• Title/Summary/Keyword: Recirculating

Search Result 402, Processing Time 0.025 seconds

Separation Performance of a Low-pressure Hydrocyclone for Suspended Solids in a Recirculating Aquaculture System

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.150-156
    • /
    • 2010
  • The separation performance of a low-pressure hydrocyclone (LPH) was evaluated for suspended-solids removal in a recirculating aquaculture system (RAS). The dimensions of the LPH were 335 mm cylinder diameter, 575 mm cylinder height, 60 mm overflow diameter, 50 mm underflow diameter, and $68^{\circ}$ cone angle. The inflow rate varied (400, 600, 800, and 1,000 mL $s^{-1}$) with 25%, 25%, 20%, and 10% of bypass ($R_f$), respectively. The maximum total separation efficiency (Et) and reduced separation efficiency (E't) for suspended solids from the effluent of the second settlement tank (before biofiltration) were 58.9% and 45.2%, respectively, at an inflow rate of 600 mL $s^{-1}$ and 25% of $R_f$. The maximum Et and E't for suspended solids from the water supply channel (after biofiltration) were 24.4% and 16%, respectively, at an inflow rate of 1,000 mL $s^{-1}$ and 10% of $R_f$. The maximum grade efficiency (Ei) was 51.6% for a 300 ${\mu}m$ particle size at an inflow rate of 600 mL $s^{-1}$ with 23% of $R_f$. The maximum reduced grade efficiency (E'i) was 37.6% for a 300 ${\mu}m$ particle size at an inflow rate of 1,000 mL $s^{-1}$ with 11% of $R_f$. The results indicate that the separation performance of the LPH for suspended solids removal was size selective and that maximum removal occurred at particle sizes ranging from 300 to 500 ${\mu}m$.

Performance of Three Different Biofilter Media in Laboratory-Scale Recirculating Systems for Red Seabream Pagrus major Culture

  • Harwanto, Dicky;Oh, Sung-Yong;Park, Heung-Sik;Jo, Jae-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.371-378
    • /
    • 2011
  • Juvenile red seabream (mean body weight 29.0 g) were reared in recirculating culture systems with three different biofilter media, sand (SF), polystyrene microbeads (PF), and Kaldnes beads (KF). The efficiencies of the three different biofilter media were also tested. The SF was fluidized, and the PF and KF were trickled. All treatments were duplicated. The volumetric removal rates of total ammonia nitrogen by SF, PF, and KF were 193.8, 183.9, and 142.6 g $m^{-3}day^{-1}$, respectively, and those of nitrite nitrogen ($NO_2$-N) were 113.4, 105.9, and 85.8 g $m^{-3}day^{-1}$, respectively. The TAN and $NO_2$-N removal rates of KF were lower than those of SF and PF (P < 0.05), but there was no significant difference in these rates between SF and PF (P > 0.05). Among the biofilters used, only KF showed total suspended solid (TSS) removal capacity. The TSS removal efficiencies of SF and PF were negative. The growth rates of fish in SF were significantly higher than those in KF but not higher than those in PF. There was no difference in growth rate between fish in PF and KF. The specific growth rate and feed conversion efficiency of red seabreams in KF were lower than those in SF and PF, but there were no significant differences between SF and PF. These results indicate that sand and polystyrene microbeads are recommended for red seabream culture in a recirculating system.

Efficiency of a hybrid solid digestion-denitrification column in suspended solid and nitrate removal from recirculating aquaculture system

  • Pungrasmi, Wiboonluk;Chaisri, Ratchadaporn;Malaphol, Ekachai;Powtongsook, Sorawit
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.175-180
    • /
    • 2015
  • This research focused on the solid and nitrate removal efficiency in a solid digestion-denitrification column. The 20 L up-flow column consisted of 18 L acrylic column with 2 L down-comer inlet tube located in the middle. In the first part, the wastewater with high suspended solids from the Tilapia fish tank was applied into the sedimentation unit at 5 variable flow rates i.e., 11.25, 25.71, 60, 105.88 and 360 L/h. The results indicated that the flow rate of 11.25 L/h (0.57 m/h) gave the highest solid removal efficiency of $72.72%{\pm}8.24%$. However, the total suspended solids removal was highest at 360 L/h (18.13 m/h). In the second part, methanol was added as an external organic carbon source for denitrification process in a hybrid column containing settled solids. The COD:N ratios of 0.5:1, 1:1, 2:1, 3:1, 4:1, 5:1 and 6:1 were investigated and compared with control without methanol addition. This experiment was operated at the HRT of 1 h with 450 L wastewater from recirculating aquaculture pond containing 100 mg-N/L sodium nitrate. The results indicated that the COD:N ratio of 3:1 gave the highest nitrate removal efficiency of $33.32%{\pm}21.18%$ with the denitrification rate of 5,102.88 mg-N/day.

