• Title/Summary/Keyword: Receiver sensitivity

Search Result 584, Processing Time 0.034 seconds

Diagnostic Accuracy of 18F-FDG-PET in Patients with Testicular Cancer: a Meta-analysis

  • Zhao, Jing-Yi;Ma, Xue-Lei;Li, Yan-Yan;Zhang, Bing-Lan;Li, Min-Min;Ma, Xue-Lei;Liu, Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3525-3531
    • /
    • 2014
  • Objective: Fluorine-18-fluorodeoxyglucose positron emission tomography (18F-FDG-PET) is a new technique for identifying different malignant tumors using different uptake values between tumor cells and normal tissues. Here we assessed the diagnostic accuracy of 18F-FDG-PET in patients with testicular cancer by pooling data of existing trials in a meta-analysis. Methods: PubMed/MEDLINE, Embase and Cochrane Central Trials databases were searched and studies published in English relating to the diagnostic value of FDG-PET for testicular cancer were collected. The summary receiver operating characteristic (SROC) curve was used to examine the FDG-PET accuracy. Results: A total of 16 studies which included 957 examinations in 807 patients (median age, 31.1 years) were analyzed. A meta-analysis was performed to combine the sensitivity and specificity and their 95% confidence intervals (CIs), from diagnostic odds ratio (DOR), positive likelihood ratios (PLR), negative likelihood ratio (NLR). SROC were derived to demonstrate the diagnostic accuracy of FDG-PET for testicular cancer. The pooled sensitivity and specificity were 0.75 (95% confidence interval (CI), 0.70-0.80) and 0.87 (95% CI, 0.84-0.89), respectively. The pooled DOR was 35.6 (95% CI, 12.9-98.3). The area under the curve (AUC) was 0.88. The pooled PLR and pooled NLR were 7.80 (95% CI, 3.73-16.3) and 0.31 (95% CI, 0.23-0.43), respectively. Conclusion: In patients with testicular cancer, 18F-FDG-PET demonstrated a high SROC area, and could be a potentially useful tool if combined with other imaging methods such as MRI and CT. Nevertheless, the literature focusing on the use of 18F-FDG-PET in this setting still remains limited.

Diagnostic Significance of Combined Detection of Epstein-Barr Virus Antibodies, VCA/IgA, EA/IgA, Rta/IgG and EBNA1/IgA for Nasopharyngeal Carcinoma

  • Cai, Yong-Lin;Li, Jun;Lu, Ai-Ying;Zheng, Yu-Ming;Zhong, Wei-Ming;Wang, Wei;Gao, Jian-Quan;Zeng, Hong;Cheng, Ji-Ru;Tang, Min-Zhong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2001-2006
    • /
    • 2014
  • The objective of this study was to investigate the diagnostic significance of EBV antibody combined detection for nasopharyngeal carcinoma (NPC) in a high incidence region of southern China. Two hundred and eleven untreated NPC patients, 203 non-NPC ENT patients, and 210 healthy controls were recruited for the study. The titers of VCA/IgA and EA/IgA were assessed by immunoenzyme assay, and the levels of Rta/IgG and EBNA1/IgA were determined by enzyme-linked immunosorbent assay. The levels of VCA/IgA, EA/IgA, Rta/IgG and EBNA1/IgA demonstrated no association with gender or age (p>0.05). The receiver operating characteristic curve and the area under the curve were used to evaluate the diagnostic value. The sensitivity of VCA/IgA (98.1%) and the specificity of EA/IgA (98.5%) were the highest. When a logistic regression model was used to combine the results from multiple antibodies to increase the accuracy, the combination of VCA/IgA+Rta/IgG, whose area under the curve was 0.99, had the highest diagnostic efficiency, and its sensitivity, specificity and Youden index were 94.8%, 98.0% and 0.93 respectively. The data suggest that the combination of VCA/IgA+Rta/IgG may be most suitable for NPC serodiagnosis.

