• 제목/요약/키워드: Recirculating

검색결과 404건 처리시간 0.027초

전기저항법에 의한 공업용수 부식억제제의 성능시험 (Evaluation of Cooling Water Corrosion Inhibitors by the Electrical Resistance Method)

  • 민원규
    • 대한화학회지
    • /
    • 제7권4호
    • /
    • pp.251-253
    • /
    • 1963
  • Six corrosion inhibitors for cooling water use were evaluated by means of a corrosometer in a laboratory bench scale test. A steel probe (Alloy 1020) was exposed and checked for the extent of corrosion in a recirculating water system, changing inhibitors and their concentrations at $40^{\circ}C$. A 95% inhibition was provided at the following concentrations of inhibitors. 50 ppm sodium hexametaphosphate 50 ppm commercial inhibitor A 50 ppm commercial inhibitor B 100 ppm disodium phosphate 200 ppm sodium chromate Sodium silicate was found to be use-less in this test. It was also observed that some inhibitors worked less effectively on the acid-cleaned steel probe.

  • PDF

전기 변압기 형상 내부의 밀폐공간 내에서 층류 자연대류 열전달 현상의 수치해석 (Numerical Analysis on Natural Convection Heat Transfer in an Enclosure of the Transformer Model)

  • 오건제
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.106-115
    • /
    • 1992
  • Numerical analysis of the laminar natural convection in an enclosure of the 20KVA oil-immeresed transformer is presented. The core in the transformer is modelled as a rectangular cylinder and calculation is carried out for $Ra=10^3-10^6$. The correlating equation between the inner cylinder mean Nusselt numbers and Rayleigh numbers can be obtained. The conduction and convection regimes for the variation of Rayleigh numbers are well represented in the temperature distributions along the side wall of the inner cylinder. For high Rayleigh numbers, it is found that the recirculating flow in the enclosure above the inner cylinder is divided into two recirculation regions.

  • PDF

밀집형 열교환기 내 공기 측 대류열전달특성 (Analysis for Air-Side Convective Heat Transfer Characteristics in Compact Heat Exchangers)

  • 모정하;이상호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1443-1448
    • /
    • 2009
  • Numerical analysis has been carried out to investigate air-side convective heat transfer characteristics in compact heat exchangers with continuous plate fins. Simulation results such as air flow and temperature distributions are presented, and heat transfer characteristics are compared for various inlet conditions. Results from various turbulence models are also compared for applicability. There is large difference between the local heat transfer coefficient distributions along the cylinder wall for circular tubes. Colburn j factors from the calculated results of circular and flat tubes in the heat exchangers are compared for various Reynolds number. The predicted results in this study can be applied to the optimal design of air conditioning system. with compact heat exchanger.

  • PDF

로켓 배기플룸에 관한 3차원 수치해석 (Three-Dimensional Computations of Rocket Exhaust Plume)

  • 김영목
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1999년도 추계 학술대회논문집
    • /
    • pp.71-76
    • /
    • 1999
  • The base flow regions of a three-body sounding rocket containing multiple exhaust plumes were numerically investigated in three dimensions for a free stream Mach number of 2.7 at flight altitude 18.5 km. The flowfields were calculated using the full compressible Navier-Stokes equations with an one-equation turbulence model of Baldwin-Earth. The present calculations were executed based upon a chemically frozen, single perfect gas model assumption. Due to the symmetry of the three-body rocket of each single nozzle, only one fourth of the computational domain was considered for the analysis. The results indicate that a babe heating effect is not considerable due to the small expansion of the plumes. In the base, however, a low speed recirculating flow dominates the region.

  • PDF

유량분배 매니폴드의 유출유동에 대한 출구형상 영향 해석 (EFFECT OF EXIT SHAPE ON TURBULENT OUTFLOWS IN A DISTRIBUTION MANIFOLD)

  • 이준우;박태선
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.73-79
    • /
    • 2014
  • Three-dimensional turbulent flows of a distribution manifold are studied by a turbulence model. To investigate the geometrical effects of the manifold, the length and area of exit port are changed. From the results, flow structures related to the outflow uniformity are examined and the deparure angles are obtained. The exit configuration depending on the departure angle has advantages to the outflow uniformity. That is, the decreased exit area in the streamwise direction improves the uniformity of exit flow. For the uniform effusion, the change of exit port by departure angle is more effective them the change of exit area.

