• Title/Summary/Keyword: Recirculated $CO_2$

Search Result 17, Processing Time 0.026 seconds

Numerical Investigation of Low-pollution Combustion with applying Flue Gas Recirculation in Counterflow Flames: Part I. Combustion Characteristics of Low NOx (대향류 화염에서 FGR이 적용된 저공해 연소의 수치적 해석: Part I. 저 NOx 연소특성)

  • Cho, Seo-Hee;Lee, Kee-Man
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.8-16
    • /
    • 2019
  • One of the methods for low-pollution combustion, flue gas recirculation(FGR) is effective to reduce nitrogen oxides and it was applied in CH4/air premixed counterflow flames to identify the change of flame characteristics and NOx mechanisms. Considering that the mole fraction of the products varied depending on the strain rates, the major products: CO2, H2O, O2 and N2 were recirculated as a diluent to reflect the actual combustion system. With the application of the FGR technique, a turning point of maximum flame temperature under certain strain rate condition was found. Furthermore as the recirculation ratio increased, the tendency of NO was changed before and after the turning point and the analysis on thermal NO and Fenimore NO production was conducted.

A Study on Exhaust Gas Emissions Characteristics of EGR with Scrubber for Marine Diesel Engine (선박용 디젤기관에 있어서 스크러버형 배기재순환 시스템의 배기배출물 특성에 관한 연구)

  • 임재근;조상곤
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.57-62
    • /
    • 2000
  • The effect of exhaust gas recirculation(EGR) on the characteristics of exhaust gas emissions, and SFC are experimentally investigated by four-cylinder, four-cycle and direct injection marine diesel engine. In order to reduce the soot contents in the recirculated exhaust gas to intake system of the engines, a soot removal system of a cylinderical-type scrubber is specially designed and manufactured for the experimental system. (1) SFC is increased in downward convex curve style with increasing excess air ratio, it is increased with increasing EGR rate at the same excess air ratio. (2) NOx emission is reduced in downward convex curve style with increasing excess air ratio, it is reduced with increasing EGR rate at the same excess air ratio. (3) Soot emission is decreased in downward convex curve style with increasing excess air ratio, it is reduced with increasing EGR rate at the same excess air ratio. (4) CO emission is increased in nearly straight line style with increasing excess air ratio, it is increased with increasing EGR rate at the same excess air ratio. (5) HC emission is not constant tendency with increasing excess air ratio, it is increased with increasing EGR rate at the same excess air ratio.

  • PDF

A Study on the Effect of Automotive Engine Performance by Using Carbon Nano Colloid Cooling Water (탄소나노콜로이드 냉각수를 사용하여 자동차 엔진성능의 향상에 관한 연구)

  • Yi, Chung-Seob;Lee, Byung-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.134-142
    • /
    • 2011
  • Although combustion is essential in most energy generation processes, it is one of the major causes of air pollution. Exhaust pipes with circular fin were designed to study the effect of cooling the recirculated exhaust gases (EGR) of Diesel engines on the chemical composition of the exhaust gases and the reduction in the percentages of pollutant emissions. The gases examined in this study were oxides of nitrogen (NOx), carbon dioxide ($CO_2$) and carbon monoxide (CO). In addition, $O_2$ concentration in the exhaust was measured. The designs adopted in this study were about exhaust pipes with solid and hollow fins around them direct surface force measurement in water using a nano size colloidal probe technique. The direct force measurement between colloidal surfaces has been an essential topic in both theories and applications of surface chemistry. As particle size is decreased from micron size down to true Carbon nano Colloid size (<10 nm), surface forces are increasingly important. Nano particles at close proximity or high solids loading are expected to show a different behavior than what can be estimated from continuum and mean field theories. The current tools for directly measuring interaction forces such as a surface force apparatus or atomic force microscopy (AFM) are limited to particles much larger than nano size. This paper use Water and CNC fluid at normal cooling system of EGR. Experimental result showed all good agreement at Re=$2.54{\times}10^4$ by free convection and Re=$3.36{\times}10^4$ by forced air furnace.

Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part II: Multi-dimensional Fire Dynamics) (구획화재에서 환기조건의 변화가 화재특성에 미치는 영향 (Part II: 다차원 화재거동))

  • Kim, Jong-Hyun;Ko, Gwon-Hyun;Park, Chung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.32-38
    • /
    • 2010
  • Multi-dimensional fire dynamics were studied numerically with the change in ventilation conditions in a full-scale ISO 9705 room. Fire Dynamic Simulator (FDS) was used for the identical conditions conducted in previous experiments. Flow rate and doorway width were changed to create over-ventilated fire (OVF) and under-ventilated fire (UVF). From the numerical simulation, it was found that the internal flow pattern rotated in the opposite direction for the UVF relative to the OVF so that a portion of products recirculated to the inside of compartment. Significant change in flow pattern with ventilation conditions may affect changes in the complex process of CO and soot formation inside the compartment due to increase in the residence time of high-temperature products. The fire behavior in the UVF created complex 3D characteristics of species distribution as well as thermal and flow structures. In particular, additional burning near the side wall inside the compartment significantly affected the flow pattern and CO production. The distribution of CO inside the compartment was explained with 3D $O_2$ distribution and flow patterns. It was observed that gas sampling at local positions in the upper layer were insufficient to completely characterize the internal structure of the compartment fire.