Diagnostic Value of Endorectal Ultrasound in Preoperative Assessment of Lymph Node Involvement in Colorectal Cancer: a Meta-analysis

  • Li, Li;Chen, Shi;Wang, Ke;Huang, Jiao;Liu, Li;Wei, Sheng;Gao, Hong-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3485-3491
    • /
    • 2015
  • Background: Nodal invasion by colorectal cancer is a critical determinant in estimating patient survival and in choosing appropriate preoperative treatment. The present meta-analysis was designed to evaluate the diagnostic value of endorectal ultrasound (EUS) in preoperative assessment of lymph node involvement in colorectal cancer. Materials and Methods: We systematically searched PubMed, Web of Science, Embase, and China National Knowledge Infrastructure (CNKI) databases for relevant studies published on or before December 10th, 2014. The sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR) and area under the summary receiver operating characteristics curve (AUC) were assessed to estimate the diagnostic value of EUS. Subgroup analysis and meta-regression were performed to explore heterogeneity across studies. Results: Thirty-three studies covering 3,016 subjects were included. The pooled sensitivity and specificity were 0.69 (95%CI: 0.63-0.75) and 0.77 (95%CI: 0.73-0.82), respectively. The positive and negative likelihood ratios were 3.09 (95%CI: 2.52-3.78) and 0.39 (95%CI: 0.32-0.48), respectively. The DOR was 7.84 (95%CI: 5.56-11.08), and AUC was 0.80 (95%CI: 0.77-0.84). Conclusions: This meta-analysis indicated that EUS has moderate diagnostic value in preoperative assessment of lymph node involvement in colorectal cancer. Further refinements in technology and diagnostic criteria are necessary to improve the diagnostic accuracy of EUS.

Fibulin-3 as a Diagnostic Biomarker in Patients with Malignant Mesothelioma

  • Kaya, Halide;Demir, Melike;Taylan, Mahsuk;Sezgi, Cengizhan;Tanrikulu, Abdullah Cetin;Yilmaz, Sureyya;Bayram, Mehmet;Kaplan, Ibrahim;Senyigit, Abdurrahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1403-1407
    • /
    • 2015
  • Background: New tumour biomarkers are being intensely investigated for malignant mesothelioma (MM). Fibulin-3 is produced in MM but its role remains uncertain. The aim of this study was to evaluate the validity of measuring serum fibulin-3 in the diagnosis and prognosis of MM. Materials and Methods: This prospective study was performed on 43 patients and 40 healthy controls who were admitted to our hospital between January 2012 and January 2014. Data from MM patients, including demographic and clinical features, routine laboratory data, levels of serum fibulin-3, and treatment outcomes were defined as potential prognostic factors. The receiver operating characteristic (ROC) curve for fibulin-3 was used to detect the cut-off value with highest sensitivity and specificity. Univariate survival analysis was performed using the Kaplan-Meier method in patients with MM. Afterwards, the possible factors identified with univariate analyses were entered into the cox regression analysis. Results: Our results revealed that patients with MM had significantly higher serum levels of fibulin-3 than controls. The results showed that the best cut-off point was 36.6 ng/ml with an AUC (area under the curve)=0.976, sensitivity=93.0% and specificity=90.0. In our study, the initial significant poor prognostic factors were advanced stage, high white blood cell count, high platelet count, high C-reactive protein (p<0.05 for each variable). Later, according to multivariate analysis the results showed only advanced stage as significant parameter (p=0.040). Conclusions: We determined that real use for serum fibulin-3 was not for prognosis but for diagnosis in MM. Also advanced stage was associated with poor MM prognosis.