Analysis for the Flow and Wall Shear Stress with the Diameter Ratios of an Abdominal Aortic Aneurysm in a Pulsatile Flow (맥동 유동에서 복부 대동맥류의 직경비에 따른 유동 및 벽면전단응력 해석)

  • 모정하
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.181-187
    • /
    • 2002
  • The objective of the present study was to two-dimensionally investigate the characteristics of flow and wall shear stress under pulsatile flow in the aneurysm which is a local dilatation of the blood vessel for pulsatile flow. The numerical simulation using the commercial software were carried out for the diameter ratios(ratio of maximum diameter of aneurysm to the diameter of blood vessel) ranging from 1.5 to 2.5 and Womersley number, 15.47. It was shown that a recirculating flow at the bulge was developed and disappeared for one Period and the strength of vortex increased with the diameter ratio Especially. at time of 3.19s. the very weak recirculating flow was developed at the left upper sites of the aneurysm. The maximum values of the wall shear stress increased in Proportion to the diameter ratio. However. the Position of a maximum wall shear stress was the distal end of the aneurysm(z = 35mm) regardless of the diameter ratios.

Evaluation of Pollutant Load Unit Factor for Calculating Pollutants Emission in Aquacultural Farms (양식계 오염원 배출량 산정을 위한 원단위 설정)

  • Park, Jae Hong;Park, Bae Kyoung;Rhew, Doug Hee;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.656-665
    • /
    • 2013
  • This research was conducted to investigate pollutant load unit factor from aquacultural farms. Pollutant load unit factors were investigated on the 13 kinds of fish type, i.e., Trout, Leather Carp, Eel, Carp, Cartfish, Freshwater Eel, Crucian Carp, Colored Carp, Sturgeon, Marsh Snail, Sweetfish, Pond Snail, Eriocheir Sinensis. Water qualities in aquacultural farms were investigated wide range of values by fish type and pollutant items. High BOD and COD values were observed at the Leather Carp (Ponded water system), Cartfish (Ponded water system) and Freshwater Eel (Recirculating System). TOC and DOC values were relatively high at the Freshwater Eel (Recirculating System) and Eriocheir Sinensis (Extensive). Eel (Ponded water system) and Freshwater Eel (Recirculating System) produced high concentrated nutrient pollutants, i.e., T-N, T-P. Pollutant load unit factors are dependent on fish type, aquacultural type, water quality items, etc. If some fishes have similar basic unit values, those could be applied for TMDLs as a group of fish having same pollutant load unit. The water quality concentrations of post treatment facilities' (mainly reservoir tank) effluent were higher than those of fish raising bath because of extracting pollutant from sediment in the reservoir tank. Therefore, it needs to the management and regulations about post treatment facilities.

Treatment of Aquacultural Recirculating Water by Foam Separation - II. Characteristics of Solid Removal - (포말 분리법을 이용한 양어장 순환수 처리 - II. 고형물 제거특징 -)

  • SUH Kuen-Hack;LEE Min-Gyu;LEE Min-Soo;KIM Byong-Jin;KIM Eun-Jung;CHO Moon-Chul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.3
    • /
    • pp.334-339
    • /
    • 1997
  • The feasibility of foam separation to remove solid produced from fish culture water was investigated. Performance characteristics of foam separator were highly dependent upon the operating parameters which were superficial air velocity, Hydraulic retention time (HRT), and foam height. About $50\%$ of the total protein contained in a sample of fish culture water could be removed by foam separator. The removal efficiencies of protein, T-N, TA, and solid components were increased with increasing superficial air velocity and HRT. The combined effects of these operational variables show that removal rates of TVS increase with increasing superficial air velocity and HRT, and decrease as foam height goes up. It could be confirmed that foam separator might offer good perspective for removal of harmful components such as TA and TVS in aquacultural recirculating water.

  • PDF

Effects of Stocking Density and Dissolved Oxygen Concentration on the Growth and Hematology of the Parrotfish Oplegnathus fasciatus in a Recirculating Aquaculture System (RAS) (순환여과시스템에서 사육밀도와 용존산소 농도가 돌돔(Oplegnathus fasciatus)의 성장과 혈액성상에 미치는 영향)

  • Kim, Pyong-Kih
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.6
    • /
    • pp.747-752
    • /
    • 2011
  • The parrotfish Oplegnathus fasciatus is a sub-tropical species that is difficult to culture during the winter in South Korea. As a result, a recirculating aquaculture system (RAS) was developed to rear parrotfish. This study investigated the effects of stocking density and dissolved oxygen (DO) concentration on the growth and hematology of the parrotfish in the RAS. The experimental stocking densities were 5 (SD05), 10 (SD10), 15 (SD15), and 20 kg/m3 (SD20) total body weight to tank water volume. As the stocking density increased, the mean weight gain, feed efficiency, and specific growth rate tended to decrease. However, SD10 and SD15 did not differ statistically from SD05 in feed efficiency (P>0.05). Although better growth was achieved in SD05, SD10 and SD15 appeared to be acceptable, practically and economically, in terms of feed efficiency. The experimental DO concentration ranges were 3-4 (DO3), 5-6 (DO5), and 7-8 mg/L (DO7). The mean weight gain and survival tended to increase with the DO concentration, but there were no differences among treatments (P>0.05). Although the feed efficiency did not differ among the treatments, the specific growth rates and daily feed intake increased with the DO concentration and were the highest in DO7 (P<0.05). The cortisol concentration was the highest in DO3 (P<0.05), while there was no difference between DO5 and DO7 (P>0.05).

