• Title/Summary/Keyword: Recharge Rate

Search Result 126, Processing Time 0.025 seconds

Estimation Methods of Groundwater Recharge Rate in Small Basin (소유역의 지하수함양율 추정기법)

  • 박재성;김경호;전민우;김지수
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.76-86
    • /
    • 1999
  • It is necessary to estimate the groundwater recharge rate properly to predict the demand of groundwater and to establish the plan for the development of groundwater in the future. In this paper, A small basin in Chojung area is selected to calculate the groundwater recharge rate. In the calculation, water balance analysis, SCS-CN (Soil Conservation Service-Curve Number) method. groundwater-level analysis and hydrograph of outflow analysis are applied to this area. Data of precipitation measured by Chungju climatological station for about 10 years are used for water balance analysis and SCS-CN method. For the groundwater-level analysis. variations of groundwater-level measured from the 3 test wells in 1997's are used and stage-discharge rating curves in this area for 3 years are used for the hydrograph of outflow. The recharge rate calculated by water balance is 19%, 12.95% by SCS-CN method. 16.51% by groundwater-level analysis and 10.9% by hydrograph of outflow analysis and the overall average recharge rate is about 14.84%.

  • PDF

A Study on Delineation of Groundwater Recharge Rate Using Water-Table Fluctuation and Unsaturate Zone Soil Water Content Model (지하수위 변동 예측 및 비포화대 함수모델을 이용한 지하수 함양율 산정 연구)

  • Cho, Jin-Wook;Park, Eun-Gyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.1
    • /
    • pp.67-76
    • /
    • 2008
  • In this study, a combined model of a water-table fluctuation and a soil moisture content model is proposed for the estimation of groundwater recharge rate at a given location. To evaluate the model, groundwater level data from 4 monitoring wells (Pohang Yeonil, Pohang Kibuk, Suncheon Oeseo, Hongcheon Hongcheon) of National Groundwater Monitoring Network from 1996 to 2005 and precipitation data of corresponding years are used. From the proposed methodology, the groundwater recharge rates are estimated to be from 0.5 to 61.4% for Hongcheon Hongcheon, from 1.1 to 27.4% for Pohang Yeonil, from 5.1 to 41.4% for Pohang Kibuk, and from 1.1 to 8.3% for Suncheon Oeseo. The magnitude of variation of the estimated recharge rate depends on the soil type observed near the stations. The groundwater fluctuation model used in this study includes precipitation as a unique source of water-table perturbation and there may exist corollary limitations. To improve the applicability of the proposed method, a capillary-water content constitutive model for unsaturated fractured rock media may be considered. The proposed recharge rate delineation method is physically based and uses minimum numbers of assumptions. The method may be used as a better substitute for the previous tools for delineating recharge rate of a location using water-table fluctuation method and contribute to national groundwater management plan. Further research on the spatial interpolation of the method is under progress.

Recharge Potential Assessment of Artificial Recharge System for Agricultural Drought Adaptation (농업가뭄대응을 위한 인공함양 시스템의 함양능력 평가)

  • Lee, Jae Young;Kim, Gyoo Bum
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.1
    • /
    • pp.61-72
    • /
    • 2021
  • There is an increasing need for water supply plan using sustainable groundwater to resolve water shortage problem caused by drought due to climate change and artificial aquifer recharge has recently emerged as an alternative. This study deals with recharge potential assessment for artificial recharge system and quantitative assessment for securing stable water and efficient agricultural water supply adapt to drought finding optimal operating condition by numerical modeling to reflect recharge scenarios considering climate condition, target water intake, injection rate, and injection duration. In order to assess recharge potential of injection well, numerical simulation was performed to predict groundwater level changes in injection and observation well respect to injection scenarios (Case 1~4) for a given total injection rate (10,000 m3). The results indicate that groundwater levels for each case are maintained for 25~42 days and optimal injection rate is 50 m3/day for Case 3 resulted in groundwater level rise less than 1 m below surface. The results also show that influential area of groundwater level rise due to injection was estimated at 113.5 m and groundwater storage and elapsed time were respectively increased by 6 times and 4 times after installation of low permeable barrier. The proposed assessment method can be contributed to sustainable agricultural water supply and stable water security for drought adaptation.