Selection and optimization of nutritional risk screening tools for esophageal cancer patients in China

  • Dong, Wen;Liu, Xiguang;Zhu, Shunfang;Lu, Di;Cai, Kaican;Cai, Ruijun;Li, Qing;Zeng, Jingjing;Li, Mei
    • Nutrition Research and Practice
    • /
    • v.14 no.1
    • /
    • pp.20-24
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: Malnutrition has multiple impacts on surgical success, postoperative complications, duration of hospital stay, and costs, particularly for cancer patients. There are various nutrition risk screening tools available for clinical use. Herein, we aim to determine the most appropriate nutritional risk screening system for esophageal cancer (EC) patients in China. SUBJECTS/METHODS: In total, 138 EC patients were enrolled in this study and evaluated by experienced nurses using three different nutritional screening tools, the Nutrition Risk Screening 2002 tool (NRS2002), the Patient-generated Subjective Globe Assessment (PG-SGA), and the Nutrition Risk Index (NRI).We compared sensitivity, specificity, positive and negative likelihood ratios, and Youden index generated by each of the three screening tools. Finally, cut-off points for all three tools were re-defined to optimize and validate the best nutritional risk screening tool for assessing EC patients. RESULTS: Our data suggested that all three screening tools were 100% sensitive for EC patients, while the specificities were 44.4%, 2.96%, and 59.26% for NRS 2002, PG-SGA, and NRI, respectively. NRI had a higher positive likelihood ratio as well as a higher area under the receiver operating characteristic curve compared to those of NRS 2002 and PG-SGA; although, all three tools had null negative likelihood ratios. After adjusting the cut-off points, the specificity and accuracy for all tools were significantly improved, however, the NRI remained the most appropriate nutritional risk screening system for EC patients. CONCLUSIONS: The NRI is the most suitable (highest sensitivity and accuracy) nutritional risk screening tool for EC patients. The performance of the NRI can be significantly improved if the cut-off point is modified according to the results obtained using MedCalc software.

Meaning of the DR-$70^{TM}$ Immunoassay for Patients with the Malignant Tumor (악성 종양 환자에 대한 DR-$70^{TM}$ 면역 분석법의 의의: Validation Study)

  • Lee, Ki-Ho;Cho, Dong-Hee;Kim, Sang-Man;Lee, Duck-Joo;Kim, Kwang-Min
    • IMMUNE NETWORK
    • /
    • v.6 no.1
    • /
    • pp.43-51
    • /
    • 2006
  • Background: The DR-$70^{TM}$ immunoassay is a newly developed cancer diagnostic test which quantifies the serum fibrin degradation products (FDP), produced during fibrinolysis, by antibody reaction. The purpose of this study was to evaluate the potential of DR-$70^{TM}$ Immunoassay in screening malignant tumor. Methods: Sample subjects were 4,169 adults, both male and female, who visited the health promotion center of a general hospital from March 2004 to April 2005 and underwent the DR-$70^{TM}$ immunoassay test and other tests for cancer diagnosis. The patient group was defined as 42 adults out of the sample subjects who were newly diagnosed with cancer during the same time period when the DR-$70^{TM}$ immunoassay test was performed. Final confirmation of a malignant tumor was made by pathological analysis. Results: The mean DR-$70^{TM}$ level was $0.83{\pm}0.65{\mu}g/ml$ (range: 0.00 (0.0001)${\sim}7.42{\mu}g/ml)$ in the control group (n=4,127) as opposed to $2.70{\pm}2.33{\mu}g/ml$ (range: $0.12{\sim}9.30{\mu}g/ml)$ in the cancer group (n=42), and statistical significance was established (p<0.0001, Student t-test). When categorized by the type of malignant tumor, all cancer patients with the exception of the subgroups of colon and rectal cancer showed significantly higher mean DR-$70^{TM}$ levels compared with the control group (p<0.0001, Kruscal-Wallis test). The receiver operating characteristic (ROC) curve analysis revealed ${\geq}1.091{\mu}g/ml$ as the best cut-off value. Using this cut-off value, the DR-$70^{TM}$ immunoassay produced a sensitivity of 71.4%, a specificity of 70.1%, a positive predictability of 69.4%, and a negative predictability of 69.2% (1). Conclusion: A significant increase in the mean DR-$70^{TM}$ value was observed in the cancer group (thyroidal, gastric, breast, hepatic and ovarian) com pared with the control group. In particular, the specificity and sensitivity of the DR-$70^{TM}$ immunoassay was relatively high in the subgroups of breast, gastric, and thyroidal cancer patients. There is need for further studies on a large number of malignant tumor patients to see how the DR-$70^{TM}$ level might be changed according to the differentiation grade and postoperative prognosis of the malignant tumor.

