire resistances between plus wire part and minus wire part is added. Results: The results of this study are as follows; the complicated test process such as temperature accuracy test with a cistern is substituted with a simple process of XBT manufacturing such as balancing wire resistances between plus wire part and minus wire part. Then, the temperature accuracy tolerance of XBT is improved up to ${\pm}0.1^{\circ}C$. Conclusion: Consequently, balancing wire resistances and removing effects of sea water resistance improve temperature accuracy of XBT and reduce expensive and harassing process of XBT manufacturing.

Comparative Studies of Frequency Estimation Method for Fault Disturbance Recorder (고장 왜란 기록기를 위한 주파수 추정 기법의 비교 연구)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.2
    • /
    • pp.87-92
    • /
    • 2012
  • Voltage and current phasor estimation has been executed by GPS-based synchronized PMU, which has become an important way of wide-area blackout protection for the prevention of expending faults in a power system. The PMU technique can not easily get the field data and it is impossible to share information, so that there has been used a FNET(Frequency Monitoring Network) method for the wide-area intelligent protection in USA. It consists of FDR(Fault Disturbance Recorder) and IMS(Information Management System). Therefore, FDR must provide an optimal frequency estimation method that is robust to noise and failure. In this paper, we present comparative studies for the frequency estimation method using IRDWT(Improved Recursive Discrete Wavelet Transform), FRDWT(Fast Recursive Discrete Wavelet Transform), and DFT(Discrete Fourier Transform). The Republic of Korea345[kV] power system modeling data by EMTP-RV are used to evaluate the performance of the proposed two kinds of RDWT(Recursive Discrete Wavelet Transform) and DFT. The simulation results show that the proposed frequency estimation technique using FRDWT could be the optimal frequency measurement method, and thus be applied to FDR.

Studies on the gallbladder contraction induced by caerulein (Caerulein의 담낭수축작용에 관한 연구)

  • Cho, T.S.;Kim, W.J.;Hong, S.S.
    • The Korean Journal of Pharmacology
    • /
    • v.12 no.2 s.20
    • /
    • pp.1-6
    • /
    • 1976
  • The effects of phenoxybenzamine and other related drugs were studied for their interaction with caerulein on gallbladder contraction in anesthetized animals and isolated gallbladder strips. Cholecystostomy and cystic duct ligation were made on anesthetized dog, cat and pig. Pressure changes of gallbladder were measured by a physiological pressure transducer connected to polygraph recorder. Isolated rabbit gallbladder strips were placed in a muscle chamber containing Locke-Ringer solution maintained at $38^{\circ}C$. The contractile responses were measured by a force-displacement transducer connected to polygraph recorder. Caerulein ($30{\sim}200$ ng/kg i.v.) produced marked contraction of gallbladder in situ and the cholecystokinetic potencies appear in decreasing order; dog, cat and pig. The response of caerulein was abolished by the large doses of phenoxybenzamine (15 mg/kg i.v.) but not affected with dibenamine, phentolamine or tolazoline. Cholecystokinetic effect of methacholine or barium chloride was also partially inhibited by phenoxybenzamine and the effect of caerulein was weakly inhibited intravenous injection of cyclophosphamide or papaverine. In isolated rabbit gallbladder strips, the response of contraction to caerulein were progressively inhibited by pretreatment of phenoxybenzamine along with time exposed. These results lead to the conclusion that phenoxytenzamine may inherently inhibit the contractile response of gallbladder to caerulein, and this effect was not related with ${\alpha}-adrenergic$ receptor blocking action.

  • PDF