• 제목/요약/키워드: Recirculation Flow

검색결과 656건 처리시간 0.024초

복합 발전소 주급수 재순환 배관계의 고진동 현상 및 대책 (Examination on High Vibration of Recirculation System for Feed Water Piping in Combined Cycle Power Plant)

  • 김연환;김재원;박현구
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.648-654
    • /
    • 2011
  • The feed-water piping system constitutes a complex flow impedance network incorporating dynamic transfer characteristics which will amplify some pulsation frequencies. Understanding pressure pulsation waves for the feed-water recirculation piping system with cavitation problem of flow control valve is very important to prevent acoustic resonance. Feed water recirculation piping system is excited by potential sources of the shock pulse waves by cavitation of flow control valve. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the piping vibration due to the effect of shock pulsation by the cavitation of the flow control valves for the recirculation piping of feed-water pump system in combined cycle power plants.

  • PDF

스크류 데칸트 분리단 내부에서의 유동 해석 (Slurry Flow Simulation in the Separation Stage of Screw Decanter)

  • 백영수;나은수;박재덕
    • 연구논문집
    • /
    • 통권31호
    • /
    • pp.53-63
    • /
    • 2001
  • Numerical investigation based on the control-volume using finite-difference method has been made by the development of computer program in order to figure out the pattern of the flow field inside screw decanter. The typical flow pattern inside screw decanter is characterized by the two strong recirculation zones separated by the main stream from slurry discharge hole to exit. These recirculation regions and flow pattern are strongly influenced by the centrifugal force and the change of the value of slurry viscosities, that is,500, 1,000 and 3,000cp respectively. The wear of screw decanter appeared experimentally in two spots; one is near the circumferential area of the slurry discharge hole and the other is on the decanter blades at a certain height from the bottom to a different degree after the continuous long-term operation. These wears are partly explained by the flow pattern and the strong turbulence intensity near the recirculation attachment region.

  • PDF

흡수기 용액 재순환이 흡수식 냉동기 성능에 미치는 영향 (The Influences of LiBr Solution Recirculation in Absorber on the Absorption Chiller Performance)

  • 정종수;진성민;박찬우;최승학;정봉철
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.733-741
    • /
    • 2002
  • If a part of the poor solution from the absorber outlet is recirculated to the absorber inlet, the solution temperature at the solution spray pump can be reduced, and the solution flow rate in the absorber is increased. We have performed the experiments on the influences of the absorption chiller performance according to the ratio of the recirculation, defined as the ratio of the recirculation flow rate to the total solution flow rate at the absorber outlet. As increasing the ratio of the recirculation, the absorption capacity of the solution can be deteriorated. On the other hand, due to the increasing flow rate, the heat transfer rate can be enhanced. As a result, the performance of the absorber and the cooling capacity of the absorption chiller have nothing to do with the recirculation ratio, and the lifetime of the spray pump will be maintained.

MILD 연소 폐기물 소각로에서 배기가스 재순환 흡입구 위치에 따른 유동 특성 연구 (A study on the flow characteristics in a MILD combustion waste incinerator with the change of flue gas recirculation inlet location)

  • 하지수;심성훈;정응호
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.51-57
    • /
    • 2014
  • MILD 연소는 고온의 배기가스가 연소로 내에 유입되는 연료와 공기의 혼합물과 고온의 배기가스 가 만나는 위치에 따라 질소산화물 저감 특성이 많은 영향을 받는다. 본 연구에서는 폐기물소각로에 적용한 MILD 연소로에서 배기가스 재순환 여부에 따른 유동 특성과 배기가스 재순환 위치에 따른 유동 특성을 살펴보아 최적의 배기가스 재순환 위치를 선정하는 것을 목적으로 하였다. 본 연구의 전산 해석의 결과는 배기가스 재순환이 없는 경우에는 수직 격벽 상부의 단면에서 속도 분포는 수직 격벽 바로 상부에 큰 속도가 있고 더 상부는 역류가 일어나는 것을 확인할 수 있었다. 배기가스 재순환이 있는 경우는 상부 자유공간에서의 유동 균일도를 수직 격벽 상부 단면에서의 x 방향 속도의 %RMS 값으로 비교하였으며 재순환 흡입구 위치가 자유공간 우측 상단에 위치한 경우가 %RMS 값이 57.4%로 가장 작은 값을 가지며 따라서 가장 효과적임을 알 수 있었다.

Cone Type 밸브 내부유동 수치해석에 관한 연구 (A Study on the Numerical Analysis of Internal Flow in a Cone Type Valve)

  • 진도훈
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.199-207
    • /
    • 2020
  • These days, many different types of valves are developed in the industrial area according to their use purpose. Multiple kinds of valves are installed to control a flow and pressure of the pipe conveying fluid. Valves serve as critical roles in land plants such as power plants. The performance of equipment varies depending on valve characteristics. In this study, the internal flow analysis on Cone-type valve is conducted to analyze flow field and secure a value of the flow coefficient Cv. According to the internal flow analysis, when the flow distribution of the middle cross-section of valve was open 100%, flow field was relatively and smoothly taken out. If it was open 50%, flow recirculation region increased and a little complex flow field occurred. Unlike ball valve or butterfly valve, this valve had flow recirculation in its outlet depending on a valve opening amount. Therefore, it was found that there was no flow recirculation in the outlet of Cone-type valve.