Study on the Development of Optical Sensor Linear Fire Detection System Using Raman Scattering (라만산란을 이용한 광센서 선형 화재감지시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Lim, Woo-Sub;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.27-38
    • /
    • 2016
  • The paper reports the development of a distributed temperature sensing (DTS) system, which is a fire detection system using optical sensor linear detectors that depends on foreign and domestic technologies. This study accordingly analyzed the electrical signal patterns of Raman scattering light mainly used for temperature sensing among back-scattered light generated in optical fiber by using an oscilloscope. Through the measurement results, it could be verified that the Stokes signal patterns had little change by the temperature increase, but the temperature-sensitive anti-Stokes patterns had relative increase of the changes. This study developed a K-DTS system, which is an optical sensor linear fire detection system composed of an optical repeater and a receiver that can detect fires using Raman scattering light. It could be verified that the developed K-DTS system satisfied the type approval standards through the sensitivity tests using the rate of rise type and fixed temperature type sensitivity testers. In addition, performance experiments have been performed for performance evaluation of the K-DTS system developed in comparison with S-DTS system which has been imported from abroad and widely used in Korea. It can be confirmed from the results of the performance experiments using model tunnels that comparable performances can be obtained in fire detection locations and the measurements of fire temperatures.

Serum anti-M$\ddot{u}$llerian hormone levels as a predictor of the ovarian response and IVF outcomes

  • Choi, Min-Hye;Yoo, Ji-Hee;Kim, Hye-Ok;Cha, Sun-Hwa;Park, Chan-Woo;Yang, Kwang-Moon;Song, In-Ok;Koong, Mi-Kyoung;Kang, Inn-Soo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.38 no.3
    • /
    • pp.153-158
    • /
    • 2011
  • Objective: The aim of this study was to investigate whether anti-M$\ddot{u}$llerian hormone (AMH) levels could be predict ovarian poor/hyper response and IVF cycle outcome. Methods: Between May 2010 and January 2011, serum AMH levels were evaluated with retrospective analysis. Three hundred seventy infertile women undergoing 461 IVF cycles between the ages of 20 and 42 were studied. We defined the poor response as the number of oocytes retrieved was equal or less than 3, and the hyper response as more than 25 oocytes retrieved. Serum AMH was measured by commercial enzymelinked immunoassay. Results: The number of oocytes retrieved was more correlated with the serum AMH level (r=0.781, $p$ <0.01) than serum FSH (r=-0.412, $p$ <0.01). The cut-off value of serum AMH levels for poor response was 1.05 ng/mL (receiver operating characteristic [ROC] curves/area under the curve [AUC], $ROC_{AUC}$=0.85, sensitivity 74%, specificity 87%). Hyper response cut-off value was 3.55 ng/mL $ROC_{AUC}$=0.91, sensitivity 94%, specificity 81%). When the study group was divided according to the serum AMH levels (low: <1.05 ng/mL, middle: 1.05 ng/mL - 3.55 ng/mL, high: >3.55 ng/mL), the groups showed no statistical differences in mature oocyte rates (71.6% vs. 76.5% vs. 74.8%) or fertilization rates (76.9% vs. 76.6% vs. 73.8%), but showed significant differences in clinical pregnancy rates (21.7% vs. 24.1% vs. 40.8%, $p$=0.017). Conclusion: The serum AMH level can be used to predict the number of oocytes retrieved in patients, distinguishing poor and high responders.