Estimation of Distributed Groundwater Recharge in Jangseong District by using Integrated Hydrologic Model (통합수문모형을 이용한 장성지역의 분포형 지하수 함양량 추정)

  • Chung, Il-Moon;Park, Seunghyuk;Lee, Jeong Eun;Kim, Min Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.517-526
    • /
    • 2018
  • As groundwater recharge shows the heterogeneity in space and time due to land use and soil types, estimating daily recharge by integrated hydrologic analysis is needed. In this work, the SWAT-MODFLOW model was applied to compute daily based groundwater recharge in Jangseong region. The accuracy of the model was evaluated by comparing the observed and calculated values of the unsteady groundwater flow levels after calibrating the observed and calculated flow rates of the stream for a hydrological analysis. The estimated hydrologic components showed a strong correlation with each other and significant spatial variations regarding the groundwater recharge rate in accordance with the heterogeneous watershed characteristics such as subbasin slope, land use, and soil type. Overall, it was concluded that the coupled hydrologic models were capable of simulating the spatial variation with respect to the hydrologic component process in surface water and groundwater. The average recharge rate was estimated at approximately 20.8%.

Analysis of Groundwater Recharge in Anseong River Basin under Urbanization and Future Climate Change (도시화 및 기후변화에 의한 안성천 유역의 지하수 함양량 변화 분석)

  • Woo, Soyoung;Kim, Wonjin;Chang, Sunwoo;Choi, Sijung;Kim, Chul-Gyum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.483-493
    • /
    • 2024
  • This study analyzed changes in groundwater recharge due to urbanization and future climate change using the SWAT hydrological model in the Anseong river basin (1,647 km2) adjacent to the west sea of Korea. The urbanization scenario was constructed based on increasing urban density and expansion, resulting in a decrease in groundwater recharge and recharge rate by 19.9 mm and 1.77 %, respectively. Future climate change scenarios were simulated using two models representing extreme rainfall and drought, with the drought model indicating that maintaining an average recharge rate of 21.6 % would be challenging. Results from the combined scenario of urbanization and extreme drought suggest that groundwater recharge during the spring season in urban areas would be most significantly affected.

Preliminary Evaluation of the Optimal Injection Rate and Injection Efficiency of Groundwater Artificial Recharge Site Using Numerical Model (수치모델을 활용한 지하수 인공함양 대상지의 적정 주입량 및 주입효율 예비 평가)

  • Cha, Jang-Hwan;Kim, Gyoo-Bum;Lee, Jae Young
    • The Journal of Engineering Geology
    • /
    • v.31 no.1
    • /
    • pp.19-30
    • /
    • 2021
  • This study evaluated the injection rate and the injection efficiency of the artificial recharge in the upper drought-prone watershed region, where the remaining water was used for injection, by using a numerical model to secure water during a drought. As a result of a numerical model under the condition of diverse injection rates per a well and hydraulic characteristics of the aquifer, the optimal injection rate per a well was estimated as 50.0 ㎥/day, and the injection efficiency was simulated as 33.2% to 81.2% of the total injection volume. As the injection time was shorter, the injection efficiency tented to increase non-linearly. As the injection rate increased, the residual storage in aquifer increased and available groundwater amount also increased, which could be advantageous for drought relief. For a more accurate assessment of injection efficiency, the model will be validated using the field injection data and optimum scenarios will enable the efficient operation of the artificial recharge system in the study area.