Seasonal atmospheric characteristics in a swine finishing barn equipped with a continuous pit recirculation system using aerobically treated manure

  • Choi, Yongjun;Ha, Duck-Min;Lee, Sangrak;Kim, Doo-Hwan
    • Animal Bioscience
    • /
    • v.35 no.12
    • /
    • pp.1977-1985
    • /
    • 2022
  • Objective: This study was conducted to determine the seasonal characteristics of odorous material emissions from a swine finishing barn equipped with a continuous pit recirculation system (CPRS) using aerobically treated manure. Methods: The CPRS consists of an aerobic manure treatment process and a pit recirculation system, where the solid fraction is separated and composted. The aerated liquid fraction (290.0%±21.0% per day of total stored pig slurry) is continuously recirculated to the top of the slurry in the pit. Four confinement pig barns in three piggery farms were used: two were equipped with CPRS, and the other two operated a slurry pit under the slatted floor across all seasons. Results: The indoor, exhaust, and outside odor intensities were significantly lower in the CPRS group than in the control group (p<0.001). In the CPRS group, the odor intensity outside was significantly lower in the fall than in the other seasons (p = 0.015). In the indoor atmosphere, the temperature and CO2, NH3, and H2S contents of the CPRS group were significantly lower than those of the control group (p<0.05). In the CPRS group, indoor temperature did not significantly change in the spring, summer, and fall seasons and was significantly lower in the winter (p = 0.002). NH3, H2S, methyl mercaptan, dimethyl disulfide, trimethylamine, phenol, indole, and skatole levels were significantly lower in the CPRS group than in the control group (p<0.05). There were significant seasonal differences on the odorous material in both the control and CPRS groups (p<0.05), but the pattern was not clear across seasons. Conclusion: The CPRS can reduce the indoor temperature in the summer to a level similar to that in the spring and fall seasons. The CPRS with aerated liquid manure is expected to reduce and maintain malodorous emissions within acceptable limits in swine facilities.

Conditions Affecting Vegetable Waste Composting (야채쓰레기의 효율적 퇴비화를 위한 운영조건)

  • Choi, Jung-Young;Namkoong, Wan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.1
    • /
    • pp.19-29
    • /
    • 1994
  • The purpose of this study was to investigate the feasibility of composting of vegetable wastes containing high moisture. The parameters investigated were the effect of energy source addition, difference in bulking agent and recirculation of leachate produced during composting. Laboratory scale composting reactors were used in this study. Chinese cabbages were used as a vegetable waste. Dog food was added to the vegetable waste as a energy source. Wood chips and leaves of platan were used as bulking agents. There may be an appropriate amount of energy source to be added for composting high moisture content vegetable waste. In this study, the appropriate amount of energy source was 20% of the vegetable waste by weight basis. Recirculation of total amount of leachate produced each day on the same day may not be an appropriate approach due to the significant heat-quenching effect. When the total amount of leachate produced was equally devided and recirculated everyday through the whole composting period, the heat-quenching effect was comparatively less significant. There were no notable differences in the temperature profile and the $CO_2$ evoluation rate when leaves were used instead of wood chips as bulking agents. Considering waste recycling, it is desirable to use leaf waste as bulking agents if available, because the leaves are also wastes to be disposed of.

  • PDF

A Study on the Quantitative Recovery of Dissolved Inorganic Carbonates in Ground Water for Radiocarbon Measurement (방사성탄소 측정을 위한 지하수 중에 용존된 무기탄소 화합물의 정량적 회수 연구)

  • Chun, Sang-Ki;Woo, Hyung-Joo;Cho, Soo-Young;Kim, Nak-Bae;Lee, Jong-Dae
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.284-289
    • /
    • 1999
  • Dissolved inorganic carbonates in ground water were quantitatively recovered by using gas evolution method. Gas evolution method was found to be less time-consuming, less susceptible to the contamination fromatmospheric $CO_2$ and little affected by the sulfate ions in comparison to the direct precipitation method. Extraction efficiency of nearly 99% could be achieved by gas evolution method in two hours using recirculated gas at a sweeping rate of 4 liter per minute. Samples for carbon isotope fractionation study were collected in three fractions with collection times. The evolution time for the first fraction was one hours, and then second and third fractions were collected at intervals of 30 minutes, respectively. A small portion of each fraction was analyzed to evaluate ${\delta}^{13}C$ values, which were measured to be -7.9‰, -3.0‰ and +0,4‰ for the each fraction. The result clearly indicated that gas evolution method generates isotopically lighter carbon at the beginning of the purging process and heavier isotopes at the end. However, this isotope fractionation effect could be neglected by the almost complete recovery of carbonates.

  • PDF