화염편 및 조건평균법 모델을 이용한 재순환 비예혼합 난류 화염장의 해석 (Flamelet and Conditional Moment Closure Modeling for the Turbulent Recirculating Nonpremixed Flames)

  • 김군홍;강성모;김용모
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1616-1624
    • /
    • 2004
  • The conditional moment closure(CMC) model has been implemented in context with the unstructured-grid finite-volume method which efficiently handle the physically and geometrically complex turbulent reacting flows. The validation cases include a turbulent nonpremixed CO/$H_2$/$N_2$ Jet flame and a turbulent nonpremixed $H_2$/CO flame stabilized on an axisymmetric bluff-body burner. In terms of mean flame field, minor species and NO formation, numerical results has the overall agreement with expermental data. The detailed discussion has been made for the turbulence-chemistry interaction and NOx formation characteristics as well as the comparative performance for CMC and flamelet model.

소형 모세관식 알카리 금속 열전변환소자의 사이클해석 (Cycle Analysis of an Alkali Metal Thermo-Electric Converter for Small Capillary Type)

  • 윤석구;구재현;이재근;전중 경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.956-961
    • /
    • 2000
  • This paper describes the design of a small size Alkali Metal Thermal to Electric Converter (AMTEC) which employs a capillary structure for recirculating sodium working fluid. The cycle is based on the simple and small capillary type ${\beta}"$ -alumina and wick tube element. The proposed cell consists of the 37 conversion elements with capillary tube of $50{\mu}m$ in diameter and the sealed cylindrical vessel of 22mm in outer diameter. Results on the cycle analysis of sodium flow and heat transfer in the cell showed that the expected power output was 4.65W and the conversion efficiency was 19% for the source temperature of 900K.

  • PDF

중앙분공형 보염기 후류에 안정된 난류확산화염의 구조에 관한 연구(II) (A Study on the Structure of Turbulent Diffusion Flame Behind the Hollowed Flame Holder(II))

  • 강인구;이우섭;문중권;이도형
    • 동력기계공학회지
    • /
    • 제3권3호
    • /
    • pp.29-35
    • /
    • 1999
  • The purpose of study is to investigate the flame stability and structure of turbulent diffusion flame behind the hollowed flame holder, which is located on the waste gas coming out from the test furnace. PDFs and Power Spectra technique of fluctuating temperature and ion current measurement were needed for this purpose. We discussed that the three types of stabilized flames were found as the result of post study. In this paper, we established the stability mechanism near the flame holder.

  • PDF

Fan Filter Unit 소음ㆍ진동 특성과 청정실에 미치는 영향성 평가에 관한 연구 (A Study on the noise & vibration properities of Fan Filter Unit and evaluation of effect to Clean Room)

  • 백재호;손성완
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.778-784
    • /
    • 2002
  • FFU are used increasingly by the microeleceronics industry to provide clean recirculating air for the fabrication of integrated circuits and laminar flow air. There may be several hundred ffu in a large cleanroom, covering 100% of the ceiling area. Hence, there is of often knowledge in the inside and outside of the country the flu give rise to noise & vibration trouble to microelectronics industry. Noise & Vibration control for satisfication about noise & vibration criteria in TFT-LCD factory cleanroom be in need of exact noise & vibration data of accurence from utility & equipment that can be exert a bad influence upon cleanroom. In this pater, hence we found out noise and vibration properities of ffu by using experimental method. And, we performed noise & vibration analysis about noise it vibration level in cleanroom using semiempirical method for quantative approach about noise & vibration level in cleanroom.

  • PDF

Effects of probiotics on growth and immune responses in olive flounder, Paralichthys olivaceus and on water quality parameters of recirculating rearing system

  • Yousuke Taoka;Jo, Jae-Yoon;Hiroto Maeda;Sungchul C. Bai;Lee, Won-Jae
    • 한국어업기술학회:학술대회논문집
    • /
    • 한국어업기술학회 2003년도 춘계 수산관련학회 공동학술대회발표요지집
    • /
    • pp.201-202
    • /
    • 2003
  • Recently, probiotics is applied for aquaculture management as an alternative method of antibiotics. Probiotics is defined as a live microbial feed supplement which a good effect to the host animal by improving its microbial condition of gastrointestinal tract (Fuller, 1989). Generally, probiotics affect growth and survival of cultured fish, water quality, immune system and so on (Rengpipat et al, 2000, Robertson et al, 2000). (omitted)

  • PDF