회전원판형 CVD 장치의 유동 재순환을 억제하는 출구부 형상 설계를 위한 전산해석 (A COMPUTATIONAL ANALYSIS FOR OUTLET SHAPE DESIGN TO SUPPRESS FLOW RECIRCULATION IN A ROTATING-DISK CVD REACTOR)

  • 박장진;김경진;곽호상
    • 한국전산유체공학회지
    • /
    • 제18권4호
    • /
    • pp.74-81
    • /
    • 2013
  • A numerical design analysis is conducted to search for an optimal shape of outlet in a rotating-disk CVD reactor. The goal is to suppress flow recirculation that has been found in a reactor having a sudden expansion of flow passage outside of the rotating disk. In order to streamline gas flow, the sidewall at which the flow in the Ekman layer is impinged, is tilted. The axisymmetric laminar flow and heat transfer in the reactor are simulated using the incompressible ideal gas model. For the conventional vertical sidewall, the flow recirculation forming in the corner region could be expanded into the interior to distort the upstream flow. The numerical results show that this unfavorable phenomenon inducing back flow could be dramatically suppressed by tilting the sidewall at a certain range of angle. The assessment of deviation in deposition rate based on the characteristic isotherm illustrates that the sidewall tilting may expand the domain of stable plug-like flow regime toward higher pressure. A physical interpretation is attempted to explain the mechanism to suppress flow recirculation.

Flow Dynamics of Gas Turbine Swirl Nozzle

  • Moriai, Hideki;Fujimoto, Yohei;Miyake, Yoshiaki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.63-65
    • /
    • 2008
  • CFD cold-flow analysis results of the air-blast swirl nozzle for the small aircraft engine combustor are shown. Two major recirculation zones are observed near the nozzle. The centerline recirculation zone velocity profile of CFD is compared with the experimental results.

  • PDF

연료전지 수소 재순환 시스템의 유동해석 (Flow analysis of the Hydrogen Recirculation System for Fuel Cells)

  • 김재춘;이용택;정진택;김용찬;황인철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.759-764
    • /
    • 2005
  • In this paper, numerical analysis of hydrogen recycle system has been conducted in order to enhance the efficiency of automotive fuel cell. Generally, the excess hydrogen is provided in the automotive fuel cell. Since the non-reaction hydrogen reduces automotive fuel cell efficiency, reuse of the non-reaction hydrogen can be helpful to improve the fuel cell performance. In case of PEM FC, the water vapor is provided to hydrogen from the cathode so that the mixture experiences phase change depending on the changes of pressure and temperature. The internal flow of the mixture in the hydrogen recirculation system of fuel cell was investigated for real flow conditions. The variation of performance, properties and mass fractions of mixture, hydrogen and water-vapor were investigated. This study was performed based on 80KW level automotive fuel cell's recycling system.

  • PDF

연료전지 이젝터 시스템에 관한 수치해석적 연구 (A Computational Study of the Fuel-Cell Ejector System)

  • 이준희;이해동;남궁혁준;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3191-3196
    • /
    • 2007
  • The present study addresses a method to operate a fuel-cell system effectively using a recirculation ejector which recycles wasted hydrogen gas. Configuration of a recirculation ejector is changed to investigate the flow behavior through it under varying operating conditions, and how such conditions affect the fuel-cell hydrogen cycle. The numerical simulations are based on a fully implicit finite volume scheme of the axisymmetric, compressible, Reynolds-Averaged, Navier-Stokes equations for hydrogen gas, and are compared with available experimental data for validation. The results show that a hydrogen recirculation ratio is effectively controlled by a configurational alteration within the operational region in which the recirculation passage doesn't plugged by a sonic line.

  • PDF

수소 연료전지차의 재순환시스템 모델링 연구 (Modeling of Hydrogen Recirculation System for Fuel Cell Vehicle)

  • 김재훈;노용규;전의식;이종현
    • 한국수소및신에너지학회논문집
    • /
    • 제22권4호
    • /
    • pp.481-487
    • /
    • 2011
  • A fuel cell vehicle using a polymer electrolyte membrane fuel cell (PEM FC) as power source produces electric power by consuming the fuel, hydrogen. The unconsumed hydrogen is recirculated and reused to gain higer stack efficiency and to maintain the humidity in the anode side of the stack. So it is needed considering fuel efficiency to recirculated hydrogen. In this study, the indirect hydrogen recirculation flow rate measurement method for fuel cell vehicle is presented. By modeling of a convergent nozzle ejector and a hydrogen recirculation blower for the hydrogen recirculation of a PEM FC, the hydrogen recirculation flow rate was calculated by means of the mass balance and heat balance at Anode In/Outlet.