Water Treatment of Seawater Recirculating Aquaculture System by Using Three Phase Fluidized Bed Reactor (삼상 유동층 반응조를 이용한 해수 순환 여과 시설의 수처리)

  • Lee, Byung-Hun;Choi, Hyeok;Ryu, Jong-Soo
    • Journal of Aquaculture
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2000
  • Capacity of water treatment of the three phase fluidized bed reactor as a biofilter in the seawater recirculating system was evaluated. The water treatment system consists of fluidized bed reactor for ammonia removal, cartridge filter for solid removal and ozone contactor for disinfection. Mean concentration of water quality parameters: COD, TAN, $NO_2$-N, $NO_3$-N, SS and alkalinity were 9.0, 0.22, 0.05, 20.0, 9.5 and 70.0 mg/l, respectively; the relevant values were 7.6 for pH and 3.64 NTU for turbidity. These indicate the maintenance of good water quality by the treatment system. The influent TAN loading rate in to the fluidized bed reactor ranged from 4.3 to 32.9 g/$m^3$/day, and averaged to 20 g/$m^3$/day. TAN removal efficiency of each phase of the fluidized bed reactor was 47-60%, indicating the effective ammonia removal. During operation the effluent of fluidized bed reactors also maintained the unionized ammonia nitrogen level below 0.002 mg/l.

  • PDF

Measurement and Analysis of Coal Conversion Efficiency for a Coal Recirculating Fuel Cell Simulator (석탄순환형 연료전지 모사시스템용 석탄전환율 측정 및 분석법개발에 관한 연구)

  • Lee, Sangcho;Kim, Chihwan;Hwang, Munkyeong;kim, Minseong;Kim, Kyubo;Jeon, Chunghwan;Song, Juhun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.5
    • /
    • pp.503-512
    • /
    • 2012
  • There is a new power generation system such as direct coal fuel cell (DCFC) with a solid oxide electrolyte operated at relatively high temperature. In the system, it is of great importance to feed coal continuously into anodic electrode surface for its better contact, otherwise it would reduce electrochemical conversion of coal. For that purpose, it is required to improve the electrochemical conversion efficiency by using either rigorous mixing condition such as fluidized bed condition or just by recirculating coal particle itself successively into the reaction zone of the system. In this preliminary study, we followed the second approach to investigate how significantly particle recycle would affect the coal conversion efficiency. As a first phase, coal conversion was analyzed and evaluated from the thermochemical reaction of carbon with air under particle recirculating condition. The coal conversion efficiency was obtained from raw data measured by two different techniques. Effects of temperature and fuel properties on the coal conversion are specifically examined from the thermochemical reaction.

Ozone-produced Oxidants Improve Water Quality Parameters and Microbial Colony Counts in the Semi-Recirculating Aquaculture System for Olive Flounder Paralichthys olivaceus (반순환여과양식시스템에서 오존 유래 잔류산화물이 넙치(Paralichthys olivaceus) 사육수의 수질과 미생물에 미치는 영향)

  • Jung, Sangmyung;Park, Woogeun;Park, Seongdeok;Park, Jeonghwan;Kim, Jae-Won;Kim, Pyong-kih
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.751-760
    • /
    • 2021
  • This study investigated the changes in water quality parameters and microbial colonies when ozone was applied to a semi-recirculating aquaculture system (semi-RAS) for the olive flounder Paralichthys olivaceus (500 g in average weight). Concentrations of ozone-produced oxidants (OPO) in rearing tanks were maintained at 0, 0.014, 0.025 mg/L as Cl2 for 26 days. Except total ammonia nitrogen, nitrite nitrogen, nitrate nitrogen, phosphate phosphorus, chemical oxygen demand, and total suspended solids decreased significantly with increasing OPO concentration in daily and weekly monitoring (P<0.05). Colony forming unit (CFU) counts of heterotrophic marine bacteria decreased in an OPO concentration-dependent manner. Overall reduction rates of microbial colonies in the treatments were 80% higher than those of the control (P<0.05). During the experiment, the OPO concentration-driven ozonation was reliably practiced without any adverse effects on the animals cultured in semi-RAS. Considering the biohazard, operating cost, and stability of ozonation, an OPO concentration of 0.014 mg/L would be sufficient to control water quality parameters and microbial colonies in a semi-RAS.