Development of the Korean Developmental Screening Test for Infants and Children (K-DST)

  • Chung, Hee Jung;Yang, Donghwa;Kim, Gun-Ha;Kim, Sung Koo;Kim, Seoung Woo;Kim, Young Key;Kim, Young Ah;Kim, Joon Sik;Kim, Jin Kyung;Kim, Cheongtag;Sung, In-Kyung;Shin, Son Moon;Oh, Kyung Ja;Yoo, Hee-Jeong;Yu, Hee Joon;Lim, Seoung-Joon;Lee, Jeehun;Jeong, Hae-Ik;Choi, Jieun;Kwon, Jeong-Yi;Eun, Baik-Lin
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.11
    • /
    • pp.438-446
    • /
    • 2020
  • Background: Most developmental screening tools in Korea are adopted from foreign tests. To ensure efficient screening of infants and children in Korea, a nationwide screening tool with high reliability and validity is needed. Purpose: This study aimed to independently develop, standardize, and validate the Korean Developmental Screening Test for Infants and Children (K-DST) for screening infants and children for neurodevelopmental disorders in Korea. Methods: The standardization and validation conducted in 2012-2014 of 3,284 subjects (4-71 months of age) resulted in the first edition of the K-DST. The restandardization and revalidation performed in 2015-2016 of 3.06 million attendees of the National Health Screening Program for Infants and Children resulted in the revised K-DST. We analyzed inter-item consistency and test-retest reliability for the reliability analysis. Regarding the validation of K-DST, we examined the construct validity, sensitivity and specificity, receiver operating characteristic curve analysis, and a criterion-related validity analysis. Results: We ultimately selected 8 questions in 6 developmental domains. For most age groups and each domain, internal consistency was 0.73-0.93 and test-retest reliability was 0.77-0.88. The revised K-DST had high discriminatory ability with a sensitivity of 0.833 and specificity of 0.979. The test supported construct validity by distinguishing between normal and neurodevelopmentally delayed groups. The language and cognition domain of the revised K-DST was highly correlated with the K-Bayley Scales of Infant Development-II's Mental Age Quotient (r=0.766, 0.739), while the gross and fine motor domains were highly correlated with Motor Age Quotient (r=0.695, 0.668), respectively. The Verbal Intelligence Quotient of Korean Wechsler Preschool and Primary Scales of Intelligence was highly correlated with the K-DST cognition and language domains (r=0.701, 0.770), as was the performance intelligence quotient with the fine motor domain (r=0.700). Conclusion: The K-DST is reliable and valid, suggesting its good potential as an effective screening tool for infants and children with neurodevelopmental disorders in Korea.

Value of Image Subtraction for the Identification of Hepatocellular Carcinoma Capsule on Gadoxetic Acid-Enhanced MRI (가도세틱산-조영증강 MRI에서 간세포암 피막 발견에 대한 영상차감기법의 진단적 가치)

  • Kim, Hyunjung;Ahn, Jhii-Hyun;Moon, Jin Sil;Cha, Seung-Whan
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.340-347
    • /
    • 2018
  • Purpose: To evaluate value of image subtraction for identifying hepatocellular carcinoma (HCC) capsule on gadoxetic acid-enhanced MR images. Materials and Methods: This study involved 108 patients at risk of HCC preoperatively examined using gadoxetic acid-enhanced MRI with hepatic resection between May 2015 and February 2017. We evaluated qualities of subtraction images and presence of capsular appearance on portal venous or transitional phases conventional and subtraction images. We assessed effect of capsular appearance on subtraction images on HCC. Results: After excluding 1 patient who had treated by transarterial chemoembolization prior to surgery and 33 patients with unsatisfactory subtraction image qualities, 82 focal hepatic lesions (73 HCC, 5 non-HCC malignancies, and 4 benign) from 74 patients were analyzed. Regarding detection of capsules, sensitivity, accuracy, and area under the receiver operating characteristic curve (AUC) on subtraction images were significantly higher than those on conventional images (95.4%, 89.0%, and 0.80, respectively; p < 0.001), though specificities were same (64.7%). For diagnosis of HCC, sensitivity, accuracy, and AUC on subtraction images were significantly higher than on conventional images (82.2%, 79.3%, and 0.69, respectively; p = 0.011), though specificities were identical (55.6%). Conclusion: Portal venous or transitional phase gadoxetic acid-enhanced MRI subtraction images could improve detection of HCC capsule.