도시화에 따른 갑천유역의 지하 수문 특성 변화 분석

  • Kim Jeong-Gon;Son Gyeong-Ho;Go Ik-Hwan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.64-67
    • /
    • 2006
  • The main purpose of this research was to investigate the effects of urbanization on the groundwater system in the Gap river basin, a sub-basin of the Geum river basin. In this analysis, we constructed a water cycle analysis system using SWAT. Then, changes in soil moisture and recharge rate due to land-use changes were investigated using different land-use data estimated in 1975 and 2000. Simulation results were analyzed for both draught (2001) and flood (2003) years to take into account different hydrologic conditions. It was shown that recharge rate in the most urbanized area (31% change) was reduced by 17% for both periods due to urbanization. The results also indicated that soil moisture decrease due to urbanization was more sensitive in the drought year (2001) than in the flood year (2003), We expect that the results of this research can contribute to providing useful information for managing urban rivers considering river restoration and flood control.

  • PDF

Estimation of the Groundwater Recharge Rate during a Rainy Season at a Headwater Catchment in Gwangneung, Korea (광릉 원두부 소유역에서의 우기 중 지하수 함양률 평가)

  • Choi, In-Hyuk;Woo, Nam-Chil;Kim, Su-Jin;Moon, Sang-Ki;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.2
    • /
    • pp.75-87
    • /
    • 2007
  • Groundwater recharge rates were estimated and compared in a headwater catchment at the Gwangneung Supersite using three different methods: water-table fluctuation (WTF), mass balance, and hydrograph separation techniques. Data were obtained during the rainy season from June to September 2005. Two different WTF methods estimated the groundwater recharge rate as 25.9% and 23.6%. The mass balance calculation of chloride ions indicated recharge rates of 13.4% on average. Baseflow separation using chloride ion as a tracer from six storm hydrographs produced a 14.0% net baseflow rate on average. Because of the implicit assumption of a long-term steady state without storage change, recharge rates calculated by mass balance and hydrograph separation were smaller than those done with WTF methods, which include the amount of increased storage due to the water-level rise. Subsequently, the WTF method is superior to others in the estimation of groundwater recharge rate to comprehend the dynamic characteristics of the hydrologic cycle.

Estimating Exploitable Groundwater as a Function of Precipitation Using a Distributed Hydrologic Model and Frequency Analysis (분포형 수문모형과 빈도해석을 이용한 강수량별 지하수 개발가능량 산정)

  • Kim, Minsoo;Jeong, Gyocheol;Lee, Jeong Eun;Kim, Min-Gyu
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.253-268
    • /
    • 2020
  • In this study, recharge rates are estimated using SWAT-K (a distributed hydrological model). The validity of the estimated recharge rates were evaluated by employing the baseflow separation method based on observed hydrological data. The exploitable groundwater is typically determined as the 10-year drought frequency recharge rate that is calculated by average recharge ratio multiplied by 10-year drought frequency precipitation. In practice, however, recharge rates typically decrease in line with precipitation; therefore, exploitable groundwater could be overestimated when average recharge rates are used without considering precipitation. To resolve this overestimation, exploitable groundwater was calculated by re-estimating recharge rates that consider precipitation intensity. By applying this method to the Uiwang, Gwacheon, and Seongnam sub-basins, the exploitable groundwater decreased by 55.5~77.6%, compared with recharge rates obtained using the existing method.

A Study on the Estimation of Regional Groundwater Recharge Ratio (지역단위 지하수 자연함양율 산정방법 연구)

  • 최병수;안중기
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.2
    • /
    • pp.57-65
    • /
    • 1998
  • Recently, many researchers have studied on the estimation of groundwater storage and its usable amount in Korea. Those studies were, however, mostly on the groundwater recharge amount over the nation or for the large extent of areas. On the other hand, it has been also needed to study on the regional recharge rate for the planning of groundwater management or for the assessment of groundwater development impacts. In this paper, two practical methods for the estimation of regional groundwater recharge have been studied and proposed, which are $\circled1$ the estimation of the groundwater recharge due to the SCS-CN infiltration method, and $\circled2$ the estimation of groundwater recharge ratio by analyzing groundwater level hydrographs.

